Vai alla pagina of
Manuali d’uso simili
-
Portable Generator
Porter-Cable BSV750
24 pagine 0.8 mb -
Portable Generator
Porter-Cable D28362-031-0
22 pagine 0.29 mb -
Portable Generator
Porter-Cable H650IS-W
24 pagine 0.33 mb -
Portable Generator
Porter-Cable A02871-043-0
24 pagine 1.69 mb -
Portable Generator
Porter-Cable PH350IS
22 pagine 0.45 mb -
Portable Generator
Porter-Cable T550
20 pagine 0.67 mb -
Portable Generator
Porter-Cable H1000IS
28 pagine 1.36 mb -
Portable Generator
Porter-Cable H451CS
20 pagine 0.27 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Porter-Cable CH350CS. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Porter-Cable CH350CS o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Porter-Cable CH350CS descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Porter-Cable CH350CS dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Porter-Cable CH350CS
- nome del fabbricante e anno di fabbricazione Porter-Cable CH350CS
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Porter-Cable CH350CS
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Porter-Cable CH350CS non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Porter-Cable CH350CS e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Porter-Cable in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Porter-Cable CH350CS, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Porter-Cable CH350CS, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Porter-Cable CH350CS. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Part No. D21269-007-0 Generators Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 21 FRANÇAISE: P AGE 41 IMPORT ANT [...]
-
Pagina 2
2 — ENG This product is not equipped with a spark arresting muf fler . If the pr oduct will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a vi[...]
-
Pagina 3
3 — ENG WARRANTY Porter-Cable Corporation 4825 Highway 45 North P .O. Box 2468 Jackson, TN 38302-2468 1-888-559-8550 PORTER-CABLE CORPORA TION warrants to the original pur chaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defec- tive p[...]
-
Pagina 4
4 — ENG Attempting to connect generator directly to the electrical system of any building structure. Back feeding electricity through a building’ s electrical system to the outside utility feed lines could en- danger repair persons attempting to restore service. Attempting to connect to the incoming utility service could result in electrocu- ti[...]
-
Pagina 5
5 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. Use of worn, damaged, undersized or ungrounded extension cords. Placing generator on or against highly conductive surface, such as a steel walkway or metal roof. Improper connection of items to generator . Operation of unit when damaged, or with guards or panels[...]
-
Pagina 6
6 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF FIRE T ur n engine of f and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extin- guisher certified to handle gasoline or fuel fires. Add fuel to tank in well ventilated area. Make sure there are no sources of igniti[...]
-
Pagina 7
7 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF BREA THING - INHALA TION HAZARD Operate generator in clean, dry , well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or ani- mals. Keep children, pets and oth- ers [...]
-
Pagina 8
8 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. • Review and understand all of t he operating instructions and warnings in this manual. • Become familiar with the operation and controls of the generator . Know how to shut it off quickly . • Equip area of operation with a fire extinguisher certified to h[...]
-
Pagina 9
9 — ENG RISK FROM LIFTING HAZARD HOW TO PREVENT IT WHA T COULD HAPPEN The generator is too heavy to be lifted by one person. Obtain assistance from others before you try to move it. Serious injury can result from attempt- ing to lift too heavy an object. Lifting a very heavy object. READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA T[...]
-
Pagina 10
10 — ENG Extension Cord Wire Gauge Chart Amperage *Up to 20 amp draw Up to 30 amp draw Cord Length 0 to 100 ft. 0 to 100 ft. Wire Gauge Size 12 ga. 10 ga. *NOTE: When amperage exceeds 20 amps; a 12 gauge extension cord should not be used for long distances. Extension Cords When using an appliance or tool at a considerable distance from the genera[...]
-
Pagina 11
11 — ENG OPERA TION KNOW YOUR GENERA TOR Read this General Manual and Safety Rules before operation of your Generator . Compare the illustration in your parts manual with your generator to familiarize yourself with the location and use of various controls. Save all manuals for future references. IMPORT ANT : Exceeding the rated capacity of your g[...]
-
Pagina 12
12 — ENG 2. Check fuel level and fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Never fill fuel tank completely . Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel e[...]
-
Pagina 13
13 — ENG TO ST AR T THE ENGINE Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 1. Open the fuel shut-off valve on tank and engine. 2. Move the choke control located on the engine to "CHOKE" position. NOTE: No choke is required on warm engines. Make sure[...]
-
Pagina 14
14 — ENG MAINTENANCE Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter , mor e often if operated in extreme dusty or dirty conditions. Note 2: Check oil after 5 hours of operation CUSTOMER RESPONSIBILITIES T ABLE MAINTENANCE T ASK Before each use X Every 25 Hours or Every Season See Note 2 X Every 50 H[...]
-
Pagina 15
15 — ENG STORAGE If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage. Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a fur nace, water heater , clot[...]
-
Pagina 16
16 — ENG Never exceed the rated capacity of your generator . Serious damage to the generator or appliance could result from an overload. 1. S tarting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool. 2. There are two types of electrical appliances that can be powered[...]
-
Pagina 17
17 — ENG ST AR TING W A TT AGE REQUIREMENTS 1. Some appliances and tools will list on the motor name plate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage: V olts X Amp = W atts 120 volts x 10 amps = 1200 watts 2 . T o determine the approximate starting wattage requi[...]
-
Pagina 18
18 — ENG HOUSEHOLD W A TT AGE CALCULA TOR W A TT AGE CALCULA TIONS APPLIANCE OR LOAD DEVICE* REFRIGERA TOR/ FREEZER 800 SMALL REFRIGERA TOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA TE MICROWA VE SP ACE HEA TER 2400 1000 3 2 LIGHTING 60 WA TT BULBS 75 WA TT BULBS 100 WA TT BULBS 300 WA TT BULBS ELECTRIC LOAD GRAND TOT AL [...]
-
Pagina 19
19 — ENG TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine will not start No electrical output Repeated circuit breaker tripping Generator overheating No auto idle DC does not have power with the circuit breaker depressed 1. Low on fuel or oil. 2. Ignition switch in "Off" position. 3. Faulty spark plug. 4. Choke in wrong position. 5[...]
-
Pagina 20
20 — ENG EN G IN E GA S WA T T AGE WIRI NG EN GI N E Allow the g e nerato r to ru n 5 minutes at no load f o r the eng ine a nd the g enhea d to s ta b iliz e. OP ERA T I ON M ake su r e t h e ade qu a t e siz e o f e xt e n sio n co r d i s u s e d. Re fe r t o t h e G r o u n din g Ins truc ti ons /E x t e ns i on Cord s e ct i on of the o w ne[...]