Delta Electronics DNL SIP Series manuale d’uso
- Visualizza on-line o scarica il manuale
- 20 pagine
- 0.53 mb
Vai alla pagina of
Manuali d’uso simili
-
Power Supply
Delta Electronics LFZ24H
1 pagine 0.12 mb -
Power Supply
Delta Electronics DVPPS01
2 pagine 0.21 mb -
Power Supply
Delta Electronics SMT Power Inductor MPO13X
1 pagine 0.39 mb -
Power Supply
Delta Electronics SMT Power Inductor SIWCM73L
1 pagine 0.1 mb -
Power Supply
Delta Electronics S 523
1 pagine 0.15 mb -
Power Supply
Delta Electronics SIQ73
1 pagine 0.21 mb -
Power Supply
Delta Electronics HMS1365MH
1 pagine 0.15 mb -
Power Supply
Delta Electronics H48SN
13 pagine 0.46 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Delta Electronics DNL SIP Series. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Delta Electronics DNL SIP Series o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Delta Electronics DNL SIP Series descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Delta Electronics DNL SIP Series dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Delta Electronics DNL SIP Series
- nome del fabbricante e anno di fabbricazione Delta Electronics DNL SIP Series
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Delta Electronics DNL SIP Series
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Delta Electronics DNL SIP Series non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Delta Electronics DNL SIP Series e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Delta Electronics in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Delta Electronics DNL SIP Series, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Delta Electronics DNL SIP Series, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Delta Electronics DNL SIP Series. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Evaluation Procedure (DEP-001 A) The Delphi DNM and DNL Series of SIP type POL converters The DNM and DNL, 2.4~5.5V or 10~14V input, programmable output, non-isolated point of load DC/DC converters, are the latest of fering from one of the world’s largest power supply manufacturers ― Delta Electronics, Inc. The DNM and DNL product family also h[...]
-
Pagina 2
2 3.0 Equipment Required 3.1 A DC Power Supply 0 - 20 V @ 0 - 20A (Agilent 6574A 0 -60V/0 - 35A or equivalent). 3.2 An oscilloscope (T ektronix TDS 3034 or equivalent) 4 Channel 300 MHz, equipped with a x1 scope probe, a x10 scope probe, and two BNC cables (length less than 20 inches/500mm) 3.3 Digital m ulti-meters, one with 20A range and ideally [...]
-
Pagina 3
3 4.1 Connect one lead from the “+” lead of the DC source (S ee Item 3.1) to the “20A” terminal of the first multi-meter DVM1 (See Item 3.3). Then connect one lead from the “Common” of the DVM1 to the “Vin” pin of the Evaluation Board. DVM1 is used to measure the input current. 4.2 Connect one wire from the “-” lead of the DC so[...]
-
Pagina 4
4 6.0 T est s Performed The following tests are p erformed at room temperature (+25 ℃ ). 6.1 Input Characteristics Input V oltage Range. Under-V oltage Lockout. No Load Input Current. 6.2 Output Characteristics Line Regulation. Load Regulation. Output Regulation. Output V oltage Set-point Programming Output V oltag[...]
-
Pagina 5
5 5) SW2 is used to enable or disable the converter . For positive logic module, When SW2 is pose for the ON position, the converter is ON, and SW2 is pose for the OFF position, the converter is OFF . For negative logic module, When SW2 is pose for the ON position, the converter is OFF , and SW2 is pose for the OFF position, the converter is ON. 6)[...]
-
Pagina 6
6 8.0 T est s and Evaluation 8.1 Input Characteristics 8.1.1 Input V oltage Range and Under-V olt age Lockout The DNM04xx and DNL04xx Series of DC/DC converters will operate at full load from 2.4Vin to 5.5Vin for 5Vin (nominal) types. The DNM12xx and DNL12xx Series DC/DC converters will operate at full load from 10V in to 14Vin for 12V in (nominal)[...]
-
Pagina 7
7 8.2 Output Characteristics 8.2.1 Line Regulation Line Regulation Deviation is defined as the change in output volt age caused by varying the input voltage over a specified range while the ou tput load and temperature remain const ant. T est 1) T urn on the fan. 2) Set the output power to the desired operating point. 3) Set the switch SW2 to the c[...]
-
Pagina 8
8 8.2.4 Output V olt age Set-point Programming (1) Output V olt age Set-Point Ad justment by external resistor Output V oltage Set-point Programming can be carried out by using the external program resistor connect between TRIM pin to ground to set output volt age set-point from 0.75Vdc to 5Vdc, the location can refer to the Evaluation Board Schema[...]
-
Pagina 9
T able 2. Vo , s e t Rset (k Ω ) R33 Recommend Value, R//R 0.7525 Open Open 1.2 22.464 23.7k//432k 1.5 13.047 14.0k//191k 1.8 9.024 9.53k//169k 2.5 5.009 5.23k//118k 3.3 3.122 3.16k//261k 5.0 1.472 1.5k//78.7k T est 1. Put the resistor to program the desired output voltage set point by follow T able 1 and T able 2 for the standard output. 2. Set [...]
-
Pagina 10
For DNM12xx and DNL12xx series () 7525 . 0 0667 . 0 7 . 0 − × − = Vout Vtrim V For example, to program the output voltage of a DNL12 module to 3.3 Vdc, Vtrim is calculated as follows: () 53 . 0 7525 . 0 3 . 3 0667 . 0 7 . 0 = − × − = Vtrim V T able 4. : V o,set adjustment range using external voltage source. Product Part Normal Output Set[...]
-
Pagina 11
11 8.2.6 Voltage Tracking The DNM/DNL family was designed for applications that have output voltage tracking requirements during power-up and power-down. The devices have a TRACK pin to implement three types of tracking method: sequential, rati o-metric and simultaneous. TRACK simplifies the task of supply voltage tracking in a power system by enab[...]
-
Pagina 12
12 Figure 4: Sequential Power up Figure 5: Sequential Power down Ratio-Metric Implementation Ratio–metric is implemented by the selection of the resistor values of the voltage divider on the TRACK pin. Resistors R1 and R2, in Figure 6 determine the tracking met hod that is implemented. To simplify the tracking design, R2 initial set value equal 2[...]
-
Pagina 13
For Ratio-Metric applications that need the PS1 and PS2 outputs arrive regulation set point at same time, use equation 1 to calculate R1, set △ V=Vo set,PS1 –Vo set,PS2 and △ V will be negative. The waveforms of power up and down are showed in Figures 7 and 8. K Vref Vref V Vo R PS set 20 * ] ) [( 1 2 , − ∆ + = Ω -----------------------[...]
-
Pagina 14
14 For example, the PS1 Vo set,PS1 =5V, the PS2 Vo set,PS2 =3.3V, R1 is calculated as follows: K K R 303 . 10 20 * 32 . 1 ] 32 . 1 ) 3 . 1 3 . 3 [( 1 = − − = Ω Figure 9. Ratio–metric tra cking Power up Figure 10. Ratio–metric tracking Power down Simultaneous Implementation Similar to the ratio-metric implementation, simultaneous tracking [...]
-
Pagina 15
15 For type C (DNXXX0A0XXXX C ), th e simultaneous tracking can be accomplished by putting R1 equal to 30.1K Ω through Vo PS1 to the TRACK pin of PS2. Figure 12 shows the circuit diagram of Simultaneous start-up when Vo PS2 tracks the Vo PS1 (only for type C). R1 R2 TRACK Vo PS1 PS2 Vo PS2 PS1 Vin Vin ENABLE ENABLE To Tracking circuit 20K 30.1K Fi[...]
-
Pagina 16
16 Notes on the use of Track function: 1. For proper voltage tracking, first, The ENABLE On/Off pin of the PS2 module is lef t unconnected (or tied to GND for negative logic modules or tied to VIN for positive logic modules), so that the modules are ON by default and second applied input voltage to the PS1 and PS2. The TRACK pin is held at ground p[...]
-
Pagina 17
T est 1) T urn on the fan. 2) Adjust the input voltage to the desired operating point. 3) Set the electronic or resistive load at 50% of maximum load. 4) Change channel 1 to scope probe and measure across the dynamic R . 5) Set the switch SW2 to the converter ON. 6) Set channel 2 on the oscillo scope to be AC coupled and to 50mV/Div and for 5mS/Div[...]
-
Pagina 18
4. Connect a scope probe from channel 1 between the on/off control pin and re ference ground (SGND) on the Evaluation Board. 5. Set channel 2 on the oscilloscope to be DC coupled and within appropriate range fo r the output voltage. 6. Connect a coaxial cable from channel 2 to BNC2 on the Evaluation Board. 7. Set the T ime base to 2mS/Div 8. Set th[...]
-
Pagina 19
Appendix A- Evaluation Board Schematic 19[...]
-
Pagina 20
Appendix B - Evaluation Board Layout (Top View) Appendix C - Evaluation Board Layout (Bottom View) CONTACT DATA: www. delt aww.c om USA: Telephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964 Email: DCDC@delta-corp.com Europe: Telephone: France: +33 1 6485 1212 Germany: +49 89 370 62 897 UK: +44 777 195 6299 Fax: +33 1[...]