Vai alla pagina of
Manuali d’uso simili
-
Universal Remote
Panasonic FP0 Series
27 pagine 1.4 mb -
Universal Remote
Panasonic 800EUC
8 pagine 0.37 mb -
Universal Remote
Panasonic CY-RM850
8 pagine 0.37 mb -
Universal Remote
Panasonic AWCB400N
24 pagine 0.9 mb -
Universal Remote
Panasonic AW-CB400L
104 pagine 1.42 mb -
Universal Remote
Panasonic AW-RC600P
24 pagine 2.14 mb -
Universal Remote
Panasonic CZ-RWSU2U
26 pagine 1.19 mb -
Universal Remote
Panasonic CZ-RWSK1U
26 pagine 1.19 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Panasonic FP0 Series. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Panasonic FP0 Series o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Panasonic FP0 Series descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Panasonic FP0 Series dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Panasonic FP0 Series
- nome del fabbricante e anno di fabbricazione Panasonic FP0 Series
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Panasonic FP0 Series
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Panasonic FP0 Series non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Panasonic FP0 Series e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Panasonic in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Panasonic FP0 Series, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Panasonic FP0 Series, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Panasonic FP0 Series. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
FP0 Series Programmable Controller P anasonic ... the new name f or CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net 10/2004[...]
-
Pagina 2
2 FP0 – Super Compact PLC Incredibly small, alone or even as multiple combined units A control unit a mere 25mm in width. Even expanded to I/O 128 points, the width is still only 105mm. The attachment area is the smallest in its class. The control unit's dimensions are: W25* x H90 x D60mm. Also, the I/O unit can be expanded to a maximum of 1[...]
-
Pagina 3
Either 10 Points or the Maximum of 128 Points Y ou save this much space! 3 The expansion unit can be attached easily without any cables. The expansion unit can easily be attached directly to the control unit. Special expansion cables, backplanes, and so forth, are unnecessary as the expansion unit employs a stacking system that uses expansion conne[...]
-
Pagina 4
4 FP0 CPU Units A rich line-up of both single and combined units = + =+ =+ =+ =+ + + =+ + =+ + = +++ = +++ 22 Input 12 Output 10 14 Input 8 Output 6 8 Input 4 Output 4 26 Input 14 Output 12 10 Input 6 Output 4 16 Input 8 Output 8 30 Input 16 Output 14 14 Input 8 Output 6 16 Input 8 Output 8 34 Input 18 Output 16 10 Input 6 Output 4 16 Input 8 Outpu[...]
-
Pagina 5
FP0 Expansion Units Choose the number of I/O points to suit the application 5 Combinations with transistor output type – Examples = + =+ =+ =+ =+ + + =+ + =+ + = +++ + = +++ 48 Input 24 Output 24 32 Input 16 Output 16 16 Input 8 Output 8 16 Input 8 Output 8 32 Input 16 Output 16 64 Input 32 Output 32 32 Input 16 Output 16 32 Input 16 Output 16 80[...]
-
Pagina 6
6 FP0 – Impressive Capabilities High specifications for both speed and capacity 0.9µs per basic instruction. Pulse catch and interrupt input functions meet the need for high-speed response. High-speed execution Execution speed of 0.9µs per basic instruction. 500 steps program yields a scanning time of 1ms, which means the FP0 boosts the fastest[...]
-
Pagina 7
FP0 – Impressive Capabilities FP0 functions 7 Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pulse output function (For transistor output type only) The unit comes equipped with 2 channels for the output of up to 10kHz pulses (5kHz during 2-channel output). Since these two channels can be separately[...]
-
Pagina 8
8 FP0 Communication Serial interfaces and modem compatible Programming interface TOOL-Port (also for communication) In Computer Link mode, this port offers access to the entire FP0 memory area. For example during data exchange between a host PC running SCADA software and an FP0 PLC, the Windows ® based MEWNET -DDE Server assumes total control of t[...]
-
Pagina 9
FP0 Communication Easier maintenance than ever before 9 Maintenance saving ■ Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments. ■ Backup battery unnecessary The program memory uses EEPROM. The program and device contents can be stored without a[...]
-
Pagina 10
10 FP0 PROFIBUS DP Slave or Remote I/O Unit For cost effective control of distributed field device The FP0 DPS2 can operate either as a DP slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected. A DIP switch can be used to switch between the two modes: Mode 1: DP-Slave module. Connect the FP0 or [...]
-
Pagina 11
11 FP0 S-LINK Unit Connects directly to the S-LINK for reduced wiring Wire-saving The use of wires is greatly reduced and the number of connecting terminal blocks is minimized, resulting in large reduction in cost, as well as, the waste generated during wiring. Space effective S-Link devices are compact. The control box can be mounted in a tight sp[...]
-
Pagina 12
12 FP0 MEWNET -F Unit Networking units The FP0 can be used as a slave station for MEWNET -F (remote I/O system) by adding I/O link unit. MEWNET -F is a reduced-wiring remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling. By adding an I/O link unit to the FP0, you can link master station PLC and FP0 inpu[...]
-
Pagina 13
The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user friendly temperature acquisition using standard thermocouples with high precision. ■ Up to three units can be added to each control unit, enabling temperature control of up to 24 channels. ■ The temperature data obtained using the thermocouple is converted to the digital value to [...]
-
Pagina 14
14 Analogue Signal Processing FP0 Analogue Units FP0-A21 2 Inputs/1 Output FP0-A80 8 Inputs ■ Multimode A/D, D/A conversion ■ High resolution: 12-bit V oltage, current and temperature selectable ■ 2 analogue inputs (FP0-A21): ■ High conversion speed -10 to + 10V , 0 to 5V , 0 to 20mA, FP0-A04V , FP0-A04I: 500µs 8 analogue inputs (FP0-A80):[...]
-
Pagina 15
Analogue Signal Processing FP0 Analogue Units 15 Item Description Rated operating voltage Operating voltage range 24VDC 21.6 to 26.4VDC Rated current consumption FP0-A80: 60mA or less, FP0-A21/A04V : 100mA or less, FP0-A04I: 130mA or less Ambient temperature 0 ° C to + 55 ° C Storage temperature -20 ° C to + 70 ° C Size 90 x 25 x 60mm Weight ap[...]
-
Pagina 16
16 FP0 RTD Input Expansion Unit User friendly acquisition of temperatures with high precision Features FP0-R TD6 6 channels ■ The module can be easily installed in an existing system: Special connection cables, backplanes, and so forth are unnecessary as the expansion unit employs a stacking system that uses expansion connectors and lock levers o[...]
-
Pagina 17
Item Description Rated operating v oltage 24 VDC Operating v oltage range 21.6 to 26.4 VDC Allow able no voltage time 10 points, 14 points type 5ms (at 21.6 V), 10ms (at 24 V) 16 points, 32 points, S-LINK type 10ms (at 21.6 V / 24 V) Ambient temperature 0 ° C to +55 ° C Storage temperature -20 ° C to +70 ° C Ambient humidity 30 to 85% RH (Non-c[...]
-
Pagina 18
18 FP0 Series Specification tables Item Description Programming TOOL-Port Communication COM-Port RS232, mini DIN socket (5 pin), 9600 or 19200 BAUD, (8 data bits, odd parity , 1 stop bit), Computer link for programming and communication with MEWTOCOL.COM, user configurable modem connection RS232 (SD, RD, GND) 3 way screw terminal, 300 to 19200 BAUD[...]
-
Pagina 19
19 Control FPWIN Pro PLC programming software conforming to IEC 61131-3 FP Programmer II V er. 2 Programming cable AFC8513D Programming cable AFC8523 Programming software Connect with RS232C cable FP0 The most important highlights at a glance: ■ Reuse of ready made functions and function blocks saves time for programming and debugging ■ 5 progr[...]
-
Pagina 20
20 Control FPWIN GR PLC programming software for easy operation Program status display Function instruction list Classified by type, function commands can be selected from the displayed list. (Simple help included.) Menu Program display T ool bar Access often-used functions using icons. Function bar Provides information regarding command input and [...]
-
Pagina 21
Control CommX, PCW A Y , OPC Server V isualisation software for ready made or customised solutions 21 The connection in ActiveX technology . ■ Connects your Visual Basic application to Matsushita PLCs. ■ Gives you the possibility to easily develop highly customised control solutions. ■ Create your own application very quickly by simply adding[...]
-
Pagina 22
Notes: ■ A power cable (order number AFP0581) is enclosed with the control unit and the relay output type upgrade units (T ransistor output type upgrade units do not require a power cable). ■ T wo Phoenix terminals (9-pin) are needed with the relay output type terminal type. A 2.5mm width screwdriver is needed for the wiring. Have ready a dedic[...]
-
Pagina 23
FP0 Analogue and Networking Units Products and order numbers 23 3 points Input 2 points T erminal type Order number: FP0-A21A T erminal type Order number: FP0-A80A Output 1 points 8 points Input 8 points 4 points Output 4 points T erminal type Order number: FP0-A04V T erminal type Order number: FP0-A04I 4 points Output 4 points Input 85 to 265V AC [...]
-
Pagina 24
Terminal screwdriver Necessary when wiring relay output type & terminals (Phoenix). Attachment example Wiring tools Parts for attachment I/O cables & networks Order number : AFP0806 Slim attachment plate model Screw-stop attachment plate. Slim model. Order number : AFP0803 (set of 10) Attachment example DIN rail attachment example Flat atta[...]
-
Pagina 25
Programming T ools and Current Consumption List Products and order numbers 25 Control Control Made in Germany Made in Germany Matsushita Electric Works, Ltd. 1995-2000 1995-2000 Matsushita Electric Works, Ltd. FPWIN GR FPWIN GR Ver.2 Ver.2 Control Control Made in Germany Made in Germany Matsushita Electric Works(Europe)AG 1995-2000 1995-2000 Matsus[...]
-
Pagina 26
26 FP0 Series Power Supplies ■ Incredibly small size: - FP0 power supply: 90 x 60 x 30.4mm - FP power supply: 115 x 75 x 42mm ■ Maximum output current: - FP0 power supply: 0.7A (24VDC) - FP power supply: 2.1A (24VDC) ■ Multiple voltage input: 85 to 265V AC ■ Optimal protection: overvoltage, overcurrent, overheating, etc. ■ Global approval[...]
-
Pagina 27
FP0 Product Overview Order numbers 27 1. Control Units Product Name Part Number FP0-C10RS, 6 Inputs / 4 Outputs (p+n / Relay) FP0-C10RSA FP0-C10CRS, 6 Inputs / 4 Outputs (p+n / Relay), RS232 COM-P or t Interface FP0-C10CRSA FP0-C14RS, 8 Inputs / 6 Outputs (p+n / Relay) FP0-C14RSA FP0-C14CRS, 8 Inputs / 6 Outputs (p+n / Relay), RS232 COM-P or t [...]