Vai alla pagina of
Manuali d’uso simili
-
Hunting Equipment
Newcon Optik DN 463
32 pagine 0.86 mb -
Hunting Equipment
Newcon Optik NC 3-12X50
32 pagine 1.1 mb -
Hunting Equipment
Newcon Optik NC 20-60X80
16 pagine 0.44 mb -
Hunting Equipment
Newcon Optik LRM 220SI
32 pagine 0.91 mb -
Hunting Equipment
Newcon Optik NVS 14-3XT
32 pagine 0.87 mb -
Hunting Equipment
Newcon Optik DN310
10 pagine 0.41 mb -
Hunting Equipment
Newcon Optik 15-45X60
8 pagine 0.46 mb -
Hunting Equipment
Newcon Optik NVS 14-3AG
32 pagine 0.87 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Newcon Optik NC 3-12X50. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Newcon Optik NC 3-12X50 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Newcon Optik NC 3-12X50 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Newcon Optik NC 3-12X50 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Newcon Optik NC 3-12X50
- nome del fabbricante e anno di fabbricazione Newcon Optik NC 3-12X50
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Newcon Optik NC 3-12X50
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Newcon Optik NC 3-12X50 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Newcon Optik NC 3-12X50 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Newcon Optik in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Newcon Optik NC 3-12X50, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Newcon Optik NC 3-12X50, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Newcon Optik NC 3-12X50. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Operation Manual NC 3-12x50 DAYTIME RIFLE SCOPE 105 Sparks Ave., Toronto, ON M2H 2S5, Canada[...]
-
Pagina 2
2[...]
-
Pagina 3
3 IMPORTANT INFORMATION Read prior to activation. NC 3-12x50 is the sophisticated optical riflescope. To operate it properly, please read this manual carefully. Ignoring operation procedures described in this manual will void your warranty. NEVER disassemble the unit. NEVER reverse the polarity of a battery. NEVER connect the unit to ex[...]
-
Pagina 4
4 Precautions NC 3-12x50 is the sophisticated precise optical instrument equipped with electronics. It should be handled with due care: Unit contains fragile components. Avoid impacts, dust, moisture and sharp changes of temperature. Do not touch the optical surfaces other than for cleaning. Doing so may damage the anti- reflection coating.[...]
-
Pagina 5
5 TABLE OF CONTENTS DEVICE APPEARANCE ........................................ 6 1. BRIEF DESCRIPTION....................................... 8 2. DELIVERY SET ................................................. 9 3. TECHNICAL SPECIFICATIONS.................... 10 4. TYPE AND SIZE OF THE RETICLE.............. 11 5. INSTALLATION ON THE WEAPON .........[...]
-
Pagina 6
6 DEVICE APPEARANCE Figure 1 For numbering see the next page. The manufacturer reserves the right to implement desi gn and specification improvements from time to time without notice.[...]
-
Pagina 7
7 Figure. 1 1 - Body of the riflescope 2 - Objective lens 3 - Eyepiece 4 - Battery compartment 5 - Internal windage/elevation adjustment knobs 6 - Reticle brightness adjustment switch 7 - Parallax adjustment knob 8 - Magnification adjustment ring 9 - Objective lens cover 10 - Zeroing setscrew 11 - Fixation screws of the elevation adjustment 12 - Fi[...]
-
Pagina 8
8 1. BRIEF DESCRIPTION NC 3-12x50 is the daytime riflescope with variable magnification, which is designed for being used on various kinds of weapons. The Mil-dot reticle of the riflescope is positioned in the focal plane of the eyepiece (second focal plane), thus providing permanent size of the reticle regardless of the riflescope variable magnifi[...]
-
Pagina 9
9 2. DELIVERY SET Standard delivery set of NC 3-12 х 50 includes : - Device - 1 pc. - Objective lens cover - 1 pc. - Eyepiece cover - 1 pc. - Cleaning cloth - 1 pc. - Allen key for setting zero - 1 pc. - Battery CR2032 - 1 pc. - Manual - 1 pc. Optional accessories: - Hood - 1 pc. - Rings for installation on a weapon - 2 pc. - Hard transportation c[...]
-
Pagina 10
10 3. TECHNICAL SPECIFICATIONS Magnification, х 3 to 12 Objective lens diameter, mm 50 Field of view, º 6.8 to 1.7 (from 11.9m to 3m @100m) Exit pupil, mm 12.5 to 4.1 Diopter adjustment +3, -3 Eye relief distance, mm 100 Reticle battery, V CR 2032 (3 V) Battery life, h 15 to 100 Adjustment mechanism , step 10mm @100m Elevation range ±1.7m @100m [...]
-
Pagina 11
11 4. TYPE AND SIZE OF THE RETICLE Reticle description. The riflescope incorporates black illuminated reticle as shown on the Fig. 2. Figure 2[...]
-
Pagina 12
12 The central part of the reticle represents Mil-Dot grid with added additiona l vertical and horizontal markings in made with variable step. Such pattern corresponds to the TMR grid. The grid has breakdown for a finer step (of 0.2 thousands of a distance) on the edges. This is necessary for exact estimation of shooting distance for ranges from 50[...]
-
Pagina 13
13 Method 1. Reticle segments are described in angular units as thousands of a distance or mils (1 mil). Note 1 mil represents the angular measure of a distance and constitutes: 1 mil = 1 t.d. (one thousands of a distance), or = 10 sm at 100 m of a distance, or = 3.438*MOA (Minute of Angle). The segment E on the Fig.2 = 1 mil (=1 t.d.) is the dista[...]
-
Pagina 14
14 TABLE 3 A B C D E F G H Size in cm @100m distance 100 7.5 0.5 4.0 10 1.5 5 2 The segments of the reticle for other magnification settings are given in the Table 4 (all numbers are measured in cm @100m ). TABLE 4 Magnification, x A B C D E 3 400 28.0 2.0 10.0 40.0 4 300 21.0 1.5 7.50 30.0 6 200 14.0 1.00 5.00 20.0 8 150 10.5 0.75 3.8 15.0 10 120 [...]
-
Pagina 15
15 Example: Let's find size of the segment (E) of the thin cross hair at 100 m distance with 8 x magnification. The specified step at 100 m distance and 12x magnification is1 0cm. Now we shall calculate its size a t 8x magnification: E = (10 х 12): 8 = 15 cm at 100 m. The distance to the target also influences the corresponding sizes of the r[...]
-
Pagina 16
16 Determining distance to the target (for 12 х magnification only). By using the Mil-dot reticle and knowing the size of the target, it is possible to determine distance to the target with enough accuracy that is required to acquire the target (or make windage adjustment to compensate the bullet drop). Procedures: 1) Make sure that the riflescope[...]
-
Pagina 17
17 L= (H х 1000) / h, where L – distance to the target, m; H – real length (or height) of the target, m; h – number of the segments of the reticle that cover the chosen dimension of the target. Figure 3 (see also TABLE 6) The Figure 3 shows an example of distance estimation to a boar, which is 1.5 meters in length. Also, it is possible to de[...]
-
Pagina 18
18 TABLE 5 Distance to the target, m Real length (or height) of the target, cm Number of segments (in mils or t.d.) 30 40 50 60 70 80 90 1.00 300 400 500 600 700 800 900 1.25 240 320 400 480 560 640 720 1.50 200 267 333 400 467 533 600 1.75 171 229 286 343 400 457 514 2.0 150 200 250 300 350 400 450 2.5 120 160 200 240 280 320 360 3.0 100 133 167 2[...]
-
Pagina 19
19 TABLE 6 Distance to the target, m Real length (or height) of the target, m Number of segments (in mils or t.d.) 1.00 1.25 1.50 1.75 2.00 2.0 500 625 750 875 1000 2.5 400 500 600 700 800 3.0 333 417 500 (*) 583 667 3.5 286 357 429 500 571 4.0 250 313 375 438 500 4.5 222 278 333 389 444 5.0 200 250 300 350 400 5.5 182 227 273 318 364 6.0 167 208 2[...]
-
Pagina 20
20 5. INSTALLATION ON THE WEAPON Installation of the NC 3-12x50 on the weapon includes mounting and gluing of the fixation rings (Ø30mm) in accordance with the installation m anual of the ring manufacturer. The Ø30mm fixation rings m ust be firmly attached to the riflescope body with a two-componential epoxy glue. WARNING: Do not over tighten fix[...]
-
Pagina 21
21 The riflescope NC 3-12 х 50 can be supplied with fixation mounts for exact weapon model or without them depending on the particular order. 6. BATTERY INSTALLATION The riflescope operates with one CR2032 battery. Be sure that the battery is brand new and is installed with correct polarity (“–“sign goes inside the battery compartment). To i[...]
-
Pagina 22
22 The reticle illumination turns off automatically after 30 minutes from the last pressing of the switch. Before turning off, the reticle blinks during several seconds. In order to turn the reticle illumination off manually, it is necessary to press and hold the switch during 2 seconds. 8. USING THE NC 3-12x50 RIFLESCOPE Operating procedure: 1) Mo[...]
-
Pagina 23
23 6) If necessary, turn on the switch (6, Fig.1) to get the reticle illuminated. You should see the red illuminated outline of the reticle. Switch (6, Fig.1) also controls the reticle brightness. Riflescope is ready for operation. After operation: 1) Switch off the illumination – by returning the switch (6, Fig.1) to OFF position; 2) Close objec[...]
-
Pagina 24
24 9. ADJUSTMENT ON THE WEAPON The riflescope is equipped with tactical multi- revolving reticle adjustment mechanism . Screws of the adjustment mechanism are terminated with knobs (5, Fig.1) with the horizontal and vertical scales, which allow precise determining of the clicks and turns of the knob(s). Adjustment is performed as follows: 1) Mount [...]
-
Pagina 25
25 7) Make 3-4 single shoots, carefully and in the same manner aim ing at the target; 8) Determine grouping of shots and position of mean impact point in accordance with the shooting instructions (grouping of shots is considered normal if it falls under grouping standard for this type of weapon without a riflescope); Figure 4[...]
-
Pagina 26
26 9) Make necessary adjustments, if required, according to the pictograms shown on the windage/elevation knobs.The step of one click as shown on the knobs is 10mm at 100m distance. 10) Execute a control shot and make sure that the aiming point of the riflescope coincides with a hit point of the bullet (perform adjustments once again, if necessary)[...]
-
Pagina 27
27 10. STORAGE AND MAINTENANCE Protect the riflescope from direct impacts. If there is dirt on optical surfaces, wipe optics with clean cloth. Do not use corrosive liquids such as Acetone for riflescope cleaning (wiping with Alcohol is allowed). Long-tem storage and transportation of the riflescope should be performed in a transportation case with [...]
-
Pagina 28
28 11. TROUBLESHOOTING Unit does not focus. Rotate the eyepiece as described above in this manual. If the riflescope cannot be focused, wipe optical components with a clean optical cloth. Illumination of the reticle is not working . Make sure the battery is installed correctly and not discharged. Condensation on the riflescope. Use special anti-fog[...]
-
Pagina 29
29 12. WARRANTY NEWCON warrants this product against defect s in materi al and workmanship for one year from the date of the original purchase. Should your Newcon product prove to be defective during this period, please deliver the product securely packaged in its original container or an equivalent, along with the proof of the original purchase da[...]
-
Pagina 30
30 13. CUSTOMER SUPPORT Should you experience any difficulties with your NEWCON OPTIK product, consult the enclosed m anual. If the problem rem ains unresolved, contact our cust omer support department at (416) 663-6963 or toll free at 1- 877-368-6666. Our operating hours are 9am-5pm , Monday - Friday, Eastern Standard Ti me. At no tim e should equ[...]
-
Pagina 31
31 14. ACCEPTANCE CERTIFICATE Riflescope NC 3-12x50 The unit meets all technical specificati ons and has passed the quality assurance insp ection. Production date:________________________ Unit serial num ber: _________________________________ Quality Inspector: __________________________________ Quality Assurance Seal[...]
-
Pagina 32
NEWCON OPTIK Printed in Canada R1.T – 9.11[...]