Vai alla pagina of
Manuali d’uso simili
-
Portable Speaker
Meyer Sound Control Electronics Unit MPS-3
2 pagine 0.04 mb -
Portable Speaker
Meyer Sound Stella-4
1 pagine 0.18 mb -
Portable Speaker
Meyer Sound HD-2
2 pagine 0.04 mb -
Portable Speaker
Meyer Sound MSL-5
4 pagine 0.14 mb -
Portable Speaker
Meyer Sound MSL-6
14 pagine 0.33 mb -
Portable Speaker
Meyer Sound Control Electronics Unit S-1
4 pagine 0.05 mb -
Portable Speaker
Meyer Sound M2D
40 pagine 2.49 mb -
Portable Speaker
Meyer Sound M1DTM
2 pagine 0.2 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Meyer Sound MSL-6. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Meyer Sound MSL-6 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Meyer Sound MSL-6 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Meyer Sound MSL-6 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Meyer Sound MSL-6
- nome del fabbricante e anno di fabbricazione Meyer Sound MSL-6
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Meyer Sound MSL-6
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Meyer Sound MSL-6 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Meyer Sound MSL-6 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Meyer Sound in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Meyer Sound MSL-6, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Meyer Sound MSL-6, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Meyer Sound MSL-6. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Operating Instructions MS L - 6 Copyright © 1997 Meyer Sound Laboratories, Inc. All rights reserved Part # 05.053.026.01 Rev A Self-Powered Loudspeaker System[...]
-
Pagina 2
2 Made by Meyer Sound, Berkeley, CA, USA European Office: Meyer Sound Germany GmbH Carl Zeiss Strasse 13 56751 Polch, Germany U U L L C C U U L L ®® LISTED 3K59 COMMERCIAL AUDIO SYSTEM According to ISO/IEC Guide and EN 45014 Declaration of Conformity The product herewith complies with the require- ments of the Low Voltage Directive 73/23/EEC and [...]
-
Pagina 3
3 Introduction The MSL-6, Meyer Sound’s largest self-power ed speaker , is ideally suited for large-scale vocal public addr ess applications as a stand-alone system, and for musical sound reinfor cement in combination with Meyer self- powered subwoofers and/or the DS-2P mid-bass speaker . The MSL-6 features a 2 5 ° vertical coverage angle, permi[...]
-
Pagina 4
4 If the voltage decreases below the lower bound of either operating range ( brown-out ), the supply uses stor ed energy to continue functioning briefly . The unit turns of f if the voltage does not increase above the thr eshold before the storage cir cuits are depleted. The time that th e MSL-6 continues to operate during brown-out depends on how [...]
-
Pagina 5
5 Safety Issues Pay close attention to these important electrical and safety issues. Use a power cord adapter to drive the MSL-6 from a standard 3-prong outlet (NEMA 5-15R;125 V max). earth ground chassis ground The MSL-6 requires a grounded outlet. Always use a grounding adapter when connecting to ungrounded outlets. Do not use a ground-lifting ad[...]
-
Pagina 6
6 Amplification and Protection Circuitry The MSL-6 i s powered by the Meyer MP-4, a four - channel 2480 W amplifier (620 W/ch) utilizing comple- mentary power MOSFET output stages (class AB/H). The following sections discuss the MP-4’s limiting circuitry and four-fan cooling system. The T ruPower™ Limiting System Conventional limiters assume th[...]
-
Pagina 7
7 Fans and Cooling System The MSL-6 uses a forced-air cooling system with four fans to prevent the amplifiers fr om overheating. The fans draw air in through ducts on the fr ont of the cabinet, over the heatsinks, and out the rear of the cabinet. Since dust does not accumulate in the amplifier circuitry , its life-span is increased significantly . [...]
-
Pagina 8
8 Measurement and System Integration Measurement and corr ection tools are requir ed to assemble a complete sound system, particularly when the venue requir es precise array design, delay systems, or compensation for significant reverberation. W e recommend using the Meyer SIM® System II Sound Analyzer and CP-10 Parametric Equalizer to • assist [...]
-
Pagina 9
9 650-P Subwoofers MSL-4 Down-fills Input Mid-Hi Output Sub Output Input Output LD-1A Delay CP-10 EQ CH 1 CH 3 Input Output CH 5 CP-10 EQ Ch A A B Ch B MSL-6 Upper MSL-6 Lower CH 5 controls the MSL-4 down-fill system. Since the main system is more powerful than the down-fill system to project farther into the venue, the main system is audible in th[...]
-
Pagina 10
10 Driver T roubleshooting The Remote Monitoring System (RMS) is the best method to query the status of the drivers in a system before and during the performance. RMS monitors peak power , peak voltage, and average voltage (VU) for each amplifier channel, allowing immediate detection and muting for drivers with open or shorted voice coils, with min[...]
-
Pagina 11
11 Use the following test to verify polarity between high and low frequency drivers: 1. Place a monitoring microphone 5 ft from the grill frame, 24” below the top of the cabinet, at the mid- point between low drivers (center-line of cabinet). 2. Connect a signal source to the loudspeaker and note the frequency response. The polarity is correct if[...]
-
Pagina 12
12 Physical Construction Upper & Lower Braces 3 ⁄16 " Steel, ASTM A36 3 ⁄8 "-16 Reinforcement Rods, B7 Alloy Steel Fluid-Cooled High Frequency Driver, 4-inch Diaphragm (2-inch Throat) Fluid-Cooled Back- Vented 12-inch Cone Low-Frequency Driver 3 ⁄8 " Plywood Top & Bottom 3 ⁄16 " inch ASTM A36 Steel Support Channe[...]
-
Pagina 13
13 • To reduce the risk of electric shock, disconnect the loud- speaker from the AC mains before installing audio cable. Reconnect the power cord only after making all signal connections. • Connect the loudspeaker to a two-pole, three wire grounding mains receptacle. The receptacle must be connected to a fuse or circuit breaker. Connection to a[...]
-
Pagina 14
14 Meyer Sound Laboratories, Inc. 2832 San Pablo Avenue Berkeley, California 94702 Telephone: 510 - 486 - 1166 FAX: 510 - 486 - 8356 E-mail: techsupport@meyersound.com http://www.meyersound.com Meyer Sound Germany Gmbh Carl Zeiss Strasse 13 56751 Polch, Germany Telephone: 49.2654.9600.58 FAX: 49.2654.9600.59 Contact Information ATENCIÓN : ACCESO I[...]