Encore electronic (66-501-1) manuale d’uso
- Visualizza on-line o scarica il manuale
- 24 pagine
- 2.69 mb
Vai alla pagina of
Manuali d’uso simili
-
DVR
Encore electronic ENUTV-2
21 pagine 1.07 mb -
Stereo Amplifier
Encore electronic 150
12 pagine 0.36 mb -
Network Card
Encore electronic ENUWI-N3
59 pagine 5.83 mb -
Network Card
Encore electronic Z8ENCORE000ZCO
43 pagine 1.35 mb -
Computer Drive
Encore electronic ENNHD-1GS
64 pagine 2.39 mb -
Switch
Encore electronic ENMGS-24+4
46 pagine 1.14 mb -
Network Router
Encore electronic ENDSL-A2+WIG2
5 pagine 0.13 mb -
Network Card
Encore electronic ENUWI-NX2
24 pagine 0.72 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Encore electronic (66-501-1). La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Encore electronic (66-501-1) o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Encore electronic (66-501-1) descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Encore electronic (66-501-1) dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Encore electronic (66-501-1)
- nome del fabbricante e anno di fabbricazione Encore electronic (66-501-1)
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Encore electronic (66-501-1)
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Encore electronic (66-501-1) non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Encore electronic (66-501-1) e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Encore electronic in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Encore electronic (66-501-1), come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Encore electronic (66-501-1), l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Encore electronic (66-501-1). Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
INSTRUCTION MANUAL P ART NO. A08591 Rev . 0 11/04 Copyright © 2004 Delta Machinery T o lear n more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (66-501-1) ESP AÑOL: PÁGINA 25 FRANÇAIS: P AGE 49[...]
-
Pagina 2
2- ENG A08591 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor [...]
-
Pagina 3
3- ENG A08591 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is norm[...]
-
Pagina 4
4- ENG A08591 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an[...]
-
Pagina 5
5- ENG A08591 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr[...]
-
Pagina 6
6- ENG A08591 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance [...]
-
Pagina 7
7- ENG A08591 Review and underst and all instructio ns and warnings in this manual. Become famil iar with the operation and contr ols of the air compresso r . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times . Do not operate the produc t when fatigue d or under the influenc e[...]
-
Pagina 8
8- ENG A08591 Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been e[...]
-
Pagina 9
Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the com[...]
-
Pagina 10
10- ENG A08591 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see [...]
-
Pagina 11
11- ENG A08591 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights,[...]
-
Pagina 12
Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : T ur n this switch ON to provide automatic power to the pressur e switch and OFF to remove power at the end of each use. Pressur e Switch: The pressure switch automatically starts the motor when the air tank pressur e drops below the factory[...]
-
Pagina 13
13- ENG A08591 How to Use Y our Unit How to Stop: 1. Set the On/Auto/Off lever to "OFF". Before Each Start-Up: 1. Place On/Auto/Off lever to "OFF". 2. Pull regulator knob out, tur n counterclockwise until it stops. Push knob in to lock in place. 3. Attach hose and accesso ries. NOTE: The hose or accessory will re quir e a quick [...]
-
Pagina 14
14- ENG A08591 Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D ra in T an k ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to make sure that [...]
-
Pagina 15
T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc moves freely ins[...]
-
Pagina 16
16- ENG A08591 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wrench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator an[...]
-
Pagina 17
17- ENG A08591 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress[...]
-
Pagina 18
18- ENG A08591 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in t[...]
-
Pagina 19
19- ENG A08591 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check th[...]
-
Pagina 20
20- ENG A08591 AIR COMPRESSOR DIAGRAM 21 5 13 16 4 3 9 10 1 15 6 14 12 11 8 7 7 17 20 2 18* * IMPORT ANT : Some models were built with a check valve and bushing reducer . If check valve needs to be replaced, remove the old check valve and reducer bushing before replacing with the pr eferr ed one piece check valve (Key 18).[...]
-
Pagina 21
21- ENG A08591 P ARTS LIST K e y N o P a r t N u m b er D es cr ip ti o n 1 TI A-41 50 Sa fety V alve 2 A0 6891 Dr ain V alv e 3 CA C-42 99 Wh eel 6 " (2 ) 4 CA C-60 Sh ould er Bo lt (2 ) 5 SS F-80 80- ZN Nu t Hex 3/8 -16 ( 2) 6 AC -034 5 Ha ndle 7 SS F-61 2 Scr ew #1 0-1 6 x 1(2 ) 8 AC -036 4 Mo lded Fo ot Bum per 9 Z- D272 27 Pr es su re Swi[...]
-
Pagina 22
22- ENG A08591 AIR COMPRESSOR PUMP DIAGRAM 9 3 18 5 6 8 14 17 15 1 2 25 4 T o rque 49-55 in.-lbs. T o rque 30-45 in.-lbs. T o rque 10 in.-lbs. Max 9-13 9-12 9-8 9-9 9-10 9-11 7 10 22 16 24 T orque 30 in.-lbs.[...]
-
Pagina 23
23- ENG A08591 P ARTS LIST Key No. Part No. Description ★ 1 ----- Shroud - Left ★ 2 ----- Shroud - Right 3 ----- Cylinder Head ▲ 4 CAC-1212 T ube Seal ▲ 5 ----- Head Gasket 6 Z-A08548 V alve Plate Assembly 7 DAC-269 Outlet T ube ▲ 8 ----- Gasket 9 Z-A04647 Sub Pump Assembly ◆ 9-8 ----- Rod Assembly • 9-9 ----- Pre-Formed Compression R[...]
-
Pagina 24
24- ENG A08591 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 [...]