National Instruments NI 6232 manuale d’uso
- Visualizza on-line o scarica il manuale
- 180 pagine
- 2.84 mb
Vai alla pagina of
Manuali d’uso simili
-
Network Card
National Instruments GPIB-SCSI-A
35 pagine 0.98 mb -
Network Card
National Instruments CFP-CTR-502
22 pagine 0.44 mb -
Network Card
National Instruments 371685C-01
39 pagine 0.39 mb -
Network Card
National Instruments USB Digitizers NI USB-5132
9 pagine 0.46 mb -
Network Card
National Instruments PXI Terminal Block NI TB-2708
12 pagine 0.87 mb -
Network Card
National Instruments LM3647
9 pagine 0.19 mb -
Network Card
National Instruments NI 8171 Series
73 pagine 1.16 mb -
Network Card
National Instruments 850
40 pagine 0.21 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso National Instruments NI 6232. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica National Instruments NI 6232 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso National Instruments NI 6232 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso National Instruments NI 6232 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo National Instruments NI 6232
- nome del fabbricante e anno di fabbricazione National Instruments NI 6232
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature National Instruments NI 6232
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio National Instruments NI 6232 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti National Instruments NI 6232 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio National Instruments in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche National Instruments NI 6232, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo National Instruments NI 6232, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso National Instruments NI 6232. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
DAQ M Series NI 6232/6233 User Manual NI 6232/6233 User Manual July 2006 371995A-01[...]
-
Pagina 2
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 6555 78[...]
-
Pagina 3
Important Information Warranty The NI 6232/6233 is warranted against defects in materi als a nd workmanship for a period of three years from the date o f ship ment, as evidenced by receipts or other documentati on. National Instruments wil l, at its option, repair or replace equipment that proves to be defect ive during the warranty period. This wa[...]
-
Pagina 4
NATIONAL INSTRUMENTS PRODUCTS ARE IN CORPORATED IN A SYSTEM OR APPLICATION, INC LUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROC ESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLI CATION.[...]
-
Pagina 5
Compliance Compliance with FCC/Canada Radio Frequency Interference Regulations Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations onl y) [...]
-
Pagina 6
© National Instruments Corporation vii NI 6232/6233 User Manual Contents About This Manual Conventions ............ .............. .............. .............. .............. .............. ............... .............. .... x v Related Documentation ............ .............. .............. .............. .............. .............. ........[...]
-
Pagina 7
Contents NI 6232/6233 User Manual viii ni.com Chapter 3 Connector Information I/O Connector Signal Descriptions .................. .............. ................. .............. .............. ... 3-1 RTSI Connector Pinout ............... .............. .............. .............. .............. .............. ............ 3-3 Chapter 4 Analog I[...]
-
Pagina 8
Contents © National Instruments Corporation ix NI 6232/6233 User Manual Using an External Source ...................... .............. .............. .............. .. 4-23 Routing AI Sa mple Clock Signal to an Output Terminal ................. 4-23 Other Timing Requirements.................. ................. .............. ............. 4-23 AI [...]
-
Pagina 9
Contents NI 6232/6233 User Manual x ni.com AO Sample Clock Signal ............... .............. ................. .............. .............. ...... 5-8 Using an Internal Source .... .............. .............. .............. .............. ...... 5-9 Using an External Source ........... .............. .............. .............. ...........[...]
-
Pagina 10
Contents © National Instruments Corporation xi NI 6232/6233 User Manual Position Measurement ............. ........................................................ ................ 7- 16 Measurements Using Quadrature Encoders .................... .............. .... 7-16 Measurements Using Two Pulse Encoders .................. .............. .....[...]
-
Pagina 11
Contents NI 6232/6233 User Manual xii ni.com Prescaling ............. .............. ............... .............. .............. .............. .............. ...... 7-34 Duplicate Count Prevention ................ .............. ............... .............. ................. 7-35 Duplicate Count Preventio n Example ... .............. .........[...]
-
Pagina 12
Contents © National Instruments Corporation xiii NI 6232/6233 User Manual Using RTSI Terminals as Timing Input Sign als ............... .............. .............. .. 10-6 RTSI Filters ............... .............. .............. .............. .............. .............. .............. .. 10-6 PXI Clock and Trigger Signals ................. [...]
-
Pagina 13
© National Instruments Corporation xv NI 6232/6233 User Manual About This Manual The NI 6232/6233 User Manual co ntains informatio n about usi ng the National Instruments 6232/623 3 M Series data acquisition (DA Q) de vices with NI-D A Qmx 8.0 and la ter . NI 6232/6233 devices feature eight analog input (AI) channels, four analog outp ut (A O) cha[...]
-
Pagina 14
About This Manual NI 6232/6233 User Manual xvi ni.com monospace T ext in this font denotes text or ch aracters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper na mes of disk dri ves, paths, directories, programs, subprograms, su broutines, d evice names, fun[...]
-
Pagina 15
About This Manual © National Instruments Corporation xvii NI 6232/6233 User Manual The NI-D AQmx for Linux Configuration Guide provi des conf iguration instructions, templates, and instructions for using test panels. Note All NI-D A Qmx documentatio n for Linux is installed at /usr/local/ natinst/nidaqmx/docs . NI-DAQmx Base The NI-D A Qmx Base Ge[...]
-
Pagina 16
About This Manual NI 6232/6233 User Manual xviii ni.com • Getting St arted»Gett ing Started wi th D A Q —Includes ov ervie w information and a tutorial to learn how to take an NI-D A Qmx measurement in LabVIEW using the D A Q Assistant. • VI and Function Refer en ce»Measur ement I/O VIs and Functions —Describes the LabVIEW NI-D A Qmx VIs [...]
-
Pagina 17
About This Manual © National Instruments Corporation xix NI 6232/6233 User Manual .NET and V isual C++ class libraries. This help collection is inte grated into the V isual Studio .NET documentation . In V isual Studio .NET , select Help»Contents . Note Y ou must ha ve V isual Studio .NET installed to view the NI Measur ement Studio Help . Device[...]
-
Pagina 18
© National Instruments Corporatio n 1-1 NI 6232/6233 User Manual 1 Getting Started M Series NI 6232/6233 devices feature sixteen analog input (AI) channels, two analog output (A O) chann els, two counters, six lines of digital input (DI), and four lines of digital outpu t (DO). If you hav e not already installed your device, refer to the D A Q Get[...]
-
Pagina 19
Chapter 1 Getting Started NI 6232/6233 User Manual 1-2 ni.com Device Specifications Refer to the NI 6232/6233 Specifications , av ailable on the NI-D A Q Device Document Br o wser or ni.com/manuals , fo r more detailed inf ormation on the NI 6232/6233 device. Device Accessories and Cables NI of fers a variety of accessories and cables to use with y[...]
-
Pagina 20
© National Instruments Corporatio n 2-1 NI 6232/6233 User Manual 2 DAQ System Over view Figure 2-1 sho w s a typical D A Q sy st em, which includes sensors, transducers, cables that connect the various de vices to the accessories, the M Series de vi ce, programming software, and a PC. The following sections cov er t he components of a typi cal D A[...]
-
Pagina 21
Chapter 2 DAQ System Over view NI 6232/6233 User Manual 2-2 ni.com Figure 2-2. General NI 6232/62 33 Block Diagram DAQ-STC2 The D A Q-STC 2 implements a high-performan ce digital engine for NI 6 232/6233 data acquisit ion hardware. Some key features of this engine include the following: • Flexible AI and A O sample and con vert timing • Many tr[...]
-
Pagina 22
Chapter 2 DAQ System Overview © National Instruments Corporatio n 2-3 NI 6232/6233 User Manual Calibration Circuitr y The M S eries analog inputs and outputs have calibration circuitry to correct gain and of fset errors. Y ou can calibr ate the de vice to minimize AI and A O errors caused by time and temperatur e drift at run time. No external cir[...]
-
Pagina 23
Chapter 2 DAQ System Over view NI 6232/6233 User Manual 2-4 ni.com Cables and Accessories NI offers a v ariety of produ cts to use with NI 6232/6233 devices, including cables, connector blocks, and other accessories, as follows: • Cables and cable assemblies – Shielded – Unshielded ribbon • Scre w terminal connector bl ocks, shielded and un[...]
-
Pagina 24
Chapter 2 DAQ System Overview © National Instruments Corporatio n 2-5 NI 6232/6233 User Manual Programming Devices in Software National Instruments measurement de vices are packaged with NI-D A Q dri ver software, an e x tensiv e lib rary of functions and VIs you can call from your application software, such as LabVIEW or LabW ind ows/CVI, to prog[...]
-
Pagina 25
© National Instruments Corporatio n 3-1 NI 6232/6233 User Manual 3 Connector Information The I/O Connector Si gnal Descriptions and RTSI Connector Pinou t sections contain information on M Series connectors. Refer to Appendix A, Device-Specific In formation , for device I/O connector pinouts. I/O Connector Signal Descriptions T able 3-1 describes [...]
-
Pagina 26
Chapter 3 Connector Information NI 6232/6233 User Manual 3-2 ni.com A O GND — — Analog Output Ground —A O GND is t he refere nce for A O <0..1>. AI GND and A O GND are connected on the dev ice. Note: AI GND and AO GND are isolated from earth ground, chassis ground, P0.GND, and P1.GND. PFI <0..5>/P0.<0..5> P0.GND Input Progra[...]
-
Pagina 27
Chapter 3 Connector Information © National Instruments Corporatio n 3-3 NI 6232/6233 User Manual R TSI Connector Pinout Refer to the RTSI Connector Pinout section of Chapter 10, Digital Routing and Clock Generation , for information on the R TSI connector .[...]
-
Pagina 28
© National Instruments Corporatio n 4-1 NI 6232/6233 User Manual 4 Analog Input Figure 4-1 shows the analog in put circuitry o f NI 6232/6233 devices. Figure 4-1. NI 6232/6233 Analog Input Cir cuitry Analog Input Circuitr y I/O Connector Y ou can connect analog input signals to the M Series device through the I/O connector . The proper way to conn[...]
-
Pagina 29
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-2 ni.com Ground-Reference Settings The analog input ground-reference settings circu itry selects between differential and referenced single-ende d modes. Each AI channel can use a different mode. Instrumentation A mplifier (NI-P GIA) The NI programmable gain instrume ntation amplifier (PGIA) is a m[...]
-
Pagina 30
Chapter 4 Analog Input © National Instruments Corporatio n 4-3 NI 6232/6233 User Manual 16-bit ADC con verts analog inputs into one of 65,536 (= 2 16 ) codes—that is, one of 65,536 possibl e digital valu es. These v alues are spread fairly ev enly acro ss the input range. So, for an input range of –10 V to 10 V , the voltage of each code of a [...]
-
Pagina 31
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-4 ni.com The AI gr ound-re fer en ce setting determines how you should con nect your AI signals to the NI 6232/6233 device. Refer to the Connecting Analog Voltage Input Signals section fo r more information. Ground-reference settings are programmed on a per-channel basis. For example, you might con[...]
-
Pagina 32
Chapter 4 Analog Input © National Instruments Corporatio n 4-5 NI 6232/6233 User Manual T able 4 -3 shows how signals are routed to the NI-PGIA. For dif ferential measurements, AI 0 and AI 8 are the posi tiv e and negativ e inputs of dif f erential analog input ch annel 0. F or a complet e list of si gnal pairs that form dif ferential input channe[...]
-
Pagina 33
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-6 ni.com Figure 4-3. Enabling Multimode Scanning in LabVIEW Multichannel Scanning Considerations M Series de vices can scan multiple chan nels at high rate s and digitize the signals accurately . Ho wev er , you should consider sev e ral issues when designing your measurement system to ensure the h[...]
-
Pagina 34
Chapter 4 Analog Input © National Instruments Corporatio n 4-7 NI 6232/6233 User Manual Settling times increase when scanning high-im pedance signals due to a phenomenon called charge injection. Multiplexers contain switches, usually made of switched capacitors. Wh en one of the channels, for example channel 0, is selected in a multiplexer , t hos[...]
-
Pagina 35
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-8 ni.com 1/50 LSB) of the ±10 V range. Some de vices can take many microseconds for the circuitry to settle this mu ch. T o avoid this ef fect, you should arrange you r channel scanning ord er so that transitions from large to small input ranges are infrequent. In general, you do not need this ext[...]
-
Pagina 36
Chapter 4 Analog Input © National Instruments Corporatio n 4-9 NI 6232/6233 User Manual A void Scanning Faster Than Necessar y Designing your system to scan at s l ower speeds gi ves the PGIA more time to settle to a more accurate le vel. Here are two e xamples to consider . Example 1 A veraging many AI samples can incr ease the accurac y of the r[...]
-
Pagina 37
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-10 ni.com each ADC con version. In NI-D A Q mx , software-timed acquisitions are referred to as having on-demand timi ng. Software-timed acquisitions are also referred to as immediate or static acquisitio ns and are typically used for reading a single sample of data. Hardware-Timed Acquisitions W i[...]
-
Pagina 38
Chapter 4 Analog Input © National Instruments Corporation 4-11 NI 6232/6233 User Manual be transferred to host memory . The device generates an error in this case. W ith con tinuous operations, if the user program does not read data out of the PC buf fer fast enough to keep up w ith the data transfer, the b uffer could reach an ov erflow condition[...]
-
Pagina 39
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-12 ni.com Refer to the Analog Input Ground-Reference Setti ngs section for descriptions of DIFF and RSE modes. T ypes of Signal Sources When configuring the input channels and maki ng signal connections, first determine whether the signal sources are floating or ground-referenced. For isolated meas[...]
-
Pagina 40
Chapter 4 Analog Input © National Instruments Corporation 4-13 NI 6232/6233 User Manual two reference planes. Isolated front ends require a ground-reference point to the signal that is being measured. Floating Signal Sources A floating signal source is not con nected to the building ground system (earth or chassis ground), but has an isolated grou[...]
-
Pagina 41
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-14 ni.com Use DIFF input connections fo r any cha nnel that meets any of the following conditions: • The input signal is low le vel (less than 1 V). • The leads connecting the signal to the de vice are greater than 3 m (10 ft). • The input signal requires a separate ground-reference point or [...]
-
Pagina 42
Chapter 4 Analog Input © National Instruments Corporation 4-15 NI 6232/6233 User Manual W ith th is type of connection, the PGIA rejects both the common -mode noise in the si gnal and the gro und potential difference between the signal source and the de vice ground, shown as V cm in the figure. Refer to the NI 6232/6233 S pecifications for the usa[...]
-
Pagina 43
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-16 ni.com Figure 4-5. Differential Connections fo r Floating Signal Sources This figure sho ws AI GND connected to the ground reference point for the floating signal source. If you do not connect AI GND, the source is not likely to remain withi n the common-mo de signal range of th e PGIA due to th[...]
-
Pagina 44
Chapter 4 Analog Input © National Instruments Corporation 4-17 NI 6232/6233 User Manual signal connects to the positive input of the PGIA, and the ground connects to the negativ e input of the PGIA. Y ou shou ld only use single-ended input connections if the input si gnal meets the following conditions. • The input signal is high-level (greater [...]
-
Pagina 45
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-18 ni.com Figure 4-6. Single-Ended Connections for Fl oating Signal Sour ces (RSE Configuration) Refer to the NI 6232/623 3 Specifications for the usable range of V cm . Common-Mode Sign al Rejection Considerations For signal sources that are already re ferenced to some ground point w ith respect t[...]
-
Pagina 46
Chapter 4 Analog Input © National Instruments Corporation 4-19 NI 6232/6233 User Manual • Use individually shielded, twisted-pair wires to connect AI signals to the device. W ith this type of wire, the signals attached to the positive and negati ve input channels are twisted together and then cov ered with a shield. Y ou th en connect this shiel[...]
-
Pagina 47
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-20 ni.com 1/Sample Period = Samp le Rate Figure 4-8. Int erval Sampling ai/Con vertClock control s the Con vert Period, which is determ ined by the following equation: 1/Con vert Period = Conv ert Rate By default, the NI-D A Qmx driv er chooses the fastest Channel Clock rate possible while still al[...]
-
Pagina 48
Chapter 4 Analog Input © National Instruments Corporation 4-21 NI 6232/6233 User Manual the PCI-6220 M Series device, a sampling rate of 40 kHz for two channels would result in a Con vert Clock rate of 80 kHz. Maximum settling time for the amplifier is also very important. For example, to ensure accurac y to within ± 1 LSB on an NI 623 x M Series[...]
-
Pagina 49
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-22 ni.com Figure 4-10. Pretriggered Data Acquisition Example If an ai/ReferenceT rigger pulse occurs before the specified number of pretrigger samples are acquired, the trigger pulse is ignored. Otherwise, when the ai/ReferenceT rigger pulse occurs, the sample coun ter value decrements until the sp[...]
-
Pagina 50
Chapter 4 Analog Input © National Instruments Corporation 4-23 NI 6232/6233 User Manual Using an Inte rnal Source One of the follo wing internal signals can dri ve ai/SampleClock. • Counter n Internal Output • AI Sample Clock T imebase (divided down) •A s o f t w a r e p u l s e A programma ble internal counter di vides do wn the sample cl o[...]
-
Pagina 51
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-24 ni.com A counter on y our device internally generates ai/SampleClock unless you select some external source. ai/StartT rigger starts this counter and either software or hardware can stop it when a f inite acquisition completes. When using an internally generated ai/S ampleClock, you also can spe[...]
-
Pagina 52
Chapter 4 Analog Input © National Instruments Corporation 4-25 NI 6232/6233 User Manual sources for ai/SampleClock. Y ou can c onfigure the polarity select ion for ai/SampleClockT imebase as ei ther rising or falling edge. AI Convert Clock Signal Use the AI Con vert Clock (ai/Con vertClock) signal to initiate a sing le A/D con version on a single [...]
-
Pagina 53
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-26 ni.com Using an External Source Use one of the f ollowing external sign als as the source of ai/Con vertClock: • Input PFI <0..5> •R T S I < 0 . . 7 > •P X I _ S T A R Routing AI Convert Clo ck Signal to an Output Te r m i n a l Y ou can ro ute ai/Con vertClock (as an acti ve l[...]
-
Pagina 54
Chapter 4 Analog Input © National Instruments Corporation 4-27 NI 6232/6233 User Manual Other Timing Requirements The sample and con version lev el timing of M Series de vices work such that clock signals are gated of f unless the proper timing requir ements are met. For e xample, the de vice ignores both ai/SampleClock and ai/Con vertClock until [...]
-
Pagina 55
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-28 ni.com ai/Con vertClockT imebase is not av a ilable as an output on the I/O connector . AI Hold Complete Event Signal The AI Hold Complete Event (ai/HoldCompleteEvent) signal generates a pulse after each A/D con version begins. Y o u can route ai/HoldCompleteEvent out to any output PFI <6..9&[...]
-
Pagina 56
Chapter 4 Analog Input © National Instruments Corporation 4-29 NI 6232/6233 User Manual Y ou also can specif y whether the measurement acquisitio n begins on the rising edge or falling edge of ai/StartTrigger . Routing AI Start T rigger to an Output T erminal Y ou can rout e ai/StartTrigger out to any output PFI <6..9> or R TSI <0 ..7>[...]
-
Pagina 57
Chapter 4 Analog Inpu t NI 6232/6233 User Manual 4-30 ni.com Figure 4-14. Reference T rigger Final Buffer Using a Digital Source T o use ai/ReferenceT rigger with a di gital source, specify a source and an edge. The source can be an y of the follo wing signals: • Input PFI <0..5> •R T S I < 0 . . 7 > •P X I _ S T A R The source al[...]
-
Pagina 58
Chapter 4 Analog Input © National Instruments Corporation 4-31 NI 6232/6233 User Manual Using a Digital Source T o use ai/SampleClock, specify a sour ce and a polarity . The source can be any of the follo win g signals: • Input PFI <0..5> •R T S I < 0 . . 7 > •P X I _ S T A R The source also can be one of sev eral ot her internal[...]
-
Pagina 59
© National Instruments Corporatio n 5-1 NI 6232/6233 User Manual 5 Analog Output NI 6 232/6233 devices hav e two A O channels that are co ntrolled by a single clock and are capable of wav eform generatio n. Figure 5-1 shows the analog output circuitry of NI 6232/6233 devices. Figure 5-1. NI 6232/6233 Analog Output Circu itr y Analog Output Circuit[...]
-
Pagina 60
Chapter 5 Analog Output NI 6232/6233 User Manual 5-2 ni.com D ACs. It allows you to do wnload the points of a wa veform to your M Series device without host computer interaction. AO Sample Clock The A O Sample Clock signal reads a sample from the D A C FIFO and generates the A O voltage. Isolation Barrier and Digital Isolators The digital isolators[...]
-
Pagina 61
Chapter 5 Analog Output © National Instruments Corporatio n 5-3 NI 6232/6233 User Manual Hardware-Ti med Generations W ith a hard ware-timed generation, a di gital hardware signal controls the rate of the generation. This signal can be generated internally on your device or pro vided externally . Hardware-timed generations ha ve se veral advantage[...]
-
Pagina 62
Chapter 5 Analog Output NI 6232/6233 User Manual 5-4 ni.com Regeneration is the repetition of the data that is already in the buf fer . Standard regeneration is when data from the PC b uffer is continually downloaded to the FIFO to be written out. New data can be written to the PC buf fer at any time without disru pting the ou tput. W ith FIF O reg[...]
-
Pagina 63
Chapter 5 Analog Output © National Instruments Corporatio n 5-5 NI 6232/6233 User Manual Figure 5-2. An alog Output Connections Analog Output T iming Signals Figure 5-3 summarizes all of the timi ng options provided by the analog output timing eng ine. Load Load V OUT V OUT + – + – AO 1 AO 0 Channel 1 Channel 0 I/O Connector AO G N D Isolation[...]
-
Pagina 64
Chapter 5 Analog Output NI 6232/6233 User Manual 5-6 ni.com Figure 5-3. Analog Output T iming Options NI 6232/6233 devices feature the following A O (wa veform generation) timing signals. • AO Start Trigger Signal • AO Pause Trigger Signal • AO Sample Clock Signal • AO Sample Clock Timebase Signal AO Start T rigger Signal Use the A O Start [...]
-
Pagina 65
Chapter 5 Analog Output © National Instruments Corporatio n 5-7 NI 6232/6233 User Manual The source also can be one of several internal signals on your D A Q device. Refer to Device Routing in MAX in the NI-D A Qmx Help or the LabVIEW 8.x Help for more i nformation. Y ou al so can specify whether the wav eform generation begins on the rising edge [...]
-
Pagina 66
Chapter 5 Analog Output NI 6232/6233 User Manual 5-8 ni.com deasserted and another edge of the sa mple clock is recei ved, as shown in Figure 5-5. Figure 5-5. ao/PauseT rigger with Other Signal Sour ce Using a Digital Source T o use ao/PauseT rigger, specify a source and a polarity . The source can be one of the following signals: • Input PFI <[...]
-
Pagina 67
Chapter 5 Analog Output © National Instruments Corporatio n 5-9 NI 6232/6233 User Manual Using an Inte rnal Source One of the follo wing internal signals can dri ve ao/SampleClock. • A O Sample Clock Timebase (di vided down) • Counter n Internal Output A programmable internal counter divides do wn the A O Sample Clock T imebase signal. Using a[...]
-
Pagina 68
Chapter 5 Analog Output NI 6232/6233 User Manual 5-10 ni.com Figure 5-6. ao/SampleC lock an d ao/StartT rigger AO Sample Clock T imebase Signal The A O Sample Clock Timebase (ao/SampleClockT imebase) signal is di vided down to pro vide a source for ao/SampleClock. Y ou can ro ute any of the follo wing signals to be the A O Sample Clock T im ebase ([...]
-
Pagina 69
Chapter 5 Analog Output © National Instruments Corporation 5-11 NI 6232/6233 User Manual • Finite gener ation • Continuous generation • W aveform generation Y ou can perform th ese generations through program med I/O, interrupt, or DMA data transfer mechanisms. Some of the applications also use start triggers and pause triggers. Note For mor[...]
-
Pagina 70
© National Instruments Corporatio n 6-1 NI 6232/6233 User Manual 6 Digital Input and Output NI 6232/6233 devices hav e six static digita l input lines, P0.<0..5>. These lines also can be used as PFI inputs. The voltage input and output levels and the current driv e lev el of the DI and DO lines are listed in the NI 6232/6233 S pecifications [...]
-
Pagina 71
Chapter 6 Digital Input and Output NI 6232/6233 User Manual 6-2 ni.com Connecting Digital I/O Signals The DI signals P0.<0..5> are referenced to P0.GND and DO signals P1.<0..3> are referenced to P1.GND. Figures 6 -1 and 6-2 show P0.<0..5> and P1.<0..3> on the NI 6232 and the NI 6233 device, respecti vely . Digital input and [...]
-
Pagina 72
Chapter 6 Digital Input and Output © National Instruments Corporatio n 6-3 NI 6232/6233 User Manual Figure 6-2. NI 6233 Digital I/O Co nnections (DO Sink) Caution Exceeding the maximum input voltage or maximum working v oltage ratings, which are listed in the NI 6232/6233 Specifications , can damage the D A Q device and the computer . NI is not li[...]
-
Pagina 73
Chapter 6 Digital Input and Output NI 6232/6233 User Manual 6-4 ni.com Getting Started with DIO Applications in Software Y ou can use NI 6232/6233 devices in the follo wing digi tal I/O applications: • Static digital input • Static digital output Note For more information about programming digital I/ O applications and triggers in software, ref[...]
-
Pagina 74
© National Instruments Corporatio n 7-1 NI 6232/6233 User Manual 7 Counters NI 6 232/6233 devices hav e two general-purpose 32-bi t counter/timers and one frequency generator , as shown in Figure 7-1. The general-purpose counter/timers can be used for many measurement and pulse generation applications. Caution When making measurem ents, take into [...]
-
Pagina 75
Chapter 7 Counters NI 6232/6233 User Manual 7-2 ni.com Figure 7-1. M Series Counters The counters have se ven input signals, although in most applications onl y a fe w inputs are used. For information on connecting co unter signals, refer to the Default Counter Terminals section. Counter 0 Counter 0 Source (Counter 0 Timebase) Counter 0 Aux Counter[...]
-
Pagina 76
Chapter 7 Counters © National Instruments Corporatio n 7-3 NI 6232/6233 User Manual Counter Input Applications Counting Edges In edge counting appl ications, the co unter counts edges on its Source after the counter is armed. Y ou can conf igure the counter to count risi ng or falling edges on its Source input. Y ou also can control the direction [...]
-
Pagina 77
Chapter 7 Counters NI 6232/6233 User Manual 7-4 ni.com Figure 7-3. Single Point (On-Demand) Edge Counting with Pause T rigger Buffered (Sample Clock) Edge Counting W ith buffered edge counting (edge counting using a sample clock), the counter counts the nu mber of edges on the Source input after the counter is armed. The v alue of the counter is sa[...]
-
Pagina 78
Chapter 7 Counters © National Instruments Corporatio n 7-5 NI 6232/6233 User Manual Non-Cumulative Buffe red Edge Counting Non-cumulativ e edge counting is similar to buf f ered (sample clock) edge counting. Ho wev er, the counter resets after each acti ve edge of the Sample Clock. Y ou can route the Sample Clock to the Gate input of the counter .[...]
-
Pagina 79
Chapter 7 Counters NI 6232/6233 User Manual 7-6 ni.com Pulse-Width Measurement In pulse-width measuremen ts, the counter measures the width of a pulse on its Gate input signal. Y ou can configur e the counter to measure the width of high pulses or low pulses on the Gate signal. Y ou can route an internal or external periodic clock signal (wit h a k[...]
-
Pagina 80
Chapter 7 Counters © National Instruments Corporatio n 7-7 NI 6232/6233 User Manual Buffered Pulse-Width Measurement Buffered pulse-width measurement is similar to single pulse-width measurement, b ut buf fered pulse-wi dth measurement ta kes measurements ov er multiple pulses. The counter counts the number of edges o n the Source input whi le the[...]
-
Pagina 81
Chapter 7 Counters NI 6232/6233 User Manual 7-8 ni.com of rising (or falling) edges occurring on the Source input between the two acti ve edges of the Gate signal. Y ou can calculate the period of the Gate input by multiplying the perio d of the Source signal by the number of edges returned by the counter . Single Period Measurement W ith sing le p[...]
-
Pagina 82
Chapter 7 Counters © National Instruments Corporatio n 7-9 NI 6232/6233 User Manual Figure 7-9. Buffered Period Measu rement Note that if you are using an external signal as the Source, at least one Source pulse should occu r between each acti ve edge of the Gate signal. This condition ensures that correct v alues are returned b y th e counter . I[...]
-
Pagina 83
Chapter 7 Counters NI 6232/6233 User Manual 7-10 ni.com Buffered Semi-Period Measurement In b uffered semi-period measurement, on each edge of the Gate signal, the counter stores the count in a hardware sa ve register . A DMA con troller transfers the stored v a lues to host memory . The counter begins counting when it is armed. The arm usually occ[...]
-
Pagina 84
Chapter 7 Counters © National Instruments Corporation 7-11 NI 6232/6233 User Manual Y ou can route the signal to measure (F1) to the Gate of a counter . Y ou can route a kno wn timebase (Ft) to th e Source of the counter . The known timebase can be 80MHzT imebase. For si gnals that might be slower than 0.02 Hz, use a slower kno wn timebase. Y ou c[...]
-
Pagina 85
Chapter 7 Counters NI 6232/6233 User Manual 7-12 ni.com Figure 7-12. Method 1b Method 2—Measure High Frequency with T wo Counters In this method, you measure one pul se of a known width using your signal and deri ve the frequency of your signal fr om the result. This met hod is good for high frequency signals. In this method, you route a pulse of[...]
-
Pagina 86
Chapter 7 Counters © National Instruments Corporation 7-13 NI 6232/6233 User Manual Figure 7-13. Method 2 Method 3—Measure Large Range of Frequencies Using T wo Counters By using two counters, yo u can accurately measure a signal that might be high or low frequency . This techniq ue is called recipr ocal fr equency measur emen t . In this method[...]
-
Pagina 87
Chapter 7 Counters NI 6232/6233 User Manual 7-14 ni.com Figure 7-14. Method 3 Then route the Counter 0 Internal Output signal to the Gate input of Counter 1. Y ou can route a signal of kno wn frequenc y (F2) to the Counter 1 Source input. F2 can be 80MHzTimebase. For signals that might be slo wer than 0.02 Hz, use a slo wer kno wn timebase. Configu[...]
-
Pagina 88
Chapter 7 Counters © National Instruments Corporation 7-15 NI 6232/6233 User Manual Consider a frequency measurement on a 50 kHz signal using an 80 MHz T imebase. This frequency corresponds to 1600 cycles of the 80 MHz T imebase. Y our measurement may return 1600 ±1 cycles depending on the phase of the signal with respect to the timebase. As your[...]
-
Pagina 89
Chapter 7 Counters NI 6232/6233 User Manual 7-16 ni.com For information on connecting co unter signals, refer to the Default Counter Terminals section. Position Measurement Y ou can use the coun ters to perform position measurements with quadrature encoders or two-pulse encoders. Y ou can measure angular position with X1, X2 , and X4 angular encode[...]
-
Pagina 90
Chapter 7 Counters © National Instruments Corporation 7-17 NI 6232/6233 User Manual Figure 7-15. X1 Encoding X2 Encoding The same behavior holds for X2 encodi ng ex cept the counter increments or decrements on each edge of channel A, depending on which channel leads the other . Each cycle results in two in crements or decrements, as sho wn in Figu[...]
-
Pagina 91
Chapter 7 Counters NI 6232/6233 User Manual 7-18 ni.com Channel Z behavior—when it goes high and how long it stays high—differs with quadrature encoder designs. Y ou mu st refer to the documentation for your quadrature encoder to obtain timing of channe l Z with respect to channels A and B. Y ou must then ensure that channel Z is high during at[...]
-
Pagina 92
Chapter 7 Counters © National Instruments Corporation 7-19 NI 6232/6233 User Manual For information on connecting co unter signals, refer to the Default Counter Terminals section. T wo-Signal Edge-Separation Measurement T wo-signal edge-separatio n measurement is similar to pulse-width measurement, except that there ar e two measurement signals—[...]
-
Pagina 93
Chapter 7 Counters NI 6232/6233 User Manual 7-20 ni.com Figure 7-20. Single T wo-Signal Edge-Separation Measurement Buffered T wo-Signal Edge- Separation Measurement Buffered and single two-signal edge-sep aration measurements are similar , but b uffered measurement m easures multiple interv als. The counter counts the number of rising (or falling)[...]
-
Pagina 94
Chapter 7 Counters © National Instruments Corporation 7-21 NI 6232/6233 User Manual Counter Output Applications Simple Pulse Generation Single Pulse Generation The counter can output a single pulse. The pulse appears on the Counter n Internal Output sign al of the counter . Y ou can specify a delay from when the counter is armed to the beginning o[...]
-
Pagina 95
Chapter 7 Counters NI 6232/6233 User Manual 7-22 ni.com Figure 7-23. Single Pulse Generation with Start T rigger Retriggerable Single Pulse Generation The counter can output a single pulse in response to each pulse on a hardware Start T rigger signal. The pu lses appear on the Counter n Internal Output signal of the co unter . Y ou can ro ute the S[...]
-
Pagina 96
Chapter 7 Counters © National Instruments Corporation 7-23 NI 6232/6233 User Manual Pulse T rain Generation Continuous Pulse T rain Generation This function generates a train of pul ses with program mable frequency and duty cycle. The pulses appear on the Counter n Internal Output signal of the counter . Y ou can specify a delay from when the coun[...]
-
Pagina 97
Chapter 7 Counters NI 6232/6233 User Manual 7-24 ni.com Frequency Generation Y ou can generate a frequency by using a counter in pulse train generation mode or by using the frequency generator circuit. Using the Frequency Generator The frequency generator can output a square wav e at many different frequencies. The frequency genera tor is independe[...]
-
Pagina 98
Chapter 7 Counters © National Instruments Corporation 7-25 NI 6232/6233 User Manual Frequenc y Output can be routed out to an y output PFI <6..9> or R TSI <0..7> terminal. All PFI terminal s are set to high-impedance at startup. In software, program th e frequency ge nerator as you would program one of the counters for pulse train gene[...]
-
Pagina 99
Chapter 7 Counters NI 6232/6233 User Manual 7-26 ni.com Nyquist fr equency of the system. Fi gure 7-28 shows an example of pulse generation for ETS; the delay from the tr igger to the pulse increases after each subsequent Gate acti ve edge. Figure 7-28. Pulse Generation for ETS For information on connecting co unter signals, refer to the Default Co[...]
-
Pagina 100
Chapter 7 Counters © National Instruments Corporation 7-27 NI 6232/6233 User Manual Counter n Source Signal The selected edge of the Counter n Source signal increments and decrements the counter v alue dependin g on the application the counter is performing. T abl e 7-3 lists how this terminal is used in various applications. Routing a Signal to C[...]
-
Pagina 101
Chapter 7 Counters NI 6232/6233 User Manual 7-28 ni.com Routing Counter n Source to an Output T erminal Y ou can ro ute Counter n Source out to any output PFI <6..9> or R TSI <0..7> terminal. All PFIs are set to high-impedance at startup. Counter n Gate Signal The Counter n Gate signal can perform many dif ferent operations depending on[...]
-
Pagina 102
Chapter 7 Counters © National Instruments Corporation 7-29 NI 6232/6233 User Manual Routing a Signal to Counter n Aux Each counter has independent input selectors for the Counter n Aux sig nal. Any of the following signals can be routed to t he Counter n Aux input. •R T S I < 0 . . 7 > • Input PFI <0..5> • ai/ReferenceT rigger ?[...]
-
Pagina 103
Chapter 7 Counters NI 6232/6233 User Manual 7-30 ni.com Counter n HW Arm Signal The Counter n HW Arm signal enab les a counter to begin an input or out put function. T o begin any counter input or output function, you must first enable, or arm, the counter . In some applications , such as b uff ered semi-period measurement, the counter begins count[...]
-
Pagina 104
Chapter 7 Counters © National Instruments Corporation 7-31 NI 6232/6233 User Manual Routing Counter n Internal Output to an Output Te r m i n a l Y ou can ro ute Counter n Internal Outp ut to any ou tput PFI <6..9> or R TSI <0 ..7> terminal. All output PFIs are set to hi gh-impedance at startup. Frequency Output Signal The Frequency Ou[...]
-
Pagina 105
Chapter 7 Counters NI 6232/6233 User Manual 7-32 ni.com Y ou can use these defaults or select other sources and destin ations for the counter/timer si gnals in NI-DA Qmx. Ref er to Connectin g Counter Signals in the NI-D AQmx Help or the LabVIEW 8.x Help fo r more inform ation on how to connect your signals for common counter measurements and gener[...]
-
Pagina 106
Chapter 7 Counters © National Instruments Corporation 7-33 NI 6232/6233 User Manual Pause T r igger Y ou can use pause tri ggers in edge counting and continuou s pulse generation applications. For edge counting acquisitions, the counter stop s counting edges whil e the external trigger signal is low and resumes when the signal goes high or vice ve[...]
-
Pagina 107
Chapter 7 Counters NI 6232/6233 User Manual 7-34 ni.com The filter setting for each input can be conf igured independently . On power up, the filters are disabled. Figure 7- 29 shows an example of a lo w-to-high transition on an input that has its filter set to 125 ns (N = 5). Figure 7-29. Filter Example Enabling filters introduces jitter on the in[...]
-
Pagina 108
Chapter 7 Counters © National Instruments Corporation 7-35 NI 6232/6233 User Manual prescaling on each counter (prescaling can be disabled). Each prescaler consists of a small, simple counter th at counts to eight (or two) and rolls ov er . This counter can run faster than the lar ger counters, which simply count the rollovers of this smaller coun[...]
-
Pagina 109
Chapter 7 Counters NI 6232/6233 User Manual 7-36 ni.com Figure 7-31. Duplicate Count Pr evention Example On the first rising edge of the G ate, the current count of 7 is stored. On the next rising edge of the Gate, the counter stores a 2 since two Source pulses occurred after the pre vious rising edge of Gate. The counter synchronizes or samples th[...]
-
Pagina 110
Chapter 7 Counters © National Instruments Corporation 7-37 NI 6232/6233 User Manual Figure 7-32. Duplicate Count Example Example Application That Pr events Duplicate Count W ith duplicate count prevention enabled, the counter synchronizes both th e Source and Gate signals to the 80 MHz T imeb ase. By synchronizing to the timebase, the counter dete[...]
-
Pagina 111
Chapter 7 Counters NI 6232/6233 User Manual 7-38 ni.com Normally , the counter value and Counter n Internal Output signals change synchronously to the Source signal. W ith duplicate count prev ention, the counter value and Counter n Internal Output signals change synchronously to the 80 MHz T i mebase. Note that duplicat e count prev ention should [...]
-
Pagina 112
Chapter 7 Counters © National Instruments Corporation 7-39 NI 6232/6233 User Manual In D A Qmx, the device uses 80 MHz sour ce mode if the user performs the following: • Performs a position measurement • Selects duplicate count prev ention Otherwise, the mode depends on the signal that drives Counter n Source. T able 7-6 describes the conditi [...]
-
Pagina 113
Chapter 7 Counters NI 6232/6233 User Manual 7-40 ni.com Other Internal Source Mode In other internal source mode, the de vice synchronizes signals on the falling edge of the source, and counts on the following rising edge of the source, as shown in Figure 7-35. Figure 7-35. Other Internal Sour ce Mode External Source Mode In external source mode, t[...]
-
Pagina 114
© National Instruments Corporatio n 8-1 NI 6232/6233 User Manual 8 PFI NI 6232/6233 devices ha ve 10 Programmable Function Interface (PFI) signals—six input si gnals and four outpu t signals. Each PFI <0..5>/P0.<0..5> can be configured as a timing input signal for AI or counter/timer functions or a st atic digital input. Each PFI inp[...]
-
Pagina 115
Chapter 8 PFI NI 6232/6233 User Manual 8-2 ni.com Figure 8-2. NI 6232/6233 PFI Output Circuitry When a terminal is used as a timing input or output signal, it is called PFI x (where x is an integer from 0 to 9). When a terminal is used as a static digital input or outp ut, it is called P 0. x or P1. x . The voltage input and output le vels and the [...]
-
Pagina 116
Chapter 8 PFI © National Instruments Corporatio n 8-3 NI 6232/6233 User Manual Exporting T iming Output Signals Using PFI T erminals Y ou can ro ute any of the follo wing timing signals to any PFI <6..9> terminal. • AI Hold Co mplete Ev ent • Counter n Source • Counter n Gate • Counter n Internal Output •F r e q u e n c y O u t p u[...]
-
Pagina 117
Chapter 8 PFI NI 6232/6233 User Manual 8-4 ni.com Figure 8-3. PFI Inpu t Signa ls Connections PFI Filters Y ou can enable a programmable debouncing filter on each PFI, R TSI, or PXI_ST AR signal. When th e filters are enabled, your de vice samples the input on each rising edge of a filter clock. M Series de vices use an o nboard oscillator to gener[...]
-
Pagina 118
Chapter 8 PFI © National Instruments Corporatio n 8-5 NI 6232/6233 User Manual The filter setting for each input can be conf igured independently . On power up, the filters are dis abled. Figure 8- 4 sho ws an example of a lo w-to-high transition on an input that has its filter set to 125 ns (N = 5). Figure 8-4. Filter Example Enabling filters int[...]
-
Pagina 119
Chapter 8 PFI NI 6232/6233 User Manual 8-6 ni.com Consult the device specifi cations for details. Howe ver, you should avoid these fault conditions b y follo wing these guidelines. •D o not connect any digital output line to any external signal source, ground signal, or power supply . • Understand the current requirement s of the load connected[...]
-
Pagina 120
Chapter 8 PFI © National Instruments Corporatio n 8-7 NI 6232/6233 User Manual Figure 8-5. NI 623 2 Digital I/O Connections (DO Source) P1.<0..3> P1.VCC P1.0 P1.1 P1.GND P0.0 P0.GND P1.GND P0.GND Digital Isolators[...]
-
Pagina 121
Chapter 8 PFI NI 6232/6233 User Manual 8-8 ni.com Figure 8-6. NI 6233 Digital I/O Co nnections (DO Sink) Caution Exceeding the maximum input voltage or maximum working v oltage ratings, which are listed in the NI 6232/6233 Specifications , can damage the D A Q device and the computer . NI is not liable for an y damage resulting from such signal con[...]
-
Pagina 122
© National Instruments Corporatio n 9-1 NI 6232/6233 User Manual 9 Isolation and Digital Isolators NI 6232/6233 devices are isolated data acquisition devices. As sho wn in Figure 9-1, the analog input, analog output, counter s, and PFI/static DIO circuitry are referenced to an isolated gr ound . The bus interface circuitry , R TSI, digital routing[...]
-
Pagina 123
Chapter 9 Isolation and Digital Isolators NI 6232/6233 User Manual 9-2 ni.com The non-isolated ground is connected to the chassis groun d of the PC or chassis where the device is installed. The isolated ground is not connected to the chassis ground of the PC or chassis. The isolated ground can be at a higher or lower v oltage relative to the non-is[...]
-
Pagina 124
© National Instruments Corporation 10-1 NI 6232/6233 User Manual 10 Digital Routing and Clock Generation The digital routing circuitr y has the following three main functions. • Manages the flow of data be tween the b us interface and the acquisition/generat ion sub-systems (analog inpu t, analog output, digital I/O, and the counters). The digit[...]
-
Pagina 125
Chapter 10 Digital Ro uting and Clock Generation NI 6232/623 3 User Manu al 10- 2 ni.com 80 MHz Timebase The 80 MHz T imebase can be used as the Source input to the 32-bit general-purpose counter/timers. The 80 MHz T ime base can be generated from either of the following. • Onboard oscillat or • External signal (by using the external reference [...]
-
Pagina 126
Chapter 10 Digital Routing and Clock Generati on © National Instruments Corporation 10-3 NI 6232/6233 User Manual 10 MHz Reference Clock The 10 MHz reference clock can be used to synchronize other devices to your M Series de vice. The 10 MHz refere nce clock can be routed to the R TSI <0..7> terminals. Other devices connected to the R TSI bu[...]
-
Pagina 127
Chapter 10 Digital Ro uting and Clock Generation NI 6232/623 3 User Manu al 10- 4 ni.com • Share trigger signals between devices Many National Instruments D A Q, motion, vision, and CAN devices support R TSI. In a PCI system, the R TSI bus consists of the R TSI b us interface and a ribbon cable. The bus can route timing and trigg er signals betwe[...]
-
Pagina 128
Chapter 10 Digital Routing and Clock Generati on © National Instruments Corporation 10-5 NI 6232/6233 User Manual Using R TSI as Outputs R TSI <0..7> are bidirectional ter minals. As an output, you can d riv e any of the following signals to any R TSI term inal. • ai/StartTrigger • ai/ReferenceT rigger • ai/Con vertClock* • ai/Sample[...]
-
Pagina 129
Chapter 10 Digital Ro uting and Clock Generation NI 6232/623 3 User Manu al 10- 6 ni.com Using R TSI T erminals as T iming Input Signals Y ou can use R TSI terminals to route external timing signals to many different M S eries functions. Each R TSI terminal can be routed to any of the following signals. • AI Con vert Clock • AI Sample Clock •[...]
-
Pagina 130
Chapter 10 Digital Routing and Clock Generati on © National Instruments Corporation 10-7 NI 6232/6233 User Manual The filter setting for each input can be conf igured independently . On power up, the filters are disabl ed. Figure 10 -3 shows an e xample of a low-to-high transition on an input that has its filter set to 125 ns (N = 5). Figure 10-3.[...]
-
Pagina 131
Chapter 10 Digital Ro uting and Clock Generation NI 6232/623 3 User Manu al 10- 8 ni.com PXI Clock and T rigger Signals Note PXI clock and trigger signals are only av ailable on PX I devices. Other de vices use RT S I . PXI_CLK10 PXI_CLK10 is a common low-sk e w 10 MHz clock reference clock for synchronization of multiple modu les in a PXI measurem[...]
-
Pagina 132
Chapter 10 Digital Routing and Clock Generati on © National Instruments Corporation 10-9 NI 6232/6233 User Manual An M Series device is not a Star T r igger controller . An M Series device may be used in the first peripheral slot of a PXI system, but the system will not be able to use th e Star Trigger feature. PXI_ST AR Filters Y ou can enable a [...]
-
Pagina 133
Chapter 10 Digital Ro uting and Clock Generation NI 6232/6233 User Manual 10-10 ni.com Figure 10-4. Filter Example Enabling filters introduces jitter on the input signal. For the 125 ns and 6.425 µs filter settings, the jitter is up to 25 ns. On the 2.55 ms settin g, the jitter is up to 10.025 µs. When a PFI input i s routed directly to R TSI, or[...]
-
Pagina 134
© National Instruments Corporation 11-1 NI 6232/6233 User Manual 11 Bus Interface The bus interf ace circuitry of NI 6232/6 233 devices ef ficiently mov es data between host memory and the meas urement and acquisition circuits. NI 6232/6233 devices are a vailable for the following platforms. •P C I •P X I NI 6232/6233 devices are jumperless fo[...]
-
Pagina 135
Chapter 11 Bus Interface NI 6232/623 3 User Manu al 11- 2 ni.com Each DMA controller supports packing and unpacking of data through the FIFOs to connect different size de vi ces and optimize PCI bus utilization and automatically handles unalig ned memory buf fers. PXI Considerations Note PXI clock and trigger signals are only av ailable on PX I dev[...]
-
Pagina 136
Chapter 11 Bus Interface © National Instruments Corporation 11-3 NI 6232/6233 User Manual Using PXI with CompactPCI Using PXI-compatib le products with st andard CompactPCI products is an important feature provided by PXI Har dware Specif ication Revision 2.1 . If you use a PXI-comp atible plug-in mod ule in a standard CompactPCI chassis, you cann[...]
-
Pagina 137
Chapter 11 Bus Interface NI 6232/623 3 User Manu al 11- 4 ni.com Interrupt Request (IRQ) IRQ transfers rely on the CPU to service data transfer requests. The device notifies the CPU when it is ready to tr ansfer data. The data transfer speed is tightly coupled to the rat e at which the CPU can service the inter rupt requests. If you are using inter[...]
-
Pagina 138
© National Instruments Corporation 12-1 NI 6232/6233 User Manual 12 T riggering A trigger is a signal that caus es an action, such as starting or stopping the acquisition of data. When you configure a trigger , you must decide how you want to produce the trigger and the action you want the trigger to cause. NI 6232/6233 devices support internal so[...]
-
Pagina 139
Chapter 12 T riggering NI 6232/623 3 User Manu al 12- 2 ni.com • Analog output generat ion • Counter be havior[...]
-
Pagina 140
© National Instruments Corporation A-1 NI 6232/6233 User Manual A Device-Specific Information This appendix contains device pinout s, specif ications, cable and accessory choices, and other information for the NI 6232 and NI 6233 MS e r i e s isolated devices. T o o btain documentation for devices not listed h ere, refer to ni.com/manuals . NI 623[...]
-
Pagina 141
Appendix A Device-Speci fic Information NI 6232/6233 User Manual A- 2 ni.com Figure A-1. NI 6232 Pin out Table A-1. NI 6232 Device Default NI-D AQmx Counter/T imer Pins Counter/Timer Signal Default Pin N umber (Name) Por t CTR 0 SRC 13 (PFI 0) P0.0 CTR 0 GA TE 32 (PFI 1) P0.1 CTR 0 A UX 33 (PFI 2) P0.2 CTR 0 OUT 17 (PFI 6) P1.0 CTR 0 A 13 (PFI 0) P[...]
-
Pagina 142
Appendix A Device-Specific Information © National Instruments Corporation A-3 NI 6232/6233 User Manual Note For more information abou t default NI-D A Qmx counter inputs, refer to Connecting Counter Signals in the NI-DA Qmx Help or the LabVIEW 8.x Help . NI 6232 Specifications Refer to the NI 6232/6233 Specifications , av ailable on the NI-D A Q D[...]
-
Pagina 143
Appendix A Device-Speci fic Information NI 6232/6233 User Manual A- 4 ni.com vision, and motion devices. Since PXI devices use PXI backplane signals for timing an d synchronization, no cables are required. Cables In most applications, you can use the following cables: • SH37F-37M- x —37-pi n female-to-male shield ed I/O cable, UL Listed derated[...]
-
Pagina 144
Appendix A Device-Specific Information © National Instruments Corporation A-5 NI 6232/6233 User Manual Figure A-2. NI 6233 Pinout Table A-2. NI 6233 Device Default NI-D AQmx Counter/T imer Pins Counter/Timer Signal Default Pin N umber (Name) Por t CTR 0 SRC 13 (PFI 0) P0.0 CTR 0 GA TE 32 (PFI 1) P0.1 CTR 0 A UX 33 (PFI 2) P0.2 CTR 0 OUT 17 (PFI 6)[...]
-
Pagina 145
Appendix A Device-Speci fic Information NI 6232/6233 User Manual A- 6 ni.com Note For more information abou t default NI-D A Qmx counter inputs, refer to Connecting Counter Signals in the NI-DA Qmx Help or the LabVIEW 8.x Help . NI 6233 Specifications Refer to the NI 6233 Specifications , av ailable on the NI-D A Q De vice Document Br o wser or ni.[...]
-
Pagina 146
Appendix A Device-Specific Information © National Instruments Corporation A-7 NI 6232/6233 User Manual vision, and motion devices. Since PXI devices use PXI backplane signals for timing an d synchronization, no cables are required. Cables In most applications, you can use the following cables: • SH37F-37M- x —37-pi n female-to-male shield ed I[...]
-
Pagina 147
© National Instruments Corporation B-1 NI 6232/6233 User Manual B T roubleshooting This section contains some common questions about M Series de vices. If your questions are not answered here, refer to the National Instrum ents KnowledgeBase at ni.com/kb . It contains thousands of documents that answer frequently asked questions about NI products.[...]
-
Pagina 148
Appendix B T roubleshooting NI 6232/6233 User Manual B- 2 ni.com reference the signal to the same ground le vel as the de vice reference. There are various methods of achie ving this reference while maintai ning a high common-mode rejectio n ratio (CMRR). These methods are outlined in th e Connecting Analo g Voltage Input Signals section of Chapter[...]
-
Pagina 149
Appendix B T roubleshooting © National Instruments Corporation B-3 NI 6232/6233 User Manual Analog Output I am seeing glitches on the outp ut signal. Ho w can I minimize it? When you use a D AC to gene rate a wa veform, you may o bserve glitches on the output signal. These glitches are normal; when a DA C switches from one voltage to another , it [...]
-
Pagina 150
© National Instruments Corporation C-1 NI 6232/6233 User Manual C T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources at ni.com/support include the following: – Self-Help Resour[...]
-
Pagina 151
Appendix C T echnical Support and Professional Services NI 6232/6233 User Manual C- 2 ni.com • Calibration Certificate —If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration . If you searched ni.com and could not find the answers you need, contact your local off ice or NI corpora[...]
-
Pagina 152
© National Instruments Corporation G-1 NI 6232/6233 User Manual Glossar y Numbers/Symbols % Percent. + Positiv e of, or plus. – Negati ve of, or minus. ± Plus or minus. < Less than. > Greater than. Less than or equal to. Greater than or equal to. /P e r . º Degree. Ω Ohm. A A Amperes—the unit of electric current. A/D Analog-to-Digital[...]
-
Pagina 153
Glossary NI 6232/6233 User Manual G-2 ni.com AI 1. Analog input. 2. Analog input channel signal. AI GND Analog input groun d signal. AI SENSE Analog input sense signal. analog A signal whose amplitu de can hav e a conti nuous range of v alues. analog input signal An input signal that varies smoothly ov er a continuous range of values, rather than i[...]
-
Pagina 154
Glossary © National Instruments Corporation G-3 NI 6232/6233 User Manual ASIC Application-specific integrated circuit—A proprietary semiconductor component designed and manufactur ed to perform a set of specific functions for a specif ic customer . asynchronous 1. Hardware—A property of an ev ent that occurs at an arbitrary time, without synch[...]
-
Pagina 155
Glossary NI 6232/6233 User Manual G-4 ni.com cascading Process of extending the counting ra nge of a counter chip by connecting to the next higher counter . CE European emissions control standard. channel Pin or wire lead to which you apply or from which you read the analog or digital si gnal. Analog sign als can be single-ended or dif ferential. F[...]
-
Pagina 156
Glossary © National Instruments Corporation G-5 NI 6232/62 33 User Manual counter/timer A circuit that counts external pulses or clock pulses (timing). D D GND Digital grou nd signal. D-SUB connector A serial connector . D AC Digital-to-Ana log Con verter—An elect ronic device, often an inte grated circuit, that con verts a digital number into a[...]
-
Pagina 157
Glossary NI 6232/6233 User Manual G-6 ni.com data transfer A technique for moving digital data from one system to another . Options for data transfer are DMA, interrupt, and programmed I/O. For programmed I/O transfers, the CPU in the PC reads data from the D A Q device whenev er the CPU receives a soft ware signal to ac quire a single data point. [...]
-
Pagina 158
Glossary © National Instruments Corporation G-7 NI 6232/6233 User Manual digital signal A representation of information by a set of discrete v alues according to a prescribed law . These values are represented by numbers. digital trigger A TTL lev el signal having two discrete le vels—a high and a low le vel. DIO Digital input/ou tput. DMA Direc[...]
-
Pagina 159
Glossary NI 6232/6233 User Manual G-8 ni.com F FIFO First-In-F irst-Out memory buffer—A data b uffering technique that functions like a shift register where the oldest values (f irst in) come out first. Many D A Q products and instruments use FIFOs to buf fer digital data from an A/D con verter , or to buf f er the data before or after bus transm[...]
-
Pagina 160
Glossary © National Instruments Corporation G-9 NI 6232/62 33 User Manual function 1. A built-in e xecution element, co mparable to an operator , function, or statement in a con v entional language. 2. A set of software i nstructions executed b y a single line of code that may hav e input and/or output parameters and returns a value when ex ecuted[...]
-
Pagina 161
Glossary NI 6232/6233 User Manual G-10 ni.com in. Inch or inches. instrument driv er A set of high-le vel software functions that controls a specif ic GPIB, VXI, or RS232 programmable instrument or a specific plug-in D A Q device. Instrument d riv ers are av ailab le in several forms, ranging from a function callable language to a virtual instrum e[...]
-
Pagina 162
Glossary © National Instruments Corporation G-11 NI 6232/6233 User Manual K kHz K ilohertz—A unit o f frequency; 1 kHz = 10 3 = 1,000 Hz. kS 1,000 samples. L LabVIEW A graphical programming language. LED Light-Emitting Di ode—A semicondu ctor light source. lowpass filter A filter that passes signals below a cutof f frequency while blocking sig[...]
-
Pagina 163
Glossary NI 6232/6233 User Manual G-12 ni.com MITE MXI Interface T o Everything—A custom ASIC designed b y National Instruments that implements the PCI bu s interf ace. The MITE supports bus mastering for high-speed dat a transfers ov er the PCI bus. module A board assembly and its associated mechanical pa rts, front panel, op tional shields, and[...]
-
Pagina 164
Glossary © National Instruments Corporation G-13 NI 6232/6233 User Manual NI-PGIA See instrumentation am plifier . non-referenced signal sources Signal sources with voltage signals t hat are not connected to an absolute reference or system ground. Also called floatin g signal sources. Some common example of non-referenced signal sources are batter[...]
-
Pagina 165
Glossary NI 6232/6233 User Manual G-14 ni.com power source An in strument that provides one or more sources of A C or DC power . Also known as po wer supply . ppm Parts per million. pretriggering The technique used on a D A Q device to keep a continuous b uf fer filled with data, so that when the trigger conditi ons are met, the sample includes the[...]
-
Pagina 166
Glossary © National Instruments Corporation G-15 NI 6232/6233 User Manual R range The maximum and minimum parameters between whi ch a sensor , instrument, or device operates with a specified set of ch aracteristics. This may be a voltage range or a frequency range. real time 1. Displays as it comes in; no delays. 2. A prop erty of an ev ent or sys[...]
-
Pagina 167
Glossary NI 6232/6233 User Manual G-16 ni.com scan rate Reciprocal of the scan interval. SCC Signal Conditioning Carriers—A comp act, modular form factor for signal conditioning modul es. SCXI Si gnal Condition ing eXtensions for Instru mentation—Th e National Instruments pr oduct line for condit ioning low-le vel signals with in an external ch[...]
-
Pagina 168
Glossary © National Instruments Corporatio n G-17 NI 6232/6233 User Manual software applications The programs that run on your computer and perform a specific user- oriented function, such as acco unting, program de velopment, measurement, or data acquisition. In contrast, o perating system fun ctions basically perform the generic "housek eep[...]
-
Pagina 169
Glossary NI 6232/6233 User Manual G-18 ni.com t out Output delay time. transducer A de vice that responds to a physical stimulu s (heat, light, sound, pressure, motion, flow , and so on), and produces a corresponding electrical signal. See also sensor . trigger 1. Any e vent that causes or starts some form of data capture. 2. An external stimulus t[...]
-
Pagina 170
Glossary © National Instruments Corporation G-19 NI 6232/6233 User Manual V m Measured voltage. V OH V olts, output high. V OL V olts, output low . V out V olts out. V s Signal source voltage. virtual channel See channel . W wa veform 1. The plot of the instantaneous ampl itude of a signal as a function of time. 2. Multipl e voltage readings taken[...]
-
Pagina 171
© National Instruments Corporatio n I-1 NI 6232/6233 User Manual Index Symbols .NET languages documentatio n, xviii Numerics 10 MHz reference clock, 10-3 100 kHz Timebase, 10-2 20 MHz T im ebase, 10-2 80 MHz source mode, 7-39 80 MHz T im ebase, 10-2 A A/D con verter, 4-2 accessories, 2-4, A-3, A-6 choosing for your device, 1-2 acquisition circular[...]
-
Pagina 172
Index NI 6232/6233 User Manual I-2 ni.com getting started with applications in software, 5-10 glitches on the output si gnal, 5-2 signals, 5-5 timing signals, 5-5 trigger signals, 5-4 triggering, 5-4 troubleshooting, B-3 ANSI C documentation, xviii A O FIFO, 5-1 A O Pause T rigger signal, 5-7 A O Sample Clock signal , 5-8 A O Sample Clock Timebase [...]
-
Pagina 173
Index © National Instruments Corporatio n I-3 NI 6232/6233 User Manual for ground-ref erenced signal sources, 4-14 for non-referenced signal sources, 4-15 single-ended considerations, 4-16 single-ended for floating signal sources, 4-17 single-ended for grounded signal sources, 4-17 single-ended, NRSE configuration, 4-16 single-ended, RSE configura[...]
-
Pagina 174
Index NI 6232/6233 User Manual I-4 ni.com data transfer methods, 11-3 changing, 11-4 DMA, 11-3 IRQ, 11-4 programmed I/O, 11-4 Declaration of Conformity (NI resources), C-1 default counter terminals, 7-31 device cabling, 2-4 information, A-1 multiple synchronization, 10-3 specifications, 1-2 diagnostic tools (NI resources), C-1 differential analog i[...]
-
Pagina 175
Index © National Instruments Corporatio n I-5 NI 6232/6233 User Manual F features, counter, 7-33 field wiring considerations, 4-18 fil t e r s counter, 7-33 PFI, 8-4 PXI_ST A R, 10-9 RT S I , 1 0 - 6 floating signal sources, 4-13 FREQ OUT signal, 7-31 frequency division, 7-25 generation, 7-24 generator, 7-24 measurement, 7-10 Frequency Output sign[...]
-
Pagina 176
Index NI 6232/6233 User Manual I-6 ni.com isolation barrier, 4-2, 5-2 isolators, 9-1 K Kno wledgeBase, C-1 L LabVIEW documentation, xvii LabW indows/CVI documentation, xviii lo w impedance sources, 4-6 M M Series information, A-1 specifications, xix Measurement Studio documentation, xviii measurements buf fered period , 7-8 buf fered pu lse-width, [...]
-
Pagina 177
Index © National Instruments Corporatio n I-7 NI 6232/6233 User Manual non-buf fered hardware-timed acquisitions, 4-11 generations, 5-3 non-cumulative buf fered edge counting, 7-5 non-referenced signal so urces, dif ferential connections, 4-15 NRSE conf iguration, 4-16 O order of channels for scanning, 4-7 other internal source mode, 7-40 other so[...]
-
Pagina 178
Index NI 6232/6233 User Manual I-8 ni.com retriggerable single pu lse generation, 7-22 routing clock, 10-1 digital, 10-1 RSE configuration, 4-16 RT S I , 1 0 - 3 connector pinout, 3-3, 10-4 fil t e r s, 1 0 - 6 using as outputs, 10-5 using terminals as timing i nput signals, 10-6 S sample clock edge counting, 7-4 scanning speed, 4-9 semi-period mea[...]
-
Pagina 179
Index © National Instruments Corporatio n I-9 NI 6232/6233 User Manual connections, NRSE co nfiguration, 4-16 connections, RSE configuration, 4-16 software configuring AI ground-reference settings, 4-5 NI resources, C-1 programming devices, 2-5 timed acquisitions, 4-9 software-timed acquisitions, 4-9 generations, 5-2 specifications, A-3, A-6 devic[...]
-
Pagina 180
Index NI 6232/6233 User Manual I- 10 ni.com V vol t a ge connecting analog in put signals, 4-11 connecting analog voltage, 5-4 W wa veform generation signals, 5-5 W eb resources, C-1 wiring, field, 4-18 X X1 encoding, 7-16 X2 encoding, 7-17 X4 encoding, 7-17[...]