Guardian Technologies 005241 manuale d’uso
- Visualizza on-line o scarica il manuale
- 72 pagine
- 7.34 mb
Vai alla pagina of
Manuali d’uso simili
-
Portable Generator
Guardian Technologies 4758
151 pagine 9.96 mb -
Portable Generator
Guardian Technologies 5633
1 pagine 0.78 mb -
Portable Generator
Guardian Technologies 4759
151 pagine 9.96 mb -
Portable Generator
Guardian Technologies 004724-0
52 pagine 4.06 mb -
Portable Generator
Guardian Technologies 005336-1, 005337-1
64 pagine 4.3 mb -
Portable Generator
Guardian Technologies 5617
1 pagine 0.85 mb -
Portable Generator
Guardian Technologies 04456-2
60 pagine 5.1 mb -
Portable Generator
Guardian Technologies 005241
72 pagine 7.34 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Guardian Technologies 005241. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Guardian Technologies 005241 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Guardian Technologies 005241 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Guardian Technologies 005241 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Guardian Technologies 005241
- nome del fabbricante e anno di fabbricazione Guardian Technologies 005241
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Guardian Technologies 005241
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Guardian Technologies 005241 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Guardian Technologies 005241 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Guardian Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Guardian Technologies 005241, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Guardian Technologies 005241, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Guardian Technologies 005241. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual 7, 10, 13 and 16kW Air -cooled, A utomatic Standby Generator s Models: 005240, 005280 (6 kW NG, 7 kW LP) 005241, 005281 (9 kW NG, 10 kW LP) 005242, 005282 (13 kW NG, 13 kW LP) 005243, 005244, (15 kW NG, 16 kW LP) 005283, 005284 D ANGER DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION[...]
-
Pagina 2
I NTRODUCTION Thank you for purchasing this model of the Guardian product line by Generac P ower Systems Inc. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads dur - ing a utility power failure. This unit is factory installed in an all-weath[...]
-
Pagina 3
T able of Cont ents Air-cooled Generators 1 Introduction ........................ Inside F ront Cover Read This Manual Thoroughly ........................ IFC Contents .......................................................... IFC Operation and Maintenance ............................ IFC How to Obtain Service ..................................... [...]
-
Pagina 4
2 Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental ru[...]
-
Pagina 5
3 ELE CTR ICAL HA Z AR DS All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, terminals, connections, etc.,[...]
-
Pagina 6
D ANGER Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and r egu- lations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. This standby generator set is ready for installa- tion with a factory supplied and pre -mo[...]
-
Pagina 7
Section 1 — General Information Air-cooled Generators 5 1.4 TH E GEN ER A T OR Air Filter Cover Control Pan el Fuel Regulator Battery Compartment Oil Filter Exhaust Enclosure Oil Dipstick Data Decal Composite Base Fuel Inlet (Back) Air Filter Cover Control Panel Fuel Regulator Battery Compartment Oil Filter Exhaust Enclosure Oil Dipstick Data Dec[...]
-
Pagina 8
6 Section 1 — General Information Air-cooled Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 05240 & 05280 05241 & 05281 05242 & 05282 05243 & 05244 05283 & 05284 Rated Max. Continuous 6,000 NG/7,000 LP 9,000 NG/10,000 LP 13,000 NG/13,000 LP 15,000 NG/16,000 LP P ower Capacity (W atts*) Rated V oltage 120/240 120/2[...]
-
Pagina 9
7 1.6 S Y S TEM SE T LED The “System Set ” LED is lit when all of the following conditions are true: 1. The AUTO/OFF/MANU AL switch is set to the A UTO position. 2. The utility voltage being supplied to the unit is being sensed by the PCB. If the utility sense volt - age is not connected to the unit or if it is below approximately 150-160 volts[...]
-
Pagina 10
1.9 R E C ON F IGU R I NG TH E F U E L SYST E M 1.9.1 7 KW , 4 1 0CC ENGIN E T o reconfigure the fuel system from NG to LP , follow these steps (Figure 1.4): NOTE: The primary regulator for the propane supply is NOT INCL UDED with the generator . A fuel pres - sure of 10 to 12 inches of water column (0.36 to 0.43 psi) to the fuel inlet of the gener[...]
-
Pagina 11
9 Figure 1.5 - 10kW , GT -530 (Inlet Hose Slid Back) Figure 1.6 - 10kW , GT -530 (Inlet Hose Slid Back) Figure 1.7 - 13/16kW , GT -990 (Airbox Cover Removed) Figure 1.8 - 13/16kW , GT -990 (Airbox Cover Removed) 1.1 0 L OCA TION 1.1 0.1 GEN ER A T OR Install the generator set, in its protective enclosure, outdoors , where adequate cooling and venti[...]
-
Pagina 12
10 Install the generator as close as possible to the fuel supply , to reduce the length of piping . Install the generator as close as possible to the transfer switch. REMEMBER THA T LA WS OR CODES MA Y REGULA TE THE DIST ANCE AND LOCA TION . The genset must be installed on a level surface. The base frame must be level within two (2) inches all arou[...]
-
Pagina 13
11 Figure 1.10 – Battery Cable Connections NOTE: In areas where temperatures regularly fall below 10° F (-12° C) it is recommended that a pad type battery heater be installed to aid in cold climate starting (see Specifications). NOTE: The generator is equipped with a battery trickle charger that is active when the unit is set up for automatic o[...]
-
Pagina 14
12 2.1 B EFOR E I N ITIAL S T ART -UP NOTE: These units have been run and tested at the fac- tory prior to being shipped and do not require any type of break -in. Before starting, complete the following: 1. Set the generator’s main circuit breaker to its OFF (or OPEN) position. 2. Set the generator's A UTO/OFF/MANU AL switch to the OFF posit[...]
-
Pagina 15
13 Section 2 — Post Installation Start-up and Adjustments Air-cooled Generators 2.4 GEN ER A T OR T ESTS U N DER L O AD T o test the generator set with electrical loads applied, proceed as follows: 1. Set generator’s main circuit breaker to its OFF (or OPEN) position. 2. T urn OFF all breakers on the load center of the transfer box (T1 and T2).[...]
-
Pagina 16
14 1. T urn off utility power to the main distribution panel in the house. This can be done by switching the service main breaker to the off or open posi- tion. 2. Allow the generator to start. Before loading the generator , confirm that the No Load F requency , with the roof open and door off, is set to 63-63.5 Hz. Transfer load to emergency circu[...]
-
Pagina 17
15 4. Connect a frequency meter across the generators AC output leads. 5. T urn the primary adjust screw to obtain a fre - quency reading of 61.5 Hertz. T urn the secondary adjust screw to obtain a frequency of 62.5 Hz. 6. When frequency is correct at no load, check the AC voltage reading . If voltage is incorrect, the volt - age regulator may requ[...]
-
Pagina 18
16 3.1.4 CHOKE OP ER A TION 1. 990 engines have an electric choke in the air box that is automatically controlled by the electronic control board. 2. 530 engines have an electric choke on the divider panel air inlet hose that is automatically con- trolled by the electronic control board. 3. 410 engines do not have a choke. 3.2 AUT OMA TIC TR ANSF E[...]
-
Pagina 19
17 Section 3 — Operation Air-cooled Generators 4. Use the manual transfer handle inside the trans- fer switch to move the main contacts to their ST ANDBY position, i.e., loads connected to the standby power source (Figure 3.2). 5. T o crank and start the engine, set the A UTO/OFF/ MANU AL switch to MANU AL. 6. Let the engine stabilize and warm up[...]
-
Pagina 20
18 Low speed exercise will be handled as follows: 1. The standard start sequence will be initiated. 2. The unit will run at 2,400 RPM. 3. If utility is lost during exercise, the controller will do the following: • W ait 10 seconds for utility to return. • If utility returns within 10 seconds, continue to exercise at 2,400 RPM. • If utility is[...]
-
Pagina 21
19 3.6.5 R PM SENSOR F AIL UR E During cranking, if the board does not see a valid RPM signal within three (3) seconds, it will shut down and latch out on RPM sensor loss. During running, if the RPM signal is lost for one full second the board will shut down the engine, wait 15 seconds, then re - crank the engine. If an RPM signal is not detected w[...]
-
Pagina 22
20 Figure 4.3 — Oil Dipstick and Fill, 10kW Oil Dipstick Oil Fill Figure 4.4 — Oil Dipstick and Fill, 13kW and 16kW Oil Dipstick Oil Fill 4.3 CHANGI NG TH E ENGI N E OI L 4.3.1 OI L CHANGE INTERV AL S See the "Service Schedule" section. 4.3.2 ENGI NE OI L R EC OMM EN D A TIONS Use all season SAE 5W -30 synthetic oil or use SAE 30 oil [...]
-
Pagina 23
21 4.4 CHANGI NG TH E ENGI N E AI R CLEAN ER 4.4.1 7 , 1 3, AN D 1 6KW GEN ERA T ORS See Figures 1.1 and 1.2, for the location of the air cleaner . Use the following procedures (Figure 4.6, 7kW ; Figure 4.8, 13/16kW): 1. Lift the roof and remove the door . 2. T urn the two screws counterclockwise to loosen. 3. Remove the cover and air filter . 4. W[...]
-
Pagina 24
22 3. Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.76 mm (0.030 inch) for 7 and 10kW ; and 1.02 mm (0.040 inch) for 13/16 kW by carefully bending the ground electrode (Figure 4.9). Figure 4.9 – Setting the Spark Plug Gap 4.6 B A TTER Y MAI NTENANCE The battery should be inspected per the "Service Schedule" sec[...]
-
Pagina 25
Remove spark plug wires and position wires away from plugs. Remove spark plugs. Make sure the piston is at T op Dead Center (TDC) of its compression stroke (both valves closed). T o get the piston at TDC, remove the intake screen at the front of the engine to gain access to the flywheel nut. Use a large socket and socket wrench to rotate the nut an[...]
-
Pagina 26
24 4.1 0 C OR ROSION PRO TECTION P eriodically wash and wax the enclosure using auto - motive type products. F requent washing is recom- mended in salt water/coastal areas. Spray engine linkages with a light oil such as WD -40. 4.1 1 OUT OF SERVICE P ROCEDU R E 4.1 1.1 R EMOV AL F ROM SERVICE If the generator cannot be exercised every seven days, a[...]
-
Pagina 27
25 Section 4 — Maintenance Air-cooled Generators 4.1 2 SERVICE SCHEDU LE A TTENTION: It is recommended that all service work be performed by the nearest Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify Dealer Y = Y early if Repair is Needed. FUEL F[...]
-
Pagina 28
5.1 TROU B LE SHOO TI NG GU I DE Problem Cause Correction The engine will not crank. 1. F use blown. 1. Correct short circuit condition, replace 15A fuse in generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables. as necessary . 3. Defective starter contactor . (7 kW) 3. * 4. Defective starter motor . 4.[...]
-
Pagina 29
27 27 Section 6 — Notes Air-cooled Generators[...]
-
Pagina 30
28 Section 6 — Notes Air-cooled Generators[...]
-
Pagina 31
29 Section 6 — Notes Air-cooled Generators[...]
-
Pagina 32
30 Section 7 — Mounting Dimensions Air-cooled Generators Drawing No. 0F9424[...]
-
Pagina 33
31 NEUTRAL CONNECTION INSIDE SWITCH XB NO C1 COM XA VR1 NC NC COM C2 VR2 NO TR 194 23 1 7 4 79 36 9 F2 CIRCUIT 10 BLACK (MAIN 1) 12Vdc TRANSER COIL RED (MAIN 2) NEUTRAL (WHITE) NEUTRAL (WHITE) 23 OPEN F1 N2 N1 194 23 BLACK RED N2 N1 194 240V AC TO TO GENERA T OR OUTPUT PA N E L MAIN DISTRIBUTION LC-CIRCUIT BREAKER (LOADS) F1,F2-5A, 600V FUSE XA,XB-[...]
-
Pagina 34
32 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 1 0, 1 3 & 1 6kW , V- T win – Drawing No. 0F782 2 TX - TRANSFORMER, 16 V ac 56 V A & 16 V ac 1 V A (DUAL SEC.) HTO SP1 85 IM1 CB - MAIN OUTPUT BREAKER BA - BRUSH ASSEMBL Y BCR - BA TTERY CHARGE RELA Y SC - ST ARTER CONT ACTOR ICT - IDLE CURRENT TRANSFORMER IC - INLI[...]
-
Pagina 35
33 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 1 0, 1 3 & 1 6kW , V- T win – Drawing No. 0F782 2 0 4 CLOSEST TO BEARING OUTPUT TO TRANSFER 240V GENERA TOR SWITCH CONT ACTOR 6 2 N2 N1 VOLT AG E REGULA TOR 0 0 2 4 6 0 22 11 4 11 SW2 1 MANUAL SW1 15A AUTO 1a CONNECTION CUSTOMER 15B GRD 1 0 77 6 22 66 11 0 1 C2 2 5 4 3 [...]
-
Pagina 36
34 Section 8 — Electrical Data Air-cooled Generators Electrical Schematic – 1 0, 1 3 & 16kW , V - Twin – Drawing No. 0F7 823 225B 224B 13 15 56 16 86 15A 224 15B PRINTED CIRCUIT 11 13 14 12 CONTROL BOARD 5 8 9 10 6 7 J1 2 3 4 1 VOLT AG E REGULA TOR ELECTRONIC MANUAL SW2 AUT O 239 15 SW1 194 194 15A 15A 194 6 2 4 0 4 11 22 56 0 0 13 0 CHAR[...]
-
Pagina 37
35 Section 8 — Electrical Data Air-cooled Generators Electrical Schematic – 1 0, 1 3 & 16kW , V - Twin – Drawing No. 0F7 823 WINDING 22 22 225A 56V A 225A 224A 224 225 225 14 224A 1V A 14 TX 0 0 23 224B 225B 194 0 1 7 2 16 14 0 0 4 6 0 0 0 BCR 6 7 3 9 4 9 22 0 FS1 62 0 0 11 16 13 BCR - BA TTERY CHARGE RELA Y CB - CIRCUIT BREAKER, MAIN OUT[...]
-
Pagina 38
36 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 7kW , Single Cylinder – Drawing No. 0F7 820 CB - MAIN OUTPUT BREAKER BA - BRUSH ASSEMBL Y BCR - BA TTERY CHARGE RELA Y SC - ST ARTER CONT ACTOR ICT - INTERCONNECTION TERMINALS IC - INLINE CONNECTOR HTO - HIGH OIL TEMPERA TURE SWITCH GRD 2 - GROUND CONNECTIONS A T ENGINE FS [...]
-
Pagina 39
37 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 7kW , Single Cylinder – Drawing No. 0F7 820 0 4 CLOSEST TO BEARING OUTPUT TO TRANSFER 240V GENERA TOR SWITCH CONT ACTOR 6 2 15A 0 239 15A 239 N2 N1 0 11 SW2 1 MANUAL SW1 15A AUTO 1a CONNECTION CUSTOMER 194 GRD 1 0 77 6 22 66 11 1 C2 2 5 4 3 225B CONTROL P ANEL BO X 224A 224[...]
-
Pagina 40
38 Section 8 — Electrical Data Air-cooled Generators Electrical Schematic – 7kW , Single Cylinder – Drawing No. 0F7 821 225B 224B 13 86 15A 224 0 15B PRINTED CIRCUIT 11 13 14 12 CONTROL BOARD 5 8 9 10 6 7 J1 2 3 4 1 VOLT AG E REGULA TOR ELECTRONIC MANUAL SW2 AUT O 239 15 SW1 194 194 15A 15A 194 6 2 4 0 4 11 22 0 0 13 0 CHARGER 2 1 0 BA TTERY [...]
-
Pagina 41
39 Section 8 — Electrical Data Air-cooled Generators Electrical Schematic – 7kW , Single Cylinder – Drawing No. 0F7 821 WINDING 22 22 225A 56V A 225A 224A 224 225 225 14 224A 1V A 14 TX 0 0 23 224B 225B 194 0 1 7 2 56 14 0 0 4 6 0 0 0 BCR 6 7 3 9 4 9 22 0 FS 62 0 0 11 56 13 BCR - BA TTERY CHARGE RELA Y CB - CIRCUIT BREAKER, MAIN OUTPUT IM - I[...]
-
Pagina 42
40 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 8, 1 0, 1 2 and 1 6 Circuit Load Center – Drawing No. 0F90 7 0-A[...]
-
Pagina 43
41 Section 8 — Electrical Data Air-cooled Generators Wiring Diagram – 8, 1 0, 1 2 and 1 6 Circuit Load Center – Drawing No. 0F90 7 0-A[...]
-
Pagina 44
42 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators Enclosure – Drawing No. 0F9431 -B SHEET MET AL P AINT/MA TERIAL CODE LEGEND The follo wing exploded vie ws contain part numbers of various sheet metal components. Only the base par t number is listed. When ordering sheet metal, the correct color and material information must [...]
-
Pagina 45
43 ITEM P ART NO . QTY . DESCRIPTION 1 0F9653 1 P AD , 24 X 48” WITH MOUNTING HOLES 2 045771 4 NUT HEX M8-1.25 3 022129 4 W ASHER LOCK 5/16 022129 5 WASHER LOCK 5/16 (7KW) 4 022145 8 W ASHER FLA T 5/16 5 043107 4 SCREW HHC M8-1.25 X 25 6 090388 15 SCREW T APTITE M6-1.0 X 12 7 0D3700 24 NUT , LOCKING FLANGE M6-1.0 (7KW) 8 0D4662 14 SCREW HHTR 5/16[...]
-
Pagina 46
44 32 44 19 29 3 17 27 29 8,9 37 22 10 27 15 43 44 20 6 13 17 35 21 5 34 15 25 23 36 30 12 26 7 32 28 2 39 17 23 4 25 18 13 17 14 16 40 15 33 24 31 44 38 32 44 43 1 41 31 11 42 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators Control Panel – Drawing No. 0F9695-B[...]
-
Pagina 47
45 ITEM P ART NO . QTY . DESCRIPTION 1 0E7886A 1 CIRCUIT BREAKER 30A X 2P 240V (7KW) 0E7886D 1 CIRCUIT BREAKER 45A X 2P 240V (10KW) 0E7886K 1 CIRCUIT BREAKER 55A X 2P 240V (13KW) 0E7886J 1 CIRCUIT BREAKER 65A X 2P 240V (16KW) 2 0A1801 1 ASSEMBL Y , BA TTER Y CHARGER ENGINE 3 0F9719 1 ASSEMBL Y , POTTED REGULA TOR 4 0C2174 1 RELA Y , 12V 25A SPST (N[...]
-
Pagina 48
46 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators T ransfer Switch Assembly – Drawing No. 0F9 77 4-A[...]
-
Pagina 49
47 ITEM P ART NO . QTY . DESCRIPTION 1 0F8278 1 BOX LOAD CENTER 2 0D4800 1 CO VER, 8 CIRCUIT LOAD CENTER 0F5211 1 CO VER, 10 CIRCUIT LOAD CENTER 0D3092 1 CO VER, 12 CIRCUIT LOAD CENTER 0F8312 1 COVER, 16 CIRCUIT LO AD CENTER 3 0C2237 1 TRANSFER SWITCH HOME ST ANDBY 100A 2P 250V 3A 077220 1 COIL UTILITY 3B 077220A 1 COIL ST ANDBY 3C 082574 1 INSULA [...]
-
Pagina 50
48 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 3 & 1 6kW, G T -990 Eng ine – Drawing No. 0F9430-C - Part 1[...]
-
Pagina 51
49 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0E9843 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 3 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372B 1 SEP ARA TOR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S 8 071983 4 RET AINER, PIST ON P[...]
-
Pagina 52
50 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 3 & 1 6kW, G T -990 Eng ine – Drawing No. 0F9430-C - Part 2[...]
-
Pagina 53
51 ITEM P ART NO . QTY . DESCRIPTION 64 022145 1 W ASHER FLA T M8 – 5/16 65 0C5136A 2 KNOB, AIR CLEANER 66 0C3024 1 CO VER, AIRBOX NG/LP 67 0C3040 1 PRE-CLEANER, 68 0C8127 1 ELEMENT , AIR CLEANER 69 0F9255 1 ASSEMBL Y , MIXER/AIRBO X 990 70 0E9582 4 SCREW SHLDR(8MM) M6-1.0 X 21 71 0D4417 4 W ASHER,RUBBER 1/4" X 1/8" THICK 72 0G0767A 2 S[...]
-
Pagina 54
52 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 0kW , GT -53 0 Eng ine – Drawing No. 0F9429-C - Part 1[...]
-
Pagina 55
53 ITEM P ART NO . QTY . DESCRIPTION 1 0E9428B 1 CRANKCASE 2 0E3812 2 SEAL D 35 X 48.2 3 0C8566 2 SCREW HHFC M6 – 1.0 X 20 4 0E9367A 1 ASSY , BREA THER 5 0E9366 1 GASKET BREA THER ASSY 6 0E9304 1 CYLINDER HEAD 1 7 0E9334C 1 CO VER, ROCKER PLAIN 8 076390 4 PISTON PIN RET AINER RING 9 076389 2 PIST ON PIN 10 088057 2 PIST ON 11 088411 2 PIST ON RIN[...]
-
Pagina 56
54 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 0kW , GT -53 0 Eng ine – Drawing No. 0F9429-C - Part 2[...]
-
Pagina 57
55 ITEM P ART NO . QTY . DESCRIPTION 58 022097 3 W ASHER LOCK M6-1/4 59 0E9561 1 INT AKE AD APTER 60 0E9472 1 GASKET , AIRBO X T O CARB/MIXER 61 0E9471 1 GASKET , MANIFOLD TO CARB/MIXER 62 078643B 4 BOL T , CARB MOUNT M6 – 1.0 X 85 63 0D9784 1 NUT HEX LOCK M3 – 0.5 64 0E9584 1 ASSY , CONTROLLER 65 0D6342 1 BALL STUD , 10 MM 66 0E9587 1 ASSY , T[...]
-
Pagina 58
56 32 23 34 35 36 45 39 33 20 19 18 43 44 46 11 49 29 37 27 28 30 31 17 52 47 48 24 38 26 22 40 41 25 25 50 15 53 14 21 12 51 13 54 16 1 6 1 2 11 10 42 5 7 9 8 3 4 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 7kW , GN-4 10 Engine – Drawing No. 0F9428 - P art 1[...]
-
Pagina 59
57 ITEM P ART NO . QTY . DESCRIPTION 1 0E3221 1 ASSEMBL Y , CONNECTING ROD 2 0E1466 1 PIN, PISTON D20 3 021533 1 SET , PIST ON RING 90MM 4 0E2985 1 PIST ON, HC 5 071983 2 RET AINER, PIST ON PIN 20 6 0E8440 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GOVERNOR RC45 8 078658 1 PIN, “R” GOVERNOR ARM 9 078659 2 W ASHER, GO VERNOR ARM[...]
-
Pagina 60
58 19 20 41 7 12 6 6 6 21 43 23 15 16 14 18 17 31 30 27 2 45 38 22 6 5 40 3 39 28 13 11 47 44 29 8 6 24 10 51 9 50 46 49 18 25 32 34 26 18 1 35 34 33 48 52 10 42 4 6 36 37 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 7kW , GN-4 10 Engine – Drawing No. 0F9428 - P art 2[...]
-
Pagina 61
59 ITEM P ART NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLOW CHROME 2 0D2922 1 HOUSING, BLOWER 3 0F8426 1 TUBE, DIPSTICK 4 0C9997 1 GUARD , F AN 5 088434 1 WRAPPER, BOTT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLOW CHROME 7 0C4176A 1 WRAPPER, T OP 8 0D9004A 1 ASSY , ST AR TER 9 059985 2 SCREW , SHC M8-1.25 X 45 G12.9 10 022129[...]
-
Pagina 62
60 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 7kW , GN-4 10 Engine – Drawing No. 0F9422-B[...]
-
Pagina 63
61 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 7kW , GN-4 10 Engine – Drawing No. 0F9422-B ITEM P ART NO . QTY . DESCRIPTION 1 0F8186 1 ADAPT OR, ENGINE 2 0F5540H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0F7774A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8” CUR VED BLADE 6 0F6591 1 MUFFLER 7 0F8078 1 T AIL PIPE, MUFFLER 9 056482 1[...]
-
Pagina 64
62 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 0, 1 3, and 16kW , V -twin Generators – Drawing No. 0F9423-C[...]
-
Pagina 65
63 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 0, 1 3, and 16kW , V -twin Generators – Drawing No. 0F9423-C ITEM P ART NO . QTY . DESCRIPTION 1 0F8186 1 ADA TOR, ENGINE 2 0F6694 1 ST A TOR (16KW) 0F5538 1 ST A TOR (13KW) 0F7548 1 ST A TOR (10KW) 3 0F9795 1 RO T OR (16KW) 0F5539 1 RO T OR (13KW) 0F7549 1 RO T OR (10KW) 4[...]
-
Pagina 66
64 7KW 17 20 10 25 21 24 19 23 22 35 7 26 36 33 29 32 18 14 15 16 13 34 27 37 5 36 10 37 6 4 3 2 8 10 17 1 26 15 14 13 16 31 22 19 9 30 21 25 20 24 29 18 23 11 12 28 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 7 & 1 0kW , GN-41 0/GT -530 Regulator – Drawing No. 0F942 5[...]
-
Pagina 67
65 ITEM P ART NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA TOR HOUSING (7KW) 0F9285 1 CASTING, TWIN REGULA TOR HOUSING 2 0F5022 1 SOLENOID COIL, 12VDC 3 0C4647 1 GASKET , SOLENOID 4 0D4166 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0F8822 1 REGULA T OR BRACKET 6 022145 2 W ASHER FLA T 5/16-M8 7 022129 2 W ASHER LOCK 5/16-M8 8 0F4795 4 SCREW PP[...]
-
Pagina 68
66 16 13 34 5 11 6 7 17 26 14 15 3 9 7 35 4 6 33 3 2 12 27 32 30 28 8 1 31 8 10 27 18 19 22 23 29 21 25 24 20 Section 9 — Exploded Views and P ar ts Lists Air-cooled Generators 1 3 & 1 6kW, G T -990 Regulator – Drawing No. 0F9426[...]
-
Pagina 69
67 ITEM P ART NO . QTY . DESCRIPTION 1 0F9285 1 CASTING, TWIN REGULA T OR HOUSING 2 0F5022 1 SOLENOID COIL, 12VDC 3 0C4647 2 GASKET , SOLENOID 4 0D4166 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0F8096 1 BRKT REGULA T OR MOUNTING 990 6 022145 4 W ASHER FLA T 5/16-M8 7 022129 4 W ASHER LOCK 5/16-M8 8 0F4795 8 SCREW PPHM SEMS M4-0.7 X 10 9 045771 2 NUT HE[...]
-
Pagina 70
68 CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y ST A TEMENT Y OUR W ARR ANT Y R IGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and garden equipment engines must be de[...]
-
Pagina 71
69 EM IS SION CONTROL S YS TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty P eriod shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purch[...]
-
Pagina 72
Part No. 0F9421 Revision C (05/22/06) Printed in U.S.A. Section 1 0 – Warranty Air-cooled Generators GENERA C PO WER SYSTEMS "TW O YEAR" LIMITED W ARRANTY FOR GU ARDIAN ® "PREP A CKA GED EMERGENCY A UT OMA TIC ST ANDBY GENERA T ORS" F or a period of two years from the date of original sale, Generac P ower S ystems , Inc. (Gen[...]