Outback Power Systems FLEXnet DC manuale d’uso
- Visualizza on-line o scarica il manuale
- 34 pagine
- 0.46 mb
Vai alla pagina of
Manuali d’uso simili
-
Power Supply
Outback Power Systems FW-X240
16 pagine 0.47 mb -
Power Supply
Outback Power Systems DC
34 pagine 0.44 mb -
Power Supply
Outback Power Systems FX
2 pagine 1.85 mb -
Power Supply
Outback Power Systems VFX2812M
2 pagine 1.19 mb -
Power Supply
Outback Power Systems FX SERIES
59 pagine 0.63 mb -
Power Supply
Outback Power Systems FW-IOB-D-120VAC
8 pagine 0.37 mb -
Power Supply
Outback Power Systems FX2012MT
2 pagine 1.19 mb -
Power Supply
Outback Power Systems FLEXnet DC
34 pagine 0.46 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Outback Power Systems FLEXnet DC. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Outback Power Systems FLEXnet DC o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Outback Power Systems FLEXnet DC descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Outback Power Systems FLEXnet DC dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Outback Power Systems FLEXnet DC
- nome del fabbricante e anno di fabbricazione Outback Power Systems FLEXnet DC
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Outback Power Systems FLEXnet DC
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Outback Power Systems FLEXnet DC non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Outback Power Systems FLEXnet DC e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Outback Power Systems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Outback Power Systems FLEXnet DC, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Outback Power Systems FLEXnet DC, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Outback Power Systems FLEXnet DC. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
U ser ’ s Guide Includes M ounting and Installation net DC TM[...]
-
Pagina 2
1 Dear OutBack Customer , Thank you for y our purchase of OutBack pr oducts. W e make ever y e or t to assure our power conversion pr oducts will give you long and reliable service for your r enewable energy system. As with any manufactured device , repairs might be needed due to damage , inappropriate use, or unintentional defect. Please not e [...]
-
Pagina 3
2 Disclaimer UNLESS SPECIFICALL Y A GREED T O IN WRITING, OUTBACK POWER SYSTEMS: (a) MAKES NO W ARRANT Y AS TO THE ACCURACY , SUFFICIENCY OR SUIT ABILIT Y OF ANY TECHNICAL OR O THER INFORMA TION PR OVIDED IN ITS MANU ALS OR OTHER DOCUMENT A TION. (b) ASSUMES NO RESPONSIBILIT Y OR LIABILIT Y FOR LOSS OR D AM AGE, WHETHER DIREC T , INDIREC T , CONSEQ[...]
-
Pagina 4
3 T ABLE OF C ONTENTS W arranty Summar y..................................................................................................................................................................... 1 Introduction .................................................................................................................. ..............[...]
-
Pagina 5
4 Introduction The OutBack P ow er Systems FLEXnet DC The FLEXNet DC collects, monitors and recor ds time -based battery amp, watt and volt data for displa y on the OutBack MA TE series of products, allowing for more accurate set point adjustments and pr ecise batter y rechar ging. F ive LEDs on the FLEXnet DC act as a state - of-charge indicator b[...]
-
Pagina 6
5 Think of the input shunts as breaks or junctions in the DC (-) conductor . The current is conducted as though it were a continuous conductor , but the shunts allow the user to monitor the current, providing inf ormation for more accurate batt er y recharg ing. BA T + BA T - CHARGE CONTROLLER FX INVERTER/CHARGER SHUNT C SHUNT B SHUNT A CHARGE CONT[...]
-
Pagina 7
6 LEDs* 10-postion wiring block 1: BA T - 2: BA T+ 3. Relay 4. Relay 5: C DEVICE SIDE 6: C BA T (-) SIDE 7: B DEVICE SIDE 8: B BA T (-) SIDE 9: A DEVICE SIDE 10: A BA T (-) SIDE • BA T+/- must connect directly to battery terminals of the bank being monitored . • Pr oper polarity must be obser ved on all connections. 1 2 3 4 5 6 7 8 9 10 • Bli[...]
-
Pagina 8
7 The FLEXNet DC package includes: A. FLEXnet DC B. T en-pin wiring plug for shunt, rela y and batter y connections C. Six feet of CA T5 cable for HUB connection D . T en-foot color-coded twisted pair ( TP) cable connects to the batter y E. Thr ee six-f oot, color-coded, twisted pair cables for shunt connections F . T wo #6-32 X 3/8” panhead mach[...]
-
Pagina 9
8 • Inser t the FLEXNet DC inside the DC breaker box and through the back side of the breaker bracket; secure with two #6-32 X 3/8 panhead machine screws (included) torqued at 5 t o 8 inch-pounds • Connect all wires to the ten-pin wiring connector . Do not leave an y loose wires! • C onnect each twisted pair to a shunt. Example: • Battery s[...]
-
Pagina 10
9 • Black/Whit e twisted pair connects directly to the batter y bank being monitored: Whit e to BA T (-) Black to BA T (+) An appropriate fuse—with a rating of 5 amps or less and greater than 100 volts DC—may be placed in the black conduc tor W iring Block Connections Color-coded twisted pair 18 A WG connects the wiring block and shunt(s) or [...]
-
Pagina 11
10 (Installing the FLEXnet DC continued) • Insert the 10-pin connec tor to the wiring block on the back of the FLEXnet DC. • Install the CA T5 cable into the RJ45 jack in the back of the FLEXNet DC. Connect the other end of the cable to the HUB using P ort #2 or higher . • Replace the breaker bracket and secure with its four corner fasteners [...]
-
Pagina 12
11 FLEXNet DC Measurements The FLEXNet DC can measure and recor d: • V olts for one batt er y bank* • Amps** • KiloWatts • kWhrs removed fr om the batteries • kWhrs returned to the batteries • Amp hours removed fr om the batteries • Amp hours returned to the batteries • Batter y bank state- of- charge • Lifetime kiloamp hours remo[...]
-
Pagina 13
12 Logged Data* The previous 128 days of data ar e accessible with the MA TE. The data is logged each night at midnight. Be sure the M A TE’ s clock is set to the correct local time (ref er to your M A TE manual). * Data Logg ing User A djustable Set P oints • Batter y charge factor (65-100%) [see page 29] • Batter y bank capacity 0-10000 amp[...]
-
Pagina 14
13 P rog ramming and Using the MA TE for FLEXNet DC Operations At initial power up , use the MA TE (see pages 17-28) to program: • Batter y Bank 20 Hour Capacity (provided by the manufacturer) in amp hours (from 100- 10,000 amp-hours in ten amp increments) • Batter y charge parameters Return amps: See the manufacturer recommendations or set to [...]
-
Pagina 15
14 FLEXNet DC Modes - Channel A is enabled by default - Each input channel is either enabled or disabled. - A disabled channel will show zero values only . - All enabled channels will run in parallel. - An enabled channel monitors and totals all current owing into or out of the batter y bank through its shunt. Any DC loads or sour ces wired dir[...]
-
Pagina 16
15 The FLEXnet DC ’ s LEDs indicate the SOC by their individual ON/OFF states. Excluding the RED or last LED , when viewing the remaining f our LEDs—GREEN, YELL O W , YELL O W , AND YELL O W— the f ollowing are true: • All LEDs on = 90-100% SOC GREEN LED blinking— charge parameters met Solid GREEN LED—SOC is above 90% • All but top LE[...]
-
Pagina 17
16 Relay L ogic: • Expressed as NO/NC (Normally Open/Normally Closed), basically o /on • May be controlled via the inv er t logic selection from the M A TE. • T oggling the relay log ic setting changes the logic mode for Hi or L o set points Example: The relay ’ s contac ts are closed when the Hi set point is satis ed and open again w[...]
-
Pagina 18
17 F rom the MAIN M A TE menu, pr ess the <SUM> soft ke y to view a summar y of the system ’ s operation. MA TE Screens DC T oday min/SOC 76% In 347AH 9.040kWH Out 331AH 8.510kWH Bat 16AH 0.530kWH • Minimum SOC today (since midnight) • In: Amp hours and kiloWatt hours fr om sources today • Out: Amp hours and kiloW att hours output by [...]
-
Pagina 19
18 DC BA T 12.5V 99% Bat -0.6A 0.000kW Net -4AH 00.7kWH Days Since Full 4.8 The fourth SUM screen shows: • Batter y voltage • The current state- of- charge • Batter y readings show the instantaneous amp , amp hour , kilowatt, and k ilowatt hour gures. When compar ing the amp hours reading to “FULL, ” the gure is charge factor comp[...]
-
Pagina 20
19 The second METER screen shows the accumulated amp hours and kilowatt hours for each shunt. Pr ess the <DOWN> soft key to view the next METER screen. This screen shows the number of remov ed amp hours and watt hours as measured by SHUNT A. P ress the <DO WN> soft ke y to view the SHUNT A charged screen. The fourth meter screen display[...]
-
Pagina 21
20 Pr essing the <DOWN> soft key brings up the SHUNT C charged scr een. Pr essing the <DOWN> soft key leads to the end of the meter menu Pr ess the <ST A TUS> soft k ey to return to the ST A TUS screen. Pr ess the <SHUNT> soft key to view the amps and kilowatts removed and charged in each shunt Pr essing the <DOWN> sof[...]
-
Pagina 22
21 Displaying the kilowatts removed provides the user with more precise ener gy usage information. This gure can be returned to 0 b y pressing the <RESET> soft ke y . P ress the <DOWN> soft key to view the max charged scr een. SHUNT A shows a maximum of 39.8 amps charged. Pr essing the <RESET> soft key returns this value to 0.[...]
-
Pagina 23
22 ST A TUS/DC/BA T T provides the number of days since the batter y last met its charge parameters . P ress the <RESET> soft ke y to restart the timer . Press the <DOWN> soft key to view the next batter y status screen. batttery min(imum) displays the minimum batter y voltage since it was last reset by the user . Pr essing the <RESE[...]
-
Pagina 24
23 lifetime kAH removed shows the t otal k ilowatt amp hours removed fr om the batter y . This is essentially an “ odometer ” for batter y usage. P ress the <DO WN> soft ke y to continue. ST A TUS/DC/BA T T lifetime kAH removed 5 DOWN UP RESET TOP Pr ess the rst two soft ke ys to return to the MAIN menu . ST A TUS/DC/BA T T ----------[...]
-
Pagina 25
24 Shunt 1 is, by default, enabled or active when the FX is powered up . P ressing the <DIS> soft key disables the rst shunt. Pr essing the <DOWN> soft key leads to the shunt 2 mode and shunt 3 mode screens. These shunts are disabled at power-up and ar e enabled by pressing the <EN> soft key . When the setup for all shunts has[...]
-
Pagina 26
25 The return amps screen allows the user t o set the end of charge amps using the <INC> and <DEC> soft keys. Pr ess the <DOWN> soft key to view the batter y charge screen. ADV/DC/CHARGE-------------- return amps DOWN INC DEC TOP ADV/DC/CHARGE--------------- battery charge DOWN INC DEC TOP Pr ess the <CHARGE> soft key. ADV/D[...]
-
Pagina 27
26 ADV/DC/PAGE 1---------------- choose category ADV BA T SHUNT PG2 Pr ess the <PG2> soft key. Use the low volts scr een and the <INC> and <DEC> soft keys to control the A UX by a low voltage value. P ress the <DOWN> soft key to view the SOC high % screen. ADV/DC/AUX LOW VOL T ------ low volts vdc DOWN INC DEC TOP Pr ess the[...]
-
Pagina 28
27 T o activate the invert logic func tion, press the <Y ES> soft k ey ; press the <NO> soft key to deactivate it. Press the <DO WN> soft ke y to view the last A UX screen. ADV/DC/AUX/INVER T --------- invert logic DOWN YES NO TOP Change the SOC low % values using the <INC> and <DEC> soft ke ys. P ress the <DO WN>[...]
-
Pagina 29
28 Pr essing the <RESET> soft key resets the FLEXnet DC to its factor y default settings. Pr essing the <CLR> soft key clears the data log memor y . ADV/DC/AUX/PAGE 3---------- choose category: PG2 RESET CLR MAIN Pr ess the <PG3> soft key. ADV/DC/PAGE 2----------------- choose category: PG1 CHARGE AUX PG3[...]
-
Pagina 30
29 T echnical Not es Battery Charge F actor (BCF) Some energy is lost both when rechar ging and discharg ing a batter y . The FLEXnet DC compensates for these losses by discounting the amp-hours charg ing the batter y , meaning it doesn ’t count every hour used for rechar ging as actually recharg ing. Some of them are lost due to heat and gassing[...]
-
Pagina 31
30 Revision.2007-08-29 2- Y ear Limited W arranty FLEXnet Pr oducts OutBack P ower Systems , Inc. (“OutBack ”) provides a two year (2) limited warranty (“ Warranty ”) against defects in materials and workmanship for its FLEXnet products (“Pr oducts”) if installed in xed location applications. F or this Warranty to be valid, the P ro[...]
-
Pagina 32
31 T o request warranty ser vice, you must contact OutBack T echnical Ser vices at (360) 435-6030 or suppor t@outbackpower .com within the e ective warrant y period. If warrant y ser vice is required , OutBack will issue a Return Material Authorization (RMA) number . A request for an RMA number r equires all of the following inf ormation: 1. P r[...]
-
Pagina 33
32 T w o Y ear Limited FLEXnet DC W arr anty Registr ation Limited W arranty Registration Complete this form to request a Limited W arranty and return it to: Outback P ower Systems Inc. 19009 62nd Ave . NE Arlington, W A 98223 Note: A Limited Warranty Cer ti cate will only be issued if this Registration Car d is received by OutBack within 90 day[...]
-
Pagina 34
900-0093-01-00 REV B European Sales O c e C/ Castelló , 17 08830 - Sant Boi de Llobregat BARCEL ONA, España Phone: (+34) 93.654.9568 Corporate O c e 19009 62nd Av enue NE Arlington, W A USA Phone: (+1) 360.435.6030 ww w .outback power .com[...]