Emerson Process Management 430 DO manuale d’uso
- Visualizza on-line o scarica il manuale
- 24 pagine
- 0.74 mb
Vai alla pagina of
Manuali d’uso simili
-
Oxygen Equipment
Emerson Process Management OXYMITTER 4000
150 pagine 4.47 mb -
Oxygen Equipment
Emerson Process Management I-0320
47 pagine 5.21 mb -
Oxygen Equipment
Emerson Process Management 8732
190 pagine 9.44 mb -
Oxygen Equipment
Emerson Process Management 430 DO
24 pagine 0.74 mb -
Oxygen Equipment
Emerson Process Management OCX 8800
264 pagine 5.27 mb -
Oxygen Equipment
Emerson Process Management 3000
182 pagine 3.14 mb -
Oxygen Equipment
Emerson Process Management IM-106-340
176 pagine 4.1 mb -
Oxygen Equipment
Emerson Process Management IB106-340
138 pagine 2.02 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Emerson Process Management 430 DO. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Emerson Process Management 430 DO o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Emerson Process Management 430 DO descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Emerson Process Management 430 DO dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Emerson Process Management 430 DO
- nome del fabbricante e anno di fabbricazione Emerson Process Management 430 DO
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Emerson Process Management 430 DO
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Emerson Process Management 430 DO non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Emerson Process Management 430 DO e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Emerson Process Management in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Emerson Process Management 430 DO, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Emerson Process Management 430 DO, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Emerson Process Management 430 DO. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Model 430 DO Dissolv ed Oxygen Sensor Instruction Manual PN 51-430/rev .A May 1996[...]
-
Pagina 2
CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibili- ty of the user . DANGER HAZARDOUS AREA INST ALLA TION Installations near flammable liquids or in hazardous area locations must be carefully e[...]
-
Pagina 3
MODEL 430 DO T ABLE OF CONTENTS MODEL 430 DISSOL VED OXYGEN T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.0 Features and Applications ...................................................................................... 1 1.2 Operation ...............[...]
-
Pagina 4
T ABLE OF CONTENTS CONTINUED LIST OF FIGURES Number Title Page 1-1 Flow Through Senson Assemblies ......................................................................... 2 1-2 Optional Mounting Bracket ..................................................................................... 3 2-1 Code 01 and 02 Flow Through Installation .............[...]
-
Pagina 5
1 • LARGE ELECTROL YTE RESERVOIR allows up to twelve months and often longer between refills. • OPTIONAL MOUNTING BRACKET allows easy removal of the sensor from an aeration basin without the use of tools. • MODULAR PRESSURE COMPENSA TOR AND MEMBRANE RET AINER simplify recharg- ing and membrane replacement. • MEMBRANE RET AINER REPLACEMENT A[...]
-
Pagina 6
2 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS 1.3 A V AILABLE MODELS The Model 430-01 and -02 Sensor is a flow through assembly . The sensor is supplied in a 1-1/2 inch PVC tee for installation into a process line. The Model 430-03 Submersible Sensor is for use in those applications where the required flow velocity can be maintained wi[...]
-
Pagina 7
3 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS FIGURE 1-2 Optional Mounting Bracket DWG. NO. REV . 40043018 B MILLIMETER INCH[...]
-
Pagina 8
4 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS 1.5 ORDERING INFORMA TION. The Model 430 Dissolved Oxygen Sensor: Includes PVC body with integral, oxygen-permeable membrane of T eflon 1 . T emperature and pressure compensators included. Compatible with Model1 181DO. MODEL 430 DO DISSOL VED OXYGEN SENSOR CODE MOUNTING HARDW ARE 01 1-1/2?[...]
-
Pagina 9
5 MODEL 430 DO SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION 2.1 GENERAL. This section provides instructions for the Model 430 Dissolved Oxygen Sensor . 2.2 UNP ACKING AND INSPECTION. Inspect the ship- ping container and remove the sensor . Carefully check the sensor and its associated hardware for any dam- age. Report any damage to the car[...]
-
Pagina 10
6 MODEL 430 DO SECTION 2.0 INST ALLA TION FIGURE 2-1. Codes and 01 and 02 Flow Through Installation DWG. NO. REV . 40043001 G MILLIMETER INCH[...]
-
Pagina 11
7 MODEL 430 DO SECTION 2.0 INST ALLA TION FIGURE 2-2. Code 03 Sensor Dimensions DWG. NO. REV . 40043002 D MILLIMETER INCH[...]
-
Pagina 12
[...]
-
Pagina 13
9 MODEL 430 DO SECTION 3.0 MAINTENANCE SECTION 3.0 MAINTENANCE 3.1 GENERAL. Sensor maintenance consists of keep- ing the sensor clean, recharging the sensor and replacing the membrane. The sensor should be cleaned with clean water and a soft cloth. Make sure the membrane area is kept clean and free of any accumulation of dirt, algae, fungus, hair ,[...]
-
Pagina 14
10 4.1 GENERAL. This section contains troubleshooting data for the Model 430 Sensor Assembly . 4.2 TROUBLESHOOTING THE MODEL 430 DISSOL VED OXYGEN SENSOR. The majority of problems encountered in DO systems are because the sensor is either improperly maintained or has an inter- nal leakage causing improper temperature compen- sator resistance and hi[...]
-
Pagina 15
11 MODEL 430 DO SECTION 5.0 P ARTS LISTS SECTION 5.0 P ARTS LISTS 5.1 GENERAL. This section contains the replacement parts lists and illustrations for the Model 430 Sensor Assembly . Parts are keyed with an item number . Use the illustration to locate the item number for the part in question. Then refer to the accompanying parts list for the part n[...]
-
Pagina 16
12 MODEL 430 DO SECTION 5.0 P ARTS LISTS Part Number Description Qty . 3002384 Base 1 95501 16 O-ring (2-018)* 1 2002572 Reservoir housing assembly with membrane* 1 3002385 Retainer ,reservoir 1 9550133 O-ring (2-004) 1 3002382 Screw , vent 1 2002473 Recharge Kit 1 FIGURE 5-2. Model 430 Sensor Assembly DWG. NO. REV . 40043016 A[...]
-
Pagina 17
13 MODEL 430 DO SECTION 5.0 P ARTS LISTS FIGURE 5-3. Model 430 (Code 03) Dissolved Oxygen Sensor DWG. NO. REV . 40043015 A Figure & Part Item No. Number Description Qty . 5-3 SENSOR ASSY , Model 430 Dissolved Oxygen, submersion (Code 13) RF 2 9330020 Union, 3/4” NPT RF 3 3001617 Gasket 1 4 1001021 Sensor Assy (see Figure 5-2 for details) 1[...]
-
Pagina 18
14 MODEL 430 DO SECTION 5.0 P ARTS LISTS FIGURE 5-4. Model 430 (Code 04) Dissolved Oxygen Sensor DWG. NO. REV . 40043017 A Figure & Part Item No. Number Description Qty . 5-4 SENSOR ASSY , Model 430 Dissolved Oxygen, with agitator (Code 04) 1 2 9380053 Pump, submersible Attaching parts for item 2: 1 3 Screw , SPH SS (#8-32x3/8) 4 4 Screw , SPH [...]
-
Pagina 19
15 Model 430 DO SECTION 6.0 RETURN OF MA TERIAL SECTION 6.0 RETURN OF MA TERIAL 6.1 GENERAL. T o expedite the repair and return of instruments, proper communication between the cus- tomer and the factory is important. A return material authorization (RMA) number is required. Call (949) 757-8500. The "Return of Materials Request" form is p[...]
-
Pagina 20
A Worldwide Network of Sales and Service Emerson Process Management’s field sales of fices are your source for more information on the fill line of Rosemount Analytical products. Field sales personnel will work closely with you to supply technical data and application information. For more information, please contact your nearest Emerson Process [...]
-
Pagina 21
FROM: RETURN BILL TO: _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ CUSTOMER/USER MUST SUBMIT MA TERIAL SAFETY SHEET (MSDS) OR[...]
-
Pagina 22
[...]
-
Pagina 23
W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period. Goods are warranted for twelve (12) months[...]
-
Pagina 24
Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .r[...]