National Instruments NI 9853 manuale d’uso
- Visualizza on-line o scarica il manuale
- 28 pagine
- 0.33 mb
Vai alla pagina of
Manuali d’uso simili
-
Network Card
National Instruments PC-DIO-24
75 pagine 1.26 mb -
Network Card
National Instruments CFP-2220
38 pagine 4.73 mb -
Network Card
National Instruments VXI-1394
74 pagine 0.65 mb -
Network Card
National Instruments NI PCIe-8255R
16 pagine 0.27 mb -
Network Card
National Instruments TPC-2012
49 pagine 0.65 mb -
Network Card
National Instruments Gigabit Ethernet Adapters
17 pagine 0.96 mb -
Network Card
National Instruments PXI Terminal Block NI TB-2708
12 pagine 0.87 mb -
Network Card
National Instruments USB Digitizers NI USB-5132
9 pagine 0.46 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso National Instruments NI 9853. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica National Instruments NI 9853 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso National Instruments NI 9853 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso National Instruments NI 9853 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo National Instruments NI 9853
- nome del fabbricante e anno di fabbricazione National Instruments NI 9853
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature National Instruments NI 9853
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio National Instruments NI 9853 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti National Instruments NI 9853 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio National Instruments in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche National Instruments NI 9853, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo National Instruments NI 9853, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso National Instruments NI 9853. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
OPERATING INSTRUCTIONS NI 9853 2-Port, High-Speed CAN Module[...]
-
Pagina 2
NI 9853 Operating Instructions 2 ni.com These operating instructions desc ribe ho w to use the Natio nal Instruments (NI) 9853 module. F o r information about installing, configuring, and programming your system, refer to your system documentation. The NI 9853 module requires the NI 9853 software to be installed. The latest version of the NI 985 3 [...]
-
Pagina 3
© National Instruments Corp. 3 NI 9853 Operating Instructions Safety Guidelines fo r Hazardous Loca tions The NI 9853 is suitable for use in Cl ass I, Division 2, Groups A, B, C, D, T4 hazardous locations; Clas s I, Zone 2, AEx nA II T4 and Ex nA II T4 hazardous locations ; and nonhazardous locations only . Follo w these guidelines if you ar e ins[...]
-
Pagina 4
NI 9853 Operating Instructions 4 ni.com Caution For Zone 2 applications, install a protection device between the CAN signals and the NI 9853 CAN pins. The de vice must pre v ent the CAN Port-to-COM voltage from e xceeding 55 V if there is a transient ov ervoltage condition. Special Conditions fo r Safe Use in Europe This equipment has been evalua t[...]
-
Pagina 5
© National Instruments Corp. 5 NI 9853 Operating Instructions one or both of the COM pins. Each port also has an o ptional shield pin, SHLD, that can be connect ed to a shielded CAN cable. Connecting SHLD may impro ve signa l integrity and EMC performance in a noisy en vironment. CAN0 of the NI 9853 is internally po wered, and therefore requires n[...]
-
Pagina 6
NI 9853 Operating Instructions 6 ni.com Table 1. Pin Assignments for CAN0 Connector Pin Signal 1 No Connection (NC) 2 CAN_L 3 COM 4 NC 5 SHLD 6 COM 7 CAN_H 8 NC 9 NC 6 7 8 9 1 2 3 4 5[...]
-
Pagina 7
© National Instruments Corp. 7 NI 9853 Operating Instructions Table 2. Pin Assignments for CAN1 Connector Pin Signal 1 No Connection (NC) 2 CAN_L 3 COM 4 NC 5 SHLD 6 COM 7 CAN_H 8 NC 9 V SUP 6 7 8 9 1 2 3 4 5[...]
-
Pagina 8
NI 9853 Operating Instructions 8 ni.com CAN Bus T opology and T e rmination A CAN bus consists of two or more CAN nodes cabled together . The CAN_H and CAN_L pins of each node are connected to the main CAN bus cable through a short con nection kno wn as a “stub . ” The pair of signal wires, CAN_H and CAN_L constitutes a transmission line. If th[...]
-
Pagina 9
© National Instruments Corp. 9 NI 9853 Operating Instructions Figure 1. CAN Bus T opology and T ermination Resistor Locati ons CAN Node CAN Node CAN Node R t R t CAN Node CAN_H CAN_L CAN_H CAN_L CAN_H CAN_L CAN_H CAN_L Bus Cable Length Stub Length[...]
-
Pagina 10
NI 9853 Operating Instructions 10 ni.com Connecting a CAN Bus to the NI 9853 Each port of the NI 9853 can be connected to any location on a CAN bus. Figure 2 shows one exam ple of the con nection of CAN0 of the NI 9853 directly to one C AN node, and CAN1 directly to another CAN node. CAN1 requires an external power sup ply on the CAN bus.[...]
-
Pagina 11
© National Instruments Corp. 11 NI 9853 Operating Instructions Figure 2. Connecting Both Ports of th e NI 9853 to CAN Buses CAN1 CAN Device CAN0 NI 9853 R t CAN Cable (With Optional Shield) (SHLD) CAN_H CAN_L V sup COM R t (SHLD) CAN_H CAN_L V sup COM CAN Device R t CAN Cable (With Optional Shield) (SHLD) CAN_H CAN_L V sup COM R t (SHLD) CAN_H CAN[...]
-
Pagina 12
NI 9853 Operating Instructions 12 ni.com Cabling Requirements for NI 9853 This section deals wi th cabling specif icatio ns, termination resistors, cable lengths, and the number of CAN nodes that can exist in a system. Cable Specifications Cables should meet th e physical medium re quirements specified in ISO 11898, sho wn in T able 3. Beld en cabl[...]
-
Pagina 13
© National Instruments Corp. 13 NI 9853 Operating Instructions T ermination Resistors The termination resistors (R t ) should match the nominal impedance of the CAN cable, and therefore comply wit h the v alues in T able 4. Cable Lengths The allo wabl e cable length is af fected by the chara cteristics of the cabling and the desired bit transmis s[...]
-
Pagina 14
NI 9853 Operating Instructions 14 ni.com Number of CAN Nodes The maximum number of nodes depends on the electrical characteristics of the nodes on the ne twor k. If all of the nodes meet the requirements of ISO 11898, at least 30 nodes may be connected to the bus. Higher numbers of nodes may be connected if the electrical characteristics of th e no[...]
-
Pagina 15
© National Instruments Corp. 15 NI 9853 Operating Instructions Figure 3. NI 9853 Hardware Overview Rx Tx CAN T r ansceiver +5 V_ISO +5 V GND COM CAN_H CAN_L +5 V Reg Rx Tx Ext Pwr Supply CAN Controller Rx Tx CAN Controller CAN_H CAN_L CAN T r ansceiver Rx Tx COM V sup CAN0 CAN1 + _ Iso Pwr[...]
-
Pagina 16
NI 9853 Operating Instructions 16 ni.com Sleep Mode (CompactRIO Only) Y ou can enable sleep mode fo r the CompactRIO system in software. In sleep mode, the syst em consumes less power and may dissipate less heat. T ypically , when a system is in sleep mode, you cannot communicate with th e modules. Refer to the Spec ifications section for more info[...]
-
Pagina 17
© National Instruments Corp. 17 NI 9853 Operating Instructions Specifications The follo wing spec ificat ions are typical for the range – 40 to 70 °C unless otherwise noted. High-Speed CAN Characteristics T ransceiv er .......... ........... ........... ........ Philips TJ A 1041 Max baud rate ............ ........... ........... . 1 Mbps CAN_H[...]
-
Pagina 18
NI 9853 Operating Instructions 18 ni.com Power Requirements Power consumption from chassis Activ e mode T ransmitting ............. ............ 625 mW max Receiving ........ ........... .......... 400 mW max Sleep mode . ......... ........... ......... ... 25 μ W max Thermal dissipation (at 70 °C) Active mode ........ ......... ........... ... 1[...]
-
Pagina 19
© National Instruments Corp. 19 NI 9853 Operating Instructions Safety Maximum Voltage 1 Connect only v oltages that are wi thin these limits. Port-to-COM ....... ...................... ........ –27 to +40 VDC max, Measurement Category I Measurement Cate gory I is f or measurements performed on circuits not directly connected to the electrical di[...]
-
Pagina 20
NI 9853 Operating Instructions 20 ni.com Isolation Voltages Port-to-port W ithstand .......... ............ ......... ..... 500 V rms , ver ifie d by a dielectric withstand test, 5 s Continuous .......... ......... ........... ... 60 VDC, Measurement Category I Port-to-earth ground W ithstand .......... ............ ......... ..... 500 V rms , ver [...]
-
Pagina 21
© National Instruments Corp. 21 NI 9853 Operating Instructions Note For UL and other safety certif ications, refer to the product label, or vi sit ni.com/certification , search by model number or pro duct line, and click the appropriate link in the Certification column. Hazardous Locations U.S. (UL) ............ ......... ........... .......... Cl[...]
-
Pagina 22
NI 9853 Operating Instructions 22 ni.com Environmental CompactRIO mod ules are inte nded for indoor u se only . F or outdoor use, mount the CompactRIO system in a suitably rated enclosure. Refer to the installa tion instructions for the chassis you are using for more information a bout meeting these specif ications. Operating temperature ..........[...]
-
Pagina 23
© National Instruments Corp. 23 NI 9853 Operating Instructions Operating shock (IEC 60068-2-27)........... ........... ........ 30 g, 11 ms half sine, 50 g, 3 ms half sine, 18 shocks at 6 orientations Operating vibration, sinusoidal (IEC 60068-2-6) .... .......... 5 g, 10 to 500 Hz Electromagnetic Compatibility This product is designed to meet the[...]
-
Pagina 24
NI 9853 Operating Instructions 24 ni.com CE Compliance This product meets the essentia l requirements of applicable European Directi ves, as amended for CE marking, as follo ws: • 2006/95/EC; Low-V oltage Directi ve (safety) • 2004/108/EC; Electromagneti c Compatibility Directive (EMC) Note Refer to the Declaration of Co nformity (DoC) for this[...]
-
Pagina 25
© National Instruments Corp. 25 NI 9853 Operating Instructions For additional en vironmental information, refer to the NI and the Environment W eb page at ni.com/environment . This page contains the en vironmental regulat ions and directi v es with which NI complies, as well as othe r en vironmental information not included in this document. Waste[...]
-
Pagina 26
NI 9853 Operating Instructions 26 ni.com National Instruments Contact Information National Instruments corporate headquarters is located at 11500 North Mopac Expressway , Austin, T exas, 78759-3504. National Instruments also has of fi ces located around the world to help address your support needs. F or telephone support in the United States, cr ea[...]
-
Pagina 27
© National Instruments Corp. 27 NI 9853 Operating Instructions South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, T aiwan 886 02 2377 2222, Thailand 662 278 6777, T urk ey 90 212 279 3031, United Kingdom 44 (0) 1635 523545[...]
-
Pagina 28
© 2006–2008 Nati onal Instruments Corp. All rights reserved. 371453D-01 Jun08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com /legal for more informat ion about National Inst ruments trademarks. Other product and company names ment ioned herein are tr[...]