Hearth and Home Technologies EC36 manuale d’uso
- Visualizza on-line o scarica il manuale
- 32 pagine
- 1.11 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Hearth and Home Technologies 8000TR-OAK-IPI
70 pagine 3.98 mb -
Indoor Fireplace
Hearth and Home Technologies SL-750TV-IPI-D
53 pagine 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies SL-950TV-D
53 pagine 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies Cast Mantels
8 pagine 0.81 mb -
Indoor Fireplace
Hearth and Home Technologies Novus
4 pagine 1.06 mb -
Indoor Fireplace
Hearth and Home Technologies SP18NG
21 pagine 3.22 mb -
Indoor Fireplace
Hearth and Home Technologies RUTHERFORD-50
52 pagine 4.91 mb -
Indoor Fireplace
Hearth and Home Technologies CERONA-42
65 pagine 3.95 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies EC36. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies EC36 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies EC36 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies EC36 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies EC36
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies EC36
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies EC36
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies EC36 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies EC36 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies EC36, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies EC36, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies EC36. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
08/04 17339 Rev L 1 INST ALLA TION & OPERA TING INSTRUCTIONS EC36 EC39 EC42 WOODBURNING FIREPLACE WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified inst aller , service agency or the gas supplier [...]
-
Pagina 2
2 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS CAUTION: Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. W et insulation will produce an odor when the fireplace is used. T able of Content s Design and Installation Considerations ........................................................[...]
-
Pagina 3
08/04 17339 Rev L 3 EC SERIES INST ALLA TION INSTRUCTIONS DESIGN AND INST ALLA TION CONSIDERA TIONS When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly . This may result in smoke spilla[...]
-
Pagina 4
4 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! This fireplace and its component s are designed to be inst alled and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit- ers Laboratories listing and may void the product warra[...]
-
Pagina 5
08/04 17339 Rev L 5 EC SERIES INST ALLA TION INSTRUCTIONS C. SYSTEM COMPONENTS 1. Fireplace Component s HEARTH EXTENSION GLASS DOORS INTEGRAL GRA TE (supplied) GR4, GR5, GR6 JUNCTION BOX JK8 DM1036/DM1036B/DM1036S DM1039/DM1039B/DM1039S DM1042/DM1042B/DM1042S DP1036/DP1036B/DP1036S DP1042/DP1042B/DP1042S FAN KIT FK18 BC10 Fan Speed Control DMA1036B[...]
-
Pagina 6
6 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Fireplace Dimensions OUTSIDE AIR KIT AK14 Ca t . # A B C D E /E C 36 36 in. [914m m ] 41 in. [104 1m m ] 25- 1/4 in. [64 1m m ] 12- 5/8 in. [321 m m ] E /E C 39 39 in. [991m m ] 44 in. [111 8m m ] 28- 1/4 in. [71 8m m ] 14- 1/8 in. [359 m m ] E /E C 42 42 in. [1067 m m ] 47 in. [119 4m m ] 3[...]
-
Pagina 7
08/04 17339 Rev L 7 EC SERIES INST ALLA TION INSTRUCTIONS 2. Chimney Component s The following pictures show only those chimney components which may be safely used with this fireplace. Catal og # Descri pti on: CAK4 A Ch im n ey Air Kit ID 4 Ins u l a t e d D u c t / O u t s i d e A i r U D4 U n in su l at e d Du ct / O u t s ide Air SL3 06 Ch im n[...]
-
Pagina 8
8 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS SL3 - Chimney St abilizer SL330 - Offset/Return RF370 - Roof Flashing Flat to 6/12 Pitch RF371 - Roof Flashing 6/12 to 12/12 Pitch CB876 Chimney Bracket AS8 Straight Attic Insulation Shield Chimney Sections Firestop Sp acer JB877 Joint Band Ca t a log # A B SL 306 6 in . 4 - 3/4 i n. SL312 1[...]
-
Pagina 9
08/04 17339 Rev L 9 EC SERIES INST ALLA TION INSTRUCTIONS LDS33 (3 ft x 3 ft) LDS46 (4 ft x 6 ft) Decorative Shroud TR344 Round T ermination Cap TR342 Round T elescoping T ermination Cap ST375 Square T ermination Cap CT35 Chase T op CAK4A Chimney Air Kit TS345/TS345P Square T ermination Cap[...]
-
Pagina 10
10 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not draw out side air from garage spaces. Exhaust product s of gasoline engines are hazardous. Do not install out side air ducts such that the air may be drawn from attic sp aces, basement s or above the roofing where other heating appliances or fans and chimneys exhaust or uti[...]
-
Pagina 11
08/04 17339 Rev L 11 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not apply combustible finishing materials over any part of the black face of this fireplace or a structure fire may result. The black metal fireplace front may only be covered with noncombustible materials such as ce- ramic tile, brick, or stone. Do not cover or block any cooli[...]
-
Pagina 12
12 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 6 - Sidewalls and Surrounds 3. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum of 12 in. from the fireplace opening. See Figure 6. If you are using a decorative surround constructed of combustible material, it must be located within the shaded area defin[...]
-
Pagina 13
08/04 17339 Rev L 13 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not combine offsets to create an offset greater than 30 deg from verti- cal. This may create a fire hazard since the natural draft may be restricted. 1. Using Offset s and Returns a. T o bypass any overhead obstructions, the chimney may be offset using a 15-deg or 30-deg offset[...]
-
Pagina 14
14 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 8 - Chimney Height T able 2 3. Number of Sections Required T o determine the chimney components needed to complete your particular installation, follow the step s below: a. Determine the total vertical height of the fireplace installation. This dimension is measured from the base of [...]
-
Pagina 15
08/04 17339 Rev L 15 EC SERIES INST ALLA TION INSTRUCTIONS F . INST ALLA TION OF FIREPLACE W ARNING! Before st arting, do the following: 1. Wear gloves and safety glasses for protection. 2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure. 3. Always maintain the minimum air sp ace required to the enclos[...]
-
Pagina 16
16 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 1 1 Installing the Firestop S pacer CAUTION: Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area. Figure 10 Assembling Chimney Sections W ARNING! Carefully follow the instructions for assembly of the pipe and other p arts needed to inst all this firepla[...]
-
Pagina 17
08/04 17339 Rev L 17 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Maintain a minimum of 2 in. air clearance to all parts of the chimney system at all times! Fail- ure to maintain this 2 in. air clearance will cause a structure fire. CAUTION: Inner flue and outer liner sections cannot be dis- assembled once locked together . Plan ahead to ensure [...]
-
Pagina 18
18 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 14 - Ceiling/Attic Construction Figure 15 - Air Kit Handle Location 9. Mark the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney . Drive a nail up through the roof to mark the center . See Figure 14. 10 . Cut o[...]
-
Pagina 19
08/04 17339 Rev L 19 EC SERIES INST ALLA TION INSTRUCTIONS Note: Use only a noncombustible material to finish the face of the fireplace below the level of the front standof fs. A noncombustible material such as USG MICORE CV230 Mineral Fiber Board, or USG DUROCK Cement Board is recommended for this purpose. Figure 16 - Air Clearance Around Gas Line[...]
-
Pagina 20
20 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring on con- cealed combustible materials. Hearth sealing strips prevent burning or hot p articles from inadvertently falling directly on combustible surfaces in the event the building[...]
-
Pagina 21
08/04 17339 Rev L 21 EC SERIES INST ALLA TION INSTRUCTIONS Figure 19 - Position the Hearth Extension 18. Position the Hearth Extension Position and secure the hearth extension over the protective metal strips that have been placed p artially under the fireplace front. These strip s should be protruding approximately 2 in. from under the fireplace f[...]
-
Pagina 22
22 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS G . CONSTRUCTING A CHASE Figure 20 - Chase Constructions Figure 21 - Chase Assembly 1. Materials a. The chase is constructed using framing materials much the same as the walls in your home. A variety of materials may be used including brick, stone, veneer brick, or standard siding materials[...]
-
Pagina 23
08/04 17339 Rev L 23 EC SERIES INST ALLA TION INSTRUCTIONS Figure 22 - Installing a TR344 Round T ermination Cap Figure 23 - Inst alling a TR342 Round T elescoping T ermination Cap 2. Chase T op Construct a chase of desired materials maintaining a minimum 2 in. air space around the chimney . 3. T ermination Cap a. Install the chimney sections up th[...]
-
Pagina 24
24 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS W ARNING! Never inst all a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire. W ARNING! Detailed instructions for inst allation of the chase top, storm colla[...]
-
Pagina 25
08/04 17339 Rev L 25 EC SERIES INST ALLA TION INSTRUCTIONS Note: Save and p ass this instruction manual to subsequent home owners. The informa- tion provided is intended to notify and warn them about making unsafe future modifications such as the addition of shelves or the use of unauthorized part s and repairs. W ARNING! DO NOT operate this firepl[...]
-
Pagina 26
26 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 26 Proper Operating Positions of Bi-Fold Doors W ARNING! Burning wet, unseasoned wood can cause ex- cessive creosote accumulation. When ignited, it can cause a chimney fire that may result in a serious house fire. CAUTION: When left closed while burning your fireplace, firescreens an[...]
-
Pagina 27
08/04 17339 Rev L 27 EC SERIES INST ALLA TION INSTRUCTIONS CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq- uids to start or “freshen up” a fire in this fire- place. Keep all such liquids well away from the fireplace. Note: When first lighting your fireplace, it may be necessary to pre-w[...]
-
Pagina 28
28 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS Figure 27 - Flue Draf t Flue draft is measured as negative pressure in the chimney . The amount of negative pressure determines how strong the draft is. The draf t is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney . There are three ba[...]
-
Pagina 29
08/04 17339 Rev L 29 EC SERIES INST ALLA TION INSTRUCTIONS I. MAINTENANCE INSTRUCTIONS W ARNING! A chimney fire can permanently damage your chimney system. This damage can only be re- paired by replacing the damaged component part s. Chimney fires are not covered by the Lim- ited W arranty and Buyer Protection Plan. Figure 28 Chimney & T ermina[...]
-
Pagina 30
30 17339 Rev L 08/04 EC SERIES INST ALLA TION INSTRUCTIONS HOMEOWNER’S NOTES[...]
-
Pagina 31
08/04 17339 Rev L 31 EC SERIES INST ALLA TION INSTRUCTIONS INDEX A Air Clearance 17, 19 Air Kit 6, 18 Air Kit Handle Location 18 Ashes, Disposal of 29 Attic Insulation Shield 17 B Building Codes 4, 14, 18, 21 C Chase 22 Chase T op 9, 23 Chimney Assembling Sections Through the Roof 18 Checking the Assembly 17 Cleaning 29 Creosote 29 Exit Point Throu[...]
-
Pagina 32
32 17339 Rev L 08/04 HEA TILA TOR WOODBURNING FIREPLACE LIMITED WARRANTY As part of its 20-YEAR BUYER PROTECTION PROGRAM AS P ART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (“PROGRAM”), HEARTH & HOME TECHNOLOGIES INC. (“HHT”) is pleased to offer a Limited W arranty and a Replacement Parts Advantage covering specific components of your Heat[...]