HP (Hewlett-Packard) MSL8096
4 pagine 0.42 mb -
Computer Drive
HP (Hewlett-Packard) LTO-4 1840
24 pagine 0.45 mb -
Computer Drive
HP (Hewlett-Packard) 1900ux
80 pagine 1.6 mb -
Computer Drive
HP (Hewlett-Packard) 2300ux
80 pagine 1.6 mb -
Computer Drive
HP (Hewlett-Packard) 1500 cs
26 pagine 0.18 mb -
Computer Drive
HP (Hewlett-Packard) 600
52 pagine 1.35 mb -
Computer Drive
HP (Hewlett-Packard) LP 1000r
3 pagine 0.05 mb -
Computer Drive
HP (Hewlett-Packard) 3800ux
13 pagine 0.16 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System
- nome del fabbricante e anno di fabbricazione HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio HP (Hewlett-Packard) in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso HP (Hewlett-Packard) StorageWorks Modular Smart Array 500 System. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide (formerly Smart Array Cluster Storage System) October 2003 (Fourth Edition) Part Number 251850-004[...]
-
Pagina 2
HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM © 2002, 2003 Hewlett-Packard De velopment Company, L.P. Microsoft®, Windows®, and Windows NT® are trademarks of Microsoft Corporation in the U.S. and other countries. Hewlett-Packard Company shall not be liable for technica l or editorial errors or omissio[...]
-
Pagina 3
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide iii HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM Contents About This Guide Audience Assumptions ........................................................................................................... .......................[...]
-
Pagina 4
Contents iv HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM Chapter 4 Component Identification Front Panel Components ......................................................................................................... .......[...]
-
Pagina 5
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide v HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM About This Guide This maintenance and service guide can be used for reference when servicing the HP StorageWorks Modular Smart Array 500 system. WARNING: To reduce the risk of pers[...]
-
Pagina 6
About This Guide vi HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:52 AM CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the system. CAUTION: The equipment is de[...]
-
Pagina 7
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 1-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:55 AM 1 Illustrated Parts Catalog Mechanical and System Components 6 3 5 2 8 7 1 4[...]
-
Pagina 8
Illustrated Parts Catalog 1-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:55 AM Table 1-1: Mechanical and System Components Item Description Spare Part Number Mechanical Components 1 Chassis, 4U, with backplane 229198-001 2 Bezel bl[...]
-
Pagina 9
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM 2 Removal and Replacement Procedures To service the MSA500 system, you may need the following tools: • Flat-blade screwdriver • From the SmartStart CD: — Advanced Diagnosti[...]
-
Pagina 10
Removal and Replacement Proced ures 2-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Rack Warnings and Cautions WARNING: Because the rack allows stacking of computer components on a vertical rather than horizontal plane, be sur[...]
-
Pagina 11
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM WARNING: Be sure that the AC power supply branch circuit that provides power to the rack is not overloaded. Not overloading AC power to the ra[...]
-
Pagina 12
Removal and Replacement Proced ures 2-4 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM System Power Down WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove [...]
-
Pagina 13
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-5 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Hot-Plug SCSI Hard Drive CAUTION: If you must replace a hot-plug drive, follo w the guide lines in this section. Failure to do so can result i[...]
-
Pagina 14
Removal and Replacement Proced ures 2-6 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM To remove the component: 1. Be sure that the online and activity LEDs on the failed drive are both off. CAUTION: To prevent improper cooling a[...]
-
Pagina 15
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-7 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Universal Hot-Plug Tape Drive To remove the component: CAUTION: To prevent improper cooling an d t hermal damage, do not operate the system un[...]
-
Pagina 16
Removal and Replacement Proced ures 2-8 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Bezel Blank To remove the component: CAUTION: Always populate bays with either a compon ent or bla nk. Proper airflow can only be maintained w[...]
-
Pagina 17
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-9 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM HP StorageWorks Modular Smart Array 500 Controller When the MSA500 controller in a single-contro ller system fails, HP recommends that you mig[...]
-
Pagina 18
Removal and Replacement Proced ures 2-10 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Battery-Backed Cache Module CAUTION: To prevent data loss or equipment dam age, follow the instruct ions in this procedure. To remove the com[...]
-
Pagina 19
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-11 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Blower To remove the component: WARNING: The blower blades rotate at a high speed. Avoid touching the rotating blades when removing the blowe[...]
-
Pagina 20
Removal and Replacement Proced ures 2-12 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Hot-Plug Power Supply Observe the following cautions for AC power supplies: CAUTION: Removing a power supply signifi cantly ch anges the airf[...]
-
Pagina 21
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-13 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM To remove the component: 1. Disconnect the power cord from the power supply. 2. Remove the blower. Refer to “Blower” in this chapter. 3. [...]
-
Pagina 22
Removal and Replacement Proced ures 2-14 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM 2-Port and 4-Port Shared Storage Modules To remove the component: 1. Power down the system. Refer to “S ystem Power Down” in this chapter[...]
-
Pagina 23
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-15 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Interconnect Blank To remove the component: CAUTION: Always populate interconnect bays with a blank. Proper airflo w can only be maintained w[...]
-
Pagina 24
Removal and Replacement Proced ures 2-16 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM Power Button/LED Assembly To remove the component: 1. Power down the system. Refer to “S ystem Power Down” in this chapter. 2. Remove the[...]
-
Pagina 25
Removal and Replacement Proced ures HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 2-17 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:57 AM MSA500 System Chassis and Backplane If the backplane board fails or the chassis sustains significant damage, you must order a replacement cha[...]
-
Pagina 26
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 3-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM 3 Diagnostic Tools Server Utilities HP utilities provide reporting functions that enable event-focused management and diagnostics. To install and run these util ities, refer to t[...]
-
Pagina 27
Diagnostic Tools 3-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM ROM Upgrades Each MSA500 controller has a ROM that contains the controller firmware. The ROM flash tool enables system administra tors to efficiently upgrade arr[...]
-
Pagina 28
Diagnostic Tools HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 3-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 10:59 AM NetWare Online Array Configuration Utility (CPQONLIN) The NetWare Online Array Configuration U tility, also called CPQONLIN, is a NetWare Loadable Module (NLM) f[...]
-
Pagina 29
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4 Component Identification Front Panel Components 1 3 4 2 7 6 5 Table 4-1: Front Panel Components Item Description 1 Bezel blank (bay for optional redunda nt controller) 2 Servic[...]
-
Pagina 30
Component Identification 4-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Enclosure LEDs 1 2 3 Table 4-2: Enclosure LEDs Item LED Description Status 1 Environmental Monitoring Unit (EMU) heartbeat Green flashing = Shared storag[...]
-
Pagina 31
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Rear Panel Components 1 2 4 3 Table 4-3: Rear Panel Components Item Description 1 Interconnect blanks (Required for proper airfl ow) 2 Power supply/blowe[...]
-
Pagina 32
Component Identification 4-4 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 2-Port Shared Storage Module Components 1 2 Table 4-4: 2-Port Shared Storage Module Components Item Connector Description Bus 1 SCSI port connector A 2 S[...]
-
Pagina 33
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-5 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 2-Port Shared Storage Module LEDs 1 2 3 Table 4-5: 2-Port Shared Storage Module LEDs Item LED Description Status 1 Power Green = Power on Off = Power off[...]
-
Pagina 34
Component Identification 4-6 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4-Port Shared Storage Module Components 2 1 4 3 Table 4-6: 4-Port Shared Storage Module Components Item Connector Description Bus 1 SCSI port connector A[...]
-
Pagina 35
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-7 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM 4-Port Shared Storage Module LEDs 1 2 3 Table 4-7: 4-Port Shared Storage Module LEDs Item LED Description Status 1 Power Green = Power on Off = Power off[...]
-
Pagina 36
Component Identification 4-8 HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guid e HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Controller Components Controller Display Each MSA500 controller has an LCD displa y for informational and error messages. 1 2 3 4 5 Table 4-8: Controller[...]
-
Pagina 37
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-9 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Controller LEDs 15 7 14 6 13 5 12 4 11 3 10 2 9 1 8 17 0 16 Table 4-9: Controller LEDs Item LED Description Status 0-2 Busy status Green = Controller is [...]
-
Pagina 38
Component Identification 4-10 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Table 4-9: Controller LEDs continued Item LED Description Status 14 Cache activity Green = Cache activity Off = No cache activity Flashing green = Cache[...]
-
Pagina 39
Component Identification HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 4-11 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM SCSI IDs 14 7 6 5 4 3 2 1 8 9 10 11 12 13 Table 4-10: SCSI IDs Bay SCSI ID Bus Port 1 0 2 1 3 2 4 3 5 4 6 5 7 8 0 8 0 9 1 10 2 11 3 12 4 13 5 14 8 1[...]
-
Pagina 40
Component Identification 4-12 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:00 AM Hot-Plug SCSI Hard Drive LEDs 1 2 3 Table 4-11: Hot-Plug SCSI Hard Drive LEDs Item LED Description 1 Activity 2 Online 3 Fault Hot-Plug SCSI Hard Drive [...]
-
Pagina 41
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 5-1 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM 5 Specifications System Unit Specification Table 5-1: System Unit Specifications Specification Value Dimensions Height 17.5 cm (6.9 in) Depth 52.1 cm (20.5 in) Width 48.3 cm (19.[...]
-
Pagina 42
Specifications 5-2 HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM Table 5-1: System Unit Specifications continued Specification Value Relative humidity (nonconde nsing) Operating 10% to 90% Nonoperating up to 95% Maximum wet bulb[...]
-
Pagina 43
Specifications HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide 5-3 HP CONFIDENTIAL Codename: Aurora Part Num ber: 251850-004 Last Saved On: 9/19/03 11:04 AM Hot-Plug AC Power Supply Table 5-4: Hot-Plug Po wer Supply Specifications Specification Value Height 12.7 cm (4.5 in) Width 15.9 cm (6.25 in) Depth 24.1 cm (9.5 in[...]
-
Pagina 44
HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide Index-1 COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM Index Symbols and Numbers 2-Port Shared Storage M odule components 4-4 LEDs 4-5 location 4-3 removing 2-14 replacing 2-14 spare part number 1- 2 4-Port Shared Storage M [...]
-
Pagina 45
Index Index-2 HP StorageWorks Modular Smart Array 500 System Maintenance an d Service Guide COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM drives See h ot-plug SC SI hard dri ves; tape drives E EMU heartbeat LED 4-2 enclosure LE Ds 4-1, 4-2 F fault LED s 4-2, 4-10 , 4-12 front panel comp onents 4-1 G [...]
-
Pagina 46
Index HP StorageWorks Modular Smart Array 500 System Maintenance and Se rvice Guide Index-3 COMPAQ CONFIDE NTIAL Codename: Aurora Part Number: 2518 50-004 Last Saved On: 9/19/03 11:03 AM backplane 2-17 battery-backed cache module 2-10 bezel blank 2-8 blower 2-1 1 chassis 2-17 hard drive blank 2-4 hot-plug SCSI hard drives 2-6 interconnect blank 2-1[...]