Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 manuale d’uso - BKManuals

RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155
- nome del fabbricante e anno di fabbricazione RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio RAD Data Communications in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso RAD Data Communications 10/100BaseT to STM-1/OC-3 Converter RIC-155. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    Installation and Operation Manual RIC -155 10/100BaseT to S TM-1/OC-3 Converter Version 1.12[...]

  • Pagina 2

    [...]

  • Pagina 3

    RIC-155 10/100BaseT to STM-1/OC-3 Converter Version 1.12 Installation and Operation Manual Notice T h i s m a n u a l c o n t a i n s i n f o r m a t i o n t h a t i s p r o p r i e t a r y t o R A D D a t a C o m m u n i c a t i o n s L t d . ( " R A D " ) . N o part of this publication may be reproduced in any form whatsoever without pr[...]

  • Pagina 4

    Limited Warranty RAD w arr ant s to D IS TRIB UTOR tha t th e har dwa re i n th e RIC-155 to be de liv ered her eun der sha ll be free of defects in material and workmanshi p under no rmal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equip[...]

  • Pagina 5

    General Safety Instructions The following in structions ser ve as a general guide for the safe installation and operation of telecommunications products. Addition al i nstructions, if appl icable, are included ins ide the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding p[...]

  • Pagina 6

    Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the powe r switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the vo ltages levels are usually not hazardou[...]

  • Pagina 7

    Connection of Data and Telecommunications Cables Data and telecommunicatio n interfaces ar e classified accor ding to their safety status. The following table list s the status of several standard in terfaces. If the st atus of a given port differs from the standard one, a no tice will be given i n the manual. Ports Safety Status V.11, V.28, V.35, [...]

  • Pagina 8

    To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-buildin g or non-exposed wiring or cabling only. In such cases, a notice will be [...]

  • Pagina 9

    Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte to utes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR- 22) This is a class A product. In a domestic envir[...]

  • Pagina 10

    Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: RIC-155 conforms to the following standard(s ) or other normative document(s): EMC : EN 55022:1998 Information technology equipment – Radio disturbance[...]

  • Pagina 11

    Configuring RIC-155 1 Quick Start Guide Installation of RIC-155 should be carried out only by an experienced technician. If you are familiar with RIC- 155, use this gu ide to prepare the units for operation. 1. Installing RIC-155 Connecting the Interfaces 1. Connect the STM-1/OC-3c equipment to the fiber optic or BNC rear panel connectors. 2. Conne[...]

  • Pagina 12

    Quick Start Guide RIC-155 Installation and Operation Manual 2 Configuring RIC-155 4. When the ALM LED (red) starts blinking, press <Enter> several times. RIC-155 automatically adjusts itself to the current terminal baud rate an d responds with a string of dots. 5. Type several dots. When the hardware initial ization is completed, the SIG and [...]

  • Pagina 13

    RIC-155 Installation and Operation Manual i Contents Chapter 1. Introduction 1.1 Overview ..................................................................................................................... 1-1 Versio ns ....................................................................................................................... ........[...]

  • Pagina 14

    Table of Contents ii RIC-155 Installation and Operation Manual Enabling and Disabl ing Pop-up Alarms .................................................................................. 4-8 4.3 Configuring the Physical P orts ...................................................................................... 4-9 Configuring the Ethe rnet Inte rfac[...]

  • Pagina 15

    Overview 1-1 Chapter 1 Introduction 1.1 Overview RIC-155 is a converter that enables si mple and efficient connection of Fast Ethernet traffic over STM-1/OC-3c lines. Equipped with a 10/100BaseT and fiber optic or coaxial STM-1 interf ace, RIC-155 serves as cost-effective alternative to ATM devices and routers. The RIC-15 5’s packet-over-SONET en[...]

  • Pagina 16

    Chapter 1 Introduction RIC-155 Installation and Operation Manual 1-2 Overview Features 10/100BaseT Interface RIC-155 Fast Ethernet interface operatio n conforms to the IEEE 802.3u, 802.3x and 802.1p standar ds, including VLAN applicat ions. The Fast Ethernet interface supports the following functions: • Four levels of QoS, according to ToS or 802[...]

  • Pagina 17

    RIC-155 Installation and Operation Manual Chapter 1 Introduction Overview 1-3 Management Setup, control and monitoring o f status and diagnostics information can be performed using one of the following methods: • ASCII terminal connected to th e V.24/RS-232 DTE control port • Telnet host via dedicated Ethernet ma nagement port • PC running a [...]

  • Pagina 18

    Chapter 1 Introduction RIC-155 Installation and Operation Manual 1-4 Physical Description 1.2 Physical Description RIC-155 is a non-modular standalone unit, intended for tabletop or 19” rack installation. Figure 1-2 illustrates a 3D view of the RIC-155 unit. Figure 1-2. R IC-155 3D View The front panel includes seven LEDs, which display the statu[...]

  • Pagina 19

    RIC-155 Installation and Operation Manual Chapter 1 Introduction Functional Description 1-5 1.3 Functional Description This section contains func tional descriptions of the RIC-155 circ uit blocks, shown in Figure 1-3 . SD H/ SO NET Link Main Card Ether net Netw ork Interface CPLD SDH/SONET Fram er Para ll el CP U Int erf ace MDIO/M DC Inter fa ce [...]

  • Pagina 20

    Chapter 1 Introduction RIC-155 Installation and Operation Manual 1-6 Technical Specifications • Fiber optic/electrical interface provides connection to the fiber optic or coaxial cables. • CPU controls the RIC-155 operation. It includes a microprocessor, flash memory, and SRAM. • Power supply provides 5V and +3.3V voltage to the RIC-155 inter[...]

  • Pagina 21

    RIC-155 Installation and Operation Manual Chapter 1 Introduction Technical Specifications 1-7 Management V.24/RS-232 ASCII terminal via V.24/RS-232 serial DTE port Ethernet Telnet, Web browser or RADview via a MNG port (out-of- band) or DATA port (i nband) Monitoring STM-1/OC-3c Optical input signal Input signal monitoring based on received B 2 err[...]

  • Pagina 22

    Chapter 1 Introduction RIC-155 Installation and Operation Manual 1-8 Technical Specifications[...]

  • Pagina 23

    Site Requirements and Prerequisites 2-1 Chapter 2 Installation and Setup 2.1 Introduction This chapter describes installation and setup procedures for the standalone RIC-155 device. After installing the unit: • Refer to Chapter 3 for the operating instructions. • Refer to Chapter 4 for the detailed system conf igura tion procedures using an ASC[...]

  • Pagina 24

    Chapter 2 Installation and Setup RIC-155 Installation and Operation Manual 2-2 Connecting the Interface Cables 2.3 Package Contents The RIC-155 package includes the followi ng items: • One RIC-155 unit • Technical documentation CD • AC power cord or DC po wer supply connector kit • RM-35 rack mount kit (if ordered). 2.4 Connecting the Inter[...]

  • Pagina 25

    RIC-155 Installation and Operation Manual Chapter 2 Installation and Setup Connecting the Power Cable 2-3 2.5 Connecting the Power Cable To connect RIC-155 to the power source, refer to the appropriate section below, depending on your versio n of the unit (AC or DC ). Before switching on this unit and connecting or disconnecting any other cable, th[...]

  • Pagina 26

    Chapter 2 Installation and Setup RIC-155 Installation and Operation Manual 2-4 Connecting the Power Cable[...]

  • Pagina 27

    Controls and Indica tors 3-1 Chapter 3 Operation This chapter provides the following information for the RIC-155 converter: • RIC-155 indicators • Turning-on and turning-off the RIC-155 • Default settings. Installation procedures given in Chapte r 2 must be completed an d checked before attempting to operate RIC-155. 3.1 Turning On RIC-155 ?[...]

  • Pagina 28

    Chapter 3 Operation RIC-155 Installation and Operation Manual 3-2 Controls and Indicators Table 3-1. RIC-155 L EDs Name Function Location PWR (green) ON – Power supply is ON Front panel ALM (red) ON – Ala rm is present in the alarm buffer Front panel SPEED (green) ON – LAN is operating at 100 M bps OFF – LAN is operating at 10 Mbps Front/re[...]

  • Pagina 29

    RIC-155 Installation and Operation Manual Chapter 3 Operation Default Settings 3-3 3.3 Default Settings RIC-155 is managed by an ASCII term inal or PC running a terminal emulatio n program via menu-driven embe dded software. Table 3-3 lists the default settings of the RIC-155 configuration parameters. Table 3-3. RIC-155 Default Setting s Parameter [...]

  • Pagina 30

    Chapter 3 Operation RIC-155 Installation and Operation Manual 3-4 Configuration Alternatives Parameter Default Value Flow control Enable Ethernet mode Full duplex LAN speed 100 Mbps Uplink Frame type SONET BER threshold Disable EED threshold 10E -3 SD threshold 10 E -6 J1 Tx path trace enable Disable J1 path trace Physical Failure Forwarding Disabl[...]

  • Pagina 31

    RIC-155 Installation and Operation Manual Chapter 3 Operation Configuration Alternatives 3-5 session for the first time or after changi ng a terminal data rate, RIC-155 must detect the data rate at boot-up and save it in the database. Onc e the terminal data rate is saved, it is detected automatically during each consecutive terminal session. Prepa[...]

  • Pagina 32

    Chapter 3 Operation RIC-155 Installation and Operation Manual 3-6 Configuration Alternatives • Make sure the Ethernet management ports of the local and remote devices are connected to different LANs. • Do not run diagnostic loopbacks on RIC-15 5 or insert loopback plugs into its Ethernet ports. • When RIC-155 is managed over Telnet or Configu[...]

  • Pagina 33

    RIC-155 Installation and Operation Manual Chapter 3 Operation Navigating the Management Menus 3-7 3.5 Navigating the Management Menus This section provides a ge neral description of the software men u operation and conventions for navigating the menus. Menu Map Figure 3-2 lists all RIC-155 menus. Figure 3-2. Menu Map ConfiguRAD menus differ in appe[...]

  • Pagina 34

    Chapter 3 Operation RIC-155 Installation and Operation Manual 3-8 Navigating the Management Menus RIC-155 Main Menu 1. Inventory 2. Configuration 3. Monitoring 4. File Utilities ESC-prev.menu; !-main menu; &-exit Figure 3-3. Main Menu (Terminal Session) ConfiguRAD provides auxiliary management tools in the lower left-hand corner: • Status –[...]

  • Pagina 35

    RIC-155 Installation and Operation Manual Chapter 3 Operation Turning Off RIC-155 3-9 Navigating Tables Some of the RIC-155 management so ftwa re screens are tables, which are bigger than regular menus and require scrolling to navigate between parameters. For example, the Inventory screen or Manage r List menu are considered tables. Use the followi[...]

  • Pagina 36

    Chapter 3 Operation RIC-155 Installation and Operation Manual 3-10 Turning Off RIC-155[...]

  • Pagina 37

    Configuring RIC-155 for Management 4-1 Chapter 4 Configuration 4.1 Configuring RIC-155 for Management Configuration of R IC-155 is performe d via menu- driven embedded so ftware, us ing a standard ASCII terminal or PC runn ing a terminal emulation applicatio n, connected to the rear panel CONTROL port. Alternatively, you c an manage RIC-155 over Te[...]

  • Pagina 38

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-2 Configuring RIC-155 for Management RIC-155 Management 1. Device Info > 2. Host IP > 3. Manager List > 4. Management Access > > Please select item <1 to 4> ESC-prev.menu; !-main menu; &-exit Figure 4-2. Managemen t Menu Entering Device Information The Dev[...]

  • Pagina 39

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring RIC-155 for Management 4-3 Configuring the Host Parameters RIC-155 can be managed by a networ k management station , which is located on the LAN connected to the unit’s MNG port. In order to establish a proper connection, it is necessary to configure the following : hos[...]

  • Pagina 40

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-4 Configuring RIC-155 for Management RIC-155 Host IP 1. Host IP List > 2. Host default gateway (0.0.0.0) 3. Read community (public) 4. Write community (public) 5. Trap community (public) 6. Host Tagging (Tagged) 7. VLAN ID [1-4094] (1) 8. Host VLAN priority (1) > ESC-prev.me[...]

  • Pagina 41

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring RIC-155 for Management 4-5 RIC-155 Manager List Manager ID IP address Trap Mask 1. 0.0.0.0 NO 2. 0.0.0.0 NO 3. 0.0.0.0 NO 4. 0.0.0.0 NO 5. 0.0.0.0 YES ESC-prev.menu; !-main menu; &-exit; ?-help Figure 4-6. Manager List Menu Controlling the Management Access You can en[...]

  • Pagina 42

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-6 Configuring the RIC-155 for Operation RIC-155 TELNET Access (Enable) 1. Enable 2. Disable 3. Managers only Please select item <1 to 3> ESC-prev.menu; !-main menu; &-exit Figure 4-7. TELNET Access Menu  To enable or disable management ports: 1. From the Management Ac[...]

  • Pagina 43

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring the RIC-155 for Operation 4-7  To display the System Configuration menu: • From the Configuration menu, select System Configuration . The System Configuration menu appears (s ee Figure 4-9 ). Procedures for alarm configuration and masking are detailed in Chapter 5 . [...]

  • Pagina 44

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-8 Configuring the RIC-155 for Operation Changing the Control Port Data Rate  To configure the control port data rate: 1. From the Control Port menu, select Baud Rate . The Baud Rate menu appears (see Figure 4-11 ). 2. Select the term inal rate by typing the number corresponding[...]

  • Pagina 45

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring the Physical Ports 4-9 4.3 Configuring the Physical Ports Physical ports of RIC-15 5 include th e following configurable subsystems: • Data 10/100BaseT port • Management 10/100BaseT port • STM-1/OC-3c port. Configuring the Ethernet Interf ace  To configure the Et[...]

  • Pagina 46

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-10 Configuring the Physical Ports  Uplink Mode, uplink operation mode  SDH  SONET  BER Threshold, controls activation of the Line BER SD and EED  Enable, the EED and SD statistics data is collected  Disable, the EED and SD statistics data is not collected  EED[...]

  • Pagina 47

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring the Physical Ports 4-11 The following alarms tri gger an uplink fa ilure: • Uplink Port Signal Loss • Line Excessive Error Defect • Line Signal Degrad ed Error • Uplink Port Loss of Signal • Uplink Port Loss of Frame • Path Rx Facility Pointer Loss • Path Ex[...]

  • Pagina 48

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-12 Configuring the Internal Bridge 4.4 Configuring the Internal Bridge Configuring Fast Ethernet Bridge RIC-155 includes a high-performance Fast Ethernet QoS bridge with VLAN tagging capabilities, MDI/MDIX auto matic crossover and FDX flow control. Each port works at 10 Mbps or 10[...]

  • Pagina 49

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Configuring the Internal Bridge 4-13 RIC-155 Bridge Configuration Aging Time (sec) (314) Bridging Mode (Filter) Statistics Counted (OK only) Multicast and Broadcast Rate Limit > (8 Mbps) Bridge Ports > Please select item <1 to 5> ESC-prev.menu; !-main menu; &-exit Fig[...]

  • Pagina 50

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-14 Configuring the Internal Bridge  Tag Stripping (specifies whether the port strips the VLAN tags at egress or not)  Enable (the tags are stripped)  Disable (the frames are left unchanged). Whenever the Physical Ports Access mode is cha nged, Tag Stripping is set to its [...]

  • Pagina 51

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Displaying the RIC-155 Status 4-15 4.5 Displaying the RIC-155 Status The RIC-155 software displays the converter system and physical port informatio n. This section describes only stat us in formation of th e RIC-155 device. For description of RIC-155 alarms, refer to Chapter 5 . The[...]

  • Pagina 52

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-16 Displaying the RIC-155 Status Displaying the Port Status The Physical Port Status menu allows you to display status of the Ethernet and STM-1/OC-3c ports of RIC-155. Displaying the Ethernet Port Status Currently RIC-155 includes one user E the rnet port and one management Et he[...]

  • Pagina 53

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Displaying the RIC-155 Status 4-17 Table 4-1. DATA/MNG Port Status Parameters Parameters Values Link Status • Link Up – DATA/MNG link is up • Link Down – DATA/MNG link is down Autonegotiation • Disabled – Autonegotiation is disabled • Not Finished – Autonegotiation is[...]

  • Pagina 54

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-18 Additional Tasks Table 4-2. STM- 1/OC-3c Port Status P arameters Parameters Description Values Uplink Connector Type Type of the STM-1/OC-3c interface connector • Two BNC – BNC coaxial connector • SC – Fiber optic SC connector • ST – Fiber optic ST connector • FC [...]

  • Pagina 55

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Additional Tasks 4-19  User Info to display the li st of current user s, their access rights (read/write) and status (dynamic/permanent).  Reset users password to default this selection is only available to a super user who has logged on with the super user name and password. T[...]

  • Pagina 56

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-20 Additional Tasks RIC-155 Inventory Index Description Class 1 1001 RAD-RIC-155 converter Chassis 2 4001 Power supply Power Supply 3 7001 Fast Eth DATA Port Port 4 7003 Fast Eth MNG Port Port 5 7004 RS-232-Control Port Port 6 7005 Alarm Port Port 7 7006 STM1/OC3 port Port ->&g[...]

  • Pagina 57

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Additional Tasks 4-21 4. From the TFTP Command menu, (see Figure 4-23 ) select Download User File to start downloading file to RIC- 155. RIC-155 automatically erases the back up partition and downloads the new software into the backup partit ion. Once the download is complete, RIC-15[...]

  • Pagina 58

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-22 Additional Tasks Transferring Configuration Files Configuration files can be trans ferred be tween the RIC-155 and the host via TFTP.  To upload a configuration file 1. Follow the path: Main menu > File U tilities menu > SW & File Transfer > Via TFTP . The Via T[...]

  • Pagina 59

    RIC-155 Installation and Operation Manual Chapter 4 Configuration Additional Tasks 4-23 The Software Version screen appears (see Figure 4-24) . RIC-155 SW files Software active version: 1.00 Software active partition: 0 Code size: 190 Date: 28-02-03 Software backup version: 0.00n00 Software backup partition: 1 Code size: 0 Date: 0-0-0 Boot version:[...]

  • Pagina 60

    Chapter 4 Configurati on RIC-155 Installation and Operation Manual 4-24 Additional Tasks Resetting RIC-155 to Factory Defaults You can reset RIC-15 5 to its default sett in gs. Reseting to the defaults does not affect the master clock setting. In addi tion, you can reset local RIC-155 without affecting its management para meters (IP address, mask a[...]

  • Pagina 61

    Monitoring Performance 5-1 Chapter 5 Troubleshooting and Diagnostics This chapter describes the RIC- 155 di agnostic functions, which include: • Statistics collection • Status indications • Alarms. 5.1 Monitoring Performance RIC-155 has capabilities for collection of the Ethernet and S DH/SONET statistics. Displaying the Ethernet Statistics P[...]

  • Pagina 62

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-2 Monitoring Performance RIC-155 Physical Port Statistics Primary Ethernet Statistics > Uplink Statistics > Clear All Statistics > > Please select item <1 to 3> ESC-prev.menu; !-main menu; &-exit; Figure 5-1. P hysical Port Statistics Menu RI[...]

  • Pagina 63

    RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Monitoring Performance 5-3 RIC-155 Uplink Statistics Time Elapsed ...(6) Far End Line ESs ... (7) LOS ... (0) Far End Line SES ... (5) Section CV ... (6) Far End Line UASs ... (6) Section ESs ... (6) Path CV ... (2) Section SESs ... (6) Path ESs ... (6) Section SEFS[...]

  • Pagina 64

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-4 Monitoring Performance Display Description Range [15 min] Section ESs Number of Section Errored Second s in the current interval. Section errored second is a second that contains one or more B1 BIP-8 errors. This co unter is also incremented by one for each sect[...]

  • Pagina 65

    RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Monitoring Performance 5-5 Display Description Range [15 min] Path ESs Number of Path Erro red Seconds in the current interval. Incremented by one for each second containing one or more B3 BIP-8 errors or an SES_P is detected in the current interval. SE S_P are not [...]

  • Pagina 66

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-6 Monitoring Performance  To display SDH/SONET statistics for all int ervals: 1. From the Uplink Statistics menu ( Fi gure 5-3 ), select Intervals Statistics to display the SDH/SONET for all 15-minute intervals. The first page of the Uplink Interval Statistics [...]

  • Pagina 67

    RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Handling Alarms 5-7 RIC-155 Uplink Interval Statistics RCV XMT RCV_ABORT XMT ABORT RCV_FCS 1 100 50 0 1 6 2 100 50 0 1 6 | 3 100 50 0 1 6 V 4 100 50 0 1 6 5 100 50 0 1 6 6 100 50 0 1 6 7 100 50 0 10 6 8 100 50 0 10 6 9 100 50 0 10 6 ->> ESC-prev.menu; !-main m[...]

  • Pagina 68

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-8 Handling Alarms An alarm or warning enters simultaneously both the alarms display and the log file, and the ALM LED turns on to indicate the condit ion. When the fault condition that caused the alarm is cleared, the alarm is removed fr om the alarm screen, but i[...]

  • Pagina 69

    RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Handling Alarms 5-9 The Event Log screen appears ( Figure 5-11 ). RIC-155 Event Log Source Alarm Status Severity Time Date 4 Event Loss Of Signal ON Major 2:11:13 12/06/03 5 Loss Of Frame ON Major 3:52:31 13/06/03 | 3 Line Signal Degraded Error OFF Minor 13:45:27 13[...]

  • Pagina 70

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-10 Handling Alarms You can always reset all alar m severity values to thei r default settings by selecting Default Alarms Settings from the Alarm Co nfiguration menu. RIC-155 System alarms Alarm Name Default Severity Severity Mask 1. Self-test failure Major Major [...]

  • Pagina 71

    RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Handling Alarms 5-11 Terminal Message Description Severity Path Remote Defect Indication Path Remote Defect Indication signal is detected Minor Path Excessive Error Defect Number of the Path Excessive Error Defect errors exceed s threshold Major Path Signal Degraded[...]

  • Pagina 72

    Chapter 5 Troubleshooting and Diagnostics RIC-155 Installation and Operation Manual 5-12 Handling Alarms[...]

  • Pagina 73

    Alarm Relay Connector A-1 Appendix A Connector Wiring A.1 Ethernet Connectors RIC-155 includes two Ethernet po rts designated ET H and MNG-ETH. Table A-1 lists the pinout of the Ethernet connectors. Table A-1. ETH and MNG-ETH Connector Pinout Pin Designation Function Direction 1 RX+ Receive – positive lead Input 2 RX– Receive – negative lead [...]

  • Pagina 74

    Appendix A Connector Wiring RIC-155 Installation and Operation Manual A-2 Control Connector Table A-2. ALARM Co nnector Pinout Pin Alarm Relay Function 1 Minor Minor NO (minor alarm is OFF) 2 Minor Minor NC (minor alarm is ON) 6 Minor Minor COM 4 Major Major NO (major alarm is OFF) 5 Major Major NC (major alarm is ON) 9 Major Major COM 7 Input alar[...]

  • Pagina 75

    Port-Based Traffic Separation B-1 Appendix B Traffic Separation RIC-155 supports separation between Et hernet management and user tra ffic. There are two traffic separation modes: port-based and port-based/VL AN-based. The traffic separation mo de depends on the forwarding mo de of the internal bridge: • Filter – frames are received with VLAN t[...]

  • Pagina 76

    Appendix B Traffic Separation RIC-155 Installation and Operation Manual B-2 Port-Based/VLAN-Based Traffic Separation MNG Hos t Uplink Data Figure B-2. Physical Port Access –MNG Only All When the physical port access is set to All , the internal bridge connections allow both local and remote RIC-155s to be managed via the MNG and DATA ports. MNG H[...]

  • Pagina 77

    RIC-155 Installation and Operation Manual Appendix B Traffic Separation Port-Based/VLAN-Based Traffic Separation B-3 Tagging Modes of the Bridge Ports Each frame is routed according to its V ID. If the frame is unt agged, it receives tag at egress from the uplink port. Uplink and Host Ports The uplink port operates in the following tagging modes: ?[...]

  • Pagina 78

    Appendix B Traffic Separation RIC-155 Installation and Operation Manual B-4 Port-Based/VLAN-Based Traffic Separation Internal Operation Mode s of the Bridge Ports All VLAN information is k ept in the VTU (VLAN Translation Unit) table. The bridge ports operate in the following internal modes: • Secure – only frames with VIDs that are registered [...]

  • Pagina 79

    RIC-155 Installation and Operation Manual Appendix B Traffic Separation Port-Based/VLAN-Based Traffic Separation B-5 MNG Hos t Uplink Data Secure Se cure Fallback T ag S tripping Enabled Fallback St a c k Figure B-5. Port Access Mode – None MNG Only In the MNG Only port ac cess mode, local data fra mes can reach the uplink port only. Local manage[...]

  • Pagina 80

    Appendix B Traffic Separation RIC-155 Installation and Operation Manual B-6 Configuring for a Typical Application Local MNG Only In the Local MNG Only port access mode, local data frames can reach the uplink port only. Local management frames can reach the host an d uplink ports, and the remote management frames can reach the local uplink, ho st an[...]

  • Pagina 81

    RIC-155 Installation and Operation Manual Appendix B Traffic Separation Configuring for a Typical Application B-7 The units are configured a s follows: • Local RIC-155:  Forwarding – Filter Tagged  Port Management Access – MNG Only  Host Tagging – Untagged  Management and data ports – Tag stripping is enabled  uplink port ?[...]

  • Pagina 82

    Appendix B Traffic Separation RIC-155 Installation and Operation Manual B-8 Configuring for a Typical Application MNG 1 1 2 2 1 1 1 1 Lo ca l RI C-155 Swi tc h Remote RIC- 155 2 22 2 Host Host Uplink Upl ink Data Ma nage ment Station LAN LAN Data Figure B-10. Managing RIC-155 via Da ta Port The units are configured a s follows: • Local RIC-155: ?[...]

  • Pagina 83

    I-1 Index —1— 10/100BaseT. See Fast Ethernet —A— AC power connecting, 2-3 Aging Time, 4-12 Alarm relay, 1-3, 1-7 Alarms displaying, 5-7 masking, 5-10 severity, 5-9 Autonegotiation, 4-9 —B— Back panel, 1-4 Baud Rate, 4-7 BER threshold, 4-10 Bridge Configuration, 4-12 Bridge ports configuring, 4-13 —C— Clock modes, 4-7 ConfiguRAD, 1-3[...]

  • Pagina 84

    Index RIC-155 Installation and Operation Manual I-2 Fast Ethernet, 1-2 STM-1/OC-3c, 1-2 Internal bridge, 1-3 Inventory, 4-19 IP parameters, 4-3 —J— J1 path trace, 4-10 —L— LAN speed, 4-9 LED indicators, 3-1 LED Indicators, 1-7 Log file, 5-8 —M— Management ASCII terminal, 3-5 Ethernet port, 3-5 Management access, 4-5 Manager list, 4-4 Ma[...]

  • Pagina 85

    24 Raoul W allenberg St., T el Aviv 69719, Isr ael T el: +972-3-6458181, F ax: +972-3-6483331, +972-3- 6498250 E-mail: , W eb site: Customer Response Form RAD Data Communications would like your hel p in improving its product documentation. Please complete and return this form by mail or by fax or s end us an e-mail with your comments. Thank you fo[...]

  • Pagina 86

    [...]

  • Pagina 87

    Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory information (S afety, Compliance, Warnings, etc.) ❒ Difficulty in finding needed informatio n ❒ Missing information ❒ Illogical flow of information ❒ Style (spelling, grammar, references, etc.) ❒ Appearance ❒[...]

  • Pagina 88

    [...]

  • Pagina 89

    [...]

  • Pagina 90

    Publication No. 187-20 0-01/06 www.rad.com INTERNATIONAL HEADQUAR TERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972-3-6498250, 972-3-647 4436, Email: market@rad.com NORTH AMERICA HEADQUARTE RS: 900 Corporate Drive, Mahwah, N.J. 07430, Tel: (2 01) 529-1100 Toll Free: 1-800-444-7234, Fa x: (201) 529-5777, Email: ma[...]