Louisville Tin and Stove DVCF558B-R manuale d’uso
- Visualizza on-line o scarica il manuale
- 22 pagine
- 0.28 mb
Vai alla pagina of
Manuali d’uso simili
-
Furnace
Louisville Tin and Stove 90N50A
19 pagine 0.26 mb -
Furnace
Louisville Tin and Stove W501F W252F
20 pagine 0.23 mb -
Furnace
Louisville Tin and Stove W251F
20 pagine 0.23 mb -
Furnace
Louisville Tin and Stove DVCF654B-R
22 pagine 0.28 mb -
Furnace
Louisville Tin and Stove 000 BTU
2 pagine 0.24 mb -
Furnace
Louisville Tin and Stove DVCF404B-R
22 pagine 0.28 mb -
Furnace
Louisville Tin and Stove HEDV253A
2 pagine 0.18 mb -
Furnace
Louisville Tin and Stove HEDV403
22 pagine 0.25 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Louisville Tin and Stove DVCF558B-R. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Louisville Tin and Stove DVCF558B-R o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Louisville Tin and Stove DVCF558B-R descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Louisville Tin and Stove DVCF558B-R dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Louisville Tin and Stove DVCF558B-R
- nome del fabbricante e anno di fabbricazione Louisville Tin and Stove DVCF558B-R
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Louisville Tin and Stove DVCF558B-R
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Louisville Tin and Stove DVCF558B-R non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Louisville Tin and Stove DVCF558B-R e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Louisville Tin and Stove in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Louisville Tin and Stove DVCF558B-R, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Louisville Tin and Stove DVCF558B-R, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Louisville Tin and Stove DVCF558B-R. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
DIRECT VENT COUNTERFLOW W ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 72900 - REV . 12/03 MODEL NUMBERS NA T . GAS DVCF407B-R DVCF557B-R L.P . GAS DVCF408B-R DVCF558B-R W ARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. MODEL[...]
-
Pagina 2
CONTENTS Introduction………………………………. 2 Specifications and Dimensions…………… 2 Safety Rules………………………………. 3 Clearances………………………………… 4, 5 Location…………………………………… 6 Installation………………………………… 6 Operation………………?[...]
-
Pagina 3
SAFETY RULES 1. Follow all applicable local codes and ordinances. If there are none, follow the latest edition of the National Fuel Gas Code, ANSI.Z223.1. A copy may be obtained from American Gas Association, 1515 W ilson Blvd., Arlington, V irginia 22209, or the National Fire Protection Association, Batterymarch Park, Quincy , MA. 02269. In Canada[...]
-
Pagina 4
REFER ENCE LE TTER TO DRAWI NG CANADIAN I NSTALLA T A = C l earance abo ve grade, ve randa, porch, d eck, or b alcony 12 In ches (30 cm) B = C l earanc e to windo w or do or that may be open ed 12 In ches (30 cm) C = C learanc e to perma nent l y closed wi ndow 12 In ches (30 cm) D = Verti cal cl earance to ventil ated sof fi t l ocated a bove th e[...]
-
Pagina 5
CLEARANCES 1 . The minimum clearance to a side wall is 4”. (See Fig. 1). NOTE: The unit may be recessed and rest directly against side studs and the inside surface of the rear wall. 2. The minimum clearance to the ceiling is 4”. (See Figure 1). 3. The minimum clearance to the floor is 0”. (See Figure 1). 4. The minimum clearance from the side[...]
-
Pagina 6
LOCA TIONS 1. This furnace must be installed on an outside wall and vented to the outside. If possible, this wall should be on the side of the house that receives the least amount of wind since strong gusting winds could cause pilot outage. 2. For most ef ficient performance, locate furnace as centrally as possible in the area to be heated. 3. The [...]
-
Pagina 7
LOCA TE VENT OPENING After the location of the heater has been determined, the opening for the vent pipe should be cut. If the heater is to be recessed, cut out opening for heater between studs on the interior wall and cut out the floor plate between the studs, so heater will set flat on floor as all dimensions are given from a finished floor . The[...]
-
Pagina 8
LIGHTING INSTRUCTIONS: DVCF403B, DVCF404B, DVCF653B, DVCF654B FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injur y or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in[...]
-
Pagina 9
LIGHTING INSTRUCTIONS: DVCF407B, DVCF408B, DVCF557B, DVCF558B FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try[...]
-
Pagina 10
PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or flame sensor (see Figure 7). The pilot is unregulated so it will be operating at inlet line pressure (Max. 7” w .c. for Natural Gas and 1 1” w .c. for Propane). T o decrease the pilot fla[...]
-
Pagina 11
DVCF403B, DVCF404B ST ANDING PILOT DVCF653B, DVCF654B THERMOST A T POWER CORD MOTOR GREEN WHITE BLACK BROWN BLACK TRANSFORMER BLUE BLACK LIMIT SWITCH FAN SWITCH AUXILIAR Y LIMIT SWITCH GAS V AL VE BLACK BLACK BLACK BLACK BLACK GREEN WHITE WHITE DVCF403, DVCF404 PICTORIAL SCHEMA TIC MODEL NO. AMPS DVCF403 1.95 DVCF404 1.95 MOT OR THERMOST A T POWER [...]
-
Pagina 12
DVCF407B, DVCF408B I.I.D. DVCF557B, DVCF558B THERMOST A T POWER CORD MOT OR GREEN GREEN WHITE WHITE BLACK BROWN BLACK WHITE BLACK BLUE BLACK TRANSFORMER LIMIT SWITCH F AN SWITCH PILOT AUXILIAR Y LIMIT SWITCH BLACK GAS V AL VE P C M TH PV SENSE MV MV/PV TR IGN SP715-NA T . OR SP735-L.P . SP715-NA T . OR SP735-L.P . TH PV SENSE MV MV/PV TR IGN THERMO[...]
-
Pagina 13
CAUTION: Label all wires prior to disconnection when servicing contr ols. Wiring errors can cause improper and danger ous operation. V erify proper operation after servicing. TERMINAL BLOCK WIRING DIAGRAM Fan/Limit Switch (Brown) Power Cord (Black) Transformer (Black) Selector Switch (Red) Motor (Red) Power Cord (Green) T erminal Board Ground (Gree[...]
-
Pagina 14
OPTIONAL SIDE DISCHARGE KITS SIDE DISCHARGE ON CASING 1. Use Optional Kit No. 306SR-A. 2. Cut out and remove embossed area on casing side. 3. Remove knockout from inner liner . 4 . Place 1-1/2” boot from kit through opening, matching flanges of boot to knockout on inner liner . 5. Mark screw holes and remove boot. 6. Drill holes with a 1/8” dri[...]
-
Pagina 15
14-PEK KIT INSTRUCTIONS (14’ PLUG EXTENSION KIT) FOR NON-RECESSED INST ALLA TIONS ONL Y 90 Degree Outside Corner 3 FT . SECTION W ALL 3 FT . SECTION BOTTOM SECTION 1 2 3 4 UNITS WITH TERMINAL BOARD STEP # 1. Turn heater of f following Section 3 in “Lighting Instructions” and allow to cool. 2. Turn of f all electricity to heater . 3. Remove to[...]
-
Pagina 16
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of valve. 1. Replace valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 feet. 3. See orifice chart, page 10. Y ellow burner flame 1. Clogged burner ports. 1. Remove main burner and[...]
-
Pagina 17
Burner won’t turn on 1. Gas valve not turned on. 1. T urn gas valve to “on” position. 2. No voltage to valve. 2. Check for 24 V olts to valve from transformer . 3. Defective thermostat. 3. Check wall thermostat. 4. No 1 15 V . Line voltage. 4. Provide line voltage. 5. Gas valve defective. 5. Replace gas valve. 6. Manual reset switch not engag[...]
-
Pagina 18
DIRECT VENT COUNTERFLOW W ALL FURNACE SP ARK IGNITER - I.I.D. THERMOST A T VENT ASSEMLBY Prices and specifications subject to change without notice. All prices are F .O.B. factory . BURNER ASSEMBL Y DVCF40B-R, DVCF55B-R, DVCF65B-R SERIES Page 18 55 14 15 54 12 25b 28b 28 25 34 58 13 13b 41 53 57 56 31 59 60 32 33 43 23 40 37 49 48 47 46 45 39 1g 51[...]
-
Pagina 19
NA T . DVCF403B-R DVCF407B-R DVCF557B-R DVCF653B-R MODEL NUMBER L . P . DVCF404B-R DVCF408B-R DVCF558B-R DVCF654B-R R EF . P AR T LIST P AR T LIST P A R T LIST P AR T LIST P ART DESCRIPTION NO. NO. PRICE N O . PRICE N O . P R IC E N O . PRICE Casing Side, Right 1a 34065 $56.10 34065 $56.10 34560 $61.30 34560 $61.30 Casing Side, Left 1b 34055 $56.10[...]
-
Pagina 20
NA T . DVCF403B-R DVCF407B-R DVCF557B-R DVCF653B-R MODEL NUMBER L. P . DVCF404B-R DVCF408B -R DVCF558B-R DVCF654B-R RE F . P ART LIST P ART LIST P A RT LIST P ART LIST P ART DESCRIPTION N O . N O . PRICE N O . PRICE N O . PRICE N O . PRICE Power Cord N/A 78213 $4.70 78213 $4.70 78213 $4.70 78213 $4.70 Sight Glass Assembly 31 43252 $6.50 43252 $6.50[...]
-
Pagina 21
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G[...]
-
Pagina 22
The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product. AS OUTLINED IN OUR INSTRUCTIONS, ANY W ARRANTY CONSIDERA TIONS ARE CONTINGE[...]