Omega Vehicle Security OS643W manuale d’uso
- Visualizza on-line o scarica il manuale
- 19 pagine
- 0.19 mb
Vai alla pagina of
Manuali d’uso simili
-
Thermometer
Omega Vehicle Security DP97
24 pagine 1.11 mb -
Thermometer
Omega Vehicle Security HH806W
3 pagine 3.61 mb -
Thermometer
Omega Vehicle Security HH65
2 pagine 0.14 mb -
Thermometer
Omega Vehicle Security OS530 Series
2 pagine 0.31 mb -
Thermometer
Omega Vehicle Security HH501BK
12 pagine 0.17 mb -
Thermometer
Omega Vehicle Security K-79
4 pagine 0.08 mb -
Thermometer
Omega Vehicle Security OS542
10 pagine 0.27 mb -
Thermometer
Omega Vehicle Security OS425-LS
4 pagine 0.9 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Omega Vehicle Security OS643W. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Omega Vehicle Security OS643W o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Omega Vehicle Security OS643W descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Omega Vehicle Security OS643W dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Omega Vehicle Security OS643W
- nome del fabbricante e anno di fabbricazione Omega Vehicle Security OS643W
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Omega Vehicle Security OS643W
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Omega Vehicle Security OS643W non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Omega Vehicle Security OS643W e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Omega Vehicle Security in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Omega Vehicle Security OS643W, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Omega Vehicle Security OS643W, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Omega Vehicle Security OS643W. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
OMEGA OS643W Infrared Thermometer[...]
-
Pagina 2
OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Tel: (95) 800-TC-OMEGA SM Customer Service: 1-800-622-2378 / 1-800-622-BEST SM FAX: (95) 203-359-7807 Engineering Service: 1-80[...]
-
Pagina 3
1 INTRODUCTION This instrument is a portable easy use 3½ digit, compact-sized digital thermometer designed to use infrared or K-type thermocouple as input. Meter with Backlit LCD, Auto-hold function and auto power off (15 seconds approx.) feature after releasing MEAS button to extend battery life and with analog signal output function. Temperature[...]
-
Pagina 4
2 WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. The symbol on the instrument indicates that the operator must refer to an explanation in this manual.[...]
-
Pagina 5
3 CAUTION • Do not use the unit near any device which generates strong electromag- netic radiation or near a static electrical charge, as these may cause errors. • Do not point the lens at the sun or at any other source of strong light. If you do, the sensor may be damaged. • Do not contact the lens against the object whose temperature is to [...]
-
Pagina 6
4 SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overrange : (OL) or (-OL) is displayed. Low battery indication: the " " is displayed when the battery voltage drops below the operating level. Measurement rate: 2.5 times per second, nominal. Operating Environment: 32°F to 122°F (0°C [...]
-
Pagina 7
5 Infrared Radiation ELECTRICAL Temperature Range: 0°F to 500°F, -20°C to 260°C. Display Resolution: 1°F / 1°C. Accuracy: ±3% of reading or ±6°F/3°C, whichever is greater @ 64.4 to 82.4°F (@ 18 to 28°C) ambient operating temperature. Temperature Coefficient: ±0.2% of reading or ±0.36°F/0.2°C, whichever is greater, change in accuracy[...]
-
Pagina 8
6 Spot size increases with distance from the probe tip as shown[...]
-
Pagina 9
7 K-type thermocouple ELECTRICAL Temperature Range: -58°F to 1999°F, -50°C to 1300°C. Display Resolution: 1°F / 1°C. Accuracy: Accuracy is specified for operating temperatures over the range of 64°F to 83°F (18°C to 28°C), for 1 year, not including thermocouple error. ±(0.3% rdg + 2°F) -58°F to 1999°F ±(0.3% rdg + 1°C) -50°C to 100[...]
-
Pagina 10
8 OPERATING INSTRUCTIONS MEAS (MEASURE) Button Depress MEAS button to turn on the meter for measuring temperature. Releasing MEAS button to stop measuring temperature and automatically hold the display reading, the meter turns off automatically after 15 seconds.[...]
-
Pagina 11
OPERATION Infrared Radiation Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select IR Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light. 4. Use "°F/°C" switch to select °F or °C the Temperature Range. 5. Point the len[...]
-
Pagina 12
10 K-type thermocouple Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select K Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light. 4. Use "°F/°C" switch to select °F or °C the Temperature Range. 5. Connect a type K the[...]
-
Pagina 13
11 MEASUREMENT CONSIDERATIONS 1. Theory of Measurement Every object emits infrared energy in accordance with its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object. 2. About Infrared Infrared radiation is a form of energy (electromagnetic radiation), and has the property t[...]
-
Pagina 14
12 4. Emissivity All objects emit invisible infrared energy. The amount of energy emitted is proportional to the object's temperature and its ability to emit IR energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish. Emissivity values range from 0.10 for a very reflective object to[...]
-
Pagina 15
13 MAINTENANCE Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The " " appears on the LCD display when replacement is needed. To replace the batteries, remove the screw from the back of the meter and lift off the battery cover case. Remove the batteries from battery contacts. Cleaning Periodically wipe the case wi[...]
-
Pagina 16
Substance Thermal Substance Thermal emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 W ater 0.92 to 0.96 Lacquer (matt) 0.97 Ic e 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.[...]
-
Pagina 17
WARRANTY OMEGA warrants this unit to be free of def ects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month g race period to the normal one (1) year product warranty to cov er handling and shipping time . This ensures that OMEGA's custo[...]
-
Pagina 18
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct b ut OM[...]
-
Pagina 19
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters þ Laboratory Heaters PRESSURE/STRAIN AND FORCE þ Transducers & Strain Gauges þ Load Cells & Pressure Gauges þ Displacement Transducers þ [...]