Mitsubishi Electronics PL30FK21 manuale d’uso
- Visualizza on-line o scarica il manuale
- 67 pagine
- 1.73 mb
Vai alla pagina of
Manuali d’uso simili
-
Air Conditioner
Mitsubishi Electronics PCA-A.KA4
36 pagine 1.18 mb -
Air Conditioner
Mitsubishi Electronics 36
12 pagine 0.86 mb -
Air Conditioner
Mitsubishi Electronics MSZ-A12NA
29 pagine 1.74 mb -
Air Conditioner
Mitsubishi Electronics PEA-RP170
12 pagine 0.2 mb -
Air Conditioner
Mitsubishi Electronics PUY-A12NHA2
120 pagine 10.58 mb -
Air Conditioner
Mitsubishi Electronics MXZ-2GB20NA
86 pagine 6.3 mb -
Air Conditioner
Mitsubishi Electronics PKFY-P.NKMU-E
56 pagine 9.09 mb -
Air Conditioner
Mitsubishi Electronics AG-150A
16 pagine 0.44 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Mitsubishi Electronics PL30FK21. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Mitsubishi Electronics PL30FK21 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Mitsubishi Electronics PL30FK21 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Mitsubishi Electronics PL30FK21 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Mitsubishi Electronics PL30FK21
- nome del fabbricante e anno di fabbricazione Mitsubishi Electronics PL30FK21
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Mitsubishi Electronics PL30FK21
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Mitsubishi Electronics PL30FK21 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Mitsubishi Electronics PL30FK21 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Mitsubishi Electronics in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Mitsubishi Electronics PL30FK21, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Mitsubishi Electronics PL30FK21, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Mitsubishi Electronics PL30FK21. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
OC194-1 CONTENTS 1. TECHNICAL CHANGE ··················································································OC194- 2 2. FEA TURES ·······························································?[...]
-
Pagina 2
OC194-2 1 TECHNICAL CHANGE Change points Optional par ts Program timer FK2 Switch f or temperature unit Switch f or louvers — OFF Control change of the normal and twin Change of the unit No .1 and No.2 — — P AC–SK65PT Canceled Canceled Addition of "Mode selector" ON Addition of "Not yet used" Addition of "LOSSNA Y i[...]
-
Pagina 3
OC194-3 FEA TURES 2 1. SP A CE-SA VING CENTRALL Y LOCA TED CEILING RECESSED INST ALLA TION 2. 4-W A Y AIR FLO W SYSTEM This series allows you to select from 2, 3, and 4 w a y air flow directions according to y our requirement. As a result, y ou get superb fle xibility in choosing a configuration that giv es you maximum cooling efficiency in a neat [...]
-
Pagina 4
OC194-4 3 P AR T NAMES AND FUNCTIONS Remote controller operation b uttons TIMER OFF TIMER CHECK SET TEMP . DRY COOL FAN CLOCK AUTO A UTO STAR T STOP MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FIL TER CHECK TEST RUN AIR SWEEP SET TEMP . TIMER SET F FAN SPEED SWING REMOTE CONTROLLER P AR-JC240KUS AUTO RETURN FIL TER button This resets the [...]
-
Pagina 5
OC194-5 TIMER OFF TIMER CHECK SET TEMP . DRY COOL FAN CLOCK AUTO A UTO STAR T STOP MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FIL TER CHECK TEST RUN AIR SWEEP SET TEMP . TIMER SET F FAN SPEED SWING REMOTE CONTROLLER P AR-JC240KUS AUTO RETURN Operation lamp This lamp lights during operation, goes off when the unit stops and flashes when a[...]
-
Pagina 6
OC194-6 4 SPECIFICA TIONS Capacity P ower Consumption EER SEER INDOOR UNIT MODELS External finish P ower supply Max.fuse size (time dela y) Min.ampacity F an motor Airflow Hi-Lo Moisture remov al Sound lev el Hi-Lo Cond. drain pipe O.D . Dimensions Weight External finish Dimensions Weight OUTDOOR UNIT MODELS External finish Sound lev el P ower supp[...]
-
Pagina 7
OC194-7 Capacity P ower Consumption EER SEER INDOOR UNIT MODELS External finish P ower supply Max.fuse size (time dela y) Min.ampacity F an motor Airflow Hi-Lo Moisture remov al Sound lev el Hi-Lo Cond. drain pipe O.D . Dimensions Weight External finish Dimensions Weight OUTDOOR UNIT MODELS External finish Sound lev el P ower supply Max. fuse size [...]
-
Pagina 8
OC194-8 5 DA T A MODELS : PL12FK 1 , PL18/24/30FK2 1 , PL36FK3 1 , PL42FK2 1 1. PERFORMANCE D A T A 1) COOLING CAP ACITY Models Indoor air Outdoor intake air DB temperature ( °F ) PL12FK 1 71 67 63 71 67 63 71 67 63 71 67 63 71 67 63 71 67 63 TC 14.3 13.2 12.1 21.2 19.8 18.5 27.4 25.6 23.8 35..8 33.2 30.9 41.7 38.9 36.4 49.6 46.1 42.8 SHC 7.1 8.4 [...]
-
Pagina 9
OC194-9 2. PERFORMANCE CUR VE NO TES : A point on the curve shows the ref erence point. PL12FK 1 COOLING CAP A CITY PL18FK2 1 COOLING CAP A CITY T otal power consumption (kW) T otal capacity (x10 3 Btu/h) Outdoor intake air DB temperature ( F) 24 21 12 18 15 2.5 2.0 1.5 1.0 63 67 71 63 67 71 SHF=0.76 0 32 35 45 55 65 (67) 75 85 95 105 115 Indoor in[...]
-
Pagina 10
OC194-10 NO TES : A point on the curve shows the ref erence point. PL24FK2 1 COOLING CAP A CITY PL30FK2 1 COOLING CAP A CITY T otal power consumption (kW) T otal capacity (x10 3 Btu/h) Outdoor intake air DB temperature ( F) 36 30 42 24 4.0 3.5 3.0 2.5 63 67 71 63 67 71 SHF=0.76 23 32 35 45 55 65 (67) 75 85 95 105 115 Indoor intake air WB temperatur[...]
-
Pagina 11
OC194-11 <PL18FK2 1 > COOLING MODE 3. CONDENSING PRESSURE AND SUCTION PRESSURE Data is based on the condition of indoor humidity 50%. Air flow should be set at HI. A point on the cur ve sho ws the reference point. <PL12FK 1 > 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190 180 170 160 150 (psi.G) Condensing pressure [...]
-
Pagina 12
OC194-12 Data is based on the condition of indoor humidity 50%. Air flow should be set at HI. A point on the cur ve sho ws the reference point. <PL24FK2 1 > <PL30FK2 1 > COOLING MODE 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190 180 170 160 150 (psi.G) Condensing pressure 30 40 50 60 70 80 90 100 110 Outdoor ambien[...]
-
Pagina 13
OC194-13 Data is based on the condition of indoor humidity 50%. Air flow should be set at HI. A point on the cur ve sho ws the reference point. <PL36FK3 1 > <PL42FK2 1 > COOLING MODE 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190 180 170 160 150 (psi.G) Condensing pressure 30 40 50 60 70 80 90 100 110 Outdoor ambien[...]
-
Pagina 14
OC194-14 4. ST AND ARD OPERA TION D A T A 750 750 750 750 760 760 840 840 Capacity SHF Input INDOOR UNIT MODEL Power supply (V, phase, Hz) Input Fan current OUTDOOR UNIT MODEL Power supply (V, phase, Hz) Input Comp. current Fan current Condensing pressure Suction pressure Discharge temp. Condensing temp. Suction temp. Ref. pipe length Refrigerant c[...]
-
Pagina 15
OC194-15 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPRO XIMA TE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 OCT A VE BAND SOUND PRESSURE LEVEL, dB re 0.002 MICR O BAR BAND CENTER FREQUENCIES, Hz PL12FK 1 Hi Lo 43 SPL(dB) 35 LINE NO TCH 7. NOISE CRITERION CUR VES Airflow Air speed Coverage range[...]
-
Pagina 16
OC194-16 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPRO XIMA TE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 OCT A VE BAND SOUND PRESSURE LEVEL, dB re 0.002 MICR O BAR BAND CENTER FREQUENCIES, Hz PL24FK2 1 Hi NO TCH Lo 47 SPL(dB) 39 LINE 8. NOISE CRITERION CUR VES 90 80 70 60 50 40 30 20 10 63 1[...]
-
Pagina 17
OC194-17 OUTLINES AND DIMENSIONS 6 Unit : inch 1. INDOOR UNIT PL12FK 1 / 18/24FK2 1[...]
-
Pagina 18
OC194-18 Unit : inch PL30FK2 1 / 36FK3 1 / 42FK2 1[...]
-
Pagina 19
OC194-19 Unit : inch 2.Remote controller FILTER CHECK MODE TEST RUN TIMER OFF TIMER CHECK SET TEMP . CLOCK AUTO A UTO STAR T STOP SWING FAN SPEED 5-1/8 4-3/4 3/4 3/32 23/32 AUTO RETURN FAN Indoor coil thermistor RT2 Distributor Refrigerant pipe (option) { 3/8" (with heat insulator) Refrigerant pipe (option) { 5/8" (with heat insulator) St[...]
-
Pagina 20
OC194-20 WIRING DIA GRAM 8 MODELS PL12FK 1 PL18FK2 1 PL24FK2 1 WIRING DIA GRAM SYMBOL C1 CN1<R.B> CN2<R.B> CN51<I.B> CN2L<I.B> DP DS F1<I.B> F2 H2 I.B LS MF1 MV R.B NAME F an motor capacitor Connector <program timer> Connector <remote switch> Connector < centrally control> Connector <lossnay> Dr[...]
-
Pagina 21
OC194-21 MODELS PL30FK2 1 PL36FK3 1 PL42FK2 1 WIRING DIA GRAM NO TES: 1.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 2.Indoor and outdoor connecting wires are made with polarities,make wiring matching terminals. 3.Symbols used in wiring diagram abov e are, :T er minal block, , :c[...]
-
Pagina 22
OC194-22 9 OPERA TION FLO W -CHART START Power circuit breaker Check SW ON twice Operation SW ON “OFF” timer “ON” timer STOP Set time complete Set time complete 1 NO NO NO NO NO NO NO NO NO YES YES YES YES YES YES YES YES YES YES w 1 w 2 w 3 w 4 w 5 PROTECTION DEVICE SELF HOLD RELEASE Remote controller indicator lamp OFF Trouble STOP Remote[...]
-
Pagina 23
OC194-23 COOL operation Initial COOLING NO NO NO NO NO YES YES YES YES YES YES NO YES YES YES YES YES YES YES YES YES YES YES NO NO NO NO YES NO NO NO NO NO NO NO NO NO w 8 w 9 Vane initial setting Vane 55 deg downward angle 70 deg downward angle Fan speed LOW Downward discharge 1 hour Vane setting notch Vane horizontal airflow Compressor thermosta[...]
-
Pagina 24
OC194-24 w 8—9 Ref er to page OC194-23. w 12 When room temperature is 64°F or below , the compressor cannot operate. When room temperature rises ov er 64°F the compressor star ts after a 3-minute time dela y . w 13 Compressor ON time is decided by room temper ature. Refer to page OC194-29. w 14 In dry operation, compressor ON makes the f an spe[...]
-
Pagina 25
OC194-25 MICR OPROCESSOR CONTR OL 10 ● Compressor and outdoor f an : ON- OFF 1.OUTLINE OF MICROPR OCESSOR CONTROL ● OFF-ON s witching. ● COOL/DR Y -F AN selector s witching. ● Thermostat setting. ● TIMER mode selector-s witching and Timer setting. ● HIGH-LO W fan speed s witching. ● A UTO V ane selector (AIR DISCHARGE) s witching. ●[...]
-
Pagina 26
OC194-26 2. INDOOR UNIT CONTROL 2-1 COOL operation (1) Compressor control 1 3-minute time dela y T o prev ent overload, the compressor will not star t within 3 minutes after stop . 2 The compressor runs when room temperature is higher than set temperature. The compressor stops when room temperature is equal to or low er than the set temperature. Th[...]
-
Pagina 27
OC194-27 5 Coil frost protection When indoor coil temperature becomes 5°F or below ,coil frost protection will proceed as follo ws. <Start condition> After the compressor has been continuously operated f or 3 minutes or more,and the indoor coil temperature has been 5°F or below f or 3 minutes,the coil frost protection will star t. <Coil [...]
-
Pagina 28
OC194-28 (4) Detecting abnormalities in the outdoor unit After the compressor has been continuously operated f or 3 minutes, if the diff erence between the indoor coil temperature and room temperature is out of RANGE C f or 1 minute, the indoor fan speed will turn to LO W . Five min utes later , if the dif- f erence is still out of RANGE C,the outd[...]
-
Pagina 29
OC194-29 <DR Y operation time chart> Minimum 3 minutes w 1 ON Thermostat Indoor fan Auto vane Drain pump Compressor ON ON DRY MODE DRY MODE ON OFF OFF ON OFF 3 minutes OFF OFF Operation starts by POWER button ON. Operation stops by POWER button OFF. Room temperature becomes equal to set temperature. Room temperature rises above set temperatur[...]
-
Pagina 30
OC194-30 4 The compressor will not star t when the room temperature is 64°F or below . The compressor star ts inter mittent operation when the power is turned ON with room temperature abov e 64°F . The com- pressor ON/OFF time depends on the thermostat ON/OFF and the following room temper atures.After 3-minute compres- sor operation, ● If the r[...]
-
Pagina 31
OC194-31 <How to operate> T o change the air flow direction, press AIR DISCHARGE button. 1 20° 2 45° 3 60° 45 70° SWING (1) COOL/DR Y operation At the star t-up of COOL or DR Y operation, the airflo w direction in automatically set to 20°. After , it can be changed to another direction with AIR DISCHARGE button on the remote controller .[...]
-
Pagina 32
OC194-32 <Timer function> A UTO ST OP ··········The air conditioner stops after the set time lapses. A UTO ST AR T ········The air conditioner star ts after the set time lapses. A UTO OFF ············Timer is not active. <How to operate> 1. Press POWER ON/OFF button. 2. Press “TIMER ON/OFF” button to se[...]
-
Pagina 33
OC194-33 (1) Indoor coil temperature code During the test r un, the indoor coil temperature code from 1 to 15 is displa yed on the remote controller instead of room temperature. The code should f all with the lapse of time in nor mal COOL operation, and should rise in nor mal HEA T operation. (2) T rouble during test run ● If the unit malfunction[...]
-
Pagina 34
OC194-34 3 DIP SWITCH FUNCTIONS Each figure shows the initial setting b y f actor y . 3-1 On remote controller boar d (1) SW17(Address selector) SW17-1 ~ 6) Switch f or address setting SW17-7) When two remote controllers are used, this switch sets the controller function. OFF : The remote controller is set as a main controller . ON : The remote con[...]
-
Pagina 35
OC194-35 SW1-6) Switch f or set temperature adjustment in heating mode This is not av ailable for series PL. SW1-7) Switch f or fan speed during ther mostat OFF in heating mode This is not av ailable for series PL. SW1-8) Switch f or fan motor operation in heating mode This is not av ailable for series PL. SW1-9) Switch f or outdoor unit abnor mali[...]
-
Pagina 36
OC194-36 11 TR OUBLESHOO TING The displa y “CENTRALL Y CONTROLLED” on remote controller does not disap- pear . 1) Wrong address setting of remote con- troller/indoor controller board. 2) Timer adapter is connected to the remote controller . 3) Signal transmission error between indoor unit and remote controller . 1) Check the address setting of [...]
-
Pagina 37
(2) When one remote controller controls seve ral units in the group con- trol, the LCD shows the unit address and chec k code of the first mal- functioning unit. (3) T o cancel the check mode , press the ON/OFF button. In remote ON/OFF control, press the remote ON/OFF s witch. In centralize control, turn OFF the ON/OFF button of centralize controll[...]
-
Pagina 38
OC194-38 1) Check the indoor/outdoor connecting wire . 2) Change the connection of electric wir ing. 3) Check the protection de vice. 4) Measure the resistance of the outdoor coil ther- mistor . If the resistance is normal, replace the outdoor controller board. Check code Diagnosis of malfunction Cause Check points E0 Signal transmitting/receiving [...]
-
Pagina 39
OC194-39 Wrong wiring Thermostat Phenomenon Outdoor Indoor 1 2 3 1 2 3 OFF Operation stops. ON 4-W ay v alve is turned to ON. 9 minutes later , the check code “P8” appears on the remote controller displa y . Outdoor Indoor 1 2 3 1 2 3 OFF The outdoor unit stops. ON Operation stops. 9 minutes later , the check code “P8” appears on the remote[...]
-
Pagina 40
OC194-40 V anes do not work. V ane motor does not work. Connector is poorly connected. V ane motor is poorly assembled. Indoor controller board is damaged. Unit stops after 5 to 20 seconds operation Protection function is working. Air discharge displa y is OFF and AIR DIS- CHARGE button does not operate. Indoor controller board deems the auto vanes[...]
-
Pagina 41
OC194-41 4. How to chec k the par ts PL12FK 1 /18FK2 1 /24FK2 1 /30FK2 1 /36FK3 1 /42FK2 1 P ar ts name Check points Disconnect the connector then measure the resistance using a tester . (Surrounding temperature 50 - F~86 - F) Measure the resistance between the terminals using a tester . (Surrounding temperature 68 - F~86 - F) Measure the resistanc[...]
-
Pagina 42
OC194-42 0 10 20 30 40 50 -4 14 32 50 68 86 104 122 < Thermistor for lower temperature > T emperature ( - F) Resistance (K " ) <Thermistor Character istic graph> Room temperature thermistor(TH1) Liquid pipe thermistor(TH2) Ther mistor R 0 =15k ' ± 3% Fix ed number of B=3480k ' ± 2% Rt=15e xp { 3480( ) } 32°F 15k '[...]
-
Pagina 43
OC194-43 4-W A Y AIR FLO W SYSTEM 12 Using this grill enables to select the air discharge direction. The air flow can also be regulated b y adjusting the widths of each discharge outlet. Choose the adequate method according to the conditions in the room where the panel is to be installed. W F or 2-direction discharge, the widths of the outlets must[...]
-
Pagina 44
OC194-44 Opening measurements f or PLH30/36/42FK 1 are within ( ). ● ● Regular ceiling height When ceiling is of regular height (F or example 8.2ft) set each out- let at a standard width (11-13/16). ● ● Relativel y high ceiling Set the outlets during installation. The outlet width can be adjusted in the range of 7-7/8 to 11-13/16 using the [...]
-
Pagina 45
OC194-45 Selecting arrangement of discharge outlet and adjusting the width f or PL12FK 1 / 18/24FK2 1 . Constrained Conditions When Selecting Discharge Outlet Width. (PL18/24FK2 1 ) T otal width of four outlets must e xceeds 31-1/2. Unit : inch (1) When the outlet A is close to a window, widen A and narrow C to raise the cooling power of A. e.g. 1 [...]
-
Pagina 46
OC194-46 Selecting arrangement of discharge outlet and adjusting the width f or PL30FK2 1 / 36FK3 1 / 42FK2 1 . Constrained Conditions When Selecting Discharge Outlet Width. (PL30/36/42FK) T otal width of four outlets must e xceeds 55-1/8. Unit : inch When the unit is installed near a window, the longer outlet (B or D) must be in direction of the w[...]
-
Pagina 47
OC194-47 FRESH AIR INT AKE (Installation at site) 1. Location for installing fresh air intake 2. Air flow & static pressure conditions f or fresh air intake Detail drawing of fresh air intak e Be sure to use a duct f an (booster fan) when applying fresh air intake . As f or sequential operation with the duct f an, see Item 3. 3. Sequential oper[...]
-
Pagina 48
OC194-48 BRANCH DUCT (installation at site) 1. Branch Duct Installation Pr ocedure 2. Branch Duct Installation T o discharge air from a branch duct, install it during the initial installation. Install branch duct at site b y follo wing procedure (1) Remo ve insulation along the brok en-lines on unit surf ace at the back-side of the indoor unit. Kno[...]
-
Pagina 49
OC194-49 3 direction discharge 4 direction discharge () 25-9/16 O O 2 directions 11-13/16 O O 2 directions 3 direction discharge () 35-7/16 O O 1 directions 11-13/16 O O 2 directions Branch duct (3-15/16) (11-13/16) (27-9/16) (35-7/16) Static pressure [in.W.G O 10 –2 ] 0 50 100 150 200 250 300 350 400 450 500 550 20 16 12 8 4 Air capacity [CFM] S[...]
-
Pagina 50
OC194-50 13 SYSTEM CONTR OL Unit Remote control display board Remote controller Unit Unit T wo remote controllers can be used to control either one unit or a group of units. Units can then be controlled from a distance or at close range. Units operate according to the latest command from either remote controller . 1 Group control with a single remo[...]
-
Pagina 51
OC194-51 2. GROUP CONTR OL BY A SINGLE REMO TE CONTROLLER A maximum of 50 units can be star ted in order according to the dip switch settings 2-1 How to wire (1) Connect the remote controller to the double terminal bloc k on the indoor controller board of the master unit, that is, No .0 unit. (See Figure 1.) (2) Connect the double terminal bloc k o[...]
-
Pagina 52
OC194-52 3. CONTROL USING TW O REMO TE CONTROLLERS T wo remote controllers can be used to control either one unit or a group of units. Units operate according to the latest com- mand from either of the two remote controllers. Bef ore operation, be sure to set one remote controller as the “main controller” and the other as the “sub controller?[...]
-
Pagina 53
OC194-53 NO TE1 : Install the relay bo x where you can be ser viced it easily . NO TE2 : For control circuit wiring, use a wire of No . 14 A WG or a control cable according to the po wer supply of control circuit. NO TE3 : When the power supply of the control circuit is 208/230V A C , ● Do not connect the control circuit wire to the remote contro[...]
-
Pagina 54
OC194-54 6. MUL TIPLE REMO TE CONTROL DISPLA Y Y ou can control se v eral units with a multiple remote control displa y , by wiring an optional multiple display adapter (P A C-SA88HA-E) with relays and lamps on the market. How to wire (1) Connect the multiple displa y adapter to the connector CN51 on the indoor controller board. (2) Wire three of t[...]
-
Pagina 55
OC194-55 DISASSEMBL Y PR OCEDURE 14 OPERA TING PROCEDURE PHO T OS&ILLUSTRA TIONS 1. Removing the air intake grille (1) Slide the le ver in the direction of the arro w 1 . (2) Open it 90 deg. (3) Slide the intake g rill in the direction of the arrow 2 and remov e it. (4) Slide the two knobs on the left and right in the direction of the arrow 3 a[...]
-
Pagina 56
OC194-56 OPERA TING PROCEDURE PHO T OS&ILLUSTRA TIONS 4. Removing the drain pump, drain sensor , and indoor coil thermistor (1) Remov e the fan (nut). (2) Remov e the electr ical box (3 scre ws). (3) Remov e the ser vice panel screws (2 pcs). (4) Hold the knob and remov e the ser vice panel. (5) Remov e the drain pump set screws (2 pcs). (6) Re[...]
-
Pagina 57
OC194-57 15 P AR TS LIST PL12FK, PL18FK2, PL24FK2 P ANEL P ARTS PL12FK 1 , PL18FK2 1 , PL24FK2 1 1 2 3 4 5 6 1 1 1 4 1 1 1 1 1 4 1 1 1 1 1 4 1 1 1 1 1 4 1 1 MV F2 INDOOR PANEL 250V 0.5A No. Parts No. Parts Name Specifications Drawing No. Q'ty/set Price Unit Amount Remarks Circuit Diagram Symbol Recom- mended Q'ty PL 12 18 24 FK2 FK2 1 FK2[...]
-
Pagina 58
OC194-58 PL12FK, PL18FK2, PL24FK2 FUNCTIONAL P ARTS PL12FK 1 , PL18FK2 1 , PL24FK2 1 2 3 16 17 18 15 26 5 1 11 14 19 21 24 27 6 7 8 10 12 13 4 9 25 23 20 22 29[...]
-
Pagina 59
OC194-59 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 3P (L1,N,GR) 2P (1,2) 2P (1,2) 2P (1,2) SGR-25 DTC SGR-37 DTC 12 + 220V 8.5 + 220V 250V 6A 3P (L1,N,GR) 39ft 33ft TB2 TB5 TB4 TB4,5 MF1 MF1 C1 C1 I.B I.B F1 TB[...]
-
Pagina 60
OC194-60 PL30FK2, PL36FK3, PL42FK2 FUNCTIONAL P ARTS PL30FK2 1 , PL36FK3 1 , PL42FK2 1 2 3 27 27 5 15 16 17 18 1 4 7 8 9 10 12 13 11 6 16 14 20 22 25 19 24 26 21 23 29[...]
-
Pagina 61
OC194-61 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 6 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 6 1 1 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 6 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 6 1 1 TB2 TB5 TB4 TB4,5 MF1,2 MF1,2 C1,2 I.B I.B F1 TB12 T DP[...]
-
Pagina 62
OC194-62 1 2 3 4 5 6 1 1 2 8 2 1 1 1 2 8 2 1 1 1 2 8 2 1 1 1 2 8 2 1 MV F2 INDOOR PANEL 250V 0.8A No. Parts No. Parts Name Specifications Drawing No. Q'ty/set Price Unit Amount Remarks Circuit Diagram Symbol Recom- mended Q'ty PL 30 36 42 FK2 FK2 1 FK3 FK3 1 FK2 FK2 1 1 1 2 8 2 1 1 1 2 8 2 1 T7W 413 003 T7W 410 223 R01 K01 500 R01 K01 054[...]
-
Pagina 63
OC194-63 OPTIONAL P AR TS 16 1-2 Feature of program timer (1) Daily timer function Daily timer can be set in 30 minutes units f or up to 24 hours. Each unit can be set f or unit ON, unit OFF , or setbac k operation. (2) Setback oper ation (P AC-SC32PT A) Set back oper ation is useful for reducing running costs e.g. At a hotel with a 24-hour system [...]
-
Pagina 64
OC194-64 1-4 Names and functions <P AC-SC32PT A> WEEKL Y TIMER SETTING DISPLA Y Sets timer for a w eek. SET/MONITOR SET SM TWT F S MONITOR PROGRAM TIMER PAC-SC32PTA TODAY ON WEEKLY SETTING OFF ON SET BACK OFF CLOCK DAILY TIMER SET BACK SET BACK DAILY SETTING 12 15 18 21 24 036 1 2 15 CURRENT TIME DISPLA Y During MONITOR status ,current time i[...]
-
Pagina 65
OC194- 65 1 2 3 4 5 BRN RED ORN YLW GRN 3. MUL TIPLE REMO TE CONTROLLER AD APTER This adapter is needed f or remote indication (operation/check). Adapter connection is described on page 49. P ar t No. P AC-SA88HA-E Pa r t N o. Applicable Model P AC-SG03TM-E PL12/18/24/30/36/42FK Pa r t N o. Applicable Model P AC-SG01KF PL12/18/24/30/36/42FK 5. HIGH[...]
-
Pagina 66
© Copyright 2000 MITSUBISHI ELECTRIC ENGINEERING CO .,L TD . Distributed in Jun. 2001. No.OC256 REVISED EDITION-B 20 Distributed in Mar . 2001. No.OC256 REVISED EDITION-A 20 Distributed in Dec. 2000. No.OC256 nPrinted in Atlanta 07/2001 New pub lication, effectiv e Jun. 2001 Specifications subject to change without notice Oc256b~1.qxd 7/20/2001 10[...]
-
Pagina 67
3400 Lawrenceville Suwanee Road ● Suwanee, Georgia 30024 Toll Free: 800-433-4822 ● Toll Free Fax: 800-889-9904 www.mrslim.com Specifications are subject to ch ange without notice.[...]