Hearth and Home Technologies 6000GCF-IPI manuale d’uso
- Visualizza on-line o scarica il manuale
- 61 pagine
- 3.3 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Hearth and Home Technologies ST-36TRB-IPI
86 pagine 5.84 mb -
Indoor Fireplace
Hearth and Home Technologies GO35-IPI-NG
27 pagine 9.54 mb -
Indoor Fireplace
Hearth and Home Technologies SLR (Cosmo)
68 pagine 3.05 mb -
Indoor Fireplace
Hearth and Home Technologies GO30SP-NG or LP
27 pagine 9.54 mb -
Indoor Fireplace
Hearth and Home Technologies RBV4236IT
48 pagine 4.96 mb -
Indoor Fireplace
Hearth and Home Technologies NDV3630I
84 pagine 8.92 mb -
Indoor Fireplace
Hearth and Home Technologies 6000TRS-CE
42 pagine 1.72 mb -
Indoor Fireplace
Hearth and Home Technologies SL-550TRS-E
92 pagine 7.45 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies 6000GCF-IPI. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies 6000GCF-IPI o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies 6000GCF-IPI descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies 6000GCF-IPI dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies 6000GCF-IPI
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies 6000GCF-IPI
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies 6000GCF-IPI
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies 6000GCF-IPI non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies 6000GCF-IPI e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies 6000GCF-IPI, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies 6000GCF-IPI, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies 6000GCF-IPI. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. [...]
-
Pagina 2
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: _[...]
-
Pagina 3
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous[...]
-
Pagina 4
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 4 = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 45 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 14 Appliance Setup A. Remove Fixed Glass Assembly . [...]
-
Pagina 5
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 5 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT deale[...]
-
Pagina 6
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 6 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating mate[...]
-
Pagina 7
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass ha[...]
-
Pagina 8
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth [...]
-
Pagina 9
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NO[...]
-
Pagina 10
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Fig[...]
-
Pagina 11
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This applian[...]
-
Pagina 12
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.I. • Clean fi xed glass assembly . See Section 3.[...]
-
Pagina 13
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid[...]
-
Pagina 14
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subseque[...]
-
Pagina 15
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns[...]
-
Pagina 16
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System Note: Dual venti[...]
-
Pagina 17
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Insta[...]
-
Pagina 18
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and f[...]
-
Pagina 19
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 19 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield ?[...]
-
Pagina 20
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board,[...]
-
Pagina 21
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 21 Figure 6.3 Leveled T ermination Caps A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12[...]
-
Pagina 22
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 22 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to[...]
-
Pagina 23
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested to be r[...]
-
Pagina 24
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 24 V 1 Minimum H 1 + H 2 Maximum 1 ft. 305 mm Cannot do 1 1/2 ft. 457 mm 1-1/2 ft. 457 mm 2 ft. 610 mm 3 ft. 914 mm 3 ft. 914 mm 6 ft. 1.8 m 4 ft. 1.2 m 9 ft. 2.7 m V 1 + H 1 + H 2 = 50 ft. (15.2 m) Maximum H 1 + H 2 = 17 ft. (5.2 m) Maximum V 1 = 1 ft. (305 mm) Minimum [...]
-
Pagina 25
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 25 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum 6 in. 152 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 1-1/2 ft 457 mm 6 ft 1.8 m 1 ft 305 mm 3 ft [...]
-
Pagina 26
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 26 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/termination of f the top of the appliance, the fl ue restrictor should be used. V 1 V 1 = 50 ft. Max. (15.2 m) V 1 = 3 ft. Min. (914 mm) Installing the fl ue restrictor Figur[...]
-
Pagina 27
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 27 Figure 7.1 1 T wo Elbows H 1 V 1 V 2 Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 T op V ent - V ertical T ermination - (continued) Figure 7.12 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum 6 in. 152 mm 3 ft 914 mm * * * 1 ft 305 mm 3 ft 914 mm * * * 2 ft 607 mm 6 f[...]
-
Pagina 28
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 28 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep insulation or othe[...]
-
Pagina 29
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 29 A 12 in. 10 in. B Figure 8.6 W all Penetration B. W all Penetration Framing A* B 49-1/2 in, 48-1/2 in, Figure 8.5 Horizontal V enting Clearances to Combustible Materials 3 IN. TOP CLEARANCE HEA T SHIELD HEA T SHIELD WA LL WA LL SHIELD FIRESTOP 1 IN. CLEARANCE BOTTOM S[...]
-
Pagina 30
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 30 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.7). • Frame the area with the same s[...]
-
Pagina 31
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 31 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield cons[...]
-
Pagina 32
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 32 A. Attaching Sheetrock Ledges Attach sheetrock ledges together using the attachment holes (see Figure 9.1). Figure 9.1 The sheetrock ledges will attach to the top of the unit (see Figure 9.2). Figure 9.2 Attach previous assembly to the top of the unit using the provid[...]
-
Pagina 33
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 33 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. M[...]
-
Pagina 34
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 34 1 0 10 Inst alli ng V ent Pipe A. Assemble V ent Sections Attach V ent to the Firebox Assembly Note: The end of th e pipe secti ons with the lanc ed tabs will f ace toward the applianc e. Attach the fi rst pipe section to the starting collar: • Lanced pipe end to t[...]
-
Pagina 35
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 35 B. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl ue of the slip section over the outer fl ue of the pipe section. See Figure 10.6. • Slide together to the desired length. Figure 10.[...]
-
Pagina 36
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 36 D. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separate the pieces of pipe. Figure 10.1 1 Align and Disassemble V ent Sections Figure 10.10 Rota[...]
-
Pagina 37
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 37 E. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending[...]
-
Pagina 38
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 38 G. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H.) Pipe must be supported within 12 inches of the roofline using plumbers strapping or an SLP-FS when using the RF4-8 Flashing. Refer to Section 10.D. Secur[...]
-
Pagina 39
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 39 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP H. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar [...]
-
Pagina 40
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 40 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WALL (SEE CHART BELOW) SLIP SECTION CAN[...]
-
Pagina 41
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 41 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performan[...]
-
Pagina 42
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 42 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appl[...]
-
Pagina 43
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 43 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Figure 12.2 Intelli fi re Pilot Ignition (I[...]
-
Pagina 44
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 44 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box t[...]
-
Pagina 45
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 45 A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.e., steel studs, concrete board, etc.) Failure to comp[...]
-
Pagina 46
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 46 A. Remove Fixed Glass Assembly See Section 14.I. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the con[...]
-
Pagina 47
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 47 G. Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation. Ember material is shipped [...]
-
Pagina 48
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 48 H. Install the Log Assembly STEP 2. Place the metal grate on top of the burner . Position the legs of the grate into the forward set of indentations in the burner top. Make sure the grate is all the way forward. See Figure 14.9. Log Assembly: LOGS-6000G STEP 1. CAUTIO[...]
-
Pagina 49
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 49 Figure 14.19 T op View Figure 14.13 T op View STEP 5. Log #3 (SRV2103-1 10): Place log #3 on top of the burner surface in front of the hump. The bottom of the log has a square groove cut through it. The groove sits over the second grate tine from the left. Slide it ba[...]
-
Pagina 50
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 50 M. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.21. • L[...]
-
Pagina 51
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 51 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a p[...]
-
Pagina 52
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 52 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occ[...]
-
Pagina 53
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 53 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A B C D E F G I J K L M N P Q GAS LINE ACCESS ELEC[...]
-
Pagina 54
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 54 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) [...]
-
Pagina 55
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 55 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4[...]
-
Pagina 56
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 56 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components DVP-TB1 Basement Vent Cap 12 in. 1-1/2 in. 7-3/8 in. 14 in. 17-3/4 in. 10-1/2 in. 3-7/8 in. DVP-TV V ertical Termination Cap 13-1/4 in. 24-5/8 in. 27-1/2 in. RF6M Roof Flashing Multi-pak 31 in. 2[...]
-
Pagina 57
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 57 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. [...]
-
Pagina 58
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 58 C. Service Parts Part number list on following page. Service Parts Diagram 6000GCF-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ 11 6 8 9 12 10 7 1 2 3 4 5 Log Set Assembly[...]
-
Pagina 59
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 59 C. Service Parts List 6000GCF-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stock[...]
-
Pagina 60
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 60 Intermittent Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List 6000GCF-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts fo[...]
-
Pagina 61
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 61 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer[...]