Omega Engineering DP3300 Series manuale d’uso
- Visualizza on-line o scarica il manuale
- 28 pagine
- 3.21 mb
Vai alla pagina of
Manuali d’uso simili
-
Computer Monitor
Omega Engineering CNiTH-16D-AL
2 pagine 0.44 mb -
Computer Monitor
Omega Engineering DPi8
2 pagine 0.5 mb -
Computer Monitor
Omega Engineering LDP63100
12 pagine 0.98 mb -
Computer Monitor
Omega Engineering DP3300 Series
28 pagine 3.21 mb -
Computer Monitor
Omega Engineering DP3600
19 pagine 0.07 mb -
Computer Monitor
Omega Engineering DPS3301
26 pagine 1.91 mb -
Computer Monitor
Omega Engineering CNiTH-i32
2 pagine 0.43 mb -
Computer Monitor
Omega Engineering iLD Series
49 pagine 0.82 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Omega Engineering DP3300 Series. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Omega Engineering DP3300 Series o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Omega Engineering DP3300 Series descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Omega Engineering DP3300 Series dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Omega Engineering DP3300 Series
- nome del fabbricante e anno di fabbricazione Omega Engineering DP3300 Series
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Omega Engineering DP3300 Series
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Omega Engineering DP3300 Series non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Omega Engineering DP3300 Series e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Omega Engineering in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Omega Engineering DP3300 Series, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Omega Engineering DP3300 Series, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Omega Engineering DP3300 Series. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Programmable Dual Channel Monitor DP3300 Series User's Manual OMEGA ENGINEERING, INC., ONE OMEGA DRIVE, STAM FORD, CT 06907[...]
-
Pagina 2
DP3300 Series Us er’s Man ual Page 1 SPECIFICATIONS: ................................................................................................................ ............................................................3 DESCRIPTION:............................................................................................................[...]
-
Pagina 3
DP3300 Series Us er’s Man ual Page 2 Turning a Ch annel ON or OFF .................................................................................................... .................................................18 MODES OF OPERATION FOR A PULSE INPUT CHANNEL: .................................................................................. [...]
-
Pagina 4
DP3300 Series Us er’s Man ual Page 3 SPECIFICATIONS: (Typical @ 25C and rated supply voltage unless otherwise s pecified) STANDARD INPUTS • * 4- 20m a 10-50m a 0- 5Vdc 0-10Vdc • Thermocouple inputs: J,K,T,E,R,S,B • Cold junction compensation error: +/- 1C (10C to 40C) • Open input indication: HELP display ed • Temperature display able i[...]
-
Pagina 5
DP3300 Series Us er’s Man ual Page 4 DESCRIPTION: A hi ghly vers atile series, DP3300 off ers a uniqu e com bination of tw o an alog chan nels or tw o puls e input ch annels or a combin ation of pu lse (square w av e) on one ch annel and an analog s ignal on the other. This f eature allow s it to be u sed as counter, rat e, RPM or a frequen cy mo[...]
-
Pagina 6
DP3300 Series Us er’s Man ual Page 5 Table 1. How to Display Parameters PEAKS: A very us eful f unction on the sy st em is tracking th e high est (peak) an d the low est (v alley ) poin t attained by each chan nel. Th is is particularly h elpful if an operation is not being constantly w atched or is left unattended e.g. overn ight. DISPLAYING PEA[...]
-
Pagina 7
DP3300 Series Us er’s Man ual Page 6 RESETTING PEAKS Peaks can be reset to cu rrent process v alue e.g. if chann el 1 is reading 200 C , its peaks can be reset to 200. This w ill allow tracking from the current process reading . To reset high peak , first select th e chann el w hose peak is desired to be reset (by pushing the ‘ CH. SEL’ key).[...]
-
Pagina 8
DP3300 Series Us er’s Man ual Page 7 below the lim it (m inus th e relay) deadband. The second mode is man ual reset. Once the lim its are energ ized, they w ill stay energized un til manu ally reset. (NOTE: In the RPM mode, the rate time base m ust be sm aller than the selected filter value. If not, the system will autom atically consider the fi[...]
-
Pagina 9
DP3300 Series Us er’s Man ual Page 8 MODES OF OPERATION FOR COUNTER: COUNT UP CONFIGURATION: MODE 0: (Count up with manual reset to zero) In this m ode the s yst em cou nts up f rom zero. Preset lim its energ ize w hen the cou nt reaches presets lim it values. The un it will con tinue counting up until m anually reset. To reset the count man uall[...]
-
Pagina 10
DP3300 Series Us er’s Man ual Page 9 RESETTING COUNT: The COUNT shown for each ch annel can be reset to zero or preset for a count dow n (depending on coun ter m ode) at any time. To reset the count m anually , first select a chan nel by push ing CH SEL key and ,while ke epi ng t he CH SEL key pushed , push the RESET key sim ultan eously. The dis[...]
-
Pagina 11
DP3300 Series Us er’s Man ual Page10 the in dication of the elaps ed tim e. Maxim u m t im e indicated i s 999.59.59 hours . To reset the timing and start it all over ag ain, first push th e TIME key and w hile keeping it push ed, press the RESET key. T he time w ill res et and start ov er from 000.00.00 hours. SETUP: Setup mode provides a means [...]
-
Pagina 12
DP3300 Series Us er’s Man ual Page11 ‘Channel ON/ OFF’ Setup After display ing inpu t type, the nex t step turns a chan nel ON or OFF. This determines w hether a chan nel is scanned and displayed or not. If for any reason a chann el is not being used, it should be turned OFF. This w ill prevent the u nit from spen ding any time s canning it a[...]
-
Pagina 13
DP3300 Series Us er’s Man ual Page12 suppos e a flow transducer ou tputs a 0.130Vdc to 5.000Vdc sig nal w hich corres ponds to a flow rate of 0 to 40 gal ./min. Then to mak e the 0.130Vdc correspond to a display of 0, set OFFSET =0.130. NOTE: If the input ty p e is CURRENT, the Offset value is en tered in milliam ps. If the input ty pe is VOLTAGE[...]
-
Pagina 14
DP3300 Series Us er’s Man ual Page13 When this parameter is set for "Normally Closed", the relay is closed w hen readings are below LIMIT, and opens w hen the channel readin g exceeds its LIMIT value. The disp lay will show 'LTx N.O .' (where ‘ x’ is the chann el num ber) for a Normally Open settin g or 'LT x N.C.&apo[...]
-
Pagina 15
DP3300 Series Us er’s Man ual Page14 Display Options On pushing SETUP key w hile the display is flashin g SYS , the display briefly show s 'dSP O P t' (for displ ay opt ion) and t hen the current Display Op tio n setting. Follow ing display options are selectable. Use ^v key to step thru these options. Once th e desired Dis play Option [...]
-
Pagina 16
DP3300 Series Us er’s Man ual Page15 1. Connect a th ermocouple calibratio n source to the unit. 2. Dial in 1100 degrees cen tigrade on the calibrator (N ote: un it m ust be program me d for display ing in centig rade). 3. Adjust the gain pot (s ee diagram of rear view of inst rum ent) on the back of th e instrum ent un til the display reads &apo[...]
-
Pagina 17
DP3300 Series Us er’s Man ual Page16 SET UP Voltage or Current Setup Thermocouple / RTD / Thermister Setup Select Channel Turn Ch On/Off Select I nput Ty pe Turn Ch On/Off Select I nput Ty pe Enter Decimal Point Enter Tare Enter Proce ss Limits (1 thru 3) Enter Relay Deadban d Prog. Relay Latching / N on L atching Prog. Engineering Units Select R[...]
-
Pagina 18
DP3300 Series Us er’s Man ual Page17 SET UP Select Sy stem or Channel Progr amming For Sy stem Programing Refer to Flow Chart for Analog I nput SE LEC T INPUT TY PE 1. Voltage 2. Cu rrent 3. J T/C 4. K T/C 5. T T /C 6. E T/C 7. Pulse Turn CH On/Off Low F r e q . High Freq. RPM Counter Rate Enter Rate Time Base Select Filter Value Select Counter M[...]
-
Pagina 19
DP3300 Series Us er’s Man ual Page18 SETUP FOR A PULSE CHANNEL: Turning a Channel ON or OFF The very f irst thing af ter selecting a chan nel is to turn it on or off. A channel should be turned off if it is n o t being used . Use ^v key to select the desired setting. If a channel is OFF, the display w ill show ' CHx OFF' (where ‘x’ [...]
-
Pagina 20
DP3300 Series Us er’s Man ual Page19 FUNCTION DISPLAY SHOWS TO CHANGE active digit flash ing. active digit. Divis ion Factor 'dIV FAC' follow ed by preset Push ^v key to increment or decrem ent divis ion fact or e.g. 12 with active digit. Push <NXT> key to active digit flas hing. change activ e digit. Lim it 1 'CH1 LT1' [...]
-
Pagina 21
DP3300 Series Us er’s Man ual Page20 FUNCTION DISPLAY SHOWS TO CHANGE Latchi ng or no n - 'LATCH' for l atchi ng mode. Push ^v key to obtain alternate mode. latching relay setup. 'NON LCH' for no n latc hing mode . Lim it outpu ts prog- LT1 N.O. or LT1 N.C Use ^V key to obtain ramm ed as normally LT2 N.O. or LT2 N.C alternate [...]
-
Pagina 22
DP3300 Series Us er’s Man ual Page21 If the un it is setup as an RPM monitor then followin g steps are performed for setting u p various parameters: FUNCTION DISPLAY SHOWS TO CHANGE Filter value 1,2,4,6,10,15,20,30,60 Pus h ^v key t o obtain desired valu e Decimal poin t dP 9999 Push ^v key to placemen t dP 999.9 move decim al dP 99.99 point to d[...]
-
Pagina 23
DP3300 Series Us er’s Man ual Page22 NOTE: Pr o cess value for respective relay must be below lim it value for it to reset. Other wise th e key sequen ce will be ignore d. Open Collector (solid state) output Option: DP3300 units can be ordered with either open collector ou tputs or electro-m echanical relay s. (Check m odel num ber printed on the[...]
-
Pagina 24
DP3300 Series Us er’s Man ual Page23 FIG. 3: Power, Input/Output connections & rear view of the instrument. INPUT/OUTPUT CONNECTOR PIN ASSIGNMENTS PIN NO DESCRI PTI ON 1 CHANNEL1, L IMI T 1 NORMALL Y OPEN/OPEN COLL EC TOR NEGATIVE 2 CHANNEL1, LI MIT 1 COMMON/OPEN COL LECTOR POSITI VE 3 CHANNEL1, LI MIT 2 NORMAL LY OPEN/OPEN COLL ECTOR NEGATIV[...]
-
Pagina 25
DP3300 Series Us er’s Man ual Page24 MOUNTING 3.70” (94m m ) 4.05 ” (10 2.87 mm) 1.77” ( 4 5 mm) 0.15 ” dia . (3 . 81m m) Figure 4. Panel Cutout Dimensions 1. Cut out P anel and mount i ng hole d imensions a s shown in figure 8 ab ove . 2. Remove the nut s fr om the mounti ng sc rews on the Pa ne l Met er ( see p ictur e be low). 3. Inser[...]
-
Pagina 26
DP3300 Series Us er’s Man ual Page25 WARRANTY/DISCLAIMER[...]
-
Pagina 27
DP3300 Series Us er’s Man ual Page26[...]
-
Pagina 28
DP3300 Series Us er’s Man ual Page27[...]