Vai alla pagina of
Manuali d’uso simili
-
Swimming Pool Heater
Raypak 2002B
7 pagine 2.53 mb -
Swimming Pool Heater
Raypak 267
4 pagine 0.19 mb -
Swimming Pool Heater
Raypak Hi-Delta Commercial Swimming Pool Heater
1 pagine 0.01 mb -
Swimming Pool Heater
Raypak C-R185A
46 pagine 1.72 mb -
Swimming Pool Heater
Raypak 30A
4 pagine 0.31 mb -
Swimming Pool Heater
Raypak 405B
4 pagine 0.53 mb -
Swimming Pool Heater
Raypak HI DELTA 122-322
44 pagine 1.2 mb -
Swimming Pool Heater
Raypak 105A
4 pagine 0.84 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Raypak D-2 POWER VENT 206A. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Raypak D-2 POWER VENT 206A o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Raypak D-2 POWER VENT 206A descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Raypak D-2 POWER VENT 206A dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Raypak D-2 POWER VENT 206A
- nome del fabbricante e anno di fabbricazione Raypak D-2 POWER VENT 206A
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Raypak D-2 POWER VENT 206A
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Raypak D-2 POWER VENT 206A non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Raypak D-2 POWER VENT 206A e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Raypak in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Raypak D-2 POWER VENT 206A, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Raypak D-2 POWER VENT 206A, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Raypak D-2 POWER VENT 206A. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
INST ALLA TION & OPERA TING INSTR UCTIONS SWIMMING POOL & SP A HEA TER D-2 Catalog No. 6000.57.1D Effective: 05-21-10 Replaces: 10-26-06 P/N 241243 Rev . 3 W ARNING: If these instructions are not followed exactly , a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammab[...]
-
Pagina 2
2 Rev . 3 reflects the following: Changes to: Parts photos on page 3, dimensional illustration on page 4, Fig. 1 and Fig. 3 on page 5, Illustrated Parts List on page 19[...]
-
Pagina 3
3 RECEIVING EQUIPMENT On receipt of your equipment, it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton. If it is damaged, report the damage to the carrier immediate- l y[...]
-
Pagina 4
4 INST ALLA TION REQUIREMENTS Failure to install, maintain and/or operate the Power V ent in accordance with manufacturer ʼ s instructions may result in conditions which can produce bodily injury and property damage. The equipment must be installed by a qualified installer in accordance with all local codes, or , in the absence of local codes, wit[...]
-
Pagina 5
5 INST ALLA TION 1 . Start off by disconnecting main power to the heater . 2. Remove the front door from the heater . See Fig 1. 3. If this is a retro-fit application, remove existing “Pagoda T op” and discard. See Fig. 2. If equipped with a drafthood, refer to drafthood installation manual for removal process. 4 . Remove the (6) Phillips screw[...]
-
Pagina 6
6 INST ALLA TION (Continued) 6 . Lower the jacket top back onto the heater and reinstall the (6) Phillips screws. See Fig. 3. 7. If installing on a model 266, 267, 406 or 407 heater , skip step 8. 8. T urn t he Po wer V ent u psi de do wn . Usi ng a 5/ 16” n ut dr iv er , re loc ate t he mo un tin g bra cke ts as s ho wn in F ig. 8 . 9. Place the[...]
-
Pagina 7
7 INST ALLA TION (Continued) 1 3. Install the right side outdoor conduit through the top 7/8” hole located on the right side of the heater . See. Fig. 13. Note: Y ou must first remove the 7/8” plug on the heater to install the hard conduit. 14. Wire the heater power lines along with the D-2 Power V ent power lines to the supply power per the wi[...]
-
Pagina 8
8 INST ALLA TION (Continued) 1 9. Route the 24 V AC harness through the 7/8” grommet, See Fig. 17. 20. Continue to route the harness down through any available grommet hole. See Fig. 18. 21. Wire the harness along with the installed gas valve harness per the wiring diagram. 22. Reinstall the (4) Phillips screws that hold the control panel to the [...]
-
Pagina 9
9 U.S. Ins tallations 1 Canad ian Inst alla tions 2 A Clear ance above gr ade , veranda, p orch , deck, or balco ny 1 ft (30 c m) 1 ft (30 c m) B Clear ance to window or do or that may b e o pened 4 ft (1.2 m) below or to side of opening; 1 foo t (30 c m) a bove op ening 3 ft (91 cm) C Clearance to perma nen tly closed window ** D V ertical clearan[...]
-
Pagina 10
10 VENTING (Continued)[...]
-
Pagina 11
11 VENTING (Continued)[...]
-
Pagina 12
12 VENTING (Continued)[...]
-
Pagina 13
13 VENTING (Continued)[...]
-
Pagina 14
14 SEQUENCE OF OPERA TION On call for heat, the PC board will go through its safety chain (water pressure switch, high limit 1 & 2, roll-out, etc.). When the safety chain is closed, the IID pilot will begin to spark and the pilot gas valve will open. A flame will be lit at the pilot assembly . When an acceptable signal is sent back to the PC bo[...]
-
Pagina 15
15 WIRING (Continued) STEP 1 : VERIFY CURRENT CONNECTIONS AS SHOWN BELOW . P/PV C/ M/MV MV PV R/BK Y/BK Y/BK V/BK V/BK V/BK Y/BK G/BK P4 1 RELA Y D-2 POWER VENT Y/BK HONEYWELL V AL VE Y/BK V/W V/BK HONEYWELL V AL VE PV MV M /MV C/ P/PV STEP 2 : DISCONNECT BOTH TERMINALS MVPV & MV AS SHOWN BELOW . D-2 POWER VENT V/BK V/W Y/BK Y/BK R/BK Y/BK V/BK[...]
-
Pagina 16
16 WIRING (Continued) MODELS 206, 266, 336, 406 EQUIPPED WITH HONEYWELL GAS V A LV E V/W V/BK V/BK G/BK R/BK 1 P4 D -2 POWER VENT P/PV C/ M/MV MV PV HONEYWELL V AL VE STEP 4 : CONNECT THE MAIN V AL VE LINE, FEMALE SP ADE TO MALE SP ADE AS SHOWN BELOW . D-2 POWER VENT V/BK Y/BK V/W V/BK R/BK P4 1 G/BK STEP 3 : CONNECT THE RETURN LINE, FEMALE SP ADE [...]
-
Pagina 17
17 WIRING DIAGRAM – MODELS 207A, 267A, 337A, 407A POWER VENT D-2 D-2 BLOWER POWER VENT GAS V AL VE HONEYWELL 1 1 + -[...]
-
Pagina 18
18 WIRING DIAGRAM – MODELS 206A, 266A, 336A, 406A POWER VENT D-2 D-2 BLOWER POWER VENT + - 1 1 TH TR[...]
-
Pagina 19
19 REPLACEMENT P ARTS NOTE: T o supply you with the correct part, it is impor- tant that you supply the heater model number , serial number and type of gas when applicable. Any part returned for replacement under standard c ompany warranties must be properly tagged with a return parts tag, completely filled in with the heater serial number , model [...]
-
Pagina 20
20 w w w .r ay pak .co m Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A.[...]