Hearth and Home Technologies 4055-187 manuale d’uso
- Visualizza on-line o scarica il manuale
- 86 pagine
- 4.35 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Hearth and Home Technologies SILH50E
28 pagine 1.41 mb -
Indoor Fireplace
Hearth and Home Technologies SILH50EV
28 pagine 1.41 mb -
Indoor Fireplace
Hearth and Home Technologies QVI35S
44 pagine 2.11 mb -
Indoor Fireplace
Hearth and Home Technologies 8000CFLP-OAKIPI
62 pagine 3.5 mb -
Indoor Fireplace
Hearth and Home Technologies SILH30E-B
24 pagine 1.06 mb -
Indoor Fireplace
Hearth and Home Technologies Cinch Pipe & Termination Cap System
12 pagine 1.86 mb -
Indoor Fireplace
Hearth and Home Technologies QV32EV, QV32E
24 pagine 1.45 mb -
Indoor Fireplace
Hearth and Home Technologies SOHO
4 pagine 0.81 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies 4055-187. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies 4055-187 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies 4055-187 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies 4055-187 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies 4055-187
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies 4055-187
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies 4055-187
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies 4055-187 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies 4055-187 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies 4055-187, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies 4055-187, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies 4055-187. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immediately cal[...]
-
Pagina 2
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: __________________[...]
-
Pagina 3
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which,[...]
-
Pagina 4
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 4 = Contains updated information. 15 Appliance Setup A. Remove the Packaging 55 B. Remove Screen Package Assembly 55 C. Remove the Shipping Materials 55 D. Removing Fixed Glass Assembly 55 E. Clean the Appliance 55 F . Accessories 55 G. Place the Rockwool 56 H. Place the Lava Rock 56[...]
-
Pagina 5
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hea[...]
-
Pagina 6
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGW KURXJKDQ++7 DXWKRUL]HGGHDOHURUGLVWULEXWRU $ OLVWRI ++7DXWKRUL]HG[...]
-
Pagina 7
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and[...]
-
Pagina 8
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 8 H. Requirements for the Commonwealth of Massachusetts serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: • The equipment listed in [...]
-
Pagina 9
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 9 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE[...]
-
Pagina 10
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure 2.2 Clear Spa[...]
-
Pagina 11
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 1 1 I. Lighting Instructions (IPI) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when usin[...]
-
Pagina 12
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 12 J. Lighting Instructions (Standing Pilot) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • If your fi replace must be deactivated for service or an extended period of time, follow the instructions below . 1. Turn of f all electric p[...]
-
Pagina 13
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 13 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance off and allow it to completely cool. • Remove and clean fi xed glass assembly . See Section 3. • Replace the fi xed glass assembly and run continuously on[...]
-
Pagina 14
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cleaner[...]
-
Pagina 15
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 15 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequent construc- tion[...]
-
Pagina 16
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 16 (Either cobrahead or SIT) PRODUCT SPECIFIC Figure 3.1 IPI Flame Patterns Figure 3.2 Standing Pilot Flame Patterns[...]
-
Pagina 17
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual CEILING FIRESTOP ON FLOOR OF A TTIC (SECTION 8) VERTICAL TER[...]
-
Pagina 18
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 18 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MUST comply[...]
-
Pagina 19
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 19 In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Sections 3.C. and 3.D.) • V ent Clearances and Framing (Section 6) Rear vent One 45° elbow Horiz T erm Rear V ent T wo 90° elbows Horiz T erm Rear V ent One 90° [...]
-
Pagina 20
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 20 D Clearance to Ceiling 30 in. (762 mm) 0 in. 0 in. T O LEVEL OF ST ANDOFFS Combustible Object 36 in. (914 mm) 0 in. Combustible flooring may be installed next to the front of the appliance. Drywall 1/2 in. (13 mm) 1/2 in. (13 mm) C A B Model A Rough Opening (Wi dth) B Rough Opening (H[...]
-
Pagina 21
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 21 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular W all T op of Appliance Drywall A B D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles[...]
-
Pagina 22
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 22 Gas, Wood or Fuel Oil T ermination Cap B Gas T ermination Cap ** A * * If using dec orat ive cap cover(s), this dis tance may need to be increased. Refer t o the installation instruc tions supplied with the decorative cap c over. ** AB 6 in. (minim um) up to 20 in. 152 mm/508 mm 18 in[...]
-
Pagina 23
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 23 CAUTIO N: IF E X TERI OR WAL LS ARE FI NIS HED W ITH VI NY L SID ING , IT IS SUGG E STE D THA T A VIN YL PR O TECTOR K IT BE I NST ALL ED. D E B L C V V B F V B V V B X A J Fixed Closed M V K X RESTRICTION ZONE (TERMINA TION NOT ALLOWED) AIR SUPPL Y INLET X GAS METER V TERMINA TION CA[...]
-
Pagina 24
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP and SLP venting systems. Refer to Sec- tion 17.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from dif ferent manufacturers. The pipe is tested to be run insi[...]
-
Pagina 25
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 25 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally . • SUBTRACT 1-1/2 ft. from the tota[...]
-
Pagina 26
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 26 H 1 V 1 Figure 7.4 One Elbow 1. T op V ent - Horizontal T ermination - (continued) Figure 7.5 T wo Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horizontal measurement fo[...]
-
Pagina 27
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 27 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 min. V 1 +V 2 ma x. H 1 +H 2 max. 1 2 in. /3 05 mm 24 f t / 7 . 32 m (DVP) 19 ft /5 . 79 m 1 2 in. /30 5 mm 2 2 f t/ 6.7 1 m (SL P ) 19 ft /5 . 79 m[...]
-
Pagina 28
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 28 2. T op V ent - V ertical T ermination No Elbow Figure 7.7a 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.8 T wo Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.7b Remove Flue Visor Figure 7.7c 1[...]
-
Pagina 29
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 29 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed h[...]
-
Pagina 30
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 30 3. Rear V ent - Horizontal T ermination (DVP only) Figure 7.10 Figure 7.1 1 No Elbow One 45° Elbow 18 in. (457 mm) max. 18 in. (457 mm) max.[...]
-
Pagina 31
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 31 3. Rear V ent - Horizontal T ermination (DVP only) - (continued) T wo Elbows Figure 7.12 Figure 7.13 Three Elbows H 2 V 1 H 1 Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horiz[...]
-
Pagina 32
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 32 4. Rear V ent - V ertical T ermination (DVP only) One Elbow Figure 7.14 T wo Elbows Figure 7.15 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1[...]
-
Pagina 33
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 33 4. Rear V ent - V ertical T ermination (DVP only) - (continued) Three Elbows Figure 7.16 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of vertical, but can- not exceed 26 ft (7.92 m).[...]
-
Pagina 34
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 34 * When using SLP pipe, minimum clearances from the vent pipe to combus- tible materials at inside wall firestops are: T op: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). • DVP heat shield - designed [...]
-
Pagina 35
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP Pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP Pipe only - Frame an opening 9 in. by 9 in.[...]
-
Pagina 36
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 36 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 requires an at- tic shield constructed of 26 gauge minimum[...]
-
Pagina 37
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 37 CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ent 9 9 Appliance Preparation • Attach[...]
-
Pagina 38
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 38 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the vent cap has been removed it CANNOT be reattached. • Attach the fi rst vent section (it will snap into place). Slide the insulation gasket onto the vent se[...]
-
Pagina 39
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 39 C. Secure and Level the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make sure insulation an[...]
-
Pagina 40
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 40 A B A B 1 0 10 Inst alling V ent P ipe A. Assemble V ent Sections (DVP only) Attach V ent to the Firebox Assembly Note: The end of the pipe sect ions wi th th e lanced tabs will fac e toward the appliance. Attach the fi rst pipe section to the starting collar: • Lanced pipe end of [...]
-
Pagina 41
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 41 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance • Attach an DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe section onto the collar . • [...]
-
Pagina 42
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 42 Figure 10.8 Securing V ertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections D. Secure the V ent Sections • V ertical runs of DVP pipe must be supported every 8 ft. (2.44 m) after the 25 ft. (7.62 m) maximum unsupported rise. • V ertical runs of SLP pipe must be supp[...]
-
Pagina 43
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 43 Cut hole 1/8 in. (3 mm) greater in size than pattern of support box as it is projected onto roofline. 2 in. (51 mm) minimum below finished ceiling Cathedral ceiling support box Level F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on [...]
-
Pagina 44
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 44 Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.) - Minimum height from roof to lowest discharge opening. 24 in. min. (610 mm) Roof Pitch H (Min.) Ft. Roof Pitch H (Min.) Ft. Flat to 6/12 1.0* Over 1 1/12 to[...]
-
Pagina 45
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 45 I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap over the outer fl ue of the pipe section. • Secure the cap by driving three self-[...]
-
Pagina 46
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 46 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in. (38 mm) min. overlap SHEA THING V ent depth from back of appliance to outside surface of exterior wall (see chart below) Slip Section can be extended Inner V ent Outer V ent EXTERIOR Note: W h e n[...]
-
Pagina 47
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 47 1 1 11 Shrouds • Chase top shrouds may be fi eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as speci fi ed. Improper construction may overheat chase top. NOTICE: Some regional codes require an agency-Listed shroud. C[...]
-
Pagina 48
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 48 Min. Base Dim Min. Height Min. Base Dim Figure 1 1.2 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min. Opening Width Min. Base Dimension Minimum Height Figure 1 1.2 Roofed Style Shroud Dimensions Roofed Style Shroud (may be used with DVP-TV , DVP-TVHW [...]
-
Pagina 49
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 49 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician using Hearth & Home T echnologies specified and approved parts. B. Gas Pressure • Optimum appliance performance requires proper input [...]
-
Pagina 50
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 50 Red or Black Button Figure 13.1 Ignitor Button B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. • A 1 10 V AC junction box MUST be installed for use with a fan or remote control. See Figure 13.2 fo[...]
-
Pagina 51
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 51 GRN ORG BLK ORG Control Box To Junction Box Battery Pack 3V Adapter BLK BRN RED RED V alve WHT + - + - W all Switch WHT GRN* * GRN wire only used with optional wall switch WSK-ML T -HTL Ignitor Flame Sensor Pilot Assembly E. Electrical Service and Repair W ARNING! Risk of Shock! Label[...]
-
Pagina 52
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 52 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 13.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the appliance us[...]
-
Pagina 53
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 53 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular W all T op of Appliance Drywall A B Measured from top of hood (in inches) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 5 5-1/2 6-1/4 7 7-3/4 8-1/2 9[...]
-
Pagina 54
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 54 0 in. 0 in. 0 in. Finish wall material may be combustible - T op and Sides High T emperature Sealant (300° F/149° C min.) T op and Side Seal Joint B. Facing Material • Cover the metal front faces with non-combustible materi- als only . • Facing and/or fi nishing materials must [...]
-
Pagina 55
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 55 1 5 15 Appliance Setup A. Remove the Packaging Remove the shrink fi lm, corrugated top cap, bottom cap and column protectors from the appliance. The appliance should look as shown in Figure 15.1. B. Remove Screen Package Assembly • Grasp the top of the screen package and lift up to[...]
-
Pagina 56
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 56 G. Place the Rockwool W ARNING! Risk of Explosion! Follow rockwool place- ment instructions. DO NOT place rockwool directly over burner ports. Replace rockwool material annually . Improp- erly placed rockwool interferes with proper burner opera- tion. • Rockwool is shipped with this[...]
-
Pagina 57
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 57 N. Install Hood • Locate the four screws just inside the upper section of the appliance. • Slide the hood into position uncer the screw heads. • T ighten the four screws. See Figure 15.10. M. Unpackage the Hood & Floor Cover Remove parts package from appliance as shown in Fi[...]
-
Pagina 58
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 58 P . Close the Screen Assembly • Make sure the screen magnetic touch latches are in the open position. See Figure 15.12. • Hange the screen on the shoulder screws in the columns. See Figure 15.13. Open Figure 15.12 Magnetic T ouch Latch Open Hang Screen on Shoulder Screws Figure 15[...]
-
Pagina 59
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 59 A. Standing Pilot Ignition System 1 6 16 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed technician in the diagnos[...]
-
Pagina 60
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 60 T roubleshooting (continued) Sym ptom Possib le Caus e Cor rec tive Ac tion 3. (Co ntinued) C. Failed valve. T urn th e valve knob to the O N positi on. Place th e ON/OFF sw itch in the O N positi on. Check t he millivolt mete r a the ther mopil e term inals. The millivo lt meter shou[...]
-
Pagina 61
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 61 B. Intelli fi re Ignition System Sym ptom Possib le Caus e Cor rec tive Ac tion 1 . Pilot won’t light . The ignitor /module ma kes noise, but no spark. A . Inc orre ct wir ing. V eri fy “ S” wir e ( w hite ) for se nsor and “I ” wire (orange ) for ig nitor are co nnected to[...]
-
Pagina 62
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 62 Intelli fi re Ignition System - (continued) Sym ptom Possib le Caus e Cor rec tive Ac tion 4. Pi lot lights but c ontinue s to spar k, and main burn er will not i gnite. (If the pilot co ntinues to spar k afte r the pi lot fl ame has bee n lit, fl ame r ecti fi cat ion has not occ[...]
-
Pagina 63
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 63 1 7 17 Reference Materials Electrical Access Alternative Gas Access 1-3/4 in. (44 mm) 34-1/2 in. (876 mm) 1-1/2 in. (38 mm) 15-3/4 in. (400 mm) 8 in. (203 mm) 2-3/8 in. (60 mm) 31-1/2 in. (800 mm) 34 in. (864 mm) A B 23-1/2 in. (597 mm) 6-1/2 in. (165 mm) C 19-1/8 in. (486 mm) 1 1-5/8[...]
-
Pagina 64
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 64 B. V ent Components Diagrams Figure 17.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pipe inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 12 19 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in. (267 mm)[...]
-
Pagina 65
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 65 B. V ent Components Diagrams ( continued ) Figure 17.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK T rap Cap Brick Extension 13-3[...]
-
Pagina 66
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 66 B. V ent Components Diagrams ( continued ) Figure 17.4 DVP V ent Components DVP-TB1 Basement V ent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7 - 3/8 i n. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV V ertical T ermination Cap 1 in. (25 mm) 14 i[...]
-
Pagina 67
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 67 B. V ent Components Diagrams ( continued ) Figure 17.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a min[...]
-
Pagina 68
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 68 B. V ent Components Diagrams (continued) Figure 17.6 DVP V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm DVP-HRC-ZC-SS (Not a[...]
-
Pagina 69
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 69 Figure 17.7 SLP Series V ent Components B. V ent Components Diagrams (continued) Effec tive Height /Length Pip e inches mm SLP 4 4 10 2 SLP6 6 1 52 SLP 12 1 2 305 SLP2 4 24 61 0 SLP36 36 91 4 SLP 48 48 1 21 9 SLP 6A 2 - 6 5 1 - 152 SLP12A 2 - 12 51 - 305 8-3/4 in. 222 mm 6-1/2 in. 165[...]
-
Pagina 70
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 70 B. V ent Components Diagrams (continued) Figure 17.8 SLP Series V ent Components 1 in. (25 mm) 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-1/4 in. (184 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 13 in. 330 mm 13 in. 330 mm 1-5/16 in. 34 mm 10-9/16 in. 269 mm 14 in. 356 mm 12-1/2 in. [...]
-
Pagina 71
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 71 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) SLP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm SLP-HRC-ZC-SS (Not approved for NDV4842) (Not approved for NDV4842) B. V ent Components Diagra[...]
-
Pagina 72
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 72 Part number list on following page. Log Set Assembly 3 1 4 2 30 in. Novus Circulating - DV 13 11 12 9 17 18 24 23 25 28 27 26 20 21 19 10 22 5 6 7 8 16 14 15 ND V3630, ND V3630i C. Service Parts Beginning Manufacturing Date: Feb 2008 Ending Manufacturing Date: Active[...]
-
Pagina 73
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 73 C. Service Parts (continued) I M P O R TA N T : T H I S I S DAT E D I N FO R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered from [...]
-
Pagina 74
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 74 C. Service Parts (continued) NDV39 33, NDV 3933i Part number list on following page. Log Set Assembly 33 in. Novus Circulating - DV 3 1 4 2 13 11 12 9 17 18 24 23 25 28 27 26 20 21 19 10 22 5 6 7 8 16 14 15 Beginning Manufacturing Date: Feb 2008 Ending Manufacturing Date: Active[...]
-
Pagina 75
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 75 C. Service Parts (continued) NDV39 33, NDV 3933i I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manua[...]
-
Pagina 76
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 76 C. Service Parts (continued) NDV 4236, ND V 4236i Part number list on following page. Log Set Assembly 33 in. Novus Circulating - DV 3 1 4 2 13 11 12 9 17 18 24 23 25 28 27 26 20 21 19 10 22 5 6 7 8 16 14 15 Beginning Manufacturing Date: Feb 2008 Ending Manufacturing Date: Active[...]
-
Pagina 77
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 77 C. Service Parts (continued) I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered fro[...]
-
Pagina 78
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 78 C. Service Parts (continued) ND V 4842, N D V 4842i 13 11 12 10 9 17 18 21 22 20 19 28 27 26 25 24 23 5 6 7 8 16 14 15 Part number list on following page. Log Set Assembly 3 1 4 2 42 in. Novus Circulating Fireplace - DV Beginning Manufacturing Date: Feb 2008 Ending Manufacturing Date:[...]
-
Pagina 79
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 79 C. Service Parts (continued) I M P O R TA N T : T H I S I S D A T E D I N F O R M A T I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered f[...]
-
Pagina 80
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 80 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered from an autho rized dealer . Sto[...]
-
Pagina 81
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 81 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered from an autho rized dealer . Sto[...]
-
Pagina 82
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 82 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number . All par ts listed in this manual may be ordered from an autho rized dealer . Sto[...]
-
Pagina 83
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 83 D. Optional Components Model # Descri ption NDV3 63 0 T op /rear dir ect vent s tand ing pil ot, natu ral gas , 36 ” fra ming wi dth, 30 ” view ing glas s NDV3 63 0L T o p/rea r direc t vent sta nding pi lot, L .P . g as, 36 ” fra ming wi dth, 30 ” view ing glas s NDV3 63 0I T[...]
-
Pagina 84
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 84 D. Optional Components (continued) Model # Descri ption NDV4236 T o p/rear d irec t vent sta nding p ilot, n atura l gas, 42 ” fra ming wi dth, 36 ” view ing glas s NDV4236 L T op /rear dir ect vent s tand ing pil ot, L. P . gas, 42 ” fra ming wi dth, 36 ” view ing glas s NDV4[...]
-
Pagina 85
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 85 A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud 20 in. [508 mm] 17 in. [432 mm] 9-3/8 in. [238 mm] TCG375 T erra Cotta Cap LDSCP-M Shroud Leg Multipack (not shown) See your Heatilator dealer for a complete listing of optional components. D. Optional Components[...]
-
Pagina 86
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 86 E. Contact Information - NOTES - ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ _________[...]