DeVillbiss Air Power Company SB-2-540 manuale d’uso
- Visualizza on-line o scarica il manuale
- 20 pagine
- 0.6 mb
Vai alla pagina of
Manuali d’uso simili
-
Air Compressor
DeVillbiss Air Power Company MGP-102D-2
16 pagine 0.32 mb -
Air Compressor
DeVillbiss Air Power Company MGP-FAC1025-2
16 pagine 0.26 mb -
Air Compressor
DeVillbiss Air Power Company MG7-OFTWIN
16 pagine 0.12 mb -
Air Compressor
DeVillbiss Air Power Company MG3-OLPORT-3A
16 pagine 0.25 mb -
Air Compressor
DeVillbiss Air Power Company 102D-1
16 pagine 0.32 mb -
Air Compressor
DeVillbiss Air Power Company MGP-FAC100-1
12 pagine 0.14 mb -
Air Compressor
DeVillbiss Air Power Company D26675
14 pagine 0.16 mb -
Air Compressor
DeVillbiss Air Power Company MGAT-1
12 pagine 0.24 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso DeVillbiss Air Power Company SB-2-540. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica DeVillbiss Air Power Company SB-2-540 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso DeVillbiss Air Power Company SB-2-540 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso DeVillbiss Air Power Company SB-2-540 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo DeVillbiss Air Power Company SB-2-540
- nome del fabbricante e anno di fabbricazione DeVillbiss Air Power Company SB-2-540
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature DeVillbiss Air Power Company SB-2-540
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio DeVillbiss Air Power Company SB-2-540 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti DeVillbiss Air Power Company SB-2-540 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio DeVillbiss Air Power Company in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche DeVillbiss Air Power Company SB-2-540, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo DeVillbiss Air Power Company SB-2-540, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso DeVillbiss Air Power Company SB-2-540. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Service Bulletin SB-2-540 OPERA TION MANUAL TRANS-TECH ® GRA VITY FEED SPRA YGUN English: Pages 2-9 MANUAL DE OPERACIÓN COMP ACT – PISTOLA PUL VERIZADORA POR GRA VEDAD TRANS-TECH ® Español: Páginas 10-17[...]
-
Pagina 2
Page 2 SB-2-540 IMPORTANT: Read and follow all instruc- tions and SAFETY PRECAUTIONS before using this equipment. DESCRIPTION The Compact Gravity feed Spraygun Kit complies to ATEX regulations 94/9/EC, protection level; II 2 G X, Suitable for use in Zones 1 and 2 . IMPORTANT: These Sprayguns are suit- able for use with both waterbased and solvent b[...]
-
Pagina 3
Page 3 SB-2-540 Patent No. 2372465 (GB) Ref. No. Description Part Number Qty. Options 1 Air Cap/Retaining ring COM-510 SP-100-510-K 1 +2 Nozzle SP-200S-**-K 1 14, 18, 22 e.g ** =14 =1.4 mm +3 Separator SP-626-K5 5 +4 Packing GTI-445-K2 2 5 Spreader Valve SP-403-K 1 6 Stud and Screw GTI-408-K5 5 7 Needle Adjusting Screw SP-614-K 1 +8 Spring SP-622-K[...]
-
Pagina 4
Page 4 SB-2-540 INSTALLATION Important: To ensure that this equipment reaches you in first class condition, protective coatings have been used. Flush the equipment through with a suitable solvent before use. 1. Attach air hose to connector (13). Recommended hose size 8 mm bore. The hose must be conductive and electrical bond from the spraygun to ea[...]
-
Pagina 5
Page 5 SB-2-540 1. Remove Adjusting Knob (7), Spring (8), and Needle (9). 2. Loosen Housing (10). 3. Remove Housing (10) and Airvalve Spring. 4. Remove Valve (11). 5. Using Service Tool SPN-7, engage groove behind the Valve Seat. 6. Remove Valve Seat. 7. Push out the Front Airvalve Seal with a finger. 8. Turn the Gun upside down and let the Seal fa[...]
-
Pagina 6
Page 6 SB-2-540 12. Fit Valve Seat to Gunbody. 13. Remove Rear Airvalve Seal from housing (10) with a hooked instrument. 14. Fit new Seal to Service Tool. 15. Fit Seal to Housing (10). 16. Replace Valve (11). 17. Replace Valve Spring and screw in Housing (10). 18. Tighten Housing. 19. Fit Needle (9). 20. Fit Spring (8) and Knob (7). 21. Adjust Need[...]
-
Pagina 7
Page 7 SB-2-540 *Most common problem. Left or right side horn holes plugged. Dirt on left or right side of fluid tip. Remedies for the top-heavy, bottom-heavy, right-heavy, and left-heavy patterns: 1. Determine if the obstruction is on the air cap or the fluid tip. Do this by making a test spray pattern. Then, rotate the cap one-half turn and spray[...]
-
Pagina 8
Page 8 SB-2-540 Tighten. Replace cup gasket. Clean. Adjust gun or reduce fluid flow. Mix properly or apply light coats. Hold gun at right angle to work and adapt to proper gun technique. Check distance. Normally approx. 8". Reduce air pressure and check spray pattern. Follow paint manufacturer's mixing instrs. Check distance. Normally app[...]
-
Pagina 9
Page 9 SB-2-540 NIOSH-Certified for respiratory protection in atmospheres not immediately dangerous to life. Consists of : 1 - Piercing Tool, 48 - Disposable Liners, 48 - Drain Bushings OMX-70-K48 Paint Cup Liner Kit Allows quick & easy clean-up. (1) Wall mount bracket included with GH-407. Holds standard paint cups, gravity feed guns and cups,[...]
-
Pagina 10
Página 10 SB-2-540 IMPORTANTE: Lea y siga todas las instrucciones y Precauciones de Seguridad antes de utilizar este equipo. DESCRIPCIÓN El Kit de Pistola Pulverizadora por Gravedad Compact cumple las normas ATEX 94/9/CE, nivel de protección; II 2 G X, Adecuado para el uso en las Zonas 1 y 2 . IMPORTANTE: Estas Pistolas pulver- izadoras son apro[...]
-
Pagina 11
Página 11 SB-2-540 Patente Nº 2372465 (GB) Nº Número Ref. Descriptión de Pieza Cant Opciones 1C asquillo de aire / Anillo de SP-100-510-K 1 retención COM-510 +2 Pico de fluido SP-200S-**-K 1 14, 18, 22 ej. ** =14 =1.4 mm +3 Separador SP-626-K5 5 +4 Empaquetadura GTI-445-K2 2 5 Válvula dispersora SP-403-K 1 6 Espiga y tornillo GTI-408-K5 5 7 [...]
-
Pagina 12
Página 12 SB-2-540 INSTALACIÓN Importante: Para asegurarse de que este equipo llega a usted en condiciones óptimas, se han utilizado recubrimientos protectores. Enjuague el equipo con un disolvente adecuado antes de su uso. 1. Acople el manguito de aire al conector (13). Tamaño de manguito recomendado: 8 mm diám. interior. El manguito debe ser[...]
-
Pagina 13
Página 13 SB-2-540 1. Retire el pomo de ajuste (7), el muelle (8), y la aguja (9). 2. Afloje el alojamiento (10). 3. Retire el alojamiento (10) y el muelle de la válvula de aire. 4. Retire la válvula (11). 5. Usando la herramienta de manteni-miento SPN-7, enganche la muesca detrás del asiento de la válvula. 6. Retire el asiento de la válvula.[...]
-
Pagina 14
Página 14 SB-2-540 12. Coloque el asiento de válvula en el cuerpo de la pistola. 13. Retire la junta de la válvula de aire del alojamiento (10) con un instrumento que tenga gancho. 14. Instale una junta nueva en la herramienta de manten- imiento. 15. Coloque la junta en el alojamiento (10). 16. Vuelva a colocar el husillo (11). 17. Vuelva a colo[...]
-
Pagina 15
Página 15 SB-2-540 *Problemas más comunes. Agujeros en el lado izquierdo o derecho de la horquilla obstruidos. Suciedad en el lado izquierdo o derecho de la punta del líquido. Corrección de los patrones pesados en la parte superior, inferior, el lado derecho e izquierdo. 1. Determine si la obstrucción está en el casquillo de aire o en la punt[...]
-
Pagina 16
Página 16 SB-2-540 Apriete. Reemplace la guarnición de la cubeta. Limpie. Ajuste la pistola o reduzca el flujo de fluido. Mezcle debidamente o aplique capas livianas. Sostenga la pistola en un ángulo correcto para trabajar y adáptela a una técnica debida. Verifique la distancia. Normalmente, aprox. 8 pulg. Reduzca la presión de aire y verifiq[...]
-
Pagina 17
Página 17 SB-2-540 Certificados por NIOSH para protección respira- toria en atmósferas que no implican riesgo inmediato para la vida. Compuesto por: 1 herramienta perforadora, 48 – forros desechables, 48 – Boquillas de descarga. Kit de forros de cubetas de pintura OMX-70-K48 Permite la limpieza rápida y fácil (1) Soporte de montaje mural i[...]
-
Pagina 18
Page 18 SB-2-540 NOTES[...]
-
Pagina 19
Página 19 SB-2-540 NOTAS[...]
-
Pagina 20
Page 20 SB-2-540 ITW Industrial Finishing DeVilbiss has authorized distributors throughout the world. For tech- nical assistance or the distributor nearest you, see listing below. U.S./Canada Technical Service Office: 195 Internationale Blvd., Glendale Heights, IL 60139 Toll-Free Telephone: 1-888-992-4657 (U.S.A. and Canada only) Toll-Free Fax: 1-8[...]