Sears 153.336862 40 GALLON PROPANE (L.P.) manuale d’uso
- Visualizza on-line o scarica il manuale
- 32 pagine
- 0.63 mb
Vai alla pagina of
Manuali d’uso simili
-
Water Heater
Sears 153.33685
32 pagine 3.14 mb -
Water Heater
Sears 449.31031
16 pagine 1.69 mb -
Water Heater
Sears 153.33545
32 pagine 2.77 mb -
Water Heater
Sears 153.33262
44 pagine 4.49 mb -
Water Heater
Sears 153.336332
24 pagine 3.91 mb -
Water Heater
Sears KENMORE POWER MISER 153.336331
24 pagine 4.1 mb -
Water Heater
Sears 449.320411
16 pagine 1.69 mb -
Water Heater
Sears 153.326363 30 GAL.
32 pagine 0.64 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Sears 153.336862 40 GALLON PROPANE (L.P.). La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Sears 153.336862 40 GALLON PROPANE (L.P.) o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Sears 153.336862 40 GALLON PROPANE (L.P.) descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Sears 153.336862 40 GALLON PROPANE (L.P.) dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Sears 153.336862 40 GALLON PROPANE (L.P.)
- nome del fabbricante e anno di fabbricazione Sears 153.336862 40 GALLON PROPANE (L.P.)
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Sears 153.336862 40 GALLON PROPANE (L.P.)
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Sears 153.336862 40 GALLON PROPANE (L.P.) non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Sears 153.336862 40 GALLON PROPANE (L.P.) e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Sears in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Sears 153.336862 40 GALLON PROPANE (L.P.), come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Sears 153.336862 40 GALLON PROPANE (L.P.), l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Sears 153.336862 40 GALLON PROPANE (L.P.). Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
1 www.sears.com Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A C3 T echnology ® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. Owner ’ s Manual FOR POT ABLE W A TER HEA TING ONL Y . NOT SUIT ABLE FOR SP ACE HEA TING . NOT[...]
-
Pagina 2
2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely import ant in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety[...]
-
Pagina 3
3 SAFETY PRECAUTIONS[...]
-
Pagina 4
4 T ABLE OF CONTENTS SAFE INST ALLA TION, USE AND SERVICE ............................................................................................. .... 2 SAFETY PRECAUTIONS ............................................................................................................. ................. 3 T ABLE OF CONTENTS .......................[...]
-
Pagina 5
5 Thank Y ou for purchasing a Kenmore water heater . Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ® . They will arrange for prompt, quality installation by Sears authorized contractors. Abbreviation[...]
-
Pagina 6
6 MA TERIALS AND BASIC TOOLS NEEDED Materials Needed T o simplify the installation Sears has available the installation p arts shown below . Y ou may or may not need all of these materials, depending on your type of installation. W A TER HEA TER INST ALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER[...]
-
Pagina 7
7 TYPICAL INST ALLA TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe B Draft Hood C Anode D Hot Water Outlet E Outlet F Flexible Water Connections G Gas Supply H Manual Gas Shut-off V alve I Ground Joint Union * INST ALL IN ACCORDANCE WITH LOCAL CODES. * DRIP LEG AS REQUIRED BY LOCAL CODES. FIGURE 1. J Drip Leg (Sediment T rap) K In[...]
-
Pagina 8
8 INST ALLA TION INSTRUCTIONS 1. Turn “OFF” the gas supply to the water heater . If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3. 2. Turn “OFF” the water supply [...]
-
Pagina 9
9 • Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply . INST ALLA TIONS IN AREAS WHERE FLAMMABLE LIQUIDS (V APORS) ARE LIKEL Y T O BE PRESENT OR ST ORED (GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and othe[...]
-
Pagina 10
10 Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear , 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the lab[...]
-
Pagina 11
11 • Do not apply insulation to the top of the water heater , as this will interfere with safe operation of the draft hood. • Do not cover the outer door , thermostat or temperature & pressure relief valve. • Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner . • D[...]
-
Pagina 12
12 FIGURE 12. • When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (1 1 cm 2 /kW) of total input rating of all equipment in the enclosure, see Figure 13. • When ducts are used, they shall be of the same cross- sectional area as the free area of the o[...]
-
Pagina 13
13 This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance. All piping components connected to this unit for space heating applications shall be suitable for use with potable water . T oxic chemicals, such as those used for boiler treatment shall not be introduced into this sys[...]
-
Pagina 14
14 Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve. Secure all insulation using tape. T emperature-Pressure Relief Valve This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer . The valve is certified by a[...]
-
Pagina 15
15 The temperature-pressure relief valve must be manually operated at least once a year . Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be ex[...]
-
Pagina 16
16 FIGURE 17. The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter), see Figure 18. FIGURE 18. All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provid[...]
-
Pagina 17
17 Sediment T rap s Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. T o trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated[...]
-
Pagina 18
18 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. • If you cannot reach your gas supplier, call the fire department. C . Use only your hand to push in or turn the gas control knob. Never use tools. If the knob[...]
-
Pagina 19
19 THE WA TER HEA TER SHOULD BE LOCA TED IN AN AREA WHERE THE GENERAL PUBLIC DOES NOT HA VE ACCESS. IF A SUIT ABLE AREA IS NOT A V AILABLE, A COVER SHOULD BE INST ALLED OVER THE THERMOST A T TO PREVENT T AMPERING . Suitable covers are available through the Sears Service Center . Never allow small children to use a hot water tap, or to draw their ow[...]
-
Pagina 20
20 T ank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the sediment deposit[...]
-
Pagina 21
21 Housekeeping V acuum around base of water heater for dust, dirt, and lint on a regular basis. AT LEAST ONCE EVER AT LEAST ONCE EVER AT LEAST ONCE EVER AT LEAST ONCE EVER AT LEAST ONCE EVER Y SIX MONTHS Y SIX MONTHS Y SIX MONTHS Y SIX MONTHS Y SIX MONTHS A A A A A VISUAL INSPECTION SHOULD BE MADE OF VISUAL INSPECTION SHOULD BE MADE OF VISUAL INSP[...]
-
Pagina 22
22 5. Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN. 6. Follow instructions in the Filling The Water Heater section. 7. Check for leaks. 8. Follow the lighting instructions in the Lighting section to restart the water heater . FIGURE 25. Service Before calling for repair service, read [...]
-
Pagina 23
23 TROUBLESHOOTING GUIDE Start Up Conditions Thermal Expansion W ater supply system may , because of such events as high line pressure, frequent cut-offs, and the effects of water hammer have installed devices such as pressure reducing valves, check valves, back flow preventers, etc., to control these types of problems. When these devices are not e[...]
-
Pagina 24
24 is not drawn toward the draft hood, shut off water heater and make necessary air supply changes to correct. Condensation Whenever the water heater is filled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when: • A new water[...]
-
Pagina 25
25 Operational Conditions (Continued) Leakage Checkpoints FIGURE 27. Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely filled with water . T o prevent damag[...]
-
Pagina 26
26 These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME ® (1-800-469-4663) for assistance. Inform the associate that this is a “Flammable V apor Ignition Resist ant” Product. Problem Cause Solution Improperly sealed, hot or cold supply connection, Tighten threaded connections. relief valve, drain [...]
-
Pagina 27
27 NOTES:[...]
-
Pagina 28
28 NOTES:[...]
-
Pagina 29
29 Model Numbers Key No. Part Description 153.336162 153.336262 153.336362 1 Air Intake Screen 9003406 9003406 9003406 2 Anode Rod 9003888 9003889 9003889 3 Burner Assembly 9003477 9003485 9003442 4 Burner Head** 9003385 9003385 9003385 5 Burner Orifice** 9003478 (#38) 9003457 (#37) 9003443 (#36) 6 Burner Tube w/Rubber Boot** 9003391 9003391 900339[...]
-
Pagina 30
30 Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME ® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit. WHEN ORDERING REP AIR P A R TS, AL WA YS GIVE THE FOLLOWING INFORMA TION: • MODEL NUMBER ?[...]
-
Pagina 31
31 Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME ® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit. WHEN ORDERING REP AIR P A RTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: • MODEL NUMBER •[...]
-
Pagina 32
32 6 - YEAR LIMITED W ARRANTY ON W A TER HEA TER For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner’s manual instructions and all local applicable plumbing codes, Sears will: 1 . Supply free water heater parts for those that are defective in material or work[...]