Extron electronic MTP 15HD RSA manuale d’uso
- Visualizza on-line o scarica il manuale
- 20 pagine
- 1.94 mb
Vai alla pagina of
Manuali d’uso simili
-
Network Card
Extron electronic MC104 IP
23 pagine 2.34 mb -
Network Card
Extron electronic IPL M PDP-ES
1 pagine 0.09 mb -
Network Card
Extron electronic RGB 468xi
36 pagine 1.42 mb -
Network Card
Extron electronic RGB 160
17 pagine 1.47 mb -
Network Card
Extron electronic SVHSM-BNCM 1
1 pagine 0.18 mb -
Network Card
Extron electronic RGB 464xi
36 pagine 1.42 mb -
Network Card
Extron electronic IRCM
1 pagine 0.09 mb -
Network Card
Extron electronic HSA 200CE
3 pagine 0.67 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Extron electronic MTP 15HD RSA. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Extron electronic MTP 15HD RSA o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Extron electronic MTP 15HD RSA descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Extron electronic MTP 15HD RSA dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Extron electronic MTP 15HD RSA
- nome del fabbricante e anno di fabbricazione Extron electronic MTP 15HD RSA
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Extron electronic MTP 15HD RSA
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Extron electronic MTP 15HD RSA non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Extron electronic MTP 15HD RSA e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Extron electronic in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Extron electronic MTP 15HD RSA, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Extron electronic MTP 15HD RSA, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Extron electronic MTP 15HD RSA. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
68-1644-01 Rev. A 08 10 MTP Twisted Pair Transmitter and Receiver Modular Boards PowerCage ™ MTP 15HD RSA Series User Guide PowerCage Products[...]
-
Pagina 2
This symbol is intended to alert the user of important operating and mainte- nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock. Caution Read Instructions ?[...]
-
Pagina 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference r eceived, including interfer ence that may cau[...]
-
Pagina 4
Contents Introduction ............................................ 1 About this Guide ............................................. 1 About the PowerCage MTP 15HD RSA T ransmitters and Receivers .............................. 1 Features ........................................................... 2 Installation and Operation ..................... 4 [...]
-
Pagina 5
Intr oduction • About this Guide • About the PowerCage ™ MTP 15HD RSA T ransmitters and Receivers • Features About this Guide This guide contains information about the following Extron ® PowerCageMTP 15HD RSA modular board-designed twisted pair transmitters and r eceivers for the PowerCage Modular Power Enclosures: • PowerCage MTP T 15HD[...]
-
Pagina 6
The transmitter board also featur es EDID emulation, wher eby the correct r efr esh rate and resolution is applied to the incoming computer signal, ensuring a pr oper image output display . T wo DIP switches on the board allows the user to set the refr esh rate to 50 or 60 Hz (default is 60 Hz) using switch #1. The second switch controls the RS-232[...]
-
Pagina 7
• PowerCage MTP T 15HD RSA transmits high resolution video and mono audio or RS-232 signals 600 feet (185 meters) or more over a single twisted pair cable. о Inputs: Female 15-pin HD connector for video, 5-pole captive screw connector for audio input, 3-pole captive screw connector for RS-232 communication. о Output: Female RJ-45 connector о E[...]
-
Pagina 8
Installation and Operation This section describes the installation and operation of the PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ, including: • Installing the Boards into the PowerCage Enclosur e • Board Connections, LEDs, and Rear Panel Featur es • PowerCage Front Panel Port, Contr ol, and Indicators • Board Setup and Operation Insta[...]
-
Pagina 9
3. Carefully slide the boar d into the slot, aligning the two tabs on the lower fr ont end of the board with the matching ports in the enclosur e. Push the boar d firmly into place. Tighten the screws to secure the boar d in place. NOTE: Use a tool to fully tighten the screws after initial installation and subsequent removal and r eplacement of th[...]
-
Pagina 10
NOTE: The receiver auto-detects whether the signal on the audio/RS-232 pair of the TP input is audio or RS-232. It then converts the signal content accordingly , and outputs the signals on the appropriate pins of this connector . Receive (Rx) T ransmit (Tx) Ground ( ) Bidirectional Mono A udio Output RS-232 Output Tip Ring Sleev e Rx Tx RS-232 Devi[...]
-
Pagina 11
Maximum T ransmitter to Receiver Distance — Analog Signals at 60 Hz Video Format With Pre-Peak Of f. Feet (Meters) With Pre-Peak On. Feet (Meters) Max. Distance (High Quality). Feet (Meters) Max. Distance (V ariable Quality). Feet (Meters) Composite, S-video, Component Video 800 (245) 1000 (300) 640 x 480 <300 (90) >350 (105) 700 (215) 750 [...]
-
Pagina 12
PowerCage Fr ont Panel Port, Control, and Indicators The following features ar e on the fr ont panel of the PowerCage enclosure. PowerCage 1600 COMM 1 POWER ALARM 2 3 14 15 16 1 PSU 2 PSU 1 FAN 2 FAN COMM SELECT CONFIG TEMP 3 4 5 6 2 1 Figure 7. PowerCage Fr ont Panel a Comm LED (Slots 1-16) — This LED lights to indicate that the board at this lo[...]
-
Pagina 13
Boar d Setup and Operation On the MTP T 15HD RSA board there ar e two DIP switches (switch #1 is for r efresh rate, switch #2 is for audio/RS-232), and a 16-position rotary encoder for EDID selection. The factory set defaults for these are: • DIP switch #1 is 60 Hz (down) • DIP switch #2 is audio (down) • EDID encoder is 1024x768 (position 2)[...]
-
Pagina 14
Changing the MTP T 15HD RSA Board Settings Change any of the four active DIP switches to the settings as shown in the table below . Switch Position Switch #1 Setting Switch #2 Setting Switch #3 Setting Switch #4 Setting Switch #5 Setting Switch #6 Setting Up/On H+ V+ Bidirectional S-Video green = luma blue = chroma N/A N/A Down/Off (default) H- V -[...]
-
Pagina 15
2. Noting the color that is shifted furthest left , press the select button accor dingly to select that color (see table above). The corresponding LED lights. 3. Viewing the image, slowly rotate the Adjust knob until the selected color converges with the color furthest right. 4. Repeat steps 2 and 3 for the remaining color until all thr ee colors a[...]
-
Pagina 16
Refer ence Information This section provides the specifications and part numbers for the PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ modular boards. • Specifications • Part Numbers Specifications Video — PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQ Gain ............................................... Unity Number/signal type [...]
-
Pagina 17
Sync — PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQ Input/output type ........................... RGBHV , RGBS, RGsB, RsGsBs Standards ....................................... NTSC 3.58, NTSC 4.43, P AL, SECAM Input level (transmitter) .................. 3.5 V to 5.5 Vp-p, unterminated Output level (receiver) .................... 4.0 V t[...]
-
Pagina 18
General Recommended cable type .............. Extron Enhanced Skew-Fr ee ™ A/V UTP , CA T 5/5e/6 (shielded or unshielded) Power consumption* ..................... 1 o r 2 * ( pos iti ve- neg ati ve) , 1 00 V AC t o 2 40 V AC, 50- 60 Hz; in terna l, hot -sw app abl e * A redundant power supply is optional. Each MTP board at 115 V AC, 60 Hz MTP T 1[...]
-
Pagina 19
Part Numbers PowerCage MTP 15HD RSA Part Numbers The PowerCage MTP 15HD RSA boards must be installed in a PowerCage 1600 enclosur e. PowerCage Boards Part number PowerCage MTP T 15HD RSA 70-817-01 PowerCage MTP R 15HD RSA SEQ 70-818-01 Included Parts These items are included in each or der for a PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ: Incl[...]
-
Pagina 20
Extron USA - W est Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500 +1.714.491.1517 F AX Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794 +1.919.863.1797 F AX Extron Eur ope +800.3987.6673 Inside Europe Only +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +800.7339.8766 Inside Asia Only +65.6383.4400 +65.638[...]