Omega Vehicle Security DP63000A-I manuale d’uso
- Visualizza on-line o scarica il manuale
- 16 pagine
- 1.02 mb
Vai alla pagina of
Manuali d’uso simili
-
Welding System
Omega Vehicle Security LDP1XX-21
14 pagine 0.09 mb -
Thermometer
Omega Vehicle Security OS520
2 pagine 0.31 mb -
Switch
Omega Vehicle Security LVCN700 Series
10 pagine 0.35 mb -
Thermometer
Omega Vehicle Security OS425-LS
4 pagine 0.9 mb -
Welding System
Omega Vehicle Security OMP-MODL
297 pagine 2.24 mb -
Switch
Omega Vehicle Security OME-PIO-D56
53 pagine 2.55 mb -
Power Supply
Omega Vehicle Security LDN-PS
28 pagine 1.2 mb -
Thermometer
Omega Vehicle Security HH-21
31 pagine 1.09 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Omega Vehicle Security DP63000A-I. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Omega Vehicle Security DP63000A-I o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Omega Vehicle Security DP63000A-I descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Omega Vehicle Security DP63000A-I dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Omega Vehicle Security DP63000A-I
- nome del fabbricante e anno di fabbricazione Omega Vehicle Security DP63000A-I
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Omega Vehicle Security DP63000A-I
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Omega Vehicle Security DP63000A-I non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Omega Vehicle Security DP63000A-I e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Omega Vehicle Security in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Omega Vehicle Security DP63000A-I, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Omega Vehicle Security DP63000A-I, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Omega Vehicle Security DP63000A-I. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
LP0694A omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digita l P P anel M M eter[...]
-
Pagina 2
OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@o[...]
-
Pagina 3
3 z FOUR SELECT ABLE D.C. RANGES 200 µ A, 2 mA, 20 mA, 200 mA z MINIMUM AND MAXIMUM DISPLA Y CAPTURE z LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING z 0.48" (12.2 mm) HIGH DIGITS z OPTIONAL SETPOINT OUTPUT MODULES z OPTIONAL SERIAL COMMUNICA TIONS MODULES (RS232 or RS485) z OPERA TES FROM 9 TO 28 VDC POWER SOURCE z FRONT P ANEL OR SOFTWARE PR[...]
-
Pagina 4
1. DISPLA Y : 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I : Reflective LCD with full viewing angle DP63000B-I : T ransmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER : Input voltage range is +9 to +28 VDC with short c[...]
-
Pagina 5
5 ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below . The plug-in cards, that are sold separately , can be installed initially or at a later date. W ARNING: Disconnect all power to the unit before in[...]
-
Pagina 6
WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter . All conductors should conform to the meter ’ s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that the power supplied to the meter (DC o[...]
-
Pagina 7
7 4.3 INPUT WIRING CAUTION : Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not, hazardous voltage may be present at the[...]
-
Pagina 8
8 5.0 R EVIEWING THE F RONT B UTTONS AND D ISPLAY PROGRAMMING MODE ENTR Y (SEL BUTT ON) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing and holding the SEL button. If it is no[...]
-
Pagina 9
9 6.1 MODULE 1 - S IGNAL I NPUT P ARAMETERS ( 1-INP ) P ARAMETER MENU ª « 0.02A rAN6E INPUT RANGE Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution. This selection and the position of the Input Range Jumper must match.[...]
-
Pagina 10
Entering Code 66 will overwrite all user settings with the factory settings. The meter will display rESEt and then return to CodE 00 . Press the SEL button to exit the module. 10 6.2 MODULE 2 - S ECONDARY F UNCTION P ARAMETERS ( 2-SEC ) P ARAMETER MENU MIN DISPLA Y ENABLE USER INPUT ASSIGNMENT Select the value(s) to which the User Input Function is[...]
-
Pagina 11
11 The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out ( P-Loc ) in the User Input Function parameter (Module 1). T wo programming modes are available. Full Programming mode allows all parameters to be viewed and modified. Quick Programming mod[...]
-
Pagina 12
Enter the reset action of the output. See figure for details. Auto = Automatic action; This action allows the output to automatically reset off at the trigger points per the Setpoint Action shown in Setpoint Output Figures. The “on” output may be manually reset (of f) immediately by the front panel RST button or user input.The output remains of[...]
-
Pagina 13
13 6.5 MODULE 5 - S ERIAL S ETUP P ARAMETERS ( 5 -S S E r ) The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter . Refer to the DP6-COM bulletin for complete details on DP63000 serial communications. P ARAMETER MENU button or user input manual reset, serial reset command[...]
-
Pagina 14
PROGRAMMING QUICK OVERVIEW Press and hold SEL button to enter Programming Mode.[...]
-
Pagina 15
W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers[...]
-
Pagina 16
Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels & Assemblies ] W ire: Thermocouple, RTD & Thermistor ] Calibrators & Ice P oint References ] Recorders, Controllers & Process Monitors ] In[...]