Vai alla pagina of
Manuali d’uso simili
-
Ventilation Hood
Panasonic FV-30NLF1
9 pagine 0.65 mb -
Ventilation Hood
Panasonic FV-07VB1
8 pagine 2.59 mb -
Ventilation Hood
Panasonic FV-05-11VKS1
12 pagine 1.83 mb -
Ventilation Hood
Panasonic FV-08VKS2
8 pagine 1.99 mb -
Ventilation Hood
Panasonic FV-15VQL5
11 pagine 1.42 mb -
Ventilation Hood
Panasonic FV-11VQ5
12 pagine 3.23 mb -
Ventilation Hood
Panasonic FV-05VQ5
12 pagine 3.23 mb -
Ventilation Hood
Panasonic FV-08VKSE3
8 pagine 1.71 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Panasonic FV-05-11VK1. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Panasonic FV-05-11VK1 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Panasonic FV-05-11VK1 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Panasonic FV-05-11VK1 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Panasonic FV-05-11VK1
- nome del fabbricante e anno di fabbricazione Panasonic FV-05-11VK1
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Panasonic FV-05-11VK1
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Panasonic FV-05-11VK1 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Panasonic FV-05-11VK1 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Panasonic in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Panasonic FV-05-11VK1, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Panasonic FV-05-11VK1, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Panasonic FV-05-11VK1. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
FV-05-11VKS1 FV-05-11VK1 FV-11-15VK1 Model No. Thank you for purchasing this Panasonic product. FV-05-11VKS 1 F V-05-11VK1 FV-11-15VK1 GENERAL SAFETY INFORMATION PLEASE READ PRIOR TO INSTALLING THIS FAN DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) MOTION (PLUG ‘N PLAY FU[...]
-
Pagina 2
2 Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fast[...]
-
Pagina 3
3 Do not install this ventilating fan where interior room tempera ture may exceed 104°F(40°C). Make sure that the electric service supply voltage is AC 120V, 60Hz. Follow all local electrical and safety codes, as well as the Na tional Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Always disconnect the power source before [...]
-
Pagina 4
4 4 PLEASE READ PRIOR TO INSTALLING THIS FAN These fans are also built to take care of the homeowner’s spot ventilation needs when the room is occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VK1 and 110 CF[...]
-
Pagina 5
1 1 2 Part name Appearance Quantity Installation instructions Self-drilling screw Warranty sheet Part name Appearance Quantity Grille 4 4 SUPPLIED ACCESSORIES 5 DIMENSIONS WIRING DIAGRAM Part name Blade Grille 6 9 10 11 12 Junction box Adaptor Part name No. No. Motion sensor location (FV-MSVK1 not included) Multi-Speed module (FV-05-11VKS1 only, ot[...]
-
Pagina 6
6 MODEL MODEL 05-11 11-15 110 1 50 130 50 110 80 A IR V O L UM E C FM ( ) All the WhisperGreen Select base models of fans come with Pick-A-Flow speed options. The Pick-A-Flow switch on the face of all WhisperGreen Select fans allows the option to choose 50 – 80 – 110 CFM for the FV-05-11VK1, FV-05-11VKS1 or 110 – 130 – 150 CFM for the FV-11[...]
-
Pagina 7
7 FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of c[...]
-
Pagina 8
8 INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES) Base PCB box Slot INSTALLATION (NEW CONSTRUCTION) Connector cover 2 2 3 3 Squeeze tabs on the Clasp to remove. Squeeze, insert and release the tabs on Clasp to replace. 1. Remove the connector cover 2. Plug in the specified devices to Base PCB box and fix to the slot, till hear the sound installed in[...]
-
Pagina 9
CAUTION CAUTION 11. (Fig.9) Insert the grille mounting spring on the wiring side into the slot. 12. (Fig.9). Plug in the specified devices as your choice (refer to installation on page 8). Insert the motion sensor (FV-MSVK1 only) or LED night light (FV-NLVK1 only) into slot of the grille. Fix the lead wire into the clasp 9 8. Insert fan body and sl[...]
-
Pagina 10
10 INSTALLATION (RETROFIT) INSTALLATION (NEW CONSTRUCTION) CONTINUED CAUTION Fig.10 Fig.11 Grille Grille Ceiling Mounting spring 14. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.11) Mount grille carefully so that lead wire is not pinched. Ceiling Gloves 13. Adjust Pick-A-Flow switch; if used, adjust the[...]
-
Pagina 11
11 Fig.17 Fig.18 Fig.19 2. Clean grille. (Don’t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth) (Fig.17) 3. The grille should be dry after cleaning. 4. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.18) 5. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry wit[...]
-
Pagina 12
Panasonic corporation 2014 X0114-202 4 1 5 V K 10420B Two Riverfront Plaza, Newark, NJ 07102 Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292[...]