Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
SimpleTech ZeusIOPS manuale d’uso - BKManuals

SimpleTech ZeusIOPS manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso SimpleTech ZeusIOPS. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica SimpleTech ZeusIOPS o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso SimpleTech ZeusIOPS descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso SimpleTech ZeusIOPS dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo SimpleTech ZeusIOPS
- nome del fabbricante e anno di fabbricazione SimpleTech ZeusIOPS
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature SimpleTech ZeusIOPS
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio SimpleTech ZeusIOPS non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti SimpleTech ZeusIOPS e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio SimpleTech in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche SimpleTech ZeusIOPS, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo SimpleTech ZeusIOPS, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso SimpleTech ZeusIOPS. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    Zeus IOPS Fibre Channel 3.5-Inch Solid State Drive Product Manual 61000-04522-101: Revision 1.0[...]

  • Pagina 2

    ii Export Administra tion Regula tion This document may conta in technica l data co ntrolled by the U.S. Export Administration Regulations, and may be subject to the appr oval of the U.S. Department of Commerce prior to export. Any export, directly or indirectly, in contravention of the U.S. Expo rt Administration Regu lations is prohibited. The in[...]

  • Pagina 3

    ZEUS IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 iii M ANUAL C ONVENTIONS The following icons are used throughout this document to identify additional information of wh ich the reader should be aware. SHOCK HAZARD: This icon indicates the danger of an electrical shock that may harm or otherwise prove fatal to the user. CAU[...]

  • Pagina 4

    iv ZEUS IOPS 3.5-Inch Fibre Channel So lid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 5

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 v R EVISION H ISTORY Revision Status Summary Sheet Revision Date Sheet(s) Affected 0.1 11/30/2006 All. Initial release. 1.0 02/16/2007 Official release.[...]

  • Pagina 6

    vi Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 7

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 vii T ABLE OF C ONTENTS Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii i Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v List of Tables . . [...]

  • Pagina 8

    viii Zeus IOPS 3.5-Inch Fibre Channel Solid State Dr ive Product Manual Rev. 1.0 Reliability .................................................................................................................... ..... 21 Environmental Characteristics ......................................................................................... 22 Power...[...]

  • Pagina 9

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 ix Ready LED Out Signal ..................................................................................................... ...... .. 29 -Parallel ESI and SEL_n/P_ESI_n ........................................................................................... 29 SEL_ID Fu[...]

  • Pagina 10

    x Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 Verify (10) (2Fh) ...................................................................................................... 48 Write Buffer Command (3Bh).................................................................................. 49 Synchronize Cache (10) (35h) .......[...]

  • Pagina 11

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 xi Drive Orientation .............................................................................................................. 67 Cooling Requirements ..................................................................................................... 68 Mounting Hole [...]

  • Pagina 12

    xii Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 13

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev 1.0 xiii L IST OF T ABLES 1. Product ID Codes ......................................................................................... 17 2. Data Transfer Rates ..................................................................................... 25 3. Erase Times ..............[...]

  • Pagina 14

    xiv Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 29. Persistent Reserve In ....................................................................................51 30. Persistent Reserve Out .................................................................................51 31. Unsupported Mandatory Commands............[...]

  • Pagina 15

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 xv L IST OF F IGURES 1. The ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive ............................................. 17 2. SCA-2 Interface Connector ........................................................................................... 34 3. Relative SCA-2 Connec[...]

  • Pagina 16

    xvi Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 17

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 17 S COPE Figure 1. The Zeus IOPS 3.5-Inch Fibre Cha nnel Solid State Drive M ANUAL O VERVIEW This product manual describes the applications, s pecifications, and installation of the 3.5-inch Zeus IOPS Fibre Channel Solid State Drive (SSD). See Figure 1 . The contents of thi[...]

  • Pagina 18

    18 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 A UDIENCE This manual is intended for system engineers or system designers employed by an Original Equipment Manufacturer (OEM). This product manual was therefore written specifically for a technically advanced audience; it is not intended for end-users that will eventua[...]

  • Pagina 19

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 19 FC-AL F EATURES This section discusses issues related to the FC-AL ports and loop addressing of the Zeus IOPS 3.5- inch Fibre Channel SSD. This section also provides a table of the SCSI commands implemented on the Zeus IOPS 3.5-inch Fibre Channel SSD, followed by subtopic[...]

  • Pagina 20

    20 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 R EFERENCE D OCUMENTS The following list of ANSI Fibre Channel documents relate to the Zeus IOPS 3.5-inch SSD: • X3.230-1994 FC Physical and Signaling Interface (FC-PH) • X3.297.1997 FC-PH-2 Fibre Channel Ph ysical and Signaling Interface-2 • X3.303.1998 FC-PH-3 Fi[...]

  • Pagina 21

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 21 P ERFORMANCE • Maximum Read of 200 Mbytes/sec • Maximum Write of 100 Mbytes/sec • Cache of 512MBytes • Command queuing of up to 512 commands (256 commands per port) • Background processing of queue P HYSICAL C HARACTERIS TICS • 3.5-inch standard form factor 5.[...]

  • Pagina 22

    22 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 E NVIRONMENTAL C HARACT ERISTICS • Operating Temperature Range – Commercial range of 0°C to 55°C • 0dB Noise Amplitude P OWER • Input Voltage: +12 V DC ± 10% • Typical consumption: – Idle/Standby of 5.4W – Read of 8.4W – Write of 8.1W[...]

  • Pagina 23

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 23 P RODUCT D ESCRIPTION G ENERAL D ESCRIPTION The Zeus IOPS 3.5-inch Fibre Channel Solid State Driv e (SSD) incorporates advanced Single-Level Cell (SLC) NAND flash memory technology to deliv er a state-of-the-art, non-volatile mass storage device. The interface is fully SC[...]

  • Pagina 24

    24 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 P ERFORMANCE C HARACTERISTICS E NDURANCE The useful life of the flash media is limited by the number of write/erase operations that can be performed on the media. Typically, the write/er ase cycles for flash media ranges between 100,000 and 300,000. To extend the life of[...]

  • Pagina 25

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 25 M OUNT T IME The amount of time required to initialize and mount a Zeus IOPS SSD varies according to the operating system (Windows®, Linux®, etc.) and the storage capacity of the drive. A CCESS T IME Unlike a magnetic rotating disk, the Zeus IOPS SSD has no moving read/[...]

  • Pagina 26

    26 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 E RASE T IMES The time required to erase a Zeus IOPS SSD varies according to the total capacity of the drive. The Erase utility will erase every physical memory storage location that can be accessed by the host interface. It will also destroy any saved messages. Once ini[...]

  • Pagina 27

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 27 C ACHE O PERATIONS The Zeus IOPS SSD is configured with 512 MB of cache. Write data can be flushed to the cache with the Synchronize Cache command. H OT P LUGGING The Zeus IOPS 3.5-inch Fibre Channel SSD can be inserted or removed from a loop during operation. This capabi[...]

  • Pagina 28

    28 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 E LECTRICAL S PECIFICATIONS P OWER S UPPLY The following voltage specification applies to t he drive power connector. Connections to the drive should be made in a safety extra low voltage (SELV) circuit. The drive does not use the +5V supply input pins availabl e on a ty[...]

  • Pagina 29

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 29 G ROUNDING Signal and chassis ground are not connected together in the drive. To ensure minimal EM emissions, the user should provide maximu m surface contact area when connec ting the drive to chassis ground. F AULT LED O UT S IGNA L The Fault LED Out signal is driven by[...]

  • Pagina 30

    30 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 SEL_ID F UNCTION The SEL_ n (TTL compatible) inputs (defined when -Par allel ESI is de-asserted) provide a binary value of a loop identifier to the drive. These seven (7) signals define 128 possible values and are directly translated into an 8 bit hard Arbitrated Loop Ph[...]

  • Pagina 31

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 31 P_ESI_ n F UNCT ION The SEL_N (TTL compatible) inputs and outputs (defi ned when -Parallel ESI is asserted) provide an interface between the enclosure and the drive. Table 8 summarizes the signals. Table 8. SEL_N/P_ESI_N Signal Definitions SFF-8045 E NCLOSURE S ERVICE I N[...]

  • Pagina 32

    32 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 -D RIVE P RESENT This signal is connected to the ground plane of the drive. The backplane can use this signal to detect the presence of the drive. D EV _C TRL _C OD E _ X The DEV_CTRL_CODE_2 through D EV_CTRL_CODE_0 signals provide a binary code to the drive to control f[...]

  • Pagina 33

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 33 I NTERFACE S PECIFICATIONS SSD O PERATION The Zeus IOPS Fibre Channel SSD is comprised of the fo llowing primary functional blocks: the SCA- 2 interface connector, a Host FPGA, which contains a processor, NAND FP GA, NAND flash memory, and DRAM. Read/write data transfer r[...]

  • Pagina 34

    34 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 SCSI I NTERFACE B LOCK This section provides information on the SCA-2 connector of the Zeus IOPS Fibre Channel SSD. SCA-2 I NTERFACE C ONNECTOR The 3.5-inch SSD is equipped with a 40-pin SCA-2 bus connector. The connector is located on the underside of the drive. DC powe[...]

  • Pagina 35

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 35 C ONNECTOR L OCATION Figure 3 shows the relative location of the SCA-2 connecto r on the rear of the SSD. Please note the location of Pin 1 relative to the connector. Figure 3. Relative SCA-2 Connector Location[...]

  • Pagina 36

    36 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 C ONNECTOR P INOUT This section provides the pinout of the 40-pin SC A-2 connector, the pinout signal characteristics, and the use of the pinout signals with respect to the SSD. Refer to Table 10 for the 40-pin SCA-2 connector pin-out. Table 10. 40-Pin SCA-2 Connector Pi[...]

  • Pagina 37

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 37 FC-AL F EATURES L OOP C ONNECTIO NS The Zeus IOPS 3.5-inch Fibre Channel SSD features tw o independent FC-AL ports. These ports may be connected in different loops or the same loop. In addition, the drive can send transfers while receiving frames on both ports. Th is capa[...]

  • Pagina 38

    38 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 FCP-SCSI C OMMANDS S UPPORTED SCSI C OMMANDS Table 12 summarizes the SCSI commands supported by the Zeus IOPS SSD. Command queuing is supported with all tag types (Head of Queue, Or dered Queue and Simple Queue). A maximum of 256 commands may be queued against each fibre[...]

  • Pagina 39

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 39 R EPORT L UNS (A0h) The REPORT LUNS command will request that the peripheral device logical unit inventory accessible to the I_T nexus be sent to the application client. The logical unit inventory is a list that shall include the logical unit numbers of all logical units [...]

  • Pagina 40

    40 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 T EST U NIT R EADY C OMMAND (00h) The TEST UNIT READY command provides a method to check if the logical unit is ready. Thi s is not a request for a self-test. If the logical unit would accept an appropriate medium-access command without returning CHECK CONDITION status, [...]

  • Pagina 41

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 41 W RITE (6) C OMMAND (0Ah) The WRITE (6) command requests that the target wr ite the data transferred by the initiator to the medium . The logical block address field specifies the l ogical block at which the write operation s hal l be gi n. The transfer lengt h field spec[...]

  • Pagina 42

    42 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 An EVPD bit of zero specifies that the driv e return the standard INQUIRY data. If the page code field is not zero, the target shall return CHECK CONDITION status with the sense key set t o ILLEGAL REQUEST and an additional sense code of INVALID FI ELD IN CDB. The pag e [...]

  • Pagina 43

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 43 M ODE S ENSE (6) C OMMAND (1 Ah) The MODE SENSE (6) command provides a means for a target to report parameters to the initiator. It is a complementary to the MODE SELECT (6) command. See Tables 19 and 20 . A Disable Block Descriptors (DBD) bit of zero indicate s that the [...]

  • Pagina 44

    44 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 S END D IAGNOSTIC P AGE (1Dh ) The SEND DIAGNOSTIC command is a six byte CD B. The Parameter List Length is two bytes (Bytes 2 and 4). Bytes 1 through 5 are ignored. Table 21. Send Diagnostics CDB Bit Byte 7 6 5 4 3 2 1 0 0 Operation Code (1Dh) 1 Logical Unit Number (RSV[...]

  • Pagina 45

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 45 L OG S ENSE C OMMAND (4Dh) The LOG SENSE command provides a method for the applicat ion client to retrieve statistical or other operational information maintained by the SCSI ta rget device about the SCSI target device or its logical units. The command is complementary to[...]

  • Pagina 46

    46 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 R EAD C APACITY (25h) The READ CAPACITY c ommand provides a means for the ini tiator to r equest information regarding the capacity of the logical unit. Bytes 1 throug h 9 are ignored. If a Byt e 8 is a non-zero, Illegal command will be returned. Table 23. Read Capa city[...]

  • Pagina 47

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 47 R EAD E XTENDED (10) (2 8h) The READ (10) EXTENDED (28h) command requests that the target transfer data to the initiator. The most recent data value written in the addressed l ogical block is returned. Byte 1 and Byte 9 are ignored. Table 24 . Read Extended (10) CDB Bit B[...]

  • Pagina 48

    48 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 W RITE E XTENDED (10) (2Ah ) The WRITE (10) EXTENDED (2Ah) command requests that the drive write the data transferred by the initiator to the medium. Bytes 1 and 9 are ignored. W RITE AND V ERIFY (10) (2Eh) The WRPROTECT field and DPO and BYTCHK bi ts in CDB Byte 1 are a[...]

  • Pagina 49

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 49 W RITE B UFFER C OMMAND (3Bh) The WRITE BUFFER command is complementary to the READ BUFFER command as a diagnostic function for testing logical unit memory in the SC SI target device and the integrity of the service delivery subsystem. Table 26. Write Buffer Command (3Bh)[...]

  • Pagina 50

    50 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 M ODE S ENSE (10) C OMMAND (5Ah) The MODE SENSE (10) command provi des a means for a target to report parameters to th e initiat or. It is complementary to the MODE SELECT (10) command. Byte 9 is ignored. Table 27. Mode Sense (10) Command (5Ah) A Disable Block Descriptor[...]

  • Pagina 51

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 51 P ERSISTENT R ESERVE I N (5Eh) C OMMAND The PERSISTENT RESERVE IN (5Eh) command will obtain information about persistent reservations and reservation keys that are ac tive within the device server. The comma nd is complementary to the PERSISTENT RESERVE OU T (5Fh) command[...]

  • Pagina 52

    52 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 U NSUPPORTED C OMMANDS Table 31 lists the mandatory commands that are not supported by the Zeus IOP S drive. Table 31. Unsupported Man datory Commands Command Command Code Description Request Sense 03h Device returns sense data with every failed comm and as part of respo[...]

  • Pagina 53

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 53 F IBRE C HANNEL S TANDARD The Fibre Channel standard has coined various terms that are important to know when using the Zeus IOPS SSD. This section will present the basic terms in context to help provide an intuitive understanding of the Fibre Channel interface. F IBRE C [...]

  • Pagina 54

    54 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 An Arbitrated Loop has certain rules: 1 Each port on the loop has an Arbitrated Loop Physical Address (AL-PA) that is set on t he “backplane” or the board to w here the device is connected. Once set, the port attached to the backplane inherits the AL-PA. 2 The AL-PA [...]

  • Pagina 55

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 55 F ABRIC N ODE C ONNECTIO N The Zeus IOPS SSD can also be connected to a “fabric” where any node on the fabric can connect to any other node in the fabric. See Figure 5 . Figure 5. Fabric Node Con nection[...]

  • Pagina 56

    56 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 An Arbitrated Loop has the following states: A node can be “hot plugged” where it is inserted or removed from the loop. When hot plugged, the loop loses “sync” and must “reini tialize”. The loop will be able to recover any lost communications during the hot p[...]

  • Pagina 57

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 57 The Fibre Channel standard is structured into FCP Function Levels, where “FCP” is “Fibre Channel Protocol”. There is a hierarchy of function levels , written FC-0 to FC-4, and on top of those lies the Upper Level Protocols or ULP. Table 32 summarizes each FCP leve[...]

  • Pagina 58

    58 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 P HYSICAL C HARACTERISTICS G ENERAL P HYSICAL C HARACTERIST ICS M ATERIALS All acceptable enclosure materials have been independent ly tested by an NRTL and are certified to comply with the following standards: • ANSI/UL60950-1-2002 • CAN/CSA-C22.2 No.60950-1-03 D RI[...]

  • Pagina 59

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 59 E XTERIOR D IMENSIONS Zeus IOPS SSD internal components are housed within precision machined aluminum alloy enclosures. The overall dimensions for the 3.5-inch form factor are illustrated in Figure 7 . Figure 7. Zeus IOPS 3.5-Inch Dimensi on s[...]

  • Pagina 60

    60 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 E NVIRONMENTAL C HARACTERISTICS O VERVIEW Zeus IOPS SSDs are subjected to a series of environm ental tests to validate the portability and suitability of the SSDs for operation in harsh and mobile conditions. The SSDs operate without degradation within the ambient temper[...]

  • Pagina 61

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 61 M AXIMUM C OMPONENT T EMPERA TURES Critical drive component temperatures must be kept within certain limits to prevent damage to the SSD. The approximate component locations wi thin the drive are illustrated in Figure 8 . Table 36 lists the maximum component temperatures.[...]

  • Pagina 62

    62 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 I NSTALLATION S YSTEM R EQUIREMENTS SCSI C ONNECTIONS The Zeus IOPS 3.5-inch Fibre Channel SSD can be instal led in an operating system environment that supports SCSI-3 or greater dev ices (the SSDs are intended to be compliant to future SCSI-4 standards). If the system [...]

  • Pagina 63

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 63 For host systems that are not DMP capable, having two paths from the same host machine to the same drive can cause problems. For example, if the two channels are connected to the same host machine when running an operating system that does not support DMP, two separate di[...]

  • Pagina 64

    64 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 P OWER -O N F AULT C ONDITIONS The fault codes listed in Table 37 indicate that a fault has been detected during the power-on sequence. As a result, the unit is in a non-operational state and remedial action is required to replace the unit. Power-on fault codes are indic[...]

  • Pagina 65

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 65 O PERATIONAL F AULT C OD ES The following codes indicate that a fault has been detected during drive oper ation. The drive will remain operational despite the fault. The drive s hould be replaced at the earliest possible opportunity. Operational fault codes are indicat ed[...]

  • Pagina 66

    66 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 S INGLE C HANNEL M ODE FOR E ARLY R EVISION D RIVES On early revisions of the drive, JP1 did not exist. These drives are identified by having a serial number of “50” or less and only have an 8-way right-angl ed manufacturing connector. For this revision of drive, the[...]

  • Pagina 67

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 67 D RIVE O RIENTATION The SSD can be installed in any number of orientat ions within the enclosure. The drive will operate and meet all the requirements as outlined in this spec ification regardless of the mounting orientation. See Figure 9 . Figure 9. Possible Drive Orient[...]

  • Pagina 68

    68 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 C OOLING R EQUIREMENTS If necessary to maintain the required operating te mperature range, the host enclosure may remove heat by conduction, convection, or other forced air flow. The suggested air flow patterns are shown in Figure 10 . Figure 10. Suggested Air Flow Patte[...]

  • Pagina 69

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 69 M OUNTING H OLE D IMENSIONS Figure 11 shows relative locations of the mounting holes. Careful attention should be made to the length of the mounting screws and the recommended to rque to prevent damage to the enclosure; the maximum screw penetration is 5 mm. The mounting [...]

  • Pagina 70

    70 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 D RIVE I NSTALLATIO N To install the SDD in a server or host system: 1 Power down the computer/host system. 2 Remove the access cover. 3 Position the SSD in an available drive bay or choose a suitable mounting location. 4 Connect the SSD to the backplane or tailgate ca r[...]

  • Pagina 71

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 71 O PERATING S YSTEM S PECIFICAT IONS The Zeus IOPS SSDs are compatible with Microsoft Windows® and alternative operating systems. The SSDs are low-level formatted at the factor y. However, the SSDs must be partitioned and high- level formatted. The SSDs can be formatted a[...]

  • Pagina 72

    72 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 SSD M ANAGEM ENT U TILITY The firmware and hardware on a Zeus IOPS SSD can be upgraded in the field. The drive management utility, “Giddy”, uses signed Java applet technology and the Java native interface to maintain the SSD. Table 40 lists the supported operating sy[...]

  • Pagina 73

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 73 NAND F LASH S UPPORT The device will support multiple mutually agr eed upon and approved NAND flash memory vendors prior to release to manufacturing for proposed capacities in the design without changes to the hardware or firmware. STEC develops firmware to support a wide[...]

  • Pagina 74

    74 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 R EGULATORY C OMPLIANCE M ARKING , A PPROVALS AND S UPPORTING D OCUMENTATION The SSDs will have the following marks, approvals and documentation as outlined in Table 41. Table 41. Regulatory Marks and Documentation R ESTRICTIO N OF H AZAR DOUS M ATERI ALS STEC, Inc., has[...]

  • Pagina 75

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 75 R ADIO F REQUENCY E MI SSIONS The Zeus IOPS SSD has passed radiated emissions testing (10 meter chamber) with a minimum margin of 4dB below the EN55022 radiated emissions limits in all applicabl e customer platforms, without any required changes to the system platforms. E[...]

  • Pagina 76

    76 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 E LECTROST ATIC D ISCHARGE (ESD) The SSDs will meet the ESD limits specifi ed in the 61000-4-2 guidelines and the customer’s enhanced ESD procedure. The specification will deter mine whether the cont act or air discharge method should be used. Performance degradation i[...]

  • Pagina 77

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0 77 C ONTACT AND O RDERING I NFORMATION Contact Information For more information on Zeus IOPS Solid State Drives, contact t he STEC Solid State Drive Team. Ordering Information Telephone: 800-796-4645 (Toll free; U.S. and Canada only) All Others: (949) 260-8345 Fax: (949) 851[...]

  • Pagina 78

    78 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 79

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev 1.0 77 I NDEX A Arbitrated Loop Arbitration ......... ........... ......... .......... 56 Bypass Circuit ......... ........... ......... ... 5 6 Closed ........ ........... ......... ........... ...... 56 Monitoring ......... ........... ......... .......... 56 Open ....... .....[...]

  • Pagina 80

    78 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0 Operating System Specifications .71 Operatio n al Fault Code s ......... ......65 Power-On Fault Con ditions ........ .. .64 SCSI Connections ....... ........... ........ 62 Single Channel Operation ........ .....62 SSD Management Utility ............. ..72 Interface Spe[...]

  • Pagina 81

    Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev 1.0 79 S Scope Audience ......... ......... ........... ......... ... 1 8 Manual Overview ...... ......... ........... . 17 Product ID Codes ......... ........... ...... 17 SCSI Commands Inquiry Command (12h) .... ........... . 41 Log Sense (4 Dh) ...... ........... ......... . 4[...]

  • Pagina 82

    80 Zeus IOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1. 0[...]

  • Pagina 83

    81 C ERTIFICATION AND W ARRANTY FCC Declaration of Conformit y Zeus IOPS Solid Stat e Drives carry the FCC-Mark in acc ordance with related Federal Communication s Commission (FCC)–USA directives. This device c omplie s with Part 15 of the FCC Rules. Operatio n is subject to the following two condit ions: • This device may not cause ha rmful in[...]

  • Pagina 84

    STEC Inc. World Headquarters 3001 Daimler Street Santa Ana, CA 9270 5 USA Tel: 949.260.8345 Fax: 949.417.1335 Web: www.stec-inc.com 61000-04522-101: Revision 1.0[...]