Hearth and Home Technologies SL-550TRSI-AUE manuale d’uso
- Visualizza on-line o scarica il manuale
- 40 pagine
- 2.29 mb
Vai alla pagina of
Manuali d’uso simili
-
Electric Heater
Hearth and Home Technologies SFE-35C
12 pagine 1.82 mb -
Electric Heater
Hearth and Home Technologies Bravo
61 pagine 3.59 mb -
Electric Heater
Hearth and Home Technologies Aztec
61 pagine 3.59 mb -
Electric Heater
Hearth and Home Technologies SL-350TRSI-AUE
38 pagine 2.14 mb -
Electric Heater
Hearth and Home Technologies SL-550TRSI-AUE
40 pagine 2.29 mb -
Electric Heater
Hearth and Home Technologies SFE-35
12 pagine 1.82 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Hearth and Home Technologies SL-550TRSI-AUE. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Hearth and Home Technologies SL-550TRSI-AUE o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Hearth and Home Technologies SL-550TRSI-AUE descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Hearth and Home Technologies SL-550TRSI-AUE dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Hearth and Home Technologies SL-550TRSI-AUE
- nome del fabbricante e anno di fabbricazione Hearth and Home Technologies SL-550TRSI-AUE
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Hearth and Home Technologies SL-550TRSI-AUE
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Hearth and Home Technologies SL-550TRSI-AUE non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Hearth and Home Technologies SL-550TRSI-AUE e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Hearth and Home Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Hearth and Home Technologies SL-550TRSI-AUE, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Hearth and Home Technologies SL-550TRSI-AUE, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Hearth and Home Technologies SL-550TRSI-AUE. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
1 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 MODEL: SL-550TRSI-AUE AUSTRALIAN GAS ASSOCIA TION APPROVED Approval Number 5666 THIS MANUAL MUST BE USED FOR INST ALLA TION AND RET AINED BY HOMEOWNER FOR OPERA TION AND MAINTENANCE. HEA T & GLO, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakevill[...]
-
Pagina 2
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2 IMPORT ANT : Read all instructions carefully before starting inst allation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty . Save this Manual for future reference. MODEL SL-550TRSI-AUE IS AUSTRALIAN GAS ASSOCIA TION A[...]
-
Pagina 3
3 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 T ABLE OF CONTENTS 1.0 Installation Instructions ......................................................................................... 5 1. 1 Introduction ................................................................................................... 6 1.2 Flue System Approva[...]
-
Pagina 4
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 4 Figure 1. Diagram of SL-550TRSI-AUE 25-3/4 i n . (653m m) 12-7 /8 in. (327m m) 15-7/8 i n . (402m m) 16-3 /8 i n. (414m m) 8- 3/4 in . (223m m) Ø 8 2 in. (20 3m m) 36-3 /8 in . (92 4m m) GAS LI N E ACCESS 6 in. (153m m) 2- 1/8 in . (55mm ) 32 in . (813m m) 36 i n . (913m m) 16-1 /8 [...]
-
Pagina 5
5 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 2. Fireplace Dimensions, Locations, and Space Requirements Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front ...................................... 3 6 ........ 9 1 4 Floor ................................................. 0 ........... 0 Rea[...]
-
Pagina 6
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 6 Figure 3. Framing Dimensions Framing should be constructed of 2 X 4 lumber or heavier . The framing headers may rest on the fireplace stand-offs. AB C D * E * 37 in. 33-1/4 in. 16-1/2 in. 43-3/4 in. 23-3/8 in. (940mm) (845mm) (420mm) (1 1 1 1mm) (594mm) *NOTE: The center of the frami[...]
-
Pagina 7
7 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extends to ground level. 3. See clause 5.13.6.6 for restrictions on a flue terminal under a [...]
-
Pagina 8
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 8 TABLE 1 1.2 FLUE SYSTEM APPROV ALS These models have flue starting collars on both the top and the back of the unit. Depending upon the installa- tion, decide which ONE set of starting collars will be used to attach the flue system. The starting collar sealing cap must remain on the [...]
-
Pagina 9
9 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 NOTE: PIPES OVERLAP 32mm A T EACH JOINT . D V P 9 0 S T 319mm 286 mm 184 mm 32mm T Y P 13mm TYP 217mm DVP36 DVP48 1219mm 610 mm 914 mm 102mm 152m m DVP4 DVP6 305mm DVP12 51mm MIN. DVP12A 310 mm MAX. DVP24 251m m 45.0 O 260 mm DVP45 362 mm Figure 6. DVP-Series Balanced Flue Component [...]
-
Pagina 10
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 10 Figure 7. SL D-Series Balanced Flue Component Specifications (4-inch (102mm) inner pipe / 6 5/8-inch (168mm) outer pipe) NOTE: PIPES OVERLAP 1 3/8 INCHES (35mm) A T EACH JOINT . 6 5/8 (168mm) 9 5/8 (244mm) 6 3/8 (162mm) 6 3/8 (162mm) 6 ½ (165mm) 9 5/8 (244mm) SL-90D 6 ½ (165mm) 6 [...]
-
Pagina 11
11 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 VERTICAL FLUEING V FT . (M) 36' MAXIMUM (10.97M) Figure 9. USE SL D-SERIES COMPONENTS ONL Y . Figure 10. USE DVP-SERIES COMPONENTS ONL Y . STRAIGHT OUT HORIZONT AL FLUEING H Max. Run 24" (610mm) V ertical Flue Restrictor If the heater installation requires a vertical flue [...]
-
Pagina 12
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 12 Figure 1 1. V H FT . (M ) FT . (M ) 1' MIN.(0.30M) 2' MAX.(0.61M) 2' MIN.(0.61M) 4' MAX.(1.22M) 3' MIN.(0.91M) 8' MAX.(2.44M) 4' MIN.(1.22M) 10' MAX.(3.05M) V + H = 30' (9.14M) FLUEING WITH ONE (1) 90° ELBOW USE SL D-SERIES COMPONENTS ON[...]
-
Pagina 13
13 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 13. V H FT . (M) FT . (M ) 1' MIN.(0.30M) 2' MAX.(0.61M) 2' MIN.(0.61M) 4' MAX. (1.22M) 3' MIN.(0.91M) 6' MAX. (1.83M) 4' MIN.(1.22M) 8' MAX. (2.44M) 5' MIN.(1.52M) 12' MAX. (3.66M) 12' MAX.(3.66M) NOTE: V + V 1 MAX 33&ap[...]
-
Pagina 14
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 14 V H H 1 Figure 14. USE DVP-SERIES COMPONENTS ONL Y . FLUEING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (0.30M) 1´ MAX. (0.30M) 2´ MAX. (0.61M) 2´ MIN. (0.61M) 2´ MAX. (0.61M) 4´ MAX. (1.22M) 3´ MIN. (0.91M) 3´ MAX. (0.91M) 8´ MAX. (2.44M) 4´ MIN. (1.22M) 4´ MAX. (1.22M[...]
-
Pagina 15
15 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 FLUEING WITH THREE (3) 90° ELBOWS V H H + H 1 FT . ( M) FT . ( M) FT . ( M) 2' MIN.(0.61M) 2' MAX.(0.61M) 4' MAX.(1.22M) 3' MIN.(0.91M) 3' MAX.(0.91M) 6 ' MAX (1.83M) 4' MIN.(1.22M) 4' MAX.(1 .2 2M) 8' MAX.(2.44M) V+V 1 = 30' MAX (9[...]
-
Pagina 16
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 16 Figure 16. FLUEING WITH THREE (3) 90° ELBOWS 1´ MIN. (0.30M) 1´ MAX. (0.30M) 3´ MAX. (0.91M) 2´ MIN. (0.61M) 2´ MAX. (0.61M) 5´ MAX. (1.52M) 3´ MIN. (0.91M) 4´ MAX. (1.22M) 8´ MAX. (2.44M) 4´ MIN. (1.22M) 6´ MAX. (1.83M) 12´ MAX. (3.66M) H = 6´ MAX. (1.83M) H+H 1 = 12?[...]
-
Pagina 17
17 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 17. WARNING: F AILURE TO REMOVE INSULA TION IN THE SET OF COL- LARS YOU ARE USING COULD CAUSE A FIRE. WARNING: THE REAR FLUE COL- LAR SEAL CAP MUST REMAIN A T - T ACHED T O THE REAR FLUE COL- LARS IF THE FLUE SYSTEM IS A T - T ACHED T O THE TOP ST ARTING COLLARS. SEE FIGURE 1[...]
-
Pagina 18
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 18 ! W ARNING: ENSURE THA T THE HEA TER GASKET SUPPLIED WITH THE HEA TER SEALS BETWEEN THE FIRST FLUE COMPO- NENT AND THE OUTER HEA TER WRAP . Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 38 mm. • Screws must not exceed one in[...]
-
Pagina 19
19 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2. Continue Adding Flue Components T o continue adding flue components in accordance with the pre-planned flue system configuration: • Ensure that each succeeding flue component is se- curely fitted and locked into the preceding compo- nent in the flue system. For elbows that are [...]
-
Pagina 20
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 20 For V ertical Runs The flue system must be supported every eight (8) feet (2.4 M) above the heater flue outlet by wall brackets. T o install support brackets for vertical runs: • Attach wall brackets to the flue pipe and secure the wall bracket to the framing members with nails or[...]
-
Pagina 21
21 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 ! Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole. C. Flue T ermination For Horizont al T erminations using the DVP-TRAP T o attach and secure the termination to the last sect[...]
-
Pagina 22
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 22 For V ertical T erminations - T o locate the flue and install the flue sections: • Locate and mark the flue centerpoint on the under- side of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail. • The size of the [...]
-
Pagina 23
23 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 30. IGN IT IO N MOD ULE (6V) ON/OFF WA LL S W IT C H VA LV E FLAME SP ARKER/ SENSO R ANT . REM OTE CON TROL HOT NEUT RA L GROUND BA TTE R Y PORT VA LV E PILOT IGNITI ON MODULE 6V DC ON/OFF SWIT CH TH ERMOCOU P L E BL OCK (C ONNECT E D T O BACK OF VAL VE) GAS LINE CON NECTE D [...]
-
Pagina 24
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 24 Figure 31. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE 105 • C RA TED WIRE. Figure 32. BROW N BROWN BLUE BLAC K BLUE BLAC K (HOT) BROW N (N E U T R A L ) BL UE BL AC K BLACK BLUE BR OW N GREEN/YELLOW BLO W ER T[...]
-
Pagina 25
25 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 33. 1.6 FINISHING The minimum clearance to combustibles are 0 from the sides, floor , back and top (these clearances are defined by the standoffs). The minimum distance to the perpendicular side wall extending past the appliance front is 2-inches (51mm). Clearance to a mantel[...]
-
Pagina 26
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 26 Figure 34. Figure 35. MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOA TING . Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints betwe[...]
-
Pagina 27
27 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 (SRV550-715): Place log #1 onto the log grate so that the notches in the bottom of the log fit on the right three grate bars. Push log #1 towards the rear locating tabs. LOG #2 (SRV347-703): Place log #2[...]
-
Pagina 28
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 28 LOG #4 (SRV278-705): Position log #4 between log #1 and the locating tab on the fourth grate bar . Push its lef t hand side back to the locating tab as the grate bar . LOG #5 (SRV540-704): Put the forked end of log #5 on the base in front of the grate, towards the center of the seco[...]
-
Pagina 29
29 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 LOG #7 (SRV484-703): Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate bar and rest its rear on log #1 as shown. 7 7 8 8 LOG #6 (SRV550-718): Place log #6 on the base on f[...]
-
Pagina 30
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 30 ! ! Figure 36. 2.0 OPERA TING INSTRUCTIONS This appliance is a balanced flue heater and is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases ex- pelled to the outside of the building. W ARNING: THIS UNIT IS NOT FOR USE [...]
-
Pagina 31
31 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2.1 SAFETY & LIGHTING INFORMA TION Follow SAFETY INFORMA TION and LIGHTING IN- STRUCTIONS to light the appliance. By design, the flame pattern will not be identical from unit to unit. Additionally , flame pattern may vary depend- ing on installation type and weather conditions. [...]
-
Pagina 32
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 32 ! 2.2 F AN OPERA TION The accessory fan is wired in series with a speed con- trol switch and a temperature sensor switch. Set the speed control to an "ON" position and light the heater . The temperature sensor switch will automatically start the fan when the switch warms u[...]
-
Pagina 33
33 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 3.1 REMOV AL OF COVERS FOR SERVICING A . Control Compartment Door • Rotate the lower door down to access the gas controls. B . Dress Guard and Glass Door • Lift the front dress guard up and out away from the appliance side surrounds. Replace the dress guard when servicing is com[...]
-
Pagina 34
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 34 I nspect Mai n tenance T asks Doors 1. I n spect for scrat ch es, den t s or ot h er damage an d r e pai r as n ecessar y . 2. V e r i f y n o o bs t r u c t i on s t o a i r f l ow . 3. V eri fy m ai n ten an ce of proper cl earan ce t o combu st i b le h ou seh ol d object s. Gas [...]
-
Pagina 35
35 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 3.6 TROUBLESHOOTING With proper installation and maintenance, your new Gas Heater should provide years of trouble-free service. If you do experience a problem, refer to the T rouble Shooting Guide below . This guide will assist a qualified service person in the diagnosis of problems[...]
-
Pagina 36
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 36 Electronic Ignition System - (continued) Sym pt om P o s s ib le C a u s e s Co rrect ive A cti o ns 10. G lass soot s. a. Fl ame impin gemen t on lo g s . A d just the lo g s e t s o that the fla me d o e s not i mp i ng e o n i t . b. I mpr oper v en tu r i sett i n g. A d ju st t[...]
-
Pagina 37
37 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 (NG , LP) Exploded Parts Diagram Service Parts SL-550TRSI-AUE Beginning Manufacturing Date: 6/06 Ending Manufacturing Date: ______ 22 Log set assembly 19 6 23 25 27 24 26 28 30 29 10 16 17 2 1 3 18 15 14 13 12 7 8 11 9 21 4 33 37 32 31 20 34 36 5 35 38 39 40[...]
-
Pagina 38
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 38 SL-550TRSI-AUE Service Parts List IMPORT ANT : When ordering, supply serial and model numbers to ensure correct service parts. IT E M PAR T S PAR T N U M B E R 1 Va lve NG 2098-130 Va lve L P 2098-131 2 O r if ice N G 58 2- 84 0 O rif i ce LP 582-057 3 Fl ex ibl e G as Con n ect or [...]
-
Pagina 39
39 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 LIMITED 10 YEAR WARRANTY HEAT & GLO, a brand of Hearth & Home Technologies Inc. In order to presumptively establish the dates to which your HEAT & GLO Limited 10 Year Warranty runs, you must mail the completed warranty card to HEAT & GLO, a brand of Hearth & Home[...]
-
Pagina 40
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 40 For Service or Replacement Part s Cont act: Melbourne Jetmaster 444 Swan S treet Richmond 3121 (03) 9429-5573 Perth Fireplace Corner 277 Lord S treet East Perth 6000 (08) 9228-2600 Sydney Jetmaster 10 Martin A venue Arncliff 2205 (02) 9597-7222[...]