Vai alla pagina of
Manuali d’uso simili
-
Network Card
Patton electronic 2020N
7 pagine 0.09 mb -
Network Card
Patton electronic 3101RC
2 pagine 0.18 mb -
Network Card
Patton electronic 2290 Series
2 pagine 0.17 mb -
Network Card
Patton electronic 1002
8 pagine 0.58 mb -
Network Card
Patton electronic 2172
22 pagine 0.39 mb -
Network Card
Patton electronic 3P-MF9
12 pagine 0.45 mb -
Network Card
Patton electronic NetLink-E1 2715
20 pagine 0.12 mb -
Network Card
Patton electronic 3012/V24, 3014/V24, 3018/V24
16 pagine 0.19 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Patton electronic 1090. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Patton electronic 1090 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Patton electronic 1090 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Patton electronic 1090 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Patton electronic 1090
- nome del fabbricante e anno di fabbricazione Patton electronic 1090
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Patton electronic 1090
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Patton electronic 1090 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Patton electronic 1090 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Patton electronic in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Patton electronic 1090, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Patton electronic 1090, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Patton electronic 1090. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
USER MANUAL MODEL 1090 High Speed Synchronous Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part# 07M1090-B Doc# 03201 1UB Revised 5/26/98 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business. I tr[...]
-
Pagina 2
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1090 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized [...]
-
Pagina 3
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor . If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics T echnical Support at (301[...]
-
Pagina 4
SWITCH SET S1 The configuration switches on S1 set clock source, RTS/CTS delay , carrier control, loopback tests. The default settings are summarized in Figure 3 (above). S1-1 and S1-2: Clock Source Switches S1-1 and S1-2 are set in combination to determine the source of timing for the Model 1090. S1-1 S1-2 Setting On On Internal On Off Receive rec[...]
-
Pagina 5
S1-8: V .54 Enable / Disable The setting for switch S1-8 determines whether the Model 1090 will respond when it receives the V .54 sequence. If you suspect the Model 1090 may be getting tricked into the loopback test by false detection of user data, you can try setting this to “Disable.” S1-8 Setting On Disabled Off Enabled SWITCH SET S2 The se[...]
-
Pagina 6
When connecting two Model 1090’s, it is necessary to use a crossover cable. The diagram below shows how a crossover cable should be constructed. RJ-45 Cable (4-Wire) SIGNAL PIN# PIN# SIGNAL XMT+ 1 -----------------------8 RCV - XMT - 2 -----------------------7 RCV+ GND* 4 -----------------------5 GND* GND* 5 -----------------------4 GND* RCV+ 7 -[...]
-
Pagina 7
4.2.2 CONNECTION TO A “DTE” DEVICE The serial port on most QuickConnect™ interface modules (all except the X.21 module) is hard-wired as a DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host. When making the connection to your DTE device, use a straight through cable of the shortest possible length—we r[...]
-
Pagina 8
5.0 OPERA TION Once the Model 1090 is properly configured and installed, it should operate transparently . This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP Before applying power to the Model 1090, first be sure that you have read Section 4.3 , and that the your power source [...]
-
Pagina 9
B. V erify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit. C. Perform a BER (bit error rate) test on each unit using a separate BER tester . If the BER test equipment indicates no faults but the data terminal indicates a fault, follow the manufacturer[...]
-
Pagina 10
5.3.4 V .52 BER TEST GENERA TOR The Model 1090 has a built-in test pattern generator and detector . It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog, Remote Digital or Local Digital Loopbacks. The following example requires two operators: one to initiate and monitor the test at the local Model 1090, an[...]
-
Pagina 11
APPENDIX B 1090 CABLE RECOMMENDA TIONS The Patton Model 1090 operates at frequencies of 160 kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics: Wire Gauge Capacitance Resistance 19 A WG 83nF/mi or 15.72 pF/ft. .0163 Ohms/ft. 22 A WG 83nF/mi or 15.72 pF/ft. .0326 Ohms/ft. 24 [...]
-
Pagina 12
APPENDIX D M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Ready) L LLB (Local Line Loop) M TM (T est Mode) N RDL (Remote Digital Loop) P TD(T ransmit Data) R RD (Receive Data) S TD/ (T ransmit Data-B) T RD/ (Rec[...]
-
Pagina 13
APPENDIX D 1090 INTERF ACE PIN ASSIGNMENT T ABLES M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Ready) L LLB (Local Line Loop) M TM (T est Mode) N RDL (Remote Digital Loop) P TD(T ransmit Data) R RD (Receive Da[...]
-
Pagina 14
APPENDIX D DB-15F Connector-DCE Setting (X.21 Interface) Pin # Signal 1 . . . . . . . . . . . . Frame Ground 2 . . . . . . . . . . . . T ( T ransmit Data-A) 3 . . . . . . . . . . . . C (Control-A) 4 . . . . . . . . . . . . R (Receive Data-A) 5 . . . . . . . . . . . . I (Indication-A) 6 . . . . . . . . . . . . S (Signal Element T iming-A) 7 . . . . [...]