Vai alla pagina of
Manuali d’uso simili
-
Blood Pressure Monitor
Omron Healthcare 7300W
42 pagine 1.51 mb -
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-MLA
1 pagine 0.62 mb -
Blood Pressure Monitor
Omron Healthcare M5-I
8 pagine 0.2 mb -
Blood Pressure Monitor
Omron Healthcare HEM-630
20 pagine 0.58 mb -
Blood Pressure Monitor
Omron Healthcare HEM-757
20 pagine 0.19 mb -
Blood Pressure Monitor
Omron Healthcare HEM-422CRLC
40 pagine 0.81 mb -
Blood Pressure Monitor
Omron Healthcare RX3
19 pagine 0.5 mb -
Blood Pressure Monitor
Omron Healthcare HEM-711AC
56 pagine 1.17 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Omron Healthcare HEM-712C. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Omron Healthcare HEM-712C o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Omron Healthcare HEM-712C descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Omron Healthcare HEM-712C dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Omron Healthcare HEM-712C
- nome del fabbricante e anno di fabbricazione Omron Healthcare HEM-712C
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Omron Healthcare HEM-712C
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Omron Healthcare HEM-712C non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Omron Healthcare HEM-712C e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Omron Healthcare in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Omron Healthcare HEM-712C, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Omron Healthcare HEM-712C, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Omron Healthcare HEM-712C. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
INSTRUCTION MANUAL AUTOMA TIC INFLA TION BLOOD PRESSURE MONITOR Model HEM-712C R ENGLISH ESP AÑOL[...]
-
Pagina 2
2 T ABLE OF CONTENTS Introduction …………………………………………………………… 3 Important Safety Notes ……………………………………………… 4 Know Y our Unit ……………………………………………………… 5 Suggestions Before T aking A Measurement ………………………… 6 Batter y[...]
-
Pagina 3
3 INTRODUCTION Thank you for purchasing the Omron HEM-712C Automatic Inflation Blood Pressure Monitor . Fill-in for future reference DA TE PURCHASED: ______________ SERIAL NUMBER: ________________ Staple your purchase receipt here. This completely automatic instrument quickly measures your blood pressure and pulse rate. The measurement reading is c[...]
-
Pagina 4
4 IMPORT ANT SAFETY NOTES To assur e the correct use of the pr oduct basic safety measures should always be followed including the pr ecautions listed below: Read all information in the instruction book and any other literature included in the box before using the unit. Contact your physician for specific information about your blood pressu[...]
-
Pagina 5
5 KNOW YOUR UNIT HEM-712C Air Jack Air Plug AC Adapter Jack Systolic Blood Pressure Display Diastolic Blood Pressure /Pulse Display Arm Cuff Cuff T ube ST AR T Button ON/OFF Button MEMOR Y Button Heart Symbol Cuff T ab[...]
-
Pagina 6
6 SUGGESTIONS BEFORE T AKING A MEASUREMENT 1. Av oid eating, smoking, and exercising for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A void taking measurements during stressful times. 3. Remov e tight-fitting clothing from your left arm. 4. Measurements should [...]
-
Pagina 7
7 BA TTER Y INST ALLA TION / REPLACEMENT 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positi ve) and – (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . NO TE: If the Low Battery Indicator appears on the display , repl[...]
-
Pagina 8
8 CARE AND MAINTENANCE To k eep your digital blood pressur e monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: Clean the monitor with a soft dry cloth. Do not use any abrasi ve or v olatile cleaners. Do not attempt to clean the cuf f. Nev er immerse the monitor or any components in water . Store t[...]
-
Pagina 9
9 HOW TO APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the se wn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. P ass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Put your left[...]
-
Pagina 10
10 HOW TO APPL Y THE ARM CUFF 4. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 5. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 6. Make certain the cuf f fits snugly around your arm. The cuff should mak e good contact with your skin. 7. Sit in [...]
-
Pagina 11
11 HOW TO T AKE A MEASUREMENT 1. Press the ON/OFF button. a) All display symbols appear for approximately one second. This is the initial LCD test. b) The display symbols disappear and the Deflation Indication symbol ( ) starts to flash. c) When the monitor completes the necessary prepa rations before measurement, the Heart Symbol () appears in the[...]
-
Pagina 12
12 3. When the correct pressure value is reached, the cuff starts to deflate automatically . As the cuff deflates, decreasing numbers appear on the display . The Heart Symbol () flashes at ev ery heartbeat. 4. When the measurement is complete, the Heart Symbol ( ) stops flashing and your blood pressure and pulse rate are displayed alternately . Res[...]
-
Pagina 13
13 HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen (14) sets of readings. Every time you complete the measurement, the monitor automatically stores the blood pressure reading and pulse rate. • Push the MEMOR Y button to recall stored readings while the Heart Symbol ( ) is displayed. • T o delete all stored [...]
-
Pagina 14
14 ERROR INDICA TORS Error Symbol Correction Cause Cuff under -inflated. Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse. Cuff o ver-inflated (more than 300 mmHg). Batteries hav e run down. Carefully read and repeat steps listed under “How To Ta ke A Reading. ” Replace all four “ AA” batteries. R[...]
-
Pagina 15
15 FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc[...]
-
Pagina 16
16 W ARRANTY INFORMA TION Y our HEM-712C Automatic Blood Pressure Monitor , excluding the monitor cuff, is warranted to be free from defects in materials and workmanship appearing within 2 years, when used in accordance with the instructions provided with the monitor . The monitor cuff is warranted to be free from defects in materials and workmansh[...]
-
Pagina 17
17 W ARRANTY INFORMA TION Limited W arranties (Outside of the USA and Canada) Y our HEM-712C Automatic Blood Pressure Monitor, excluding the monitor cuf f, is w arranted to be free from defects in materials and workmanship appearing within 2 years, when used in accordance with the instructions provided with the monitor . The monitor cuff is warrant[...]
-
Pagina 18
18 SPECIFICA TIONS Model: HEM-712C Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40-180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valv e Rapid Air Release: Automatic exhaust v alve Pressure Detectio[...]
-
Pagina 19
19 NOTES[...]
-
Pagina 20
Made in China Manufactured by: OMR ON HEAL THCARE, INC. 300 Lake view Parkway V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2003 Omron Healthcare, Inc. HEM-712CINST Rev B[...]
-
Pagina 21
MANUAL DE INSTRUCCIONES MONITOR DE PRESIÓN ARTERIAL DE INFLADO AUTOMÁTICO Modelo HEM-712C R ESP AÑOL[...]
-
Pagina 22
2 T ABLA DE CONTENIDO Introducción ………………………………………………………… 3 Obser vaciones importantes sobre seguridad …………………… 4 Conozca la unidad ………………………………………………… 5 Sugerencias preliminares para medir la presión arterial ………… 6 Instalación y recambio d[...]
-
Pagina 23
3 INTRODUCCIÓN Gracias por adquirir el Monitor de presión arterial de inflado automático Omron, modelo HEM-712C. Complete estos datos en caso de que necesite consultarlos en el futuro FECHA DE COMPRA: ____________ NÚMERO DE SERIE: ______________ Engrape aquí su recibo de compra. Este instrumento completamente automático mide rápidamente su p[...]
-
Pagina 24
4 OBSERV ACIONES IMPORT ANTES SOBRE LA SEGURIDAD P ara asegurar el uso correcto del producto, siempre se deben tomar medidas de seguridad básicas, entre ellas las que se detallan a continuación: Antes de utilizar la unidad, lea toda la información del manual de instrucciones y toda otra información que se incluya en la caja. Solicite a [...]
-
Pagina 25
5 CONOZCA LA UNIDAD HEM-712C Entrada del tubo de aire Conector del tubo de aire Entrada para el transformador de CA V isualización de la presión arterial sistólica V isualización de la presión arterial diastólica y del pulso Brazalete T ubo del brazalete Botón de inicio Botón de encendido Botón de memoria Símbolo del corazón Borde del br[...]
-
Pagina 26
6 SUGERENCIAS PRELIMINARES P ARA MEDIR LA PRESIÓN ARTERIAL 1. Evite comer , fumar y hacer ejercicios físicos 30 minutos antes de medir la presión arterial. Decanse al menos 15 minutos antes de realizar la medición. 2. El estrés aumenta la presión arterial. Evite medir su presión arterial cuando esté bajo estrés. 3. Retire todo tipo de ropa[...]
-
Pagina 27
7 INST ALACIÓN Y RECAMBIO DE LAS PILAS 1. Retire la tapa del compartimiento para pilas en la dirección que indica la flecha. 2. Coloque 4 pilas “ AA” de modo que las polaridades positiv a (+) y n egat iva (–) coincidan con las del compartimiento. 3. V uelva a colocar la tapa. NO T A: Si el indicador de pilas descar gadas aparece en el visor[...]
-
Pagina 28
8 CUIDADO Y MANTENIMIENTO Para conservar su monitor digital de presión arterial en prefecto estado y protegerlo contra daños, siga las instrucciones que se detallan a continuación: Limpie el monitor con un paño suav e y seco. No utilice limpiadores abrasiv os ni volátiles. No intente limpiar el brazalete. Nunca sumerja el monitor ni ninguno de[...]
-
Pagina 29
9 CÓMO COLOCAR EL BRAZALETE 1. Si el brazalete está armado correctamente, el cierre tipo V elcro quedará en la parte e xterna del brazalete y el anillo metálico en "D" no estará en contacto con la piel. 2. P ase el extremo del brazalete que esté más alejado del tubo a trav és del anillo metálico en “D” para formar un lazo. La[...]
-
Pagina 30
10 CÓMO COLOCAR EL BRAZALETE 4. T ire del brazalete de manera tal que los extremos superior e inferior queden ajustados en forma pareja alrededor del brazo. 5. Cuando el brazalete se encuentre en la posición correcta, presione el lado áspero del V elcro FIRMEMENTE contra su lado suav e. 6. Asegúrese de que el brazalete esté correctamente ajust[...]
-
Pagina 31
11 CÓMO MEDIR LA PRESIÓN ARTERIAL 1. Pulse el botón ON/OFF (Encendido/Apagado). a) T odos los símbolos aparecen en el visor durante aproximadamente un segundo. Ésta es la prueba inicial del visor . b) Los símbolos del visor desaparecen y el símbolo indicador de desinflado ( ) comienza a titilar . c) Cuando el monitor termina de prepararse pa[...]
-
Pagina 32
12 3. Cuando el brazalete logra el valor adecuado, comienza a desinflarse automáticamente. A medida que se desinfla, aparecen números decrecientes en el visor . El símbolo del corazón ( ) titila con cada latido. 4. Cuando la medición ha f inalizado, el símbolo del corazón ( ) deja de titilar y el visor muestra su pulso y presión arterial al[...]
-
Pagina 33
13 CÓMO UTILIZAR LA FUNCIÓN DE MEMORIA El monitor tiene una memoria que puede almacenar catorce (14) series de mediciones. Cada vez que se completa una medición, el monitor guarda automáticamente los valores de pulso y las mediciones de presión arterial. • Pulse el botón MEMOR Y (Memoria) para recuperar mediciones guardadas mientras aparece[...]
-
Pagina 34
14 INDICADORES DE ERROR Símbolo de error Corrección Causa Brazalete inflado insuficientemente. Movimiento durante la medición No se pueden realizar mediciones de presión arterial ni de pulso debido a que el pulso arterial es muy débil. Pulsera inflada e xcesi vamente (supera los 300 mmHg) Pilas agotadas. Lea detenidamente y repita los pasos me[...]
-
Pagina 35
15 DECLARACIÓN DE LA FCC Nota: POSIBILID AD DE INTERFERENCIA EN RADIO / TELEVISIÓN (para los EE.UU. únicamente). Las pruebas a las que se sometió este producto comprobaron que cumple con las limitaciones establecidas para dispositiv os digitales Clase B, de conformidad con la sección 15 de las Normas FCC. El propósito de estas limitaciones es[...]
-
Pagina 36
16 INFORMACIÓN ACERCA DE LA GARANTÍA Su Monitor automático de presión arterial, modelo HEM-712C, sin incluir el brazalete, está garantizado contra defectos de material y mano de obra que surjan en un periodo de 2 años, cuando se lo emplee según las instrucciones suministradas junto con el monitor . El brazalete está garantizado contra defec[...]
-
Pagina 37
17 INFORMACIÓN ACERCA DE LA GARANTÍA Garantías limitadas (fuera de los EEUU y Canadá) Su Monitor automático de presión arterial, modelo HEM-712C, sin incluir el brazalete, está garantizado contra defectos de material y mano de obra que surjan en un periodo de 2 años, cuando se lo emplee según las instrucciones suministradas junto con el mo[...]
-
Pagina 38
18 ESPECIFICACIONES TÉCNICAS Modelo: HEM-712C V isor: V isor digital LCD Espectro de medición: Presión: 0 a 280 mmHg Pulso: 40 a180/min. Precisión/Calibrado: Presión: ±3 mmHg o 2% de la medición Pulso: ±5% de la medición Inflado: Automático mediante bomba eléctrica Desinflado: V álvula de liberación automática de presión Liberación [...]
-
Pagina 39
19 NOT AS[...]
-
Pagina 40
Hecho en China F abricado por: OMRON HEALTHCARE, INC. 300 Lake view Parkway V ernon Hills, Illinois 60061 www .omronhealthcare.com © 2003 Omron Healthcare, Inc. HEM-712CINST Rev B[...]