Hearth and Home Technologies SL-350TRS-D manuale d’uso
- Visualizza on-line o scarica il manuale
- 85 pagine
- 7.52 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Hearth and Home Technologies NDV3933
84 pagine 8.92 mb -
Indoor Fireplace
Hearth and Home Technologies CASTILE-GAS-CWL
56 pagine 3.22 mb -
Indoor Fireplace
Hearth and Home Technologies Supreme-XTS
45 pagine 2.53 mb -
Indoor Fireplace
Hearth and Home Technologies SL-750TRS-IPI-E
85 pagine 7.52 mb -
Indoor Fireplace
Hearth and Home Technologies 6000G
74 pagine 3.6 mb -
Indoor Fireplace
Hearth and Home Technologies 6000GL-IPILP-S
70 pagine 3.38 mb -
Indoor Fireplace
Hearth and Home Technologies 4 14-1/8
2 pagine 0.4 mb -
Indoor Fireplace
Hearth and Home Technologies Grand-XTS
45 pagine 2.53 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies SL-350TRS-D. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies SL-350TRS-D o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies SL-350TRS-D descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies SL-350TRS-D dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies SL-350TRS-D
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies SL-350TRS-D
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies SL-350TRS-D
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies SL-350TRS-D non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies SL-350TRS-D e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies SL-350TRS-D, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies SL-350TRS-D, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies SL-350TRS-D. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 1 Models: SL-750TRS-IPI-E SL-550TRS-IPI-E SL-350TRS-D SL-350TRS-IPI Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. •[...]
-
Pagina 2
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: _____[...]
-
Pagina 3
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 3 Î = Contains updated information. T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Speci fi cations . . . . . . . . . . . . . . . . . . . . [...]
-
Pagina 4
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 4 MODELS: SL-750TRS-IPI-E,SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.88a-2007 • CSA 2.33a-2007 Models U.S. (0-2000 ft.) or Canada [...]
-
Pagina 5
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 5 G. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned o[...]
-
Pagina 6
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 6 A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side. No additional outsi[...]
-
Pagina 7
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 7 K C A L F I B G E D J J G A F C A H M N In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Section 3.C and 3.D) • V ent Clearances and Framing (Section 6). 3 3 F raming[...]
-
Pagina 8
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 8 Figure 3.2 Clearances to Combustibles C B D A Models AB C D E F G H I J DVP PIPE SL PIPE Rough Opening (Height) * DVP PIPE SL PIPE Rough Opening (Width) Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of[...]
-
Pagina 9
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 9 D. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify ef fects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a give[...]
-
Pagina 10
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 10 E. Mantel Projections 5 6 7 8 9 10 3 4 5 12 11 10 9 8 7 6 TOP OF HOOD OR FIREPLACE OPENING 4 12 13 11 32 CEILING All measurements are in inches. Figure 3.3 Clearances to mantels or other combustibles above appliance 1/2 in. SHEETROCK 3-1[...]
-
Pagina 11
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 1 1 A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials awa[...]
-
Pagina 12
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 12 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches..........[...]
-
Pagina 13
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 13 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside. • Use separate vent system for thi[...]
-
Pagina 14
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 14 3i n .C L E A R A N C E TERMINA TION CAP FL EX -V ENT 1i n . CLEAR AN CE D. Use of Flex V ent The fl ex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than ½ inch sag between suppor[...]
-
Pagina 15
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 15 Figure 5.4 E. V ent Diagrams 1. T op V ent - Horizontal T ermination V enting V Minimum H 1 Maximum SL-350TRS-D SL-550, SL-750TRS-E 90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm 1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm 1-1/2 ft. 457 mm 3 ft. [...]
-
Pagina 16
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 16 H 1 H 2 V 1 Figure 5.5 T wo Elbows V Minimum H Maximum SL-350TRS-D, SL-550TRS-E, SL-750TRS-E 90º Elbow NOT ALLOWED 1/2 ft. 152 mm 1 ft. 305 mm 1-1/2 ft. 457 mm 2 ft. 610 mm 2-1/2 ft. 762 mm 4 ft. 1.2 m 3-1/2 ft. 1.1 m 6 ft 1.8 m 4-1/2 f[...]
-
Pagina 17
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 17 Figure 5.6 1. Top Vent - Horizontal Termination - ( continued ) Three Elbows H 1 H 2 V 1 V 2 V 1 Minimum H 1 Maximum H 1 + H 2 Maximum H 1 Maximum H 1 + H 2 Maximum Model: SL-350TRS-D Models: SL-550TRS-IPI-E, SL-750TRS-IPI-E Elbow only 1[...]
-
Pagina 18
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 18 2. T op V ent - V ertical T ermination No Elbow V 1 = 44 ft. Max. (13.4 m) Note : Use SL-D Series components only . Figure 5.8 INNER HEA T SHIELD T op V ent Application Rear V ent Application Note : Be sure to re- install the inner heat [...]
-
Pagina 19
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 19 Figure 5.8 T wo 90º Elbows H 1 V 1 V 2 V 1 Minimum H 1 Maximum H 1 Maximum V 2 V 1 + V 2 Minimum SL-350TRS-D SL-550TRS-E, SL-750TRS-E * * 90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm * * 1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm * * 1 ft. 30[...]
-
Pagina 20
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 20 Figure 5.9 2. T op V ent - V ertical T ermination - ( continued ) Three 90º Elbows H 1 H 2 V 1 V 2 ALL MODELS V 1 H 1 + H 2 Maximum V 2 V 1 + V 2 Minimum 90º Elbow 0 0 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 1/2 ft.. 152 mm 1 ft. 305 mm * * [...]
-
Pagina 21
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 21 V 1 H 1 V 3 V 2 H 2 2. T op V ent - V ertical T ermination - ( continued ) Four 90º Elbows Figure 5.17 V 1 Min. H 1 Max. V 2 Min. H 2 Max. V 3 Min. 1-1/2 ft. 457 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m 3-1/2 ft. 1.0 m V 1 + V 2 + V 3 + H[...]
-
Pagina 22
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 22 Figure 5.12 T wo 90º Elbows 3. Rear V ent - Horizontal T ermination Figure 5.10 No Elbow H 1 = 24 in. (610 mm) Maximum 90-DEGREE ELBOWS H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/[...]
-
Pagina 23
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 23 3. Rear V ent - Horizontal T ermination - ( continued ) Figure 5.13 Figure 5.14 Three Elbows H 1 Maximum V 1 Minimum H 2 + H 3 H 1 + H 2 + H 3 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm 3-1/2 ft. 1.1 m 1 f[...]
-
Pagina 24
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 24 Figure 5.15 T wo Elbows H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm 3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m 5-1/2 ft. 1.2 m 2 ft. 610 mm 5 ft. 1.5 m 1[...]
-
Pagina 25
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 25 A* B* C D SL-750TRS-IPI-E Inches 41 27-7/8 40 26-7/8 Millimeters 1041 708 1016 683 SL-550TRS-IPI-E Inches 36-1/2 24-3/8 35-1/2 23-3/8 Millimeters 927 619 902 594 SL-350TRS-D Inches 35-1/2 22-3/8 34-1/2 21-3/8 Millimeters 902 568 876 543 [...]
-
Pagina 26
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 26 C. V ertical Penetration Framing Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/ fl oor (see Figure 6.4). • Frame the area with the same sized lumber as used i[...]
-
Pagina 27
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 27 2 SCREWS A. T op V ent Figure 7.4 Remove the vent cap. Figure 7.5 Remove the insulation basket and white insula- tion from the center vent pipe. Figure 7.1 For top vent, remove the two screws holding the top heat shield in place. For rea[...]
-
Pagina 28
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 28 Figure 7.6 Remove the insulation from the outer vent pipe. Figure 7.7 T o attach the fi rst section of vent pipe, make sure to use the fi berglass gasket to seal between the fi rst vent component and the outer fi replace wrap. Use 2 [...]
-
Pagina 29
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 29 C. Securing and Leveling the Appliance The diagram shows how to properly position, level, and secure the appliance (see Figure 7.13). Nailing tabs are pro- vided to secure the appliance to the framing members. • V enting - refer to V e[...]
-
Pagina 30
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 30 A. Assembly of V ent Sections (DVP Pipe) Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 1-1/2 inches. • Use pilot holes for screws. • Screws must not exceed one inch long. • P[...]
-
Pagina 31
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 31 Assembling DVP-12A Slip Sections The outer fl ue of the slip section should slide over the outer fl ue of the pipe section and into (inner fl ue) the last pipe section (see Figure 8.6). Slide together to the desired length, making sur[...]
-
Pagina 32
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 32 B. Disassembly of V ent Sections (DVP Pipe) T o disassemble any two pieces of pipe, rotate either section (see Figure 8.10), so that the seams on both pipe sections are aligned (see Figure 8.1 1). They can then be carefully pulled apart.[...]
-
Pagina 33
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 33 C. Installing Heat Shield and Horizontal T ermination Cap (DVP Pipe) Note: Where required, an exterior wall fl ashing is available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Installing the [...]
-
Pagina 34
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 34 D. Assembly of V ent Sections (SL pipe) Continue Adding V ent Components • Continue adding vent components, locking each suc- ceeding component into place. • Ensure that each succeeding vent component is securely fi tted and locked [...]
-
Pagina 35
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 35 E. Installing W all Shield Firestops and Horizontal T ermination Cap (SL Pipe) NOTE: Where required, an exterior wall fl ashing is available. When penetrating a brick wall, a brick extension kit is avail- able for framing the brick. Ins[...]
-
Pagina 36
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 36 SCREWS CAULK STORM COLLAR (1 of 3) F . Installing Roof Flashing and V ertical T er- mination Cap T o install roof fl ashing see Figure 8.18. For installation of vertical termination cap see minimum vent heights for various pitched roofs[...]
-
Pagina 37
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 37 Figure 8.19 Assembling the Storm Collar Figure 8.20 Assembling the Storm Collar Around the Pipe Connect both halves of the storm collar with two screws (see Figure 8.19). Wrap the storm collar around the exposed pipe section and align br[...]
-
Pagina 38
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 38 Note: H a ve the gas supply line install ed in acco rdance w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 . Installation shou ld b e done by a quali fi ed installer approv ed and/or li c[...]
-
Pagina 39
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 39 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are teste[...]
-
Pagina 40
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 40 1 0 10 Elec tric al Information Note: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Elec[...]
-
Pagina 41
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 41 TRANSFORMER 3 V AC PLUG IN BLACK RED BA TTERY P ACK THERMOST A T WIRE ASSEMBL Y WIRES (TO BROWN) ORANGE GREEN VA LV E WHITE ORANGE IGNITION MODULE 3 V AC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS C. Intelli ?[...]
-
Pagina 42
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 42 TRANSFORMER 3 V AC PLUG IN PLUG IN BLACK RED BA TTERY P ACK REMOTE WIRES (TO BROWN) ORANGE GREEN VA LV E GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 V AC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S Figure 10.4 Intelli fi r[...]
-
Pagina 43
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 43 E. Junction Box Installation WHT WHT BLK BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebox Romex Connector Figure 10.5 Junction Box Detail If the box is being wired from the OUTS[...]
-
Pagina 44
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 44 5 6 7 8 9 10 3 4 5 12 11 10 9 8 7 6 TOP OF HOOD OR FIREPLACE OPENING 4 12 13 11 32 CEILING A. Mantel Projections Figure 1 1.1 shows the minimum vertical and correspond- ing maximum horizontal dimensions of appliance mantels or other comb[...]
-
Pagina 45
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 45 Note: There are 3 metal tabs holding the non-combustible board in place for shipping. These tabs are to be cut off or bent back before fi nishing around the appliance front. 0 IN. 0 IN. 0 IN. NON-COMBUSTIBLE BOARD (INCLUDED) HIGH TEMPER[...]
-
Pagina 46
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 46 C. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process be- fore fi nishing work on the whole hearth is complete. Splatter guards may be factory installed or a[...]
-
Pagina 47
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 47 Step 5. Fold bottom fl ap along score line as indicated in Figure 1 1.10 and tuck into valve access area of appli- ance. Splatter guard should fi t securely on front of unit. Figure 1 1.10 Once plumbing and wiring are complete on the ?[...]
-
Pagina 48
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 48 UNITS AND TEMPLA TE P ART # SL-350TRS-D (350-T emplate) SL-550TRS-IPI-E (550-T emplate) SL-750TRS-IPI-E (750-T emplate) DOOR FIT FINISH MA TERIAL THICKNESS SEE FIGURE XY Aero-28 Inside 4 inches Max. 1 1.16 N/A N/A Aero-32 Inside 4 inches[...]
-
Pagina 49
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 49 1 2 12 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the co[...]
-
Pagina 50
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 50 E. Install Refractory SL-550TRS-IPI-E and SL-750TRS-IPI-E only . Figure 12.7 Figure 12.6 Figure 12.8 Step 2. Place the right refractory against the fi rebox right wall such that it is against the back refractory (see Figure 12.7). Step [...]
-
Pagina 51
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 51 Model: SL-350TRS-D F . Positioning the Logs CAUTION: Logs are fragile. Log #1 (SR V21 13-701) : Locate the slot on the bottom right side of log 1. Mate the slot with the right rear log tab. Pull the front left nose of log #1 forward unti[...]
-
Pagina 52
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 52 Figure 6 Figure 6 Mate shoulder screw with notch Mate shoulder screw with notch Log #4 (SRV21 13-703) : Locate the notch on the bottom of log # 4. Mate the notch with the shoulder screw that is located on the burner top. Mate the rear gr[...]
-
Pagina 53
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 53 Model: SL-550TRS-IPI-E STEP 1. CAUTION: Logs are fragile! Carefully remove the logs from the packaging. 1 1 2 2 STEP 2. LOG #1 (SRV2065-704) Place log #1 on left fl at side of the burner assembly . Pull the log and slide it to the right[...]
-
Pagina 54
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 54 STEP 4. LOG #3 (SRV2065-702) Place log #3 on right side of grate. The notch on the log should fi t over the bar on the far right side of the grate. Push the right side of log #3 against the grate tab and push the left side back until it[...]
-
Pagina 55
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 55 Model: SL-750TRS-IPI-E STEP 1. CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG NOTCHES STEP 2. LOG #1 (SRV2066-704) Place log #1 on left fl at side of the burner assembly . Pull the log forward and slide it [...]
-
Pagina 56
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 56 STEP 4. LOG #3 (SRV2066-702) Place log #3 on right side of grate. The notch on the log should fi t over the bar on the far right side of the grate. Push the right side of log #3 against the grate tab and pull the left side forward until[...]
-
Pagina 57
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 57 SL-350TRS-D SL-350TRS-IPI 3/16 in. SL-350TRS-D (LP) SL-350TRS-IPI (LP) 1/4 in. SL-550TRS-IPI-E 3/8 in. SL-550TRSIPILPE Fixed SL-750TRS-IPI-E 3/8 in. SL-750TRSLPIPIE Fixed Figure 12.2 Glass Assembly G. Glass Assembly Removing Glass Assemb[...]
-
Pagina 58
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 58 A. Before Lighting Appliance Before lighting this appliance determine if it has a Stand- ing Pilot or Intelli fi re ignition system by opening the con- trol access panel to view wiring system and gas valve. If this appliance has a red o[...]
-
Pagina 59
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 59 B. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. 3. Wait fi ve (5) minutes to c[...]
-
Pagina 60
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 60 Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF?[...]
-
Pagina 61
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 61 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn[...]
-
Pagina 62
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 62 A. Standing Pilot Ignition System 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will[...]
-
Pagina 63
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 63 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile termin[...]
-
Pagina 64
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 64 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. The ignitor/module makes noise, but no spark. a. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected [...]
-
Pagina 65
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 65 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3. (Continued) Pilot lights but continues to spark, and main burner will not ignite. (If the pilot contin- ues to spark after the pilot fl ame has bee[...]
-
Pagina 66
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 66 1 5 15 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the begin[...]
-
Pagina 67
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 67 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .[...]
-
Pagina 68
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 68 1 6 16 R eference Mater ials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3. Figure 16.1 Appliance Dimensions SL-350TRS-D SL-550[...]
-
Pagina 69
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 69 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 1[...]
-
Pagina 70
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 70 B. V ent Components Diagrams ( continued ) Figure 16.3 DVP vent components T erm Cap Minimum Effective Length Maximum Effective Length T rap1 4-1/8 in. 5-5/8 in. 105 mm 143 mm T rap2 6-3/4 in. 10-5/8 in. 171 mm 270 mm DVP-HPC1 DVP-HPC2 D[...]
-
Pagina 71
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 71 B. V ent Components Diagrams ( continued ) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashi[...]
-
Pagina 72
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 72 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 [...]
-
Pagina 73
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 73 B. V ent Components Diagrams (continued) 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm Figure 16.6 DVP [...]
-
Pagina 74
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 74 There must be a 25% reduction in total H when using the snorkel cap except when using the simple up and out installation. 6-1/2 in. (For use on Intellifire appliances only) SL-90D HORIZONTAL PIPE SUPPORT (SL-SERIES) WALL BRACKET (SL-SERI[...]
-
Pagina 75
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 75 SL-350TRS-D , SL-350TRS-IPI Service Parts Service Parts Diagram Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 5 6 7 8 Part number list on following page. Log Set Assembly 1 2 3 4 Î[...]
-
Pagina 76
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 76 C. Service Parts List SL-350TRS-D, SL-350TRS-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service part[...]
-
Pagina 77
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 77 SL-350TRS-D Service Parts V alve Assembly Parts List Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 1 2 3 4 5 6 7 8 9 Standing Pilot V alve Assembly IMPORT ANT : THIS IS DA TED INFORMA TION. The most current in[...]
-
Pagina 78
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 78 IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTI[...]
-
Pagina 79
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 79 SL550TRS-IPI-E Service Parts Service Parts Diagram 6 7 8 9 10 11 12 13 14 Part number list on following page. Log Set Assembly 1 2 3 4 5 Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active[...]
-
Pagina 80
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 80 SL-550TRS-IPI-E Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE[...]
-
Pagina 81
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 81 SL-750TRS-IPI-E Service Parts Service Parts Diagram Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 10 7 8 11 12 13 14 9 6 Part number list on following page. Log Set Assembly 1 2 3 4 5[...]
-
Pagina 82
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 82 SL-750TRS-IPI-E IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE TO SHIP IN 24 HOUR[...]
-
Pagina 83
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 83 IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. A V AILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTI[...]
-
Pagina 84
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 84 © 2005 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981D 3/05 D. Limited Lifetime W arranty BASIC ONE-YEAR W ARRANTY . HEA T & GLO, a brand of HEAR TH & HOME TECHNOLO[...]
-
Pagina 85
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev . D • 6/07 85 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the lo[...]