Vai alla pagina of
Manuali d’uso simili
-
Welder
Lincoln Electric POWER MIG 255XT
8 pagine 0.85 mb -
Welder
Lincoln Electric CLASSIC 300G 10659
33 pagine 0.58 mb -
Welder
Lincoln Electric IM959
22 pagine 0.84 mb -
Welder
Lincoln Electric Pipeliner 200D
4 pagine 0.61 mb -
Welder
Lincoln Electric IM294-C
148 pagine 3.58 mb -
Welder
Lincoln Electric 10659
33 pagine 0.55 mb -
Welder
Lincoln Electric IM738-A
36 pagine 2.09 mb -
Welder
Lincoln Electric IM10019
41 pagine 1.29 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Lincoln Electric IM665. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Lincoln Electric IM665 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Lincoln Electric IM665 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Lincoln Electric IM665 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Lincoln Electric IM665
- nome del fabbricante e anno di fabbricazione Lincoln Electric IM665
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Lincoln Electric IM665
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Lincoln Electric IM665 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Lincoln Electric IM665 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Lincoln Electric in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Lincoln Electric IM665, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Lincoln Electric IM665, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Lincoln Electric IM665. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
PRO-CUT TM 25 OPERA TOR’S MANUAL IM665 January, 2001 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANU[...]
-
Pagina 2
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________[...]
-
Pagina 3
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin[...]
-
Pagina 4
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C[...]
-
Pagina 5
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits [...]
-
Pagina 6
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay par[...]
-
Pagina 7
T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions ................................[...]
-
Pagina 8
A-1 INST ALLA TION A-1 W eight Including T orch Cab le 35 lbs. 15.9 kg. INPUT - SINGLE PHASE / 60 HER TZ ONL Y RA TED OUTPUT OUTPUT RECOMMEND INPUT WIRE AND FUSE SIZES REQUIRED GAS FLO W RA TE REQUIRED GAS INLET PRESSURE PHYSICAL DIMENSIONS TECHNICAL SPECIFICA TIONS - PR O-CUT 25 (K1756-1) Standar d V olta ge Duty Cyc le 20% on 115 V 60% on 115 V 1[...]
-
Pagina 9
A-2 INST ALLA TION PRO-CUT 25 A-2 Read entire Installation Section before installing the PRO-CUT 25. SAFETY PRECA UTIONS ELECTRIC SHOCK CAN KILL. • Only qualified personnel should install this machine. • Turn the input power OFF at the disconnect switch or fuse box and discharge input capacitors before working inside the equipment. • Do not t[...]
-
Pagina 10
A-3 INST ALLA TION PRO-CUT 25 A-3 securely. WARNING: Failure to wire as instructed may cause personal injury or damage to equipment. To be installed or checked by an electrician or quali - fied person only. Use of normal 20 amp household breakers may result in over current trips. If breaker trips occur, reduce the cutting current output until nui- [...]
-
Pagina 11
A-4 INST ALLA TION PRO-CUT 25 A-4 NOTE: When using nitrogen gas from a cylinder, the cylinder must have a pressure regulator. • Maximum psi from a nitrogen gas cylinder to the PRO-CUT 25 regulator should never exceed 150 psi. • Install a hose between the nitrogen gas cylinder regulator and the PRO-CUT 25 gas inlet . CYLINDER could explode if da[...]
-
Pagina 12
B-1 OPERA TION PRO-CUT 25 B-1 SAFETY PRECA UTIONS DESCRIPTION The PRO-CUT 25 is a constant current, continuous control plasma cutting power source. It provides supe- rior and reliable starting characteristics, cutting visibili- ty and arc stability. The control system has a safety mechanism to insure that the nozzle and electrode are in place befor[...]
-
Pagina 13
B-2 OPERA TION B-2 USER RESPONSIBILITY Because design, fabrication, erection and cutting vari- ables affect the results obtained in applying this type of information, the serviceability of a product or struc- ture is the responsibility of the user. Variation such as plate chemistry, plate surface condition (oil, scale), plate thickness, preheat, qu[...]
-
Pagina 14
B-3 OPERA TION B-3 CUTTING CAP ABILITY The PRO-CUT 25 is rated at 25 amps, at 35% duty cycle on a 10 minute basis. If the duty cycle is exceeded, a thermal protector will shut off the output of the machine until it cools to the normal operating temperature. Figure B.1 shows the cut capacity of the PRO-CUT 25 when cutting mild steel. (The graph plot[...]
-
Pagina 15
LIMIT A TIONS Do not exceed output current and duty cycle rating of machine. Do not use the PRO-CUT 25 for pipe thaw- ing. CONTR OLS AND SETTINGS When preparing to cut, position the machine as close to the work as possible. Make sure you have all materials needed to complete the job and have taken all safety precautions. It is important to follow t[...]
-
Pagina 16
Direction of Travel 5 ° - 15 ° 10 ° - 20 ° Arc Lag Leading Angle B-5 OPERA TION B-5 • Use a 5 ° - 15 ° leading angle in the direction of the cut. • Finish the cut to be made and release the trigger. • When the trigger is released, the arc will stop. - The gas will continue to flow for 10 seconds of postflow. If the trigger is activated [...]
-
Pagina 17
B-6 OPERA TION B-6 PR OCEDURE RECOMMEND A TIONS When properly used, plasma arc cutting is a very eco- nomical process. Improper use will result in a very high operating cost. General - In All Cases • Follow safety precautions as printed throughout this operating manual and on the machine. • If piercing is required, slowly lower the torch at an [...]
-
Pagina 18
C-1 A CCESSORIES C-1 AL WA YS USE GENUINE LINCOLN ELECTRIC ELECTR ODES AND V OR TECH ™ NOZZLES • Only Genuine Lincoln Electric consumables yield the best cutting performance for the PRO-CUT 25. • The patented VORTECH ™ nozzle provides an extra “ kick ” of swirl as the arc exits the nozzle which improves cutting performance. No other noz[...]
-
Pagina 19
D-1 MAINTENANCE D-1 PRO-CUT 25 THERMAL PRO TECTION Thermal Detection Devices protect the machine from excessive operating temperatures. Excessive temper- atures may be caused by a lack of cooling air or oper- ating the machine beyond the duty cycle and output rating. If excessive operating temperatures should occur, the yellow thermal LED will ligh[...]
-
Pagina 20
E-1 TR OUBLESHOO TING E-1 PRO-CUT 25 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UTION This Troubleshooting Guide is provided to help you locate and repair po[...]
-
Pagina 21
E-2 TR OUBLESHOO TING E-2 PRO-CUT 25 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UTION PROBLEMS [...]
-
Pagina 22
E-3 TR OUBLESHOO TING E-3 PRO-CUT 25 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UTION PROBLEMS [...]
-
Pagina 23
E-4 TR OUBLESHOO TING E-4 PRO-CUT 25 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UTION PROBLEMS [...]
-
Pagina 24
E-5 TR OUBLESHOO TING E-5 PRO-CUT 25 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UTION PROBLEMS [...]
-
Pagina 25
E-6 TR OUBLESHOO TING E-6 PRO-CUT 25 Observe all Safety Guidelines detailed throughout this manual ST A TUS BO ARD INDICA T ORS SYMPT OM The Air Low LED is lit The Safety LED is lit and steady The Thermal LED is lit CHECK 1. Make sure there is at least 80 psi connected to the gas connec- tion at the back of the machine. 2. Press the Purge button an[...]
-
Pagina 26
F-1 DIA GRAMS F-1 PRO-CUT 25 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.[...]
-
Pagina 27
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA [...]
-
Pagina 28
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes[...]
-
Pagina 29
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products •[...]