Vai alla pagina of
Manuali d’uso simili
-
Battery Charger
Studer Innotec C 1600-12, C 2600-24, C 4000-48
23 pagine 0.65 mb -
Battery Charger
Studer Innotec XPC 1400-12
23 pagine 0.49 mb -
Battery Charger
Studer Innotec C-IP23
25 pagine 1.01 mb -
Battery Charger
Studer Innotec XPC 2200-24
23 pagine 0.49 mb -
Battery Charger
Studer Innotec XPC 1112
22 pagine 1.09 mb -
Battery Charger
Studer Innotec C2324 COMPACT
23 pagine 1.14 mb -
Battery Charger
Studer Innotec XTH 8000-48
36 pagine 0.58 mb -
Battery Charger
Studer Innotec HPC2512
25 pagine 0.63 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Studer Innotec XPC 1648. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Studer Innotec XPC 1648 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Studer Innotec XPC 1648 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Studer Innotec XPC 1648 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Studer Innotec XPC 1648
- nome del fabbricante e anno di fabbricazione Studer Innotec XPC 1648
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Studer Innotec XPC 1648
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Studer Innotec XPC 1648 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Studer Innotec XPC 1648 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Studer Innotec in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Studer Innotec XPC 1648, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Studer Innotec XPC 1648, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Studer Innotec XPC 1648. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
STUDER INNOTEC XP- COMPACT User and installer Manual Combi Inverter, Battery charger and Transfersystem XP-COMPACT XPC 1112 XP-COMPACT XPC 1624 XP-COMPACT XPC 1648 Remote control RCC-01 Temperature sensor CT-35 Solar charge controller XPCxxxx-S AC cable cover CFC-01 IP-23 top cover C-IP23 User manual XP-COMPACT V2.0 E STUDER INNOTEC TEL: ++41 (0)27[...]
-
Pagina 2
STUDER INNOTEC XP- COMPACT Summary 1 General Information ............................................................................................................ ..... 3 1.1 O PERATING INSTRUCTIONS ............................................................................................................................... .3 1.2 Q UALITY AND [...]
-
Pagina 3
STUDER INNOTEC XP- COMPACT 4.8.3 Delaye d mode of th e Transfer System ............................................................................................ ............. 15 4.9 T HE S OLAR CHARGE CONTROLLER ( OPTION ) .................................................................................................... 15 4.10 T HE M ULTIFUNC[...]
-
Pagina 4
STUDER INNOTEC XP- COMPACT 1 General Information 1.1 Operating instructions This manual is a part of the delivery package of every XP-COMPACT inverter-charger. It serves as guidelines for safe and efficient operation of XP-COMPACT. The instructions are only valid for use with the following appliances and options: - XP-COMPACT XPC1112 - XP-COMPACT X[...]
-
Pagina 5
STUDER INNOTEC XP- COMPACT 1.5 Precautions This manual must be readily available for the user at all times. The user must be familiar with the precautions and safety aspects. During operation of XP-COMPACT, high voltages are generated at the connections and inside of the appliance which could be deadly fatal. Work on the appliance and on the instal[...]
-
Pagina 6
STUDER INNOTEC XP- COMPACT 2 Introduction The XP-COMPACT is a sine wave inverter with integrated battery charger and solar charge con- troller with many additional functions, it has been developed to be used as stand-alone (no grid feeding) AC provider, or as continuous / break-free current supply provider (UPS). 2.1 Principle schematic 6p 8p RJ11 [...]
-
Pagina 7
STUDER INNOTEC XP- COMPACT technical specification (chap.6). The battery ch arger is meant for the lead-acid and lead-gel batter- ies. Thanks to the floating charge system the ba ttery can remain continuously connected. 2.2.4 The solar charge controller (optional) With the built-in solar charge controller, the XP-C OMPACT is a complet e solar-power[...]
-
Pagina 8
STUDER INNOTEC XP- COMPACT 2.3.3 Connection in parallel and in serie 12V 12V 12V 12V 24V 3 Mounting and installing 3.1 Installation place The location of the XP-COMPACT must be chosen by the following criteria: - Protection against unauthorized handling - Dry dust free room, no condensation - Never install directly over the battery and nev er in a [...]
-
Pagina 9
STUDER INNOTEC XP- COMPACT Connecting must be done by qualified staff. Material such as cab l e, connectors and distribution boxes, fuses etc. used in the installation must comply with the respective valid low-voltage installa- tion rules and regulations. 3.4.2 Protection cover for the terminals con- nections The protection cover is available in op[...]
-
Pagina 10
STUDER INNOTEC XP- COMPACT 3.6 Cabling/wiring Connecting of the XP-COMPACT is a very important step in the installation. You must take care that all connecting work is carried out in a clean and correct manner and that under no circum- stance a cable is connected to a wrong terminal. Connecting of the XP-COMPACT must be carried out in the following[...]
-
Pagina 11
STUDER INNOTEC XP- COMPACT 3.6.6 Connection to Auxiliary Contact On these three terminals is a potential free change-over contact. The maximal permitted current and voltage for this is 16A/250Vac. The LED 5 “Contac t active” shows the position of them: alight means active and off means non-active . The schematic view of the connections on the f[...]
-
Pagina 12
STUDER INNOTEC XP- COMPACT 4.2 Display and control parameters on remote control panel (optional) 16 0 OFF AC OUT Over Temp. Overload AC IN SOLAR CHARGE Contact manual Contact active Program COMPA CT AUXILIARY CONTACT ON/OFF INVERTER - CHARGER (Select) RCC-01 INV ERT ER CHARGER (Program ) (Change s tatus) Ba tte ry Low/High RESET ALARM 10 20 30 40 5[...]
-
Pagina 13
STUDER INNOTEC XP- COMPACT 13 OFF XP-COMPACT is turned off. Turn- ing it back on is only possible manually. XP-COMPACT is for the time be- ing turned off. Turning it back on will follow automatically! 14 Battery Charger and/or Solar Charge Controller are doing an equalization cycle 15-18* Charge condition of Battery LED 15 – Absorption time is ru[...]
-
Pagina 14
STUDER INNOTEC XP- COMPACT User manual XP-COMPACT V2.0 E 13 perature synchronizes the relay with the alarm signal. In this way, for exa m ple, an emergency back up system can be started without any break in the energy supply. 4.6.4 Battery Condition Deep discharging of the lead-acid batteries leads to high losses in capacity and early aging. This i[...]
-
Pagina 15
STUDER INNOTEC XP- COMPACT 4.7.2 Equalization charging Before you program the XP-COMPACT for Equalizat ion-charge you must check with your supplier that the batteries are suitable for this process. Equalization is recommended for the lead-acid batteries in order to mix well the electrolyte fluid and to clean the lead plates. Equalization mode shoul[...]
-
Pagina 16
STUDER INNOTEC XP- COMPACT the transfer contact is active, then you have at the output AC OUT the same voltag e as that at the input. This voltage can not be modified by the XP-COMPACT! 4.8.1 Set the transfer voltage threshold The voltage threshold of the transfer is factory settled at 200Vac. This value is acceptable in most application. However, [...]
-
Pagina 17
STUDER INNOTEC XP- COMPACT 4.10 The Multifunctional Contact In the XP-COMPACT there is a built-in power rel ay. The potential-free change-over contact (NO – NC) of this power relay is connected to the screw terminal AUX CONTACT. Maximum Contact load: 230V ac /12Vdc/24Vdc/16Amp 60Vdc/3 Amp. ! The contact is activated when t he XP-COMPACT is halted[...]
-
Pagina 18
STUDER INNOTEC XP- COMPACT 5.3 Battery Condition Built-in microprocessor calculates the actual state of charge of the battery and displays it on L ED 15 – 18. The LED 14 is lit when the system is carrying out a charge cycle with equalization. The voltage levels and charge characteristics can be changed through Programming. The instruc- tion for p[...]
-
Pagina 19
STUDER INNOTEC XP- COMPACT 6.1 Standard setting The XP-COMPACT is delivered with the following default setting: 6.1.1 Battery voltage Low voltage 11.6V / 23.2V / 46.4V Float Charge 13.5V / 27.0V / 54.0V End of Charge Voltage 14.4V / 28.8V / 57.6V Equalization 15.3V / 30.6V / 61.2V Absorption Time: 2 Hours 6.1.2 Auxiliary c ontact Active in case of [...]
-
Pagina 20
STUDER INNOTEC XP- COMPACT table 6.3.1. If desired, repeat the operation with any other parameter (voltage or time) to be changed. If during 10 seconds no buttons are pressed, the selected values are automatically stored and the XP-COMPACT switches back in to the normal operating status. The voltage levels and times changed through progra mming are[...]
-
Pagina 21
STUDER INNOTEC XP- COMPACT 6.4.3.3 Second priority cut-off The Auxiliary Contact can use to cut-off second priori ty load with the criteria of the battery status or overtemp. One of the 4 LED 15 to 18 or 10 will be chosen as the cut off criteria. The second prior- ity loads will be supply only if the ba ttery as a sufficient residual capacity 6.5 D[...]
-
Pagina 22
STUDER INNOTEC XP- COMPACT User manual XP-COMPACT V2.0 E 21 9 Technical Data Model XPC1112 XPC1624 XPC1648 Inverter Nominal battery voltage 12 V 24 V 48 V Input voltage range 9.5 – 17 V 19 – 34 V 38 – 68 V Nominal power 1100 W 1600 W 1600 W Maximum power load 30 min. P30 1400 W 2200 W 2000 W Maximum power load 5 sec 3 x Pnom Maximum load up t[...]