Omega Speaker Systems OS550 Series manuale d’uso
- Visualizza on-line o scarica il manuale
- 77 pagine
- 3.19 mb
Vai alla pagina of
Manuali d’uso simili
-
Thermometer
Omega Speaker Systems DFG82
6 pagine 0.17 mb -
Thermometer
Omega Speaker Systems OS533E
84 pagine 3.99 mb -
Thermometer
Omega Speaker Systems OS522
72 pagine 0.34 mb -
Thermometer
Omega Speaker Systems OS520
72 pagine 0.34 mb -
Thermometer
Omega Speaker Systems HH-21A
28 pagine 0.64 mb -
Thermometer
Omega Speaker Systems OS534E
84 pagine 3.99 mb -
Thermometer
Omega Speaker Systems 0707
3 pagine 0.34 mb -
Thermometer
Omega Speaker Systems HH801A
2 pagine 0.61 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Omega Speaker Systems OS550 Series. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Omega Speaker Systems OS550 Series o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Omega Speaker Systems OS550 Series descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Omega Speaker Systems OS550 Series dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Omega Speaker Systems OS550 Series
- nome del fabbricante e anno di fabbricazione Omega Speaker Systems OS550 Series
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Omega Speaker Systems OS550 Series
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Omega Speaker Systems OS550 Series non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Omega Speaker Systems OS550 Series e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Omega Speaker Systems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Omega Speaker Systems OS550 Series, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Omega Speaker Systems OS550 Series, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Omega Speaker Systems OS550 Series. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
OS5 50/OS550-BB Series Industrial Inf r ar e d Ther m om e t er/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at[...]
-
Pagina 2
Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canada: Sa[...]
-
Pagina 3
NOTE i Unpacking Instructions Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses): OS550 or OS550-BB Series Infrared Thermometer with Sensor Head (1) RS-232 Cable with connector/adapter (OS552, OS553, OS554) only (1) CD Software ( OS552, OS553, OS554) only (1) User’s Guide ([...]
-
Pagina 4
ii OS550 Series Industrial Infrared Thermometer This page is intentionally blank[...]
-
Pagina 5
TABLE OF CONTENTS OS550/OS550-BB Series Industrial Infrared Thermometer iii Page Unpacking Instructions ...................................................................... i Chapter 1 General Description .................................................... 1-1 1.1 Introduction .....................................................................[...]
-
Pagina 6
iv TABLE OF CONTENTS OS550/OS550-BB Series Industrial Infrared Thermometer Page Chapter 4 Laser Sight Accessory ................................................... 4-1 4.1 Warnings and Cautions ...................................................................... 4-1 4.2 Description .................................................................[...]
-
Pagina 7
1-1 General Description 1 1.1 Introduction The OS550 Series Industrial Infrared (IR) Thermometers provide non-contact temperature measurement up to 2500°F (1371°C). They offer effective solutions for many non-contact temperature applications, including the following: • Predictive Maintenance: Tracking temperature shifts which indicate pending f[...]
-
Pagina 8
General Description 1 1-2 1.2 Thermometer Features The thermometer is easy to use: • Temperature readings are switchable from °F to °C via the keypad. • Parameters, such as target material emissivity and alarm setpoints, can be set and remain in memory until reset. This instrument has a rugged and functional design, including: • Sealed keyp[...]
-
Pagina 9
1-3 General Description 1 1.2.1 Display Details Figure 1-1. Display and Keypad View Table 1-2. Display Details Key Description ➀ Display Mode displays one of the following: E (Emissivity) HAL (High Alarm Setpoint) MAX (Maximum Temperature) LAL (Low Alarm Setpoint - only on OS552/OS553/OS554) MIN (Minimum Temperature) AMB (Ambient Target Temp - on[...]
-
Pagina 10
1-4 1.2.2 Parts of the Thermometer/Transmitter Figure 1-2. OS550/OS550-BB Series Industrial Infrared Thermometer Front View The display is shown in more detail in Figure 1-1 and described in Table 1-2. Note: There are no user-serviceable parts in the thermometer. Shown with optional mounting bracket, OS550-MB and mounting nut OS550-MN Sensor Head G[...]
-
Pagina 11
2-1 2 2.1 Installation 2.1.1 Sensor Head Installation The OS550’s sensor head is made of black anodized aluminum. Both ends of the sensor head come with a 1 1 ⁄ 2 - 20 standard threaded mounting connection. The sensor head is connected to the main display electronics via a 15 ' shielded cable and environmentally sealed twist lock connector[...]
-
Pagina 12
Installing the Infrared Thermometer 2 2-2 2.2 Sensor Head Dimensions Fig. 2-1. Sensor Head Dimensions 29.2 (1.15) 29.2 (1.15) 41.1 (1.62) DIA. 38.1 (1.50) DIA. 109.2 (4.30) 160.3 (6.31) 1 1 ⁄ 2 x 20 THREAD 1 1 ⁄ 2 x 20 THREAD[...]
-
Pagina 13
2-3 2.3 OS550 Display Electronics Dimensions Fig. 2-2. Main Display NEMA Housing with Mounting Brackets Dimensions Installing the Infrared Thermometer 2 131.3 (5.17) TYP . Ø 4.37 (0.172) MOUNTING HOLE (4 PLACES) 50.0 (1.97) TYP .[...]
-
Pagina 14
2-4 Installing the Infrared Thermometer 2 2.4 OS550-BB Series Display Mounting Dimensions Fig. 2-3. OEM Style Main Display with Mounting Plate 26.4 (1.04) 31.0 (1.22) 57.4 (2.26) Ø 5.16 (0.203) THRU TYP . (4 PLA CES) WILL FIT UP TO A #10 SCREW OR BOL T 118.4 (4.66) 26.4 (1.04) 57.4 (2.26) 5.1 (.20) TYP . 91.4 (3.60)[...]
-
Pagina 15
2-5 Installing the Infrared Thermometer 2 2.5 Mounting Bracket Dimensions (OS550-MB) 2.6 Mounting Nut Dimensions (OS550-MN) 50.8 (2.00) 57.2 (2.25) 38.61 Ø (1.520) 88.9 (3.50) 6.4 (.25) REF 88.9 (3.50) 12.7 (.50) 25.4 (1.00) 28.58 (1.125) 22.23 (.875) 25.4 (1.00) 3.18 R (.125) 3.18 R (.125) TYP . 2 PLACES .020 x 45 CHAMFER BOTH SIDES .020 x 45 CHA[...]
-
Pagina 16
Installing the Infrared Thermometer 2 2-6 2.7 Mounting Flange Dimensions (OS550-MF) 2.8 Air Purge Collar Dimensions (OS550-AP) 6.35 (.250) 38 (1.5) - 20 THREAD 6.35 (.250) THR U TYP . (3 PLACES) 3 HOLES ON Ø 71.1 (2.80) BOL T CIRCLE TYP . 3 PLACES 120 Ø 89 (3.5) 21.59 (.850) 1/8 N.P .T . T AP THRU 51 (2.0) DIA. 38 (1.5) – 20 THREAD Fig. 2-6 Fig[...]
-
Pagina 17
3-1 Using the Infrared Thermometer 3 3.1 Using the Infrared Thermometer 3.1.1 Water Cool Jacket Accessory When using the OS550 sensor head in an ambient temperature environment above 50°C (122°F), the OS550-WC Water Cooling Jacket option must be used to maintain the accuracy and response time of the unit. Two 1 ⁄ 8 " N.P.T. compression fit[...]
-
Pagina 18
Using the Infrared Thermometer/Transmitter 3 3-2 3.2 How To Power the Thermometer 3.2.1 OS550 Series Cable Connection The OS550 Series thermometer comes with a built-in 4.5 m (15 ' ) power/output cable. Power and output connections are made to the cable via stripped wire ends located at one end of the cable. The power/output cable can be short[...]
-
Pagina 19
3-3 Using the Infrared Thermometer/Transmitter 3 3.3 Operating The Thermometer 1. After installing the thermometer (see section 2.1) and connecting power (see section 3.2), your unit will be ready for use. Your unit has been shipped to you with the SLEEP/ON switch in the “ SLEEP ” position. Place the switch in the “ ON ” position to turn yo[...]
-
Pagina 20
Using the Infrared Thermometer/Transmitter 3 3-4 Figure 3-3. OS550 Series (-1 FOV) Figure 3-4. OS550 Series (-2 FOV) 7.0 .35" @ 24" 1.6 9mm @ 610 mm .8 21 42 181 .9 22 4.0 101 0 3 16 10 2 5 SPO T DIA.* (MM) *SPO T DIAMETER MEASURED A T 90% ENERGY 5.0 0 .61 1.5 1.0 3.0 SPO T DIA.* (IN) DIST ANCE: SENSOR TO OBJECT (FT) DIST ANCE: SENSOR TO [...]
-
Pagina 21
3-5 Using the Infrared Thermometer/Transmitter 3 Figure 3-5. OS550 Series (-3 FOV) Figure 3-6. OS550 Series (-4 FOV) 4.8" 1.0" @ 0" to 20" 2.5cm @ 51cm 1.2" 1.0" 2.5 6.0 4.0 8.0 10.0 12.2 160 120 80 40 1.0" 1.8" 2.4" 3.0" 3.6" 4.2" 1 ' 2 ' 200 8 ' 6 ' 0** DIST ANCE: SEN[...]
-
Pagina 22
Using the Infrared Thermometer/Transmitter 3 3-6 2.9 0.9" @ 0 1.9 22mm @ 0 1.2 1.0 31 26 48 75 0.9 0 3 16 10 *SPO T DIAMETER MEASURED A T 90% ENERGY D:S = 60:1 5 5.0 0 1.0 3.0 1.5 SPO T DIA.* (MM) SPO T DIA.* (IN) DIST ANCE: SENSOR TO OBJECT (FT) DIST ANCE: SENSOR TO OBJECT (M) .45" 11.5 3" SPOT DIA.* (MM) A *SPOT DIAMETER MEASURED T[...]
-
Pagina 23
3-7 3 Using the Infrared Thermometer/Transmitter 3 3.4 Measurement Techniques You can use the IR Thermometer to collect temperature data in any one of five different ways: • Spot Measurement — Measures the temperature of discrete objects such as motor bearings, engine exhaust manifolds, etc.: 1. Aim the sensor head at the desired target. 2. If [...]
-
Pagina 24
Using the Infrared Thermometer/Transmitter 3 3-8 • Moving Surface Scan - Measures the Temperature of Points on a Moving Surface: 1. Mount the sensor head and aim at your target. 2. If necessary, adjust the emissivity. The thermometer is now set up for measuring the temperature of a moving surface. 3. To record the temperature profile of the movin[...]
-
Pagina 25
3-9 Using the Infrared Thermometer 3 3.4.1 Real Time Mode (Active Operation) Definition: Real Time Mode is the active operational mode of the thermometer. In this mode, the thermometer constantly measures and displays temperature. On Sleep Mode P ower Applied, Sleep/On Switch in the On P osition Real Time Mode (Active) Recall Mode (P assive) Press [...]
-
Pagina 26
3-10 Using the Infrared Thermometer/Transmitter 3 Table 3-1. Functional Flow Chart when the Unit is On (Real Time Mode) Display Mode: Press to... Go to Go to Go to Go to Go to Go to or Go to Go to Go to or Go to Press to... LOCK or UNLOCK trigger ACTIV A TE / DEA CTIV A TE ACTIV A TE / DEA CTIV A TE ACTIV A TE / DEA CTIV A TE ACTIV A TE / DEA CTIV [...]
-
Pagina 27
3-11 3 Using the Infrared Thermometer/Transmitter * W hile in these 4 modes: Use key to change temperat u re from °F to °C or v ice v ersa. Use key to t u rn on the display b acklighting. * * * * Figure 3-9 Visual Function Flow Chart LCK ° F ° F LAL ° F ATC ° F PRN ° F ° F ° F ° F ° F HAL ° F MODE MODE DISPLA Y DISPLA Y ☞ ☞ ☞ ☞ [...]
-
Pagina 28
Using the Infrared Thermometer/Transmitter 3-12 3 3.5.1 Adjusting Emissivity Refer to Appendices B and C for information on emissivity before making your adjustment. 1. When the thermometer is powered up, the default emissivity setting will be set to 0.95. 2. If necessary, press the key to increment the target emissivity or press the key to decreme[...]
-
Pagina 29
3-13 Using the Infrared Thermometer/Transmitter 3 3.5.2 Calculating Temperature Values The thermometer calculates the MAX, MIN, dIF, and AVG temperatures based on the current temperature. To clear the “ AVG --- ” display, turn off the thermometer. When the thermometer goes from the sleep mode to the real-time mode, the MAX, MIN, dIF and AVG tem[...]
-
Pagina 30
Using the Infrared Thermometer/Transmitter 3-14 3 3.5.5 Using the Alarm Functions The thermometer provides audible and visible alarm indications. • To set the high alarm value : 1. Press the key until the High Alarm Display Mode (HAL) appears. 2. Press the key to increment the high alarm value. Press the key to decrement the high alarm value. 3. [...]
-
Pagina 31
3-15 Using the Infrared Thermometer/Transmitter 3 • To set the low alarm value (OS552, OS553, OS554) : 1. Press and hold the key until the Low Alarm Display Mode (LAL) appears. 2. Press the key to increment the low alarm value. Press the key to decrement the low alarm value. 3. Press the key to enable the low alarm function. The icon appears. If [...]
-
Pagina 32
Using the Infrared Thermometer/Transmitter 3-16 3 3.5.6 Using Ambient Target Temperature Compensation (OS552, OS553, OS554) Use the Ambient Target Temperature Compensation (AMB) Display Mode when high accuracy readings under both of these conditions are required: • The target has a low emissivity. • The ambient temperature around the target is [...]
-
Pagina 33
3-17 Using the Infrared Thermometer/Transmitter 3 8. Press and hold the key until the Emissivity Display Mode (E) appears. 9. Change the emissivity to the proper value for the target being measured (refer to Section 3.5.1). 10. Aim at the target. The target temperature and emissivity are displayed on the LCD. To disable the Ambient Target Temperatu[...]
-
Pagina 34
Using the Infrared Thermometer/Transmitter 3-18 3 Figure 3-10. Serial Printer Hookup 3. With power applied to the unit, press and hold the key until the Print Data Display Mode (PRN) appears. 4. Press the key to increment the printing interval. Press the key to decrement the printing interval. The printing interval (from 1 to 1999 seconds) is the t[...]
-
Pagina 35
3-19 Using the Infrared Thermometer/Transmitter 3 6. After all data is taken, press and hold the key until the Emissivity Display Mode (E) appears. 3.5.8 Sending Temperature Data to a Personal Computer (OS552, OS553, OS554) The thermometer can transmit temperature data to a Personal Computer via the RS-232 phone jack and the RS-232 cable. 1. Turn o[...]
-
Pagina 36
Using the Infrared Thermometer/Transmitter 3 3-20 How to Install IR_TEMPSOFT Please follow this installation procedure to install IR_TEMPSOFT: 1. Place the supplied CD disk into your CD-ROM drive. Make certain that you are not running any other applications at this time. Running other applications while trying to install IR_TEMPSOFT may cause insta[...]
-
Pagina 37
3-21 Using the Infrared Thermometer/Transmitter 3 program please contact technical support at Omega Engineering Inc. Connecting the IR-System to the PC Make certain that your Infrared Thermometer is powered down before you attempt to make any connections to the personal computer. Making connections between powered devices and a powered PC can cause[...]
-
Pagina 38
Using the Infrared Thermometer/Transmitter 3 3-22 waiting for the thermometer to transmit data through your RS-232 port. 4. Begin transmitting data from the thermometer by pressing and holding the key on the thermometer until the Print Data Display Mode (PRN) appears. 5. Press the “ UP ” key to increment the printing interval. Press the “ Dow[...]
-
Pagina 39
3-23 Using the Infrared Thermometer/Transmitter 3 3.5.9 Storing the Temperature Data on Command (OS553, OS554) The thermometer can store up to 100 temperature data points on command. Each set of temperature data is broken down into the temperature value, emissivity, and high alarm setpoint for that temperature. This data is stored in non-volatile m[...]
-
Pagina 40
Using the Infrared Thermometer/Transmitter 3 3-24 3.5.10 Erasing the Temperature Data from Memory The user can erase all 100 temperature data points in memory at any time by using the following procedure: 1. With power applied to the unit, place the SLEEP/ON switch to the ON position. 2. Press the key. The icon will appear. 3. Place the SLEEP/ON sw[...]
-
Pagina 41
3-25 Using the Infrared Thermometer/Transmitter 3 3.6 Recall Mode (Passive Operation) Definition: Recall Mode is the passive operational mode of the thermometer . In this mode, you may r eview the most recently stored temperatur e data and parameters. Figure 3-14. General Operational Block Diagram In order to get into the Recall Mode of operation, [...]
-
Pagina 42
Using the Infrared Thermometer/Transmitter 3 3-26 Table 3-2. Functional Flow Chart (Recall Mode) DISPLA Y MODE: Press to... Go to Go to Go to Go to Go to Go to or Go to Go to or Go to Go to Press to... Print stored data Displa y stored temperature Press or to... Set memor y location Display sho ws: Last temperature Emissivity Last temperature Maxim[...]
-
Pagina 43
3-27 Using the Infrared Thermometer/Transmitter 3 3.6.1 Reviewing the Last Parameters The thermometer stores the last temperature measured in the real time mode (refer to Table 3-1). This temperature can be recalled by pressing the key. 1. With power applied to the unit, place the SLEEP/ON switch to the SLEEP position. 2. Press the key to review th[...]
-
Pagina 44
Using the Infrared Thermometer/Transmitter 3 3-28 3 3. To download stored temperature data points from the thermometer, first make certain that it is not in printing mode. Make sure that the IR_TEMPSOFT is installed properly as explained in previous section. 4. On the main menu bar, click on “ Command-> Download Stored Data ” . The “ Store[...]
-
Pagina 45
3-29 Using the Infrared Thermometer/Transmitter 3 3.6.3 Reviewing Previously Stored Temperature Data (OS553, OS554) You can review all 100 stored temperature values on the thermometer display using the following procedure: 1. With power applied to the unit, place the SLEEP/ON switch to the SLEEP position 2. Press and hold the key until you see the [...]
-
Pagina 46
Using the Infrared Thermometer/Transmitter 3 3-30 Notes[...]
-
Pagina 47
4-1 4.1 W arnings and Cautions When using the laser sight accessory OS550-LS, you may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. • DO NOT LOOK AT THE LASER BEA[...]
-
Pagina 48
Laser Sight Accessory 4 4-2 4.2 Description A laser sighting accessory is available to aid in the sensor head installation process. When installing a line of sight Infrared transducer with a small spot size and long target distance, it is sometimes difficult to locate the center of the focused spot and the material to be measured. To solve this pro[...]
-
Pagina 49
4-3 Laser Sight Accessory 4 4.3 Operating the Laser Sight 4.3.1 Installing the Laser Sight onto the Thermometer The laser sight accessory (OS550-LS) screws onto the front of the sensor head. Do not over tighten the laser sight accessory onto the sensor head. This accessory is only used during sensor head installation and then removed. 4.3.2 Powerin[...]
-
Pagina 50
Laser Sight Accessory 4 4-4 Notes[...]
-
Pagina 51
5.1 Cleaning the Sensor Head Lens Although all lenses are quite durable, take care to prevent scratching when cleaning them. To clean the lens: 1. Blow off loose particles, using clean air. 2. Gently brush off remaining particles, using a camel hair brush. Alternatively, clean any remaining contaminants with a damp, soft, clean cloth. Be careful no[...]
-
Pagina 52
Maintenance 5 5-2 Notes[...]
-
Pagina 53
THERMOMETER Problem Solution The thermometer does a. Check for proper power not turn on (No Display) connections, see Section 3.2 b. Contact our Customer Service Department, unit requires service. a. Make sure you have entered the correct emissivity setting. b. Make sure you are not trying to measure a temperature above the maximum temperature rang[...]
-
Pagina 54
Troubleshooting Guide 6 6-2 Problem Solution The display is either a. Clean the thermometer lens. erratic or stays at Refer to Section 5.1. one reading b. Activate the Diagnostic Program in the thermometer as follows: c. Press the key. d. Hold down the key and press the key until “ VER X.X ” is displayed. You can expect to see and hear the foll[...]
-
Pagina 55
6-3 Troubleshooting Guide 6 The temperature reading is erratic. The sensor head has just been moved from one extreme temperature to room temperature [0°C or 50°C (32°F or 122°F)] or vice versa. The temperature reading is erratic. The sensor head has just been moved from room temperature (ambient temperature) to a temperature 10°C colder or war[...]
-
Pagina 56
Troubleshooting Guide 6 6-4 Notes[...]
-
Pagina 57
(Specifications are for all models except where noted) THERMOMETER Measuring OS551: –18°C to 400°C (0°F to 750°F) Temperature OS552: –18°C to 538°C (0°F to 1000°F) Range: OS553: –18°C to 871°C (0°F to 1600°F) OS554: –18°C to 1371°C (0°F to 2500°F) ±1% of reading or 3°F whichever is greater Distance to Spot Size Ratio: 10:1[...]
-
Pagina 58
Specifications 7 7-2 Emissivity: 0.10 to 1.00 in 0.01 increments, set via keypad Calculated Temperature Maximum (MAX), Minimum (MIN), Values: Average (AVG), Differential (dIF) Ambient Target OS552: set and enabled via keypad Temperature Compensation: OS553: set and enabled via keypad OS554: set and enabled via keypad RS-232 Output (for OS552: stand[...]
-
Pagina 59
7-3 Specifications 7 1 mV/degree C or F Analog Output: Accuracy: ± 2 m V referenced to the temperature display 0-5 Vdc Analog Output: Accuracy: ± 0.25% of full scale (Referenced to display reading) Scaling: Fixed (scaled to match full temperature range of model selected) Minimum Load: 600 ohms 4-20 mA Analog Output: Accuracy: ± 0.25% of full sca[...]
-
Pagina 60
7 7-4 Specifications 7 LASER SIGHT ACCESSORY (OS550-LS) Wavelength (Color): 630-670 nanometers (red) Operating Distance: Laser Dot 152 mm to 12 m (6 " to 40') Max. Output Optical Power: <1mW at 75°F ambient temperature, Class II, Laser Product European Classification: Class 2, EN60825-1 Maximum Operating Current: 25mA at 5.5 V FDA Cla[...]
-
Pagina 61
Key(s) Key(s) Functions • Selects one of the following Display Modes: E , MAX, MIN, dIF, AVG, HAL, LAL, AMB, PRN, or MEM. • Enables/disables High and Low Alarms. • Enables/disables Target Ambient Temperature Compensation. • Enables/disables sending data to the personal computer or serial printer. • Stores temperature data on command. • [...]
-
Pagina 62
1 8-2 Notes Glossary of Key Strokes 8[...]
-
Pagina 63
Thermal Radiation Heat is transferred from all objects via radiation in the form of electromagnetic waves or by conduction or convection. All objects having a temperature greater than absolute zero (-273°C, -459°F, 0 K) radiate energy. The thermal energy radiated by an object increases as the object gets hotter. Measurement of this thermal energy[...]
-
Pagina 64
Appendix: How Infrared Thermometry Works A A-2 Blackbody When thermal radiation falls on an object, part of the energy is transmitted through the object, part is reflected and part is absorbed. A blackbody is defined as an ideal object that absorbs all the radiation incident upon it. The best example of a real object that acts like a blackbody is a[...]
-
Pagina 65
A-3 Appendix: How Infrared Thermometry Works A Wien’s Displacement Law describes the exact mathematical relationship between the temperature of a blackbody and the wavelength of the maximum intensity radiation. where λ m = wavelength measured in microns T = temperature in Kelvin Calculating T emperature The net thermal power radiated by an objec[...]
-
Pagina 66
Appendix: How Infrared Thermometry Works A A-4 Optics Field of View Accurate measurement of temperature via infrared means depends strongly on the size of the object and the distance between the thermometer and the object. All optical devices (e.g. cameras, microscopes, infrared thermometers) have an angle of vision, known as a field of view or FOV[...]
-
Pagina 67
B-1 Table B-1 provides guidelines for estimating the emissivity of various common materials. Actual emissivity, especially of metals, can vary greatly depending upon surface finish, oxidation, or the presence of contaminants. Also, emissivity or infrared radiation for some materials varies with wavelength and temperature. To determine the exact emi[...]
-
Pagina 68
Appendix: Emissivity Values B B-2 NONMET ALS Material Emissivity ( ε ) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.96 Asphalt, tar, pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.95 – 1.00 Brick – red and rough . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Pagina 69
In Appendix A, we showed how emissivity is an important parameter in calculating the temperature of an object via infrared means. In this section we discuss how to determine a specific emissivity value. If you know the material of the object, use Table B-1 in Appendix B to look up its approximate emissivity. Most organic materials such as plastics,[...]
-
Pagina 70
Appendix: Determining an Unknown Emissivity C C-2 Method 3 1. Use this method to measure objects at temperatures below 500°F (260°C). 2. Place a large piece of masking tape on the object (or at least a sample of the object material). Allow time for the masking tape to reach the object temperature. 3. Set the emissivity of the thermometer to 0.95.[...]
-
Pagina 71
C-3 Appendix: Determining an Unknown Emissivity C Method 4 1. Paint a sample of the object material with flat black lacquer paint. 2. Set the emissivity to 0.97 and measure and record the temperature of the painted portion of the sample material - Area “ A ” in Figure C-1. Make sure that the painted area of object material fills the FOV of the [...]
-
Pagina 72
D-1 ADDENDUM TO OS550/OS550-BB MANUAL IMPORTANT CONSIDERATIONS BEFORE INSTALLATION Follow all safety precautions and operating instructions outlined in this addendum and your OS550 Series manual. - - - - - - - - - - - - - - - - - - - - - - - - - SYMBOL KEY - - - - - - - - - - - - - - - - - - - - - - - - CAUTION: Refer to accompanying documents. Ref[...]
-
Pagina 73
D-2 ADDENDUM TO OS550/OS550-BB MANUAL OS550 SENSOR HEAD GND VOL TAGE O/P: 0-5 Vdc CURRENT O/P: 4-20 mA 1 +PWR (RED) 2 -PWR (BLACK) 3 +O/P (WHITE) 4 -O/P (GREEN) 5 SHIELD (BARE) [DRAIN WIRE] DC POWER SUPPL Y INTEGRAL IMPEDENCE PROTECTED EARTH GROUND ( ) ( ) DIGIT AL VOL TMETER/ AMMETER - - - - - - - - - - - - - - - TYPICAL INSTALLATION SCHEMATIC - -[...]
-
Pagina 74
I-1 Index I A Air Purge Collar ....................... 2-6 Alarms ........................... 3-14, 3-15 Ambient Target Temperature Compensation ...................... 3-16 B Backlighting Icon ...................... 1-3 Blackbody ........................ A-2, C-3 C Computer: Parameters: Speed, Data, Parity, Stop Bit ............................ 3-1[...]
-
Pagina 75
LOCK (Lock) ........................ 1-3 ▲ & ❍ - ● ................................ 1-3 Key Strokes ............................... 8-1 L Label Layout: Danger & Certification ............ .....................Inside Back Cover Laser Sight Installing onto Thermometer ...................... 4-3 Line of Sight ......................... 4-[...]
-
Pagina 76
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase on the base unit and 13 months from date of purchase on Laser Sight Module . OMEGA WARRANTY adds an additional one (1) month grace period to the normal product warranty to cover handling[...]
-
Pagina 77
M2830/1104 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Contro[...]