1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso RuggedCom RUGGEDSWITCH RSG2288. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica RuggedCom RUGGEDSWITCH RSG2288 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso RuggedCom RUGGEDSWITCH RSG2288 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso RuggedCom RUGGEDSWITCH RSG2288 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo RuggedCom RUGGEDSWITCH RSG2288
- nome del fabbricante e anno di fabbricazione RuggedCom RUGGEDSWITCH RSG2288
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature RuggedCom RUGGEDSWITCH RSG2288
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio RuggedCom RUGGEDSWITCH RSG2288 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti RuggedCom RUGGEDSWITCH RSG2288 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio RuggedCom in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche RuggedCom RUGGEDSWITCH RSG2288, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo RuggedCom RUGGEDSWITCH RSG2288, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso RuggedCom RUGGEDSWITCH RSG2288. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    RuggedSwitch ® RSG2288 9-Port Modular Managed Gigabit Ethernet Switch Installation Guide June 2, 2011 www.ruggedcom.com RuggedCom Inc. I 300 Applewood Crescent, Concor d, Ontario, Canada L4K 5C7 Tel: +1 905 856 5288 I Fax: +1 905 856 1995 I Toll Free: 1 888 264 0006[...]

  • Pagina 2

    Cop yright COPYRIGHT © 2010 RuggedCom Inc. ALL RIGHTS RESERVED Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expr essly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. T[...]

  • Pagina 3

    Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These lim its are designed to provide reasonable protection against harmful interferen ce when the equipment is operated in a commercial enviro[...]

  • Pagina 4

    Table of Contents T able of Content s Table of Contents .............................................................................................................. 4 Table of Figures ............................................................................................................... .6 Table of Tables .................................[...]

  • Pagina 5

    Table of Contents 4.3 IEC Environmental Type Tests ........................................................................ 42 5 Agency Approvals ................................................................................................... 43 6 Warranty ..........................................................................................[...]

  • Pagina 6

    Table of Figures T able of Figures Figure 1: RSG2288 Rack mount chassis orientation options – Front and rear mount. ... 11 Figure 2: RSG2288 Ethernet Port Layout ....................................................................... 12 Figure 3: Ethernet panel LEDs .................................................................................[...]

  • Pagina 7

    Table of Tables 7 RuggedCom ® RuggedSwitch ® RSG2288 Installation Guide rev106 T able of T ables Table 1: Pluggable Fiber Transceiver Modules ............................................................... 13 Table 2: Fixed Fiber Transceivers ................................................................................... 14 Table 3: LED Displ[...]

  • Pagina 8

    Product Overview 1 Product Overview 1.1 Functional Overview The RuggedSwitch ® RSG2288 is an industrially hardened, fully managed, modular, Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility s ubstation and industrial environments. The RSG2288 includes the IEEE 1588 v2 protocol with h[...]

  • Pagina 9

    Product Overview Cy ber Security Features  Multi-level user passwords  SSH/SSL encryption  MAC-based port security  Selective port enable/disable  Port-based network access control using IEEE 802.1x  VLAN support (IEEE 802.1Q) to segregate and secure network traffic  RADIUS centralized access management  SNMPv3 featuring enc[...]

  • Pagina 10

    Product Overview  Port configuration, status, statistics, mirroring, security  Loss of link management on fiber ports  SNTP time synchronization (both client and server)  Industrial automation features (e.g. Modbus) Rugged Operating System (ROS™) Management Features  Secure Web-based management interface  Console menu and Comman[...]

  • Pagina 11

    Product Overview 1.3 Mounting Flexibility The RS2000 series of products have been designed with maximum mounting and display flexibility. Customers can order an RS2000 series switch th at can be mounted in a standard 19” rack, 1” DIN Rail, or directly onto a panel. For rack mount installations, the RS2000 series can be ordered with connectors o[...]

  • Pagina 12

    Product Overview 1.4 Ethernet Panel Description The Ethernet connector panel of the RSG2288 is organized into six slots, five of which are modular and may be selected at the time the unit is ordered. Figure 2 shows the p hysical layout of these ports. Figure 2: RSG2288 Ethernet Port Lay out Slots 1, 2, 3 and 4 support two-port Ethernet modules up t[...]

  • Pagina 13

    Product Overview 1.4.1 Fiber Optic Transceiver Orientation and Connection Depending on the order code of the product, the RSG2200 series products can be equipped with several different t ypes of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be properly connected and matched for proper link and operation. Module[...]

  • Pagina 14

    Product Overview Figure 6 through Figure 9 show front and top views of the fixed fiber transceiver modules supported by RuggedSwitch ® . Note that when the daughter card containing transceiver modules is installed in the unit, most of the body of the module as shown in top views below will not be visible. Table 2: Fixed Fiber Transceivers Figure 6[...]

  • Pagina 15

    Product Overview 1.5 Display Panel Description RuggedCom RS2000 series products are equipped with a versatile d isplay panel, shown in Figure 10 , which is designed to provide quick status information for each port, as well as the entire device to allow for simple diagnostics and troubleshooting. It features:  RS232 console port for ‘out of ba[...]

  • Pagina 16

    Product Overview The port-ba sed LEDs can be cycled between three display modes: Status, Duplex, and Speed. Pushing the mode button causes the display mode to be cycled. Mode Color Description Green (Solid) Link detected Green (Blinking) Activity Status Off No link Green (Solid) Full-Duplex operation Orange (Solid) Half-Duplex operation Duplex Off [...]

  • Pagina 17

    Installation 2 Inst allation 2.1 Rack Mounting The RS2000 family of products can be ra ck mounted using the included rack mount adapter assemblies shown in Figure 11 . Secure the rack mount adapter to the front sid e of the chassis using the included black PAN head Philips screws in the positions shown in Figure 13 . The entire chassis can then be [...]

  • Pagina 18

    Installation 2.2 Panel and DIN Rail Mounting RS2000 series products can be ordered as a Panel/DIN mount chassis. Both options involve the use of the panel/DIN adapters to be mounted on each side of the chassis enclosure. The adapter allows for the chassis to be mounted on the standard 1” DIN rail using the grooves in the adapter, secured using th[...]

  • Pagina 19

    Installation 2.3 Power Supply Wiring and Grounding RS2000 series products support dual redundant power supplies – “Power Supply 1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 and the fail- safe relay are located on the terminal block as shown in Figure 14 and Figure 15 . RSG2200 series produ cts can be equipped with eit[...]

  • Pagina 20

    Installation The RS200 0 Family chassis ground connection, shown in Figure 16 , uses a #6- 32 screw. It is recommended to terminate the ground connection in a #6 ring lug, and to use a torque setting not exceeding 15 in.lbs (1.7 Nm). Figure 16: Chassis Ground Connecti on #6 rin g lu g stainless steel standoff #6-32 screw with ext. wash er. Terminal[...]

  • Pagina 21

    Installation 2.3.1 AC Power Supply Wiring Examples (RSG2288) Figure 17: AC Single Power Supply Wiring Example Figure 18: AC Dual Redundant Po wer Supply Wiring Example Notes:  100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed.  Equipment must be installed according to the applicable country wiring code[...]

  • Pagina 22

    Installation 2.3.2 DC Power Supply Wiring Examples Figure 19: DC Power Supply Wiring Examples Notes:  125/250VDC rated equipment: A 300VDC appropriately rated circuit breaker must be installed.  A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.  For dual DC power supplies, Separate circuit breakers must be instal[...]

  • Pagina 23

    Installation 2.3.3 Dual Power Supplies – DC and AC Inputs Figure 20: DC and AC Power Supply Wiring Examples Notes:  125/250VDC rated equipment: A 300VDC appropriately rated circuit breaker must be installed.  100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed.  A circuit breaker is not required for[...]

  • Pagina 24

    Installation 2.4 Dielectric Strength (HIPOT) Testing For dielectric strength (HIPOT) testing in the field, users must remove the metal jumper located on terminal 2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppr[...]

  • Pagina 25

    Installation 2.5 Failsafe Alarm Relay Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on RS2000 series products. The contact s are energized upon power-up of the unit and remain energized unless a critical error occurs. The proper relay connections are shown in Figure 22 . Con[...]

  • Pagina 26

    Installation 2.6 Console Port Wiring A RS232 console port for configuration and management of the device is located on the LED display module shown in Figure 23 . This port is intended to be a temporary c onnection during initial configuration or troubleshooting and a llows for direct serial access to the management console. The connection is made [...]

  • Pagina 27

    Installation 2.7 Ethernet Ports 2.7.1 RJ45 Twisted-Pair Data Ports RSG2288 Ethernet switches are equipped with up to nine 10/100/1000BaseTX ports that allow connection to st andard CAT-5 UTP cable with RJ45 male connectors. All RS2000 series RJ45 RuggedSwitch products feature auto- negotiation, auto-polarity, and auto-crossover functions. T he RJ45[...]

  • Pagina 28

    Installation Cabling Category 1000BaseTx Compliant Required action < 5 No New wire infrastructure required 5 Yes Verify TIA/EIA-568-A compliance 5e Yes No action required. New installations should b e designed with Category 5e components or higher 6 Yes No action required > 6 Yes Connector and cabling standards to be determined. Table 8: Cabl[...]

  • Pagina 29

    Installation prevent the accumulation of residue or particles that may inhibit proper operation.  Ensuring that the user has properly discharged any possible electrostatic build-up in order to prevent electrostatic discharges (ESD). This can be accomplished by proper user ‘grounding’ via an ESD wrist strap, or by touching earth or chassis gr[...]

  • Pagina 30

    Installation 2.8.2 GBIC Module Removal GBIC Modules have two locking latches, one on either side of the module, as shown in Figure 27 . To remove a GBIC modu le, disconnect any cables and replace the dust cover to protect the optics. Depress both latches simultaneously and gently pull the module from the chassis. Th e module should be immediately s[...]

  • Pagina 31

    Installation 2.9 Precision Time Protocol (PTP) Card and IEEE1588 v2 The Precision Time Protocol (PTP) card option for the RSG2288 adds the ability to provide time synchronization via IRIG-B , and to synchronize to an external IRIG-B source or to the GPS network. The time synchronization capabilities of the RSG2288, both with and without the PTP car[...]

  • Pagina 32

    Installation 2.9.1 PTP Card Panel Description Figure 30: PTP Card Panel Description The four BNC connectors on front panel of the PTP card are defined in Table 11 , below: Connector Function AM OUT IRIG-B126/B127 AM signal output, software enabled TTL OUT IRIG-B006/B007 PWM or 1 PPS signal output, software selectable TTL IN TTL-level IRIG-B PWM sig[...]

  • Pagina 33

    Installation  Lightning arrestor (optional)  Line Amplifier or Filter (optional) To ensure correct GPS signal reception, the overall system of antenna, cabling, lightning arrestor, line amplifier and filters requires a relativ e gain which should be greater than 5 dBi but less than 18 dBi (to avoid signal saturation at the receiver input). 2.[...]

  • Pagina 34

    Installation which degrades the accuracy of the calculated t ime and position. The time delay is dependent on the type of dielectric material in t he cable and ranges from 1 to 2 ns/ft. The table below gives some examples of the delay that can be expected based on the dielectric type. Dielectric Type Time Delay (ns/ft) Propagation Velocity (% of c)[...]

  • Pagina 35

    Installation The number of IRIG-B d evices that can be connected to the AM or PWM sources is dependent on the cabling type and length as well as the input impedances of the devices. Figure 31 shows a simplified circuit diagram of the interface between an IRIG-B s ource and connected devices. Vs Rs Rc R L /N Source Cab ling Device Figure 31: IRIG-B [...]

  • Pagina 36

    Technical Specifications 3 T echnical Specifications 3.1 Power Supply Specifications Input Range Power Supply Type Min Max Internal Fuse Rating Max . Po we r Consumption 3 12 – 24 VDC 10 VDC 36 VDC 6.3A(F) 2 48 VDC 36 VDC 59 VDC 3.15A(T) 2 HI (125/250 VDC) 1 HI (110/230 VAC) 1 88 VDC 85 VAC 300 VDC 264 VAC 2A(T) 1,2 28W Notes: 1. The “HI” pow[...]

  • Pagina 37

    Technical Specifications 3.4 Copper Ethernet Port Specifications The RSG2288 can be ordered with two-port 10/100/1000Tx modules in slots 1, 2, 3, and 4, and a one-port 10/100/1000Tx module in 5. All copper ports have the following specifications: Parameter Specification Notes Speed 10/100/1000 Mbps Auto-negotiating Duplex FDX / HDX Auto-negotiating[...]

  • Pagina 38

    Technical Specifications FXA09 SM SC 9/125 1310 0 5 -37 0 90 37 FXA10 SM LC 9/125 1310 0 5 -37 0 90 37 3.5.2 Gigabit Ethernet (1000Mbps) Optical Specifications Fixed Gigabit Transceivers Order Code Mode Connector Type Cable Type (um) Tx λ (typ.) (nm) Tx min (dBm) Tx max (dBm) Rx Sensitivity (dBm) Rx Saturation (dBm) Distance (typ.) (km) Power Budg[...]

  • Pagina 39

    Technical Specifications 3.6 PTP Card Specifications IRIG-B PWM Input Parameter Typical Value Input Voltage TTL-Compa tible Input Impedance > 200 k Ω 3.6.1 IRIG-B Outputs IRIG-B003 PWM Output Parameter Typical Value Output Current (I S ) 100 mA Output Voltage (V S ) 5 V p-p Output Impedance (R S ) 50 Ω Table 15: IRIG-B PWM Output Specificati[...]

  • Pagina 40

    Technical Specifications 3.8 Mechanical Specifications Parameter Value Comments Dimensions 18.29 x 12.14 x 1.75 inches (464,57) x (308,356) x (44, 45) mm (Length x Width x Height) with mounting brackets installed Weight 10 lb (4.5 Kg) Enclosure 18AWG galvanized steel Figure 32: RSG2288 Mechanical Dim ensions 40 RuggedCom ® RuggedSwitch ® RSG2288 [...]

  • Pagina 41

    Type Tests 4 T ype T est s 4.1 IEC 61850-3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact +/- 8kV 4 IEC 61000-4-2 ESD Enclosure Air +/- 15kV 4 IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m x Signal ports +/- 4kV @ 2.5kHz x D.C. Power ports +/- 4kV 4 A.C. Power ports +/- 4kV 4 IEC 61000-4-4 Burst (Fast Transient) Earth[...]

  • Pagina 42

    Type Tests 4.2 IEEE 1613 Type Tests IEEE Test IEEE 1613 Clause Description Test Levels Enclosure Contact +/- 8kV C37.90.3 9 ESD Enc losure Air +/- 15kV C37.90.2 8 Radiated RFI Enclosure ports 35 V/m Signal ports +/- 4kV @ 2.5kHz D.C. Power ports +/- 4kV A.C. Power ports +/- 4kV C37.90.1 7 Fast Transient Earth ground ports +/- 4kV Signal ports 2.5kV[...]

  • Pagina 43

    Agency Approvals 43 RuggedCom ® RuggedSwitch ® RSG2288 Installation Guide rev106 5 Agency Approvals Agency Standards Comments CSA CSA C22.2 No. 60950, UL 60950 Passed CE EN 60950, EN 61000-6-2 CE Compliance is claimed via Declaration of Self Conformity Route FCC FCC Part 15, Class A Passed CISPR EN55022, Class A Passed FDA/CDRH 21 CFR Chapter 1, [...]