Hearth and Home Technologies QVI-25FB-S manuale d’uso
- Visualizza on-line o scarica il manuale
- 40 pagine
- 2.4 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Hearth and Home Technologies CD4236MILR
76 pagine 8.38 mb -
Indoor Fireplace
Hearth and Home Technologies CF550E
24 pagine 1.58 mb -
Indoor Fireplace
Hearth and Home Technologies 7100FP-BK-B
72 pagine 3.33 mb -
Indoor Fireplace
Hearth and Home Technologies QV32EV, QV32E
24 pagine 1.45 mb -
Indoor Fireplace
Hearth and Home Technologies Paloma
4 pagine 0.43 mb -
Indoor Fireplace
Hearth and Home Technologies QV26E
25 pagine 2.15 mb -
Indoor Fireplace
Hearth and Home Technologies FB-GRAND-S
44 pagine 2.47 mb -
Indoor Fireplace
Hearth and Home Technologies CF750EV (208/240V)
24 pagine 1.58 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies QVI-25FB-S. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies QVI-25FB-S o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies QVI-25FB-S descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies QVI-25FB-S dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies QVI-25FB-S
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies QVI-25FB-S
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies QVI-25FB-S
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies QVI-25FB-S non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies QVI-25FB-S e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies QVI-25FB-S, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies QVI-25FB-S, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies QVI-25FB-S. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 1 Model: QVI-25FB-S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any phone in your building. - Imm[...]
-
Pagina 2
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased from: __________[...]
-
Pagina 3
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. High Altitude Installations . . . . . . . . . . . . . . . . . .[...]
-
Pagina 4
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions. Not e: This installation must c onform wi th local c odes. In the absenc e of local c odes y[...]
-
Pagina 5
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 5 Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes. Prior to installing the gas insert: • Have the chim[...]
-
Pagina 6
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 6 3 3 F ireplace Size Requirements Figure 3.1 Fireplace Opening NOTE: For actual appliance dimensions refer to Section 15. 20-3/8 in. 14-7/16 in. 29-3/4 in. 15 in. 5-9/16 in. 1-1/16 in. 18-15/16 in. GAS INLET (GAS BALL V AL VE NOT SHOWN) EXISTING MINIMUM WOODBURNING FIREPLACE SIZE Location In[...]
-
Pagina 7
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 7 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk. Odor Risk. • Clearance to combustible material under the insert is 1/4 inch (0.6 cm). • Use leveling [...]
-
Pagina 8
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.1 speci fi es minimum vent heights for various pitched roofs. Roof Pitch H (Min.) Ft. Flat [...]
-
Pagina 9
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed. Figure 5.1 C. Measuring Standards V ertical measurements listed in the vent diagram (Figure 5.1[...]
-
Pagina 10
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation. • Local building codes required by authority having jurisdiction. • NFPA 211 Prepare the[...]
-
Pagina 11
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 1 1 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert). • One length of 3-inch fl exible vent pipe for combustion air (included [...]
-
Pagina 12
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 12 Figure 7.1 ST AINLESS STEEL ADAPTER FOR EXHAUST (MUST BE INST ALLED) INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK-ZC-ADPB (For Flashing Class-A Pipe) TERMINA TION CAP (SQUARE FLASHING REMOVED) EXHAUST VENT PIPE SUPPLIED WITH TERMINA TION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) AL TE[...]
-
Pagina 13
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 13 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. C. Placing, Securing and Leveling the Appliance • [...]
-
Pagina 14
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 14 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.3. Roof Pitch H (Min.) Ft. Flat to 6/12.................... 1.0* Over 6/12 to 7/12 ........1.25* Over 7/12 t[...]
-
Pagina 15
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 15 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • Check all fi ttings and connections of appliance w[...]
-
Pagina 16
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 16 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved without requiring changes for elevatio[...]
-
Pagina 17
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 17 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.1. ON/OFF S[...]
-
Pagina 18
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 18 B. Junction Box Installation Figure 9.2 Junction box installation FEED PLUG THROUGH HOLE INSERT RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT JUNCTION BOX SIDE WALL Optional Accessories Connecting the electrical junction box is required if using a blower or remote. • Plug the cord [...]
-
Pagina 19
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 19 Figure 9.4 Fan Wiring Diagram JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110-120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BLK WHT GROUND WHT BLK BLK BLK REMOTE RECEPTACLE INSERT STUD THROUGH HOLE AND SECURE WITH WING NUT WING NUT TEMP SWITCH BRACKET FAN T[...]
-
Pagina 20
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 20 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. 1 0 10 Fin ishing Figure 10 .1 Clearances to Mantels or other Comb[...]
-
Pagina 21
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 21 Figure 1 1.1 Placement of Embers BURNER P AN EMBER PLACEMENT 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath i[...]
-
Pagina 22
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 22 E. Positioning the Logs Log Set Assembly: LOGS-2031 2031-700 4 5 6 1 3 2 FIREBOX LEDGE LOG PLACEMENT INSTRUCTIONS Log Placement CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 FIREBOX LEDGE FIREBOX FIREBOX LEDGE LOG #1 (SRV2032-701): Place log #1 on the fi [...]
-
Pagina 23
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 23 LOG #3 (SRV2032-703): Position log #3 by locating its slot over the tab on right front of the burner such that left end of log contacts log tab near the center of the burner . LOG #2 (SRV2032-702): Position log #2 by locating its slot over the tabs on left front of the burner . 2 2 3 3 LOG[...]
-
Pagina 24
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 24 Figure 1 1.2 Glass Assembly F . Glass Assembly Removing Glass Assembly There are two glass latches on the left side of glass as- sembly and two glass latches on the right side. • T o release glass assembly , pull latch forward and allow to retract away from glass assembly . • Remove gl[...]
-
Pagina 25
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 25 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition. Before operating this appliance have a qualified te[...]
-
Pagina 26
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 26 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close cont[...]
-
Pagina 27
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 27 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • Pilot fl ame should be as shown in Figure 12.1. D. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- d[...]
-
Pagina 28
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 28 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance. • Keep furniture, draperies away from appliance. Smok[...]
-
Pagina 29
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 29 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service person in the diagnosi[...]
-
Pagina 30
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 30 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter should read greater than 125[...]
-
Pagina 31
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 31 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season. Annual inspection by qua[...]
-
Pagina 32
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 32 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions to air fl ow through the[...]
-
Pagina 33
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 33 Figure 15.1 Appliance Dimensions A 14-7/16 in. 377 mm C E 5-9/16 in. 1-1/16 in. G GAS INLET (GAS BALL V AL VE NOT SHOWN) H F D 3-5/8 in. REF 92 mm 3-7/16 in. 87 mm 1-1/16 in. 27 mm T wo 2-13/16 in. 71 mm B 4-3/8 in. 111 mm 1-9/16 in. 40 mm 1 5 15 Reference Materials A. Appliance Dimension [...]
-
Pagina 34
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter . LINK-DV4-30B or (LINK-DV4-30): Masonry 3 inch fl ex liner kit. [...]
-
Pagina 35
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 35 Service Parts Diagram QVI-25FB-S R Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ C. Service Parts List Part number list on following page. Log Set Assembly 4 2 1 3 5 6 7 8 9 10 11 12 13 14 15 16[...]
-
Pagina 36
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 36 QVI-25FB-S Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION CO[...]
-
Pagina 37
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 37 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P ART NUMBER 1 Pil[...]
-
Pagina 38
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 38 D. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in th[...]
-
Pagina 39
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 39 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or co[...]
-
Pagina 40
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 40 Quadra-Fire, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .quadra fi re.com E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer , please vis[...]