Vai alla pagina of
Manuali d’uso simili
-
Welding System
Lincoln Electric IM305-C
200 pagine 5.43 mb -
Welding System
Lincoln Electric C2.410
44 pagine 0.7 mb -
Welding System
Lincoln Electric PRECISION TIG 375 IM703-A
46 pagine 1.16 mb -
Welding System
Lincoln Electric CLASSIC III SVM 137-A
128 pagine 1.66 mb -
Welding System
Lincoln Electric PRO-CUT IM595-A
39 pagine 0.81 mb -
Welding System
Lincoln Electric Magnum 100SG
2 pagine 0.82 mb -
Welding System
Lincoln Electric AC-1500
29 pagine 2.24 mb -
Welding System
Lincoln Electric LN- 25 PIPE IM10056
39 pagine 3.77 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Lincoln Electric SVM 119-A. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Lincoln Electric SVM 119-A o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Lincoln Electric SVM 119-A descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Lincoln Electric SVM 119-A dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Lincoln Electric SVM 119-A
- nome del fabbricante e anno di fabbricazione Lincoln Electric SVM 119-A
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Lincoln Electric SVM 119-A
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Lincoln Electric SVM 119-A non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Lincoln Electric SVM 119-A e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Lincoln Electric in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Lincoln Electric SVM 119-A, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Lincoln Electric SVM 119-A, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Lincoln Electric SVM 119-A. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
WIRE-MA TIC 255 SER VICE MANUAL Sales and Service through Subsidiaries and Distributors Worldwide 22801 St. Clair A ve. Cleveland, Ohio 441 17-1 199 U.S.A. T el. (216) 481-8100 World's Leader in W elding and Cutting Products Premier Manufacturer of Industrial Motors SVM 1 19-A January 1996 Safety Depends on Y ou Lincoln arc welding and cutting[...]
-
Pagina 2
W ARNING i SAFETY i WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJUR Y OR DEA TH. KEEP CHILDREN A W A Y . P ACEMAKER WEARERS SHOULD CONSUL T WITH THEIR DOCTOR BEFORE OPERA TING. Read and understand the following safety highlights. For addition[...]
-
Pagina 3
CYLINDER may explode if damaged. 5.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition. 5.b. Always keep cylinders in an upright positi[...]
-
Pagina 4
iii SAFETY iii WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Mar . ‘93 ELECTRIC AND MAG- NETIC FIELDS may be dangerous 8.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). W elding current creates EMF fields around welding cables and welding [...]
-
Pagina 5
iv SAFETY iv WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes[...]
-
Pagina 6
NOTES WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 7
v Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i - v Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section A T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 Safety Precautions[...]
-
Pagina 8
vi Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section E Power Supply Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 Thermal Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-5 SCR Operation . . . . . . . . . . . . . . . [...]
-
Pagina 9
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION WIRE-MA TIC 255 INST ALLA TION SECTION ........................................ Section A T echnical Specifications ...................................................A-1 Safety Precautions ...........................................................A-[...]
-
Pagina 10
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC WIRE-MA TIC 255 Duty Cycle Amps V olts at Rated Amps 100% 145 amps 26 60% 200 amps 28 35% 250 amps 26 Current Range Maximum Open Circuit V oltage Wire Speed Range 30A - 250A 40V [...]
-
Pagina 11
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Read entire Installation Section before installing the WIRE-MA TIC 255 SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should install this machine. • T[...]
-
Pagina 12
A-3 INST ALLA TION WIRE-MA TIC 255 A-3 FUSE AND WIRE SIZES Protect the input circuit with the super lag fuses or delay type circuit breakers listed on the T echnical Specifications page of this manual for the machine being used. The tripping action of delay type circuit breakers decreases as the magnitude of the current increases. They are also cal[...]
-
Pagina 13
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-4 INST ALLA TION WIRE-MA TIC 255 A-4 For the 230/460/575V/ 60 HZ model which is not equipped with a plug, an input cord, or a receptacle, the input power supply leads must be c[...]
-
Pagina 14
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-5 INST ALLA TION WIRE-MA TIC 255 A-5 7. Attach the flow regulator to the cylinder valve and tighten the union nut(s) securely with a wrench. a. NOTE: If connecting the flow reg[...]
-
Pagina 15
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 1. ALL MACHINES ARE SHIPPED FROM THE F ACTOR Y CONNECTED FOR THE HIGHEST NAME- PLA TED SINGLE PHASE INPUT VOL T AGE. TO CHANGE CONNECTIONS FOR A DIFFERENT INPUT VOL T AGE, RECONN[...]
-
Pagina 16
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECT OUTPUT COMPONENTS INST ALL THE WORK CLAMP Attach the work clamp to the cable which extends from the front of the machine using the following procedure: 1. Insert the lug [...]
-
Pagina 17
A-8 INST ALLA TION WIRE-MA TIC 255 A-8 WIRE SIZE CONVERSION P ARTS The Wire-Matic 255 is rated to feed .025" through .045" (0.6-1.2mm) solid or cored electrode sizes. For vari- ous drive roll kits refer to Acessories Section . GUN AND CABLE INST ALLA TION T urn the welder Power Switch OFF before chang- ing output connection. _____________[...]
-
Pagina 18
NOTES WIRE-MA TIC 255 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 19
OPERA TION WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION SECTION ............................................ Section B Safety Instructions ............................................................B-1 General Description..........................................................B-1 [...]
-
Pagina 20
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-1 OPERA TION B-1 Read and understand this entire section before operat- ing your WIRE-MA TIC 255. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. When using a Wire-Matic 255 power[...]
-
Pagina 21
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC POWER SOURCE FEA TURES: 10 Ft. (3.0m) Input Power Cable - Includes plug and mating receptacle for 208/230V unit. Convenient rear reconnect panel allows easy access for 208V re-co[...]
-
Pagina 22
B-3 OPERA TION B-3 WIRE FEEDER FEA TURES: Wire Loading - Adjustable brake spindle mounts Readi-Reel® Adapter , included with WIRE-MA TIC 255, or most any 2" (51mm) I.D. wire spool. Accommodating standard 12" (305mm) and 8" (203mm) diameter coils, the spindle’s adjustable brake provides appropriate dereeling drag to prevent wire re[...]
-
Pagina 23
B-4 OPERA TION B-4 CONTROLS AND SETTINGS All operator controls are located on the Front Panel/Nameplate of the machine. See Figure B.1 for the location of each control. Figure B.1 - Operator Controls. 1. POWER SWITCH: T oggle switch to turn input power ON and OFF . Place the lever in the ON position to turn the WIRE-MA TIC 255 ON. 2. PILOT LIGHT : [...]
-
Pagina 24
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-5 OPERA TION B-5 WIRE-MA TIC 255 USING THE WIRE DRIVE ROLL The drive roll provided with the WIRE-MA TIC 255 has two grooves, one for .030-.035" (0.8-0.9mm) solid steel ele[...]
-
Pagina 25
B-6 OPERA TION B-6 T o mount a 10 to 44 lb. (4.5 to 20 kg) spools: 8” (200mm) [Use K468 Adapter] and 12” (300mm) diameter: 1. Remove the locking collar and the Readi-Reel Adapter (if installed) on the 2 inch (51mm) diame- ter spindle. 2. If using an 8” (200mm) spool, place the K468 Adapter on the spindle first. The hole in the Adapter arm is [...]
-
Pagina 26
B-7 OPERA TION B-7 SETTING IDLE ROLL PRESSURE The idle roll pressure thumb screw is set at the factory backed out 2-1/2 turns from full pressure. This is an approximate setting. The optimum idle roll pressure varies with type of wire, wire diameter , surface condi- tions, lubrication, and hardness. As a general rule, hard wires may require greater [...]
-
Pagina 27
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-8 OPERA TION B-8 WIRE-MA TIC 255 NOTE: Arc starting characteristics may be affected when using the fast run-in mode since optimum start- ing processes are being overriden. When[...]
-
Pagina 28
NOTES WIRE-MA TIC 255 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 29
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACCESSORIES WIRE-MA TIC 255 ACCESSORIES SECTION ....................................... Section C Other Available Magnum 250L Gun and Cable Assembly ..........................................................C-1 Magnum Gun Connection Kit (Optional K466-6) ...........[...]
-
Pagina 30
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC The kit includes a spool gun adapter module assembly with a single connecting plug, a rear gas inlet setting with hose, a gun and cable holders and mounting hardware with install[...]
-
Pagina 31
C-2 ACCESSORIES C-2 MAKING A WELD WITH THE SPOOL GUN ADAPTER (K672-1) INST ALLED In either transfer switch position, closing the gun trigger will cause the electrode of both guns to be electrically "HOT ." Be sure unused gun is posi- tioned so the electrode or the tip will not contact metal case or other metal common to the work. A gun ho[...]
-
Pagina 32
C-3 ACCESSORIES C-3 TIMER KIT (K585-1) The T imer Kit provides selectable 4-step trigger inter- lock, spot and stitch functions, and manual adjustment of burnback time. This kit installs easily using only a screwdriver . It replaces the blank upper panel on Case Front. It offers the following mode selections: • The Normal Welding mode provides we[...]
-
Pagina 33
C-4 ACCESSORIES C-4 MAKING SPOT AND STITCH WELDS WITH TIMER KIT INST ALLED TO MAKE SPOT PLUG WELDS: The SPOT WELD MODE is used to make spot plug welds when continuous welds are not needed or to hold thin sheet metal together prior to stitch welding or continuous welding. Plug welds are made by using a punch to make a 3/16" (5mm) diameter hole [...]
-
Pagina 34
C-5 ACCESSORIES C-5 DUAL CYLINDER MOUNTING KIT (K671-1) Permits stable side-by-side mounting of two full size (9” dia. x 5’ high) gas cylinders with “no lift” loading. Simple installation with installation kick stand and easy instructions provided (L9687). Includes upper and lower cylinder supports, wheel axles and mounting hardware. WIRE-M[...]
-
Pagina 35
MAINTENANCE WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE SECTION ...................................... Section D Safety Precautions ...........................................................D-1 Routine and Periodic Maintenance ..................................D-1 Component Locati[...]
-
Pagina 36
D-1 MAINTENANCE D-1 SAFETY PRECAUTIONS • Have a qualified electrician do the maintenance and troubleshooting work. • Disconnect the input power off using the dis- connect switch at the main input supply before working inside machine. • Unplug the power cable if it is connected to a receptacle. ____________________________________ Read the Saf[...]
-
Pagina 37
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC D-2 MAINTENANCE D-2 Figure D.1 - Component Locations. WIRE-MA TIC 255 FAN MOTORS CONTROL PC BOARD MAIN TRANSFORMER SCR RECTIFIER BRIDGE CHOKE[...]
-
Pagina 38
D-3 MAINTENANCE D-3 DRIVE ROLLS AND GUIDE TUBES After every coil of wire, inspect the wire drive mecha- nism. Clean it as necessary by blowing with low pres- sure compressed air . Do not use solvents for cleaning the idle roll because it may wash the lubricant out of the bearing. All drive rolls are stamped with the wire sizes they will feed. If a [...]
-
Pagina 39
D-4 MAINTENANCE D-4 LINER REMOV AL AND REPLACEMENT NOTE: When you change wire size, a replacement gas diffuser is required. Use the table below to select the proper diffuser so the liner is held securely in place. LINER REMOV AL, INST ALLA TION, AND TRIMMING INSTRUCTIONS FOR MAGNUM 250L NOTE: The variation in cable lengths prevents the interchange [...]
-
Pagina 40
D-5 MAINTENANCE D-5 12 Remove any burrs from the end of the liner . 13. Screw the gas diffuser onto the end of the gun tube and tighten. NOTE: Be sure the gas diffuser is correct for the liner being used. (See table and diffuser stencil.) 14. Slightly tighten the set screw in the side of the gas diffuser against the cable liner using 5/64" (2.[...]
-
Pagina 41
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC D-6 MAINTENANCE D-6 * Included with K673-1 3/64” (1.2 mm) Aluminum Feeding Kit. 5356 alloy aluminum wire recom- mended to alleviate potential soft wire feeding problems with pu[...]
-
Pagina 42
NOTES WIRE-MA TIC 255 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 43
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION WIRE-MA TIC 255 Figure E.1 -Block Logic Diagram NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion THEORY OF OPERA TION SECTION ...................... Section E Power Supply Operation .....................................[...]
-
Pagina 44
E-1 THEOR Y OF OPERA TION E-1 WIRE-MA TIC 255 INPUT LINE VOL T AGE AND MAIN TRANSFORMER The desired single phase input power is connected to the WIRE-MA TIC 255 through a line switch located on the front panel. A reconnect panel allows the user to configure the machine for the desired input voltage. This AC input voltage is applied to the primary o[...]
-
Pagina 45
E-2 THEOR Y OF OPERA TION E-2 WIRE-MA TIC 255 OUTPUT RECTIFICA TION AND FEEDBACK CONTROL The AC output from the main transformer secondary weld winding is rectified and controlled through the SCR rectifier assembly . Output voltage and current are sensed at the shunt and output terminals and are fed back to the control board. The control board com-[...]
-
Pagina 46
E-3 THEOR Y OF OPERA TION E-3 WIRE-MA TIC 255 CONST ANT VOL T AGE OUTPUT The controlled DC output from the SCR rectifier assembly is filtered by the capacitor bank resulting is a constant voltage DC output. Since the output choke is in series with the positive leg of the rectifier and also in series with the gun and welding load, a filtered con- st[...]
-
Pagina 47
E-4 THEOR Y OF OPERA TION E-4 WIRE-MA TIC 255 WIRE DRIVE MOT OR AND FEEDBACK The wire drive motor is controlled by the control board. A motor speed feedback signal is generated at the motor tach and sent to the control board. The control board compares this feedback signal with the com- mands set forth by the Wire Speed Control poten- tiometer and [...]
-
Pagina 48
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC E-5 THEOR Y OF OPERA TION E-5 WIRE-MA TIC 255 THERMAL PROTECTION A thermostat protects the machine from excessive operating temperatures. Excessive operating temper- atures may b[...]
-
Pagina 49
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC E-6 THEOR Y OF OPERA TION E-6 WIRE-MA TIC 255 A silicon controlled rectifier (SCR) is a three terminal device used to control rather large currents to a load. An SCR acts very mu[...]
-
Pagina 50
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES WIRE-MA TIC 255[...]
-
Pagina 51
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR WIRE-MA TIC 255 TROUBLESHOOTING & REP AIR SECTION ........................................................................ Section F How to use T roubleshooting Guide .................................................................[...]
-
Pagina 52
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-1 TROUBLESHOOTING & REP AIR F-1 WIRE-MA TIC 255 This T roubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three[...]
-
Pagina 53
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-2 TROUBLESHOOTING & REP AIR F-2 WIRE-MA TIC 255 _______________________________ CAUTION: Sometimes machine failures appear to be due to PC board failures. These problems ca[...]
-
Pagina 54
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-3 TROUBLESHOOTING & REP AIR F-3 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understan[...]
-
Pagina 55
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-4 TROUBLESHOOTING & REP AIR F-4 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual OUTPUT PROBLEMS PROBLEMS (SYMPTOMS) PO[...]
-
Pagina 56
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-5 TROUBLESHOOTING & REP AIR F-5 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual OUTPUT PROBLEMS PROBLEMS (SYMPTOMS) PO[...]
-
Pagina 57
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-6 TROUBLESHOOTING & REP AIR F-6 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual FUNCTION PROBLEMS PROBLEMS (SYMPTOMS) [...]
-
Pagina 58
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-7 TROUBLESHOOTING & REP AIR F-7 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual WIRE FEEDING PROBLEMS PROBLEMS (SYMPTO[...]
-
Pagina 59
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-8 TROUBLESHOOTING & REP AIR F-8 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual WELDING PROBLEMS PROBLEMS (SYMPTOMS) P[...]
-
Pagina 60
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-9 TROUBLESHOOTING & REP AIR F-9 WIRE-MA TIC 255 TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual WELDING PROBLEMS PROBLEMS (SYMPTOMS) P[...]
-
Pagina 61
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-10 TROUBLESHOOTING & REP AIR F-10 WIRE-MA TIC 255 TEST DESCRIPTION This test will determine if the correct voltages are being: a. Applied to the primary windings of the Mai[...]
-
Pagina 62
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-1 1 TROUBLESHOOTING & REP AIR F-1 1 WIRE-MA TIC 255 MAIN TRANSFORMER TEST TEST PROCEDURE The ON/OFF POWER SWITCH will be "hot" during these tests. _______________[...]
-
Pagina 63
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 TROUBLESHOOTING & REP AIR F-12 WIRE-MA TIC 255 MAIN TRANSFORMER TEST (CONTINUED) Board. a. T urn the machine OFF between each test. b. Carefully insert the meter probes [...]
-
Pagina 64
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-13 TROUBLESHOOTING & REP AIR F-13 WIRE-MA TIC 255 TEST DESCRIPTION This test is used to quickly determine if an SCR or diode is shorted or "leaky ." See the Machi[...]
-
Pagina 65
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-14 TROUBLESHOOTING & REP AIR F-14 WIRE-MA TIC 255 ST A TIC SCR RECTIFIER ASSEMBL Y TEST (CONTINUED) TEST PROCEDURE 1. Disconnect main AC input power to the machine. 2. Disc[...]
-
Pagina 66
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-15 TROUBLESHOOTING & REP AIR F-15 WIRE-MA TIC 255 ST A TIC SCR RECTIFIER ASSEMBL Y TEST (CONTINUED) NOTE: DO NOT DISASSEMBLE THE SCR RECTIFIER HEA T SINK ASSEM- BL Y . 6. T[...]
-
Pagina 67
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-16 TROUBLESHOOTING & REP AIR F-16 WIRE-MA TIC 255 ACTIVE SCR RECTIFIER ASSEMBL Y TEST TEST DESCRIPTION The Active SCR T est will determine if the device is able to be gated[...]
-
Pagina 68
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACTIVE SCR RECTIFIER ASSEMBL Y TEST (CONTINUED) TEST PROCEDURE 1. Disconnect main AC input power to the machine. 2. Disconnect Molex Plugs J3 and J6 from the G2803 Control Board.[...]
-
Pagina 69
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACTIVE SCR RECTIFIER ASSEMBL Y TEST (CONTINUED) 7. Connect the T ester to the SCR 1 as shown in Figure F .7. a. Connect T ester lead (A) to the anode. b. Connect T ester lead (C)[...]
-
Pagina 70
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST DESCRIPTION This test will determine if the wire drive motor and voltage feedback circuit are functioning properly . MA TERIALS NEEDED 5/16" Nut Driver . V olt-Ohmmeter[...]
-
Pagina 71
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-20 TROUBLESHOOTING & REP AIR F-20 WIRE-MA TIC 255 TEST PROCEDURE NOTE: POLARITY MUST BE OBSERVED FOR THESE TESTS. T est for Correct Wire Drive Motor Armature V oltage 1. Di[...]
-
Pagina 72
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-21 TROUBLESHOOTING & REP AIR F-21 WIRE-MA TIC 255 4. T est for 2 - 25 VDC between lead plug location 12J5 #539(B) (posi- tive) (12J5) and lead #541(W) (13J5) (negative) to [...]
-
Pagina 73
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-22 TROUBLESHOOTING & REP AIR F-22 WIRE-MA TIC 255 This is a typical DC output voltage wave- form generated from a properly operating machine. Note that each vertical divisi[...]
-
Pagina 74
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-23 TROUBLESHOOTING & REP AIR F-23 WIRE-MA TIC 255 This is a typical DC output voltage wave- form generated from a properly operating machine. Note that each vertical divisi[...]
-
Pagina 75
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-24 TROUBLESHOOTING & REP AIR F-24 WIRE-MA TIC 255 This is NOT a typical DC output voltage waveform. One output SCR is not function- ing. Note the increased ripple content. [...]
-
Pagina 76
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-25 TROUBLESHOOTING & REP AIR F-25 WIRE-MA TIC 255 This is NOT the typical DC output voltage waveform. The output capacitors are not functioning. Note the lack of “filteri[...]
-
Pagina 77
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-26 TROUBLESHOOTING & REP AIR F-26 WIRE-MA TIC 255 This is a typical SCR gate pulse voltage waveform. The machine was in an open cir- cuit condition (no load) and operating [...]
-
Pagina 78
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Printed Circuit Boards can be damaged by static electricity . Follow static handling guidelines detailed in “PC Board T roubleshooting Procedures” at the beginning of this ch[...]
-
Pagina 79
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-28 TROUBLESHOOTING & REP AIR F-28 WIRE-MA TIC 255 4. Carefully remove the P .C. Board from the mounting standoffs. See Figure F .10. FIGURE F .10 - Control Board Mounting L[...]
-
Pagina 80
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-29 TROUBLESHOOTING & REP AIR F-29 WIRE-MA TIC 255 MA TERIALS NEEDED Large slot head screwdriver . 5/16" Nut Driver . Small slot head screwdriver . WIRE DRIVE ASSEMBL Y[...]
-
Pagina 81
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-30 TROUBLESHOOTING & REP AIR F-30 WIRE-MA TIC 255 PROCEDURE 1. Disconnect main input power to the machine. 2. Remove the Case T op and Side Panels. 3. Using the 5/16” Nut[...]
-
Pagina 82
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-31 TROUBLESHOOTING & REP AIR F-31 WIRE-MA TIC 255 MA TERIALS NEEDED 5/16" Nut driver . 1/2" Open end wrench. 1/2" Socket wrench, universal tool, and extensio[...]
-
Pagina 83
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-32 TROUBLESHOOTING & REP AIR F-32 WIRE-MA TIC 255 PROCEDURE 1. Disconnect lead #208 and T ransformer Lead X1 from the heat sink on the left side of the machine (facing the [...]
-
Pagina 84
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-33 TROUBLESHOOTING & REP AIR F-33 WIRE-MA TIC 255 THE LIQUID ELECTRODE IN THE CAP ACIT ORS IS T OXIC. DO NOT TOUCH THE CAP AC- ITORS WITH ANY P ART OF YOUR BODY . _________[...]
-
Pagina 85
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-34 TROUBLESHOOTING & REP AIR F-34 WIRE-MA TIC 255 PROCEDURE See Figure F .15 for location of Capacitor Bank Removal and Replacement com- ponents. FIGURE F .15 - Location of[...]
-
Pagina 86
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-35 TROUBLESHOOTING & REP AIR F-35 WIRE-MA TIC 255 MA TERIALS NEEDED 5/16" Nut Driver . 1/2" Open end wrench. 3/8" Open end wrench. 1/2" Socket wrench, e[...]
-
Pagina 87
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-36 TROUBLESHOOTING & REP AIR F-36 WIRE-MA TIC 255 PROCEDURE 1. Disconnect main input power to the machine. 2. Remove the Case T op and Side Panels. 3. Perform the Capacitor[...]
-
Pagina 88
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-37 TROUBLESHOOTING & REP AIR F-37 WIRE-MA TIC 255 MA TERIALS NEEDED 3/4" Open end wrench. 1/2" Socket wrench with extension. Phillips head screwdriver . F AN MOTO[...]
-
Pagina 89
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-38 TROUBLESHOOTING & REP AIR F-38 WIRE-MA TIC 255 PROCEDURE See Figure F .16 for fan motor and fan removal components. FIGURE F .16 - Fan Motor and Fan Removal Components 1[...]
-
Pagina 90
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-39 TROUBLESHOOTING & REP AIR F-39 WIRE-MA TIC 255 F AN MOTOR AND F AN REMOV AL AND REPLACEMENT (CONTINUED) 7. Remove the fan motor . a. Loosen and remove the two screws fro[...]
-
Pagina 91
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-40 TROUBLESHOOTING & REP AIR F-40 WIRE-MA TIC 255 INPUT IDLE AMPS AND W A TTS WIRE SPEED RANGE OPEN CIRCUIT VOL T AGE RETEST AFTER REP AIR Maximum Idle W atts Maximum Idle [...]
-
Pagina 92
NOTES WIRE-MA TIC 255 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 93
T ABLE OF CONTENTS - ELECTRICAL DIAGRAMS SECTION - WIRE-MA TIC 255 Electrical Diagram Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section G Wiring Diagram (208/230) Code 10166 . . . . . . . . . . . . . . . . . . . . . . . . . G-2 Wiring Diagram (230/460/575) Code 10167 . . . . . . . . . . . . . . . . . . . . . . G-3 Co[...]
-
Pagina 94
NOTES WIRE-MA TIC 255 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 95
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-2 WIRE-MA TIC 255 Wiring Diagram (208/230) Code 10166 GENERAL INFORMATION COLOR CODE: B - BLACK W - WHITE THERMOSTAT 202 204A 203 204 208 G1 X2 X1 G2 209 SC[...]
-
Pagina 96
G-3 ELECTRICAL DIAGRAMS WIRE-MA TIC 255 Wiring Diagram (230/460/575) Code 10167 GENERAL INFORMATION COLOR CODE: B - BLACK W - WHITE THERMOSTAT 202 204A 203 204 208 G1 X2 X1 G2 209 SCR 1 250V 470A SCR HEATSINK ASBLY SCR 2 250V 470A C1 C2 C3 C4 ++++ POWER TRANSFORMER L1 L2 GND TO SINGLE PHASE SUPPLY LINE TO GROUND PER CODE 207 206 OUTPUT CHOKE NOTES [...]
-
Pagina 97
G-4 ELECTRICAL DIAGRAMS WIRE-MA TIC 255 Control PC Board (G2803) Schematic G-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubl[...]
-
Pagina 98
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC G-5 ELECTRICAL DIAGRAMS WIRE-MA TIC 255 Control PC Board (G2803) Layout G-5 NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troublesh[...]