SPX Cooling Technologies FSIG-TS-08A manuale d’uso
- Visualizza on-line o scarica il manuale
- 30 pagine
- 0.77 mb
Vai alla pagina of
Manuali d’uso simili
-
Humidifier
SPX Cooling Technologies Marley NC Class
8 pagine 1.18 mb -
Humidifier
SPX Cooling Technologies MXF 4800
12 pagine 1.71 mb -
Humidifier
SPX Cooling Technologies Air Cooled Condensers
4 pagine 0.69 mb -
Humidifier
SPX Cooling Technologies 7013F081 - 7013J121
28 pagine 0.86 mb -
Humidifier
SPX Cooling Technologies MD-08F
8 pagine 1.13 mb -
Humidifier
SPX Cooling Technologies F400
8 pagine 1.18 mb -
Humidifier
SPX Cooling Technologies 1000
32 pagine 1.58 mb -
Humidifier
SPX Cooling Technologies none
32 pagine 0.25 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso SPX Cooling Technologies FSIG-TS-08A. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica SPX Cooling Technologies FSIG-TS-08A o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso SPX Cooling Technologies FSIG-TS-08A descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso SPX Cooling Technologies FSIG-TS-08A dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo SPX Cooling Technologies FSIG-TS-08A
- nome del fabbricante e anno di fabbricazione SPX Cooling Technologies FSIG-TS-08A
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature SPX Cooling Technologies FSIG-TS-08A
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio SPX Cooling Technologies FSIG-TS-08A non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti SPX Cooling Technologies FSIG-TS-08A e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio SPX Cooling Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche SPX Cooling Technologies FSIG-TS-08A, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo SPX Cooling Technologies FSIG-TS-08A, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso SPX Cooling Technologies FSIG-TS-08A. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
/ Mar le y Sigma F Ser ies Cooling T ower / Engineer ing Data & Specifications[...]
-
Pagina 2
Mar ley / Sigma F Ser ies Cooling T ower / T able of Contents Engineer ing Data Sc hematic 4 Support 5 Piping 7 T emperature Control 1 0 Environmental 1 1 Specifications / Base Base 12 Thermal P erformance 13 Construction 1 4 Fan Dec k and F an Cylinder 15 Mec hanical Equipment 15 Fill, Louvers and Drift Eliminator s 16 Hot W ater Distribution Syst[...]
-
Pagina 3
Mar ley / Sigma F Ser ies Cooling T ower / 3 T he Sigma F Series is a field-erected, crossflow , fiberglass-str ucture cooling to wer designed to ser ve normal air conditioning and refrigeration systems as w ell as medium sized industrial loads. Evolving from the crossflo w concept of cooling tow er pioneered by Marle y in 1 938, and incorporat[...]
-
Pagina 4
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Schematic 4 H B T OP OF F AN CYLINDER BASE OF T OWER COLUMNS F AN DECK 13'-6" N O T E 1 U se this bulletin for preliminary layouts only . Obtain current drawings from y our Marley representative. 2 All table data is per cell. 3 All to wer installations require a minimum of 4&[...]
-
Pagina 5
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Support 5 A SP ACES A T 4'-0" = L W OVERALL OF BASIN SUMP OVERFLOW MAKEUP V AL VE INTERMEDIA TE BEAM AIR INLET F ACE AIR INLET F ACE CASED ENDW ALL F ACE CASED ENDW ALL F ACE PRIMARY SUPP ORT BEAM P L A N E L E V A T I O N N O T E 1 Use this bulletin for preliminary layouts o[...]
-
Pagina 6
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Support 6 A SP ACES AT 4'-0" = L 6 " MIN TYP SUMP SEE NOTE 7 OPTIONAL PA RTITION W ALL FOR INDIVIDU AL CELL OPERA TION B B P AIR INLET F ACE AIR INLET F ACE CASED ENDW ALL F ACE CASED ENDW ALL F ACE W IN T O IN OF CURB WALLS P L A N 1 ' -6 " 1 ' -0 " [...]
-
Pagina 7
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Piping Plan 2 7 C MOTOR C F COLUMN AND ANCHOR BOLT TYP. SINGLE CELL D TYP. MULTICELL C L COLUMN AND ANCHOR BOLT C L INLET C L TOWER AND FAN C L FAN C L FAN C L INLET C L INLET C L F FAN TOWER C L INLET C L MOTOR CONCRETE BASIN OPTION B DIAMETER CROSSOVER PIPE STAINLESS STEEL BASIN OPTI[...]
-
Pagina 8
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Piping Plan 3 8 C H MO TO R C F COLUMN AND ANCHOR BOL T TY P. SINGLE CELL D TY P. MUL TICELL C L COLUMN AND ANCHOR BOL T C L RISER C L T OWER AND F AN C L FA N C L FA N C L RISER C L P L A N F FA NT OWER C L INLET RISER C L MO TO R CONCRETE BASIN OPTION B DIAMETER CROSSOVER PIPE 26 &qu[...]
-
Pagina 9
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata : Piping Plan 4 9 C H MO TO R C F COLUMN AND ANCHOR BOL T TY P. SINGLE CELL D TY P. MUL TICELL C L COLUMN AND ANCHOR BOL T C L RISER AND HEADER C L T OWER AND F AN C L FA N C L FA N C L RISER C L H E G F AN FLANGE IS 3 / 4 " THICK. BOL T CIRCLE CONFORMS T O 125 LB. ANSI SPECIFICA TI[...]
-
Pagina 10
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata: Energ y Management 10 CAUTION The cooling tower must be located at suc h distance and direction to avoid the possibility of contaminated tower disc harge air being drawn into building fresh air intake ducts. The purc haser should obtain the services of a Licensed Professional Engineer o[...]
-
Pagina 11
Mar ley / Sigma F Ser ies Cooling T ower / Engineer ing D ata: Envir onmental 11 Sound Control Sound produced by a Sigma to wer operating in an unobstructed environment will meet all but the most restrictiv e noise limit a- tions—and will react fa vorably to natural at tenuation. Where the tow er has been sized to operate within an enclosure, the[...]
-
Pagina 12
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 12 1.0 Base: 1.1 Furnish and inst all an induced-draft, crossflow-type, field-erected, structural fiberglass-framed, P VC film-fill, industrial- duty cooling tower of _____ cell(s), as shown on Plans. The limiting overall dimensions of the tower shal[...]
-
Pagina 13
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 13 2.0 Ther mal P erfor mance: 2.1 The tow er shall be capable of cooling _____ GPM of water from ____ °F to _____ °F at a design entering air wet- bulb temperature of _____ °F . The cool- ing tower manufacturer shall guarantee that the tower supp[...]
-
Pagina 14
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 14 3.0 Constr uction: 3.1 The tow er shall be capable of with- standing water having a pH of 6.5 to 8.0; a c hloride content (NaCl) up to 750 ppm; a sulfate content (SO 4 ) up to 1 20 0 ppm; a calcium content (CaCO 3 ) up to 80 0 ppm; silica (SiO 2 )[...]
-
Pagina 15
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 15 4.0 F an Deck and F an Cylinder: 4.1 The fan dec k shall act as a working platform for maintenance personnel. It shall consist of 1 1/8" (28.5 mm) deep pultruded fiberglass interloc king pan- els, supported by structural fiberglass joists o[...]
-
Pagina 16
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 16 5.4 A st ainless steel oil fill and drain line shall extend from the gear reducer to the vicinit y of the motor , and shall be equipped with a bronze-bodied oil lev el sight-glass gauge. 5.5 The complete mec hanical equipment assembly for eac h c[...]
-
Pagina 17
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 17 7.0 Hot W ater Distribution Syst em: 7.1 The mechanical equipment support/ crossover pipe for each cell shall be equipped with a flange for the attachment of customer supply piping. Inlet and bolt circle dimensions shall conform to 125# flange spe[...]
-
Pagina 18
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 18 9.0 Access and Saf ety: 9.1 Single cell towers shall include a 33" (838 mm) wide by 61" (1 .55 m) high molded FRP access door in one endwall casing for access to the inte- rior of the tow er . Casing access door shall be hinged and equip[...]
-
Pagina 19
Specifications Specification V alue Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Base 19 11.0 Scope of Wor k : 11.1 The cooling tow er manufact urer shall be responsible for the design, fabrica- tion, and deliver y of materials to the project site, and for the erection of the tower over supports pro vided by others. Unless other wise [...]
-
Pagina 20
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 20 Specification V alue Cold W ater Basin Options Stainless Steel Cold W ater Basin : 10.1 Replace paragraph 1 0.1 with the following: Include a cold water col- lection basin constructed of 1 2 gauge series 304 st ainless steel, through- bolted and sealed to prevent l[...]
-
Pagina 21
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 21 Specification V alue and a solid state circuit board for tem- perature control and low water cutof f . A control probe shall be located in the basin to monitor water lev el and tem- perature. The system shall be capable of maint aining 40°F water temperature at an[...]
-
Pagina 22
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 22 Specification V alue Plenum W alkwa y: 9.1 Add the following to the end of this paragraph: Pro vide a 30" (7 62 mm) minimum wide walkwa y extending from one endwall access door to the other through the length of the tow er . W alkway shall be constructed of ?[...]
-
Pagina 23
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 23 Specification V alue Air Inlet Screens: 6.3 Add the following paragraph in the Fill, Louver s and Drift Eliminator s section: The air inlet faces of the tow er shall be covered by 1" mesh stainless steel w elded wire screens. Screens shall be secured to st ain[...]
-
Pagina 24
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 24 Specification V alue Control Options Control Syst em: 5.7 Add the following paragraphs in the Mechanical Equipment sec- tion: Each cell of the cooling to wer shall be equipped with a UL listed control system in a NEMA 3R or 4X outdoor enclosure capable of control- [...]
-
Pagina 25
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 25 Specification V alue F an Motor V ariable Speed Dr ive: Marle y All W eather ACH550 System 6.4 Add the following paragraph in the Mec hanical Equipment section when VFD is used with customer s Building Management System: A complete UL listed V ariable Speed Drive s[...]
-
Pagina 26
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 26 Specification V alue and cooling is no longer required. The fluid cooler manufact urer shall supply VFD st art-up assistance. T ower vibration testing throughout the speed range is required to identify and lock out any natu- ral frequency vibration lev els whic h [...]
-
Pagina 27
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 27 Specification V alue ■ Unless specified otherwise, a Robertshaw or Metrix switch will be provided. Double-pole, double-throw models are also avail- able. If purc hased in conjunction with the Control System, it is also factory- wired. The requirement for manual [...]
-
Pagina 28
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 28 Specification V alue Fiberglass Ladder: 9.3 Change paragraph 9.3 to read as follows: One endwall of the tow er shall be equipped with an 18" (457 mm) wide fiberglass vertical ladder , supported by hot-dip galvanized steel brac kets through-bolted to the endwa[...]
-
Pagina 29
Specifications Mar ley / Sigma F Ser ies Cooling T ower / Specifications: Options 29 Specification V alue[...]
-
Pagina 30
7 4 01 WEST 1 29 STRE ET OVER LAN D P AR K, KANSAS 6 621 3 U N ITE D ST A TES 913 6 64 7 400 spxcooling@ct.spx.com spxcooling.com In the interest of techno logical progr ess, all products are subject to design and/or material change without notice. ©2008 SPX Cooling T ech nologies , Inc. Printed in USA | FSIG-T S -08A[...]