Hearth and Home Technologies be-36-c manuale d’uso
- Visualizza on-line o scarica il manuale
- 65 pagine
- 6.07 mb
Vai alla pagina of
Manuali d’uso simili
-
Range
Hearth and Home Technologies VRT-GR-B-CE
44 pagine 2.23 mb -
Range
Hearth and Home Technologies VRT-GY-B-CE
44 pagine 2.23 mb -
Range
Hearth and Home Technologies GNBC33
28 pagine 1.64 mb -
Range
Hearth and Home Technologies be-36-c
65 pagine 6.07 mb -
Range
Hearth and Home Technologies VRTIKL-CE
44 pagine 2.23 mb -
Range
Hearth and Home Technologies VRT-BZ-P-CE
44 pagine 2.23 mb -
Range
Hearth and Home Technologies VRT-GR-P-CE
44 pagine 2.23 mb -
Range
Hearth and Home Technologies VRT-GY-N-CE
44 pagine 2.23 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies be-36-c. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies be-36-c o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies be-36-c descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies be-36-c dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies be-36-c
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies be-36-c
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies be-36-c
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies be-36-c non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies be-36-c e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies be-36-c, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies be-36-c, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies be-36-c. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
1 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Models: BE-36-C BE-36-CIPI Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - D[...]
-
Pagina 2
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership pu[...]
-
Pagina 3
3 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 - T able of Contents - Section 1: Listing and Code Approvals A. Appliance Certi fi cation ................................... 4 B. Glass Speci fi cations ...................................... 4 C. BTU Speci fi cations ........................................ 4 D.[...]
-
Pagina 4
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 4 Listing and Code Approvals C. BTU Speci fi cations 1 MODELS: BE-36-C, BE-36-CIPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.88-2002 • CSA2.33-M02 • UL307B A. Appliance Certi fi cation B. Glass Spec[...]
-
Pagina 5
5 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 G. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealt[...]
-
Pagina 6
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 6 A. Design and Installation Considerations Hearth & Home T echnologies direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source [...]
-
Pagina 7
7 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 I B G H C A D E F In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Section 3.C and 3.D) • V ent Clearances and Framing (Section 6). 3 Framing and Clearances NOTE: • Illustrations re fl ect typ[...]
-
Pagina 8
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 8 Figure 3.2 Clearances to Combustibles C B D A E H I F FROM TOP OF HOOD TO CEILING G J B. Constructing the Appliance Chase A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. V ertical vents that run on the outside of a b[...]
-
Pagina 9
9 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 D. Mantel Projections 1 ” 2 ” Note: Clearance from opening to perpendicular wall. Figure 3.3 Clearances to Mantels or other Combustibles above Appliance Figure 3.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.)[...]
-
Pagina 10
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 10 A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fi[...]
-
Pagina 11
11 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches ............... clearances above grade, ver anda, porch, deck or balcony B = 12 inches ............... clearances to window or[...]
-
Pagina 12
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 12 5 V ent Information and Diagrams Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside. • Use separate vent system for[...]
-
Pagina 13
13 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 3i n .C L E A R A N C E TERMINA T ION CAP FL EX -V ENT 1i n . CLEAR AN CE D. Use of Flex V ent The fl ex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than ½ inch sag between supports. A support is required at[...]
-
Pagina 14
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 14 E. V ent Diagrams Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • AL W A YS maintain speci fi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as speci fi [...]
-
Pagina 15
15 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Figure 5.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 V 2 H 1 V 1 NOTE: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). Note: Use SL D- Series componen[...]
-
Pagina 16
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 16 Figure 5.7 NOTE: For vertical venting over 20 feet an extended vertical baf fl e is recommended for improved fl ame appearance. CAP V 1 V 1 = 44 ft. Max. (13.4 m) T op V ent - V ertical T ermination No Elbows Baf fl e Instruction 1. Install the baf fl e over the[...]
-
Pagina 17
17 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Figure 5.10 2. T op V ent - V ertical T ermination - (continued) Three Elbows H 2 V 2 H 1 V 1 Figure 5.9 T wo Elbows V 2 H 1 V 1 NOTE: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.[...]
-
Pagina 18
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 18 Note: Use DVP Series components only . Note: Use DVP Series components only . Figure 5.12 Figure 5.1 1 H 1 = 28 in. (71 1 mm) Maximum 3. Rear V ent - Horizontal T ermination No Elbows H 1 = 9 in. (229 mm) Maximum Rear V ent - Horizontal T ermination One 45º Elbow[...]
-
Pagina 19
19 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Note: Use DVP Series components only . Note: Use DVP Series components only . Figure 5.13 INST ALLED HORIZONT ALL Y Figure 5.14 3. Rear V ent - Horizontal T ermination - (continued) T wo elbows V Minimum H 1 Maximum H 1 + H 2 Maximum 0 ft. 0 mm 1-1/2 ft. 457 mm 2-1/[...]
-
Pagina 20
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 20 Note: Use DVP Series components only . Figure 5.15 Figure 5.16 V 1 H 1 V 1 H 2 H 1 INS T ALLED HORIZONT ALL Y Note: Use DVP Series components only . 3. Rear V ent - Horizontal T ermination - (continued) One elbow V Minimum H 1 Maximum 1 ft. 305 mm 3-1/2 ft. 1.1 m 2 [...]
-
Pagina 21
21 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Note: Use DVP Series components only . H 1 V 1 H 2 V 2 Figure 5.17 3. Rear V ent - Horizontal T ermination - (continued) Three elbows V Minimum H 1 Maximum H 1 + H 2 + H 3 Maximum 0 ft. 0 mm 1-1/2 ft. 457 mm 2-1/2 ft. 762 mm 1 ft. 305 mm 3-1/2 ft. 1.1 m 6-1/2 ft. 2 [...]
-
Pagina 22
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 22 Combustible W all Penetration Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.2) whenever a wall is penetrated. Use same size framing materials as those used in the wall construction. The wall shield fi restop maintains minimum [...]
-
Pagina 23
23 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 C. V ertical Penetration Framing Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system pene- trates a ceiling/ fl oor (see Figure 6.4). • Frame the area with the same sized lumber as used in ceiling/ fl oor joist. ?[...]
-
Pagina 24
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 24 A. Choosing the T op or Rear V ent Appliance Preparation 7 Figure 7.2 Cut the seal cap strap across the rectangles next to the disk. The top heat shield may need to be removed to perform this step. Figure 7.3 Remove the white gasket material covering the seal cap. F[...]
-
Pagina 25
25 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Figure 7.7 T o attach the fi rst section of vent pipe, make sure to use the fi berglass gasket in the manual bag to seal between the fi rst vent component and the outer fi replace wrap. Use 2 self tapping screws to secure the gasket to the outer wrap. Secure the[...]
-
Pagina 26
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 26 C. Securing and Leveling the Appliance The diagram shows how to properly position, level, and secure the appliance (see Figure 7.11). Nailing tabs are pro- vided to secure the appliance to the framing members. • Rear venting - refer to V ent Clearances and Framing[...]
-
Pagina 27
27 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 A. Assembly of V ent Sections (DVP Pipe ONL Y) Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 1-1/2 inches. • Use pilot holes for screws. • Screws must not exceed one inch long. • Pipe may separate if not[...]
-
Pagina 28
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 28 Assembling DVP-12A Slip Sections The outer fl ue of the slip section should slide over the outer fl ue of the pipe section and into (inner fl ue) the last pipe section (see Figure 8.6) . Slide together to the desired length, making sure that a 1-1/2 inch outer ?[...]
-
Pagina 29
29 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 B. Disassembly of V ent Sections (DVP Pipe ONL Y) Improper support may allow vent to sag or separate. Securing the V ent Sections V ertical Sections V ertical sections of pipe must be supported every 8 feet after the 25 foot maximum unsupported rise. The vent sup- p[...]
-
Pagina 30
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 30 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the appliance fl ue outlet by wall brackets. T o install support brackets for vertical runs: • Attach wall brackets to the vent pipe and secure the wall bracket to the framin[...]
-
Pagina 31
31 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 C. Installing Heat Shield and Horizontal T ermination Cap (DVP Pipe ONL Y) NOTE: Where required, an exterior wall fl ashing is available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat Shield Requirements for Horizonta[...]
-
Pagina 32
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 32 Installing W all Shield Firestops and Horizontal T ermination Cap (SL Series Pipe ONL Y) Do NOT connect a pipe section to a termination cap without using the telescoping fl ue section found on the termination cap. NOTE: Where required, an exterior wall fl ashing i[...]
-
Pagina 33
33 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 D. Installing Roof Flashing and V ertical T ermination Cap T o install roof fl ashing see Figure 8.16. For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 8.16) . Caulk the gap between the roof fl ashing and [...]
-
Pagina 34
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 34 Figure 8.19 Assembling the Storm Collar Figure 8.20 Assembling the Storm Collar Around the Pipe Connect both halves of the storm collar with two screws (see Figure 8.19). Wrap the storm collar around the exposed pipe section and align brackets. Insert a bolt (provid[...]
-
Pagina 35
35 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 NOTE: Have the gas supply line installed in accordance with local building codes, if any . If not, follow ANSI 223.1. Installation should be done by a quali fi ed installer approved and/or licensed as required by the locality . (In the Commonwealth of Massachusetts[...]
-
Pagina 36
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 36 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved without requir[...]
-
Pagina 37
37 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Electrical Information 10 NOTE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.1 . B. Connecti[...]
-
Pagina 38
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 38 D. Intelli fi re Ignition System W iring This appliance requires a 1 10 V AC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.3. This appliance is equipped with an Intelli fi re control valve which operates on a 3 volt sys[...]
-
Pagina 39
39 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 E. Junction Box Installation F . Wall Switch Installation for Fan (Optional) Figure 10.5 Junction Box Wired to W all Switch If the box is being wired to a wall mounted switch for use with a fan (See Figure 10.5): • The power supply for the appliance must be brough[...]
-
Pagina 40
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 40 A. Mantel Projections Figure 1 1.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance. Finishing B. Facing Material 11 Figure 1 1.3 Noncombustible[...]
-
Pagina 41
41 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Appliance Setup 12 A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity . C. Accessories Ins[...]
-
Pagina 42
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 42 Log Set Assembly: LOGS-BE-36-C D. Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. Models: BE-36-C Carefully remove the logs from [...]
-
Pagina 43
43 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Shutter Settings Figure 12.2 Glass Assembly E. Glass Assembly Removing Glass Assembly Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 12.2). Replacing Glass Assembly Replace the glass door o[...]
-
Pagina 44
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 44 Operating Instructions 13 CAUTION If installing Intelli fi re ignition battery backup: • Do not install batteries if the backup mode may not be used for extended time. • Batteries may leak. • Install batteries only when needed for power outage. Before operati[...]
-
Pagina 45
45 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 B. Lighting Appliance 1. Turn of f all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. 3. W ait fi ve (5) minutes to clear out any gas. Then smell[...]
-
Pagina 46
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 46 1. Turn of f all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close control access panel. 5. T[...]
-
Pagina 47
47 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 W ARNING C. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuou[...]
-
Pagina 48
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 48 A. Standing Pilot Ignition System T roubleshooting 14 With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service pe[...]
-
Pagina 49
49 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter shou[...]
-
Pagina 50
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 50 B. Intelli fi re Ignition System Sympton Possible Cause Corrective Action 1. The ignitor/module makes noise, but no spark. a. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals on modul[...]
-
Pagina 51
51 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3. (Continued) Pilot lights but continues to spark, and main burner will not ignite. (If the pilot contin- ues to spark after the pilot fl ame has been lit, fl ame recti fi cati[...]
-
Pagina 52
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 52 Maintaining and Servicing Appliance 15 Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance check-up at the beginning of each heating season. Annu[...]
-
Pagina 53
53 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions t[...]
-
Pagina 54
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 54 Reference Materials 16 A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions and clearances refer to Section 3. Figure 16.1 Appliance Dimensions A B C D E F G H I J K L M N O P Q R S T U V X W Ø G[...]
-
Pagina 55
55 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 B. V ent Components Diagrams Figure 16.2 DVP vent components 10 - 1/ 2 in. (267 mm) 10 - 7/ 8 i n . (276 mm) 45 ° 7- 3 / 8 i n . (187 m m ) 11- 3 / 8 i n . (289 mm) 1 -1/4 in. (32 mm) 9- 1/4 i n. (235 mm) 13 -1/ 4 i n . (337 mm) 1/2 in . T YP DVP90ST (90° Elbow) 1[...]
-
Pagina 56
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 56 B. V ent Components Diagrams (continued) Figure 16.3 DVP vent components DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length [...]
-
Pagina 57
57 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Tra p Ca p Bri[...]
-
Pagina 58
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 58 DVP-TB1 Basement V ent Ca p 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV V ertical T ermination Cap 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW V er tical[...]
-
Pagina 59
59 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 B. V ent Components Diagrams (continued) Pipe Length/Inches SL-06D 5-3/4 SL-09D 8-3/4 SL-12D 1 1-3/4 SL-12/17D 1 1-3/4 to 16-3/4 SL-17/24D 16-3/4 to 23-3/4 SL-24D 23-3/4 SL-36D 35-3/4 SL-48D 47-3/4 SL-FLEX-2 24 SL-FLEX-3 36 SL-FLEX-5 60 SL-FLEX-10 120 There must b e[...]
-
Pagina 60
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 60 4 5 6 7 8 9 10 11 12 C. Service Parts Part number list on following page. Log Set Assembly Service Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ BE-36-C 1 2 3 Î[...]
-
Pagina 61
61 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTION SERIAL # P ART NUMBER Log [...]
-
Pagina 62
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 62 IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is lo- cated on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTION SERIAL # P ART NUMBER 1 [...]
-
Pagina 63
63 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 V alve Assembly Parts List Service Parts BE-36-CIPI Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and m[...]
-
Pagina 64
Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 64 © 2005 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies D. Limited Lifetime W arranty BASIC ONE-YEAR W ARRANTY . HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington Boulevard, Lakeville, MN 55044, war- ran[...]
-
Pagina 65
65 Hearth & Home T echnologies • BE-36-C, BE-36-CIPI • 397-981 Rev . V 1/07 - NOTES - ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ _____________[...]