Sun Microsystems FASTETHERNET 6U manuale d’uso
- Visualizza on-line o scarica il manuale
- 106 pagine
- 1.17 mb
Vai alla pagina of
Manuali d’uso simili
-
Network Card
Sun Microsystems Sun Fire X4100 M2
50 pagine 3.34 mb -
Network Card
Sun Microsystems JDBC/ODBC Adapter
133 pagine 2.48 mb -
Network Card
Sun Microsystems none
36 pagine 0.06 mb -
Network Card
Sun Microsystems X4100 M2
50 pagine 3.18 mb -
Network Card
Sun Microsystems TIERWOLF 9740
100 pagine 1.68 mb -
Network Card
Sun Microsystems 2.0
64 pagine 2.15 mb -
Network Card
Sun Microsystems Smart Cards
14 pagine 0.22 mb -
Network Card
Sun Microsystems Gigabit Ethernet MMF/UTP Adapter
122 pagine 1.68 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Sun Microsystems FASTETHERNET 6U. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Sun Microsystems FASTETHERNET 6U o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Sun Microsystems FASTETHERNET 6U descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Sun Microsystems FASTETHERNET 6U dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Sun Microsystems FASTETHERNET 6U
- nome del fabbricante e anno di fabbricazione Sun Microsystems FASTETHERNET 6U
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Sun Microsystems FASTETHERNET 6U
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Sun Microsystems FASTETHERNET 6U non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Sun Microsystems FASTETHERNET 6U e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Sun Microsystems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Sun Microsystems FASTETHERNET 6U, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Sun Microsystems FASTETHERNET 6U, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Sun Microsystems FASTETHERNET 6U. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Sun Microsystems, Inc. 901 San Antonio Road P alo Alto , CA 94303 U .S.A. 650-960-1300 Send comments about this document to: docfeedback@sun.com Sun Quad F astEther net ™ 6U CompactPCI Adapter Installation and User’ s Guide P ar t No . 806-2991-10 June 2000, Re vision A[...]
-
Pagina 2
Please Recycle Copyright 2000 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303-4900 USA. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be repr oduced in any form by any m[...]
-
Pagina 3
iii Regulatory Compliance Statements Y our Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • V oluntary Contr ol Council for Interference (VCCI) — Japan • Bureau of Standar ds Metrology and Inspection [...]
-
Pagina 4
iv Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 ICES-003 Class A Notice - A vis NMB-003, Classe A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. ICES-003 Class B Notice - A vis NMB-003, Classe B This Cl[...]
-
Pagina 5
Regulator y Compliance Statements v BSMI Class A Notice The following statement is applicable to products shipped to T aiwan and marked as Class A on the pr oduct compliance label.[...]
-
Pagina 6
vi Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000[...]
-
Pagina 7
vii Contents Preface xv 1. Overview of the Sun Quad FastEthernet 6U CompactPCI Adapter 1 Product Description 2 Features 3 Overview of the Installation Procedur e 4 Installation Methods 4 Models of Hot Swap 4 Installing the Rear-Access Adapter 5 Installing the Front-Access Adapter 6 2. Installing the Rear-Access Adapter 7 Preparing for the Installat[...]
-
Pagina 8
viii Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000 Installing the Rear-Access Adapter in Cold-Swap Mode 21 ▼ T o Power Of f the Server 21 ▼ T o Install the Rear T ransition Card 22 ▼ T o Install the Rear -Access Front Car d 23 ▼ T o Power On the Server 25 Connecting the Cables to the Rear T ransit[...]
-
Pagina 9
Contents ix Booting the System Over a Sun Quad FastEthernet Interface 48 ▼ T o Boot the System Over the Network 48 A. Specif ications 51 Ethernet Port Locations and Descriptions 52 Operation Specifications 53 Physical Dimensions 54 Physical Dimensions of the Rear-Access Adapter 54 Physical Dimensions of the Front-Access Adapter 55 Environmental S[...]
-
Pagina 10
x Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000 Disabling the Network Interfaces and Removing the Adapter 76 ▼ T o Disable the Network Interfaces and Remove the Adapter 76 Replacing the Adapter and Activating the Network Interfaces 78 ▼ T o Replace the Adapter and Activate the Network Interfaces 78 D.[...]
-
Pagina 11
xi Figur es FIGURE 1-1 Sun Quad FastEthernet 6U CompactPCI Adapter (Rear-Access Version) 2 FIGURE 1-2 Sun Quad FastEthernet 6U CompactPCI Adapter (Front-Access Version) 3 FIGURE 2-1 CompactPCI Slot Pairs in a Sun Netra ct 800 Server (Top View) 9 FIGURE 2-2 Location of the Rear Transition Card’s Ejection Levers 11 FIGURE 2-3 Opening the Ejection L[...]
-
Pagina 12
xii Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 FIGURE 3-6 Ejection Lever Tabs Installed in the Slot’s Cutouts (Two Types of Levers) 33 FIGURE 3-7 Location of the Front-Access Adapter’s Hot-Swap LED 33 FIGURE 3-8 Tightening the Ejection Lever Captive Screws (Two Types of Levers) 35 FIGURE 3-9 Con[...]
-
Pagina 13
xiii T ables T ABLE 1-1 Rear-Access Installation Overview 5 T ABLE 1-2 Front-Access Installation Overview 6 T ABLE A-1 Pin Descriptions for the Four 8-Pin RJ-45 Connectors (Ports 0 to 3) 53 T ABLE A-2 Operation Specifications 53 T ABLE A-3 Physical Dimensions (Rear-Access) 54 T ABLE A-4 Physical Dimensions (Front-Access) 55 T ABLE A-5 Environmental[...]
-
Pagina 14
xiv Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000[...]
-
Pagina 15
xv Pr eface The Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User ’ s Guide provides installation and conf iguration instructions for the Sun Quad FastEthernet™ 6U CompactPCI adapter . These instructions are designed for system administrators with experience installing similar hardwar e. How This Book Is Or ganized This manual c[...]
-
Pagina 16
xvi Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000 Using UNIX Commands This document may not contain information on basic UNIX ® commands and procedur es such as shutting down the system, booting the system, and configuring devices. See one or more of the following for this information: ■ Solaris Handbo[...]
-
Pagina 17
Pref ace xvii Shell Pr ompts Related Documentation T ABLE P-2 Shell Prompts Shell Prompt C shell machine_name % C shell superuser machine_name # Bourne shell and Korn shell $ Bourne shell and Korn shell superuser # T ABLE P-3 Related Documentation Application Title or Description Adapter installation, removal, and replacement Y our system’s: • [...]
-
Pagina 18
xviii Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000 Accessing Sun Documentation Online The docs.sun.com sm web site enables you to access Solaris technical documentation on the W eb. Y ou can browse the docs.sun.com archive or sear ch for a specific book title or subject at: http://docs.sun.com Documentat[...]
-
Pagina 19
1 CHAPTER 1 Overview of the Sun Quad FastEthernet 6U CompactPCI Adapter This chapter contains an overview of the Sun Quad FastEthernet 6U CompactPCI adapter, including: ■ “Product Description” on page 2 ■ “Features” on page 3 ■ “Overview of the Installation Procedure” on page 4[...]
-
Pagina 20
2 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Pr oduct Description The Sun Quad FastEthernet 6U CompactPCI adapter contains four fully buffered twisted-pair Ethernet ports (RJ-45), providing four switchable 10BASE-T/ 100BASE-TX channels, on a CompactPCI adapter . The adapter is available for front- a[...]
-
Pagina 21
Chapter 1 Overview of the Sun Quad F astEthernet 6U CompactPCI Adapter 3 FIGURE 1-2 Sun Quad FastEthernet 6U CompactPCI Adapter (Fr ont-Access V ersion) Caution – Do not attempt to use the rear -access adapter ’s rear transition car d ( FIGURE 1- 1 ) with the front-access adapter ( FIGURE 1-2 ). Using this combination is not supported and may d[...]
-
Pagina 22
4 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Overview of the Installation Pr ocedur e This section presents an overview of the terminology and lists the major tasks you will perform when installing the adapter into your system. Because of the complexity of the networking environment, your specific i[...]
-
Pagina 23
Chapter 1 Overview of the Sun Quad F astEthernet 6U CompactPCI Adapter 5 CompactPCI platform without affecting the other functions of the platform. The standard also def ines state transitions for the hardware and softwar e connection processes that allow the car d to be connected and configured. The adapter supports two models of hot swap: ■ Bas[...]
-
Pagina 24
6 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Installing the Fr ont-Access Adapter The following table lists the main procedures you will perform when you install and configur e the front-access adapter ( FIGURE 1-2 ). T ABLE 1-2 Front-Access Installation Overview T ask Chapter or Section Documented [...]
-
Pagina 25
7 CHAPTER 2 Installing the Rear -Access Adapter This chapter describes how to install the rear -access version of the Sun Quad FastEthernet 6U CompactPCI adapter in a hot-swap-compatible server . The rear -access version of the adapter is composed of two separate cards: a front card, which contains the hot-swap LED, and a rear transition car d, whi[...]
-
Pagina 26
8 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Pr eparing for the Installation Before installing the adapter , prepare for the installation by assembling the appropriate tools, unpacking the ship kit, selecting a CompactPCI slot, and determining a mode of installation. T ools and Equipment Needed Y ou[...]
-
Pagina 27
Chapter 2 Installing the Rear-Access Adapter 9 Selecting a CompactPCI Slot Pair in the System The rear -access version of the adapter is exclusively designed to be installed in a rear -accessible 6U system. Y ou must first install the rear transition car d in a rear CompactPCI slot of the server , and then you can install the front car d in the ass[...]
-
Pagina 28
10 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Determining the Installation T ype Y ou can install the adapter in the system in either a hot-swap mode or in a cold- swap mode. (See “Installation Methods” on page 4 for more information.) ■ Hot swap—see “Installing the Rear-Access Adapter in [...]
-
Pagina 29
Chapter 2 Installing the Rear-Access Adapter 11 ▼ T o Install the Rear T ransition Car d Install the rear transition car d in the rear CompactPCI slot that you selected in “Selecting a CompactPCI Slot Pair in the System” on page 9. 1. Retrieve the wrist strap from the adapter ’ s ship kit. 2. Attach the adhesive copper strip of the antistat[...]
-
Pagina 30
12 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 5. W ith the card resting on the mat, press the levers outward to open the ejection levers. The card may contain dif ferent types of ejection levers. For example, FIGURE 2-3 shows two possible types of levers. The levers may also contain a locking mechan[...]
-
Pagina 31
Chapter 2 Installing the Rear-Access Adapter 13 FIGURE 2-4 Aligning the Rear T ransition Card W ith the CompactPCI Slot Card Guide 7. Push the card all the way in the slot until the two ejection levers move inward. The tabs of the ejection levers (see FIGURE 2-5 ) should fit smoothly into the rectangular cutouts in the top and bottom of the slot. F[...]
-
Pagina 32
14 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 8. Close the ejection levers by pushing the levers in toward the card. The card may contain dif ferent types of ejection levers. For example, FIGURE 2-6 shows two possible types of levers. The levers may also contain a locking mechanism that will lock wh[...]
-
Pagina 33
Chapter 2 Installing the Rear-Access Adapter 15 FIGURE 2-7 Ejection Levers Installed in the Slot’s Cutouts (T wo T ypes of Levers) 9. Using a No. 0 Phillips screwdriver , tighten the captive screws inside the card’ s top and bottom ejection levers. The card may contain dif ferent types of ejection levers. For example, FIGURE 2-8 shows two possi[...]
-
Pagina 34
16 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 ▼ T o Install the Rear -Access Front Car d After installing the rear transition card, you can install the fr ont card. The fr ont card is hot-swap aware, which means the system will r ecognize the card during the installation. 1. W alk to the front of [...]
-
Pagina 35
Chapter 2 Installing the Rear-Access Adapter 17 Before installing the car d in the system, you will need to open the card’s ejection levers (see FIGURE 2-9 ). FIGURE 2-9 Location of the Fr ont Card’s Ejection Levers 6. W ith the card resting on the on the mat, press the levers outward to open the ejection levers. The card may contain dif ferent[...]
-
Pagina 36
18 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 7. Lift up the card, and keeping it perfectly vertical, carefully slide the card into the selected slot. Be sure to align the top and bottom of the car d into the slot’s card guides ( FIGURE 2-10 ). Also, make sure the ejection levers r emain open whil[...]
-
Pagina 37
Chapter 2 Installing the Rear-Access Adapter 19 10. Locate the hot-swap LED on the front card to determine if the card has been activated and is attached to the system (see FIGURE 2-1 1 ). FIGURE 2-11 Location of the Rear -Access Adapter ’s Hot-Swap LED on the Front Card The hot-swap LED shows whether the adapter has been activated. ■ If the ho[...]
-
Pagina 38
20 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 12. Log in to the server . Refer to the server ’s documentation for the procedure. 13. At the terminal prompt, type the hot-swap software commands to identify and attach the adapter to the server . These commands may be specific to the server . Refer t[...]
-
Pagina 39
Chapter 2 Installing the Rear-Access Adapter 21 16. Remove the wrist strap from the chassis and from your wrist. See “Connecting the Cables to the Rear T ransition Card” on page 26 for instructions on connecting the cables to the rear transition card. Installing the Rear -Access Adapter in Cold-Swap Mode Note – When installing the adapter in [...]
-
Pagina 40
22 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 2. Follow the appropriate procedures, as documented in the system’ s service manual, to shut down and power off the server . Refer to the system’s documentation for the complete power off procedur e. For example, if you installed the adapter in a Net[...]
-
Pagina 41
Chapter 2 Installing the Rear-Access Adapter 23 6. Lift up the card, and keeping it perfectly vertical, carefully slide the card into the selected rear slot. Be sure to align the top and bottom of the car d into the slot’s card guides ( FIGURE 2-4 ). Also, make sure the ejection levers r emain open while you slide the card into the slot. 7. Push [...]
-
Pagina 42
24 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 4. If the front slot contains a factory-installed f iller panel, remove the f iller panel before installing the card. Refer to the system’s documentation for instructions on how to remove the filler panel. T ypically , you will need to loosen the fille[...]
-
Pagina 43
Chapter 2 Installing the Rear-Access Adapter 25 ▼ T o Power On the Server This procedur e describes a general overview for powering on the server . Refer to your server ’s documentation for the exact procedure. 1. Before powering on the server , make sure that all any peripheral devices connected to the server are powered on. 2. Follow the appr[...]
-
Pagina 44
26 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Connecting the Cables to the Rear T ransition Car d After installing the adapter in the system, you can attach the Ethernet cables to the Ethernet ports on the rear transition car d. ▼ T o Connect the Cables to the Rear Ethernet Ports 1. Locate the ada[...]
-
Pagina 45
27 CHAPTER 3 Installing the Fr ont-Access Adapter This chapter describes how to install the front-access version of the Sun Quad FastEthernet 6U CompactPCI adapter in a CompactPCI hot-swap-compatible server . The front-access version of the Sun Quad FastEthernet 6U CompactPCI adapter contains a hot-swap LED, four Ethernet ports, and link LEDs. This[...]
-
Pagina 46
28 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Pr eparing for the Installation Before installing the adapter , prepare for the installation by assembling the appropriate tools, unpacking the ship kit, selecting a CompactPCI slot, and determining a mode of installation. T ools and Equipment Needed Y o[...]
-
Pagina 47
Chapter 3 Installing the Front-Access Adapter 29 Determining the Installation T ype Y ou can install the adapter in the system in either a hot-swap mode or in a cold- swap mode. (See “Installation Methods” on page 4 for more information.) ■ Hot swap—see “Installing the Front-Access Adapter in Hot-Swap Mode” on page 29 for the procedur e[...]
-
Pagina 48
30 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 4. If the slot contains a factory-installed f iller panel, remove the f iller panel before installing the adapter . Refer to the system’s documentation for instructions on how to remove the filler panel. T ypically , you will need to loosen the filler [...]
-
Pagina 49
Chapter 3 Installing the Front-Access Adapter 31 FIGURE 3-2 Opening the Ejection Levers (T wo T ypes of Levers) 7. Lift up the adapter , and keeping it perfectly vertical, carefully slide the adapter into the selected slot. Be sure to align the top and bottom of the adapter into the slot’s car d guides ( FIGURE 3-3 ). Also, make sure the ejection[...]
-
Pagina 50
32 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 8. Push the adapter all the way into the slot until the two ejection levers move inward. The tabs of the ejection levers (see FIGURE 3-4 ) should fit smoothly into the rectangular cutouts in the top and bottom of the slot. FIGURE 3-4 Location of the Ejec[...]
-
Pagina 51
Chapter 3 Installing the Front-Access Adapter 33 When installed correctly , the ejection lever tabs will fit smoothly into the r ectangular cutouts in the top and bottom of the slot ( FIGURE 3-6 ). FIGURE 3-6 Ejection Lever T abs Installed in the Slot’s Cutouts (T wo T ypes of Levers) 10. Locate the hot-swap LED on the adapter to determine if the[...]
-
Pagina 52
34 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 The hot-swap LED shows whether the adapter has been activated. ■ If the hot-swap LED is OFF (unlit), the I/O slots in the server have been set to full hot swap and the adapter has been activated. Go to Step 15. ■ If the hot-swap LED is ON, then the I[...]
-
Pagina 53
Chapter 3 Installing the Front-Access Adapter 35 For example, if the attachment point ID is pci_pci0:cpci_slot3 (the third CompactPCI slot on the server), you would type: The hot-swap LED should go off, indicating that the adapter has been activated. 14. Reattach the wrist strap to the chassis and to your wrist. 15. Using a No. 0 Phillips screwdriv[...]
-
Pagina 54
36 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Installing the Fr ont-Access Adapter in Cold-Swap Mode Note – When installing the adapter in a server in cold-swap mode, you must consult the documentation that shipped with the server . The server ’s documentation describes the specific softwar e co[...]
-
Pagina 55
Chapter 3 Installing the Front-Access Adapter 37 3. V erify that the system’ s power LED is off (unlit), indicating that the system is completely powered off. Refer to the system’s documentation for the location of the power LED. For example, on a Netra ct server , the power LED is on the front panel. Once the system has been shut down and powe[...]
-
Pagina 56
38 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 8. Push the adapter all the way into the slot until the two ejection levers move inward. The tabs of the ejection levers (see FIGURE 3-4 ) should fit smoothly in the rectangular cutouts in the top and bottom of the slot. 9. Close the ejection levers by p[...]
-
Pagina 57
Chapter 3 Installing the Front-Access Adapter 39 3. During the power on sequence, watch the hot-swap LED on the adapter ( FIGURE 3-7 ). ■ The LED should blink quickly and then stay off if the adapter was installed correctly . ■ If the hot-swap LED remains on (lit), the adapter was not installed correctly . The adapter may not be seated correctl[...]
-
Pagina 58
40 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Connecting the Cables to the Fr ont-Access Adapter After installing the adapter , you can attach the Ethernet cables to the adapter ’s connectors. ▼ T o Connect the Cables to the Fr ont-Access Ethernet Ports 1. Locate the adapter that you installed i[...]
-
Pagina 59
41 CHAPTER 4 Conf iguring the Network Software This chapter describes how to configur e the network software files associated with the Sun Quad FastEthernet 6U CompactPCI adapter. This chapter also contains additional software and f irmware procedur es that may be needed when configuring the adapter . This chapter contains the following sections: ?[...]
-
Pagina 60
42 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Attaching the Sun Quad FastEthernet Interfaces to the Network The adapter ’s four FastEthernet network interfaces are controlled by the Sun Quad FastEthernet qfe (1M) device driver . In order to use the adapter ’s qfe interfaces, you must use the Sol[...]
-
Pagina 61
Chapter 4 Configur ing the Networ k Software 43 In the preceding example, the four SUNW,qfe instances are fr om a Sun Quad FastEthernet 6U CompactPCI adapter. The path_to_inst file contains the full device path names to the four SUNW,qfe instances, the instance numbers (shown in bold type), and the driver names ( qfe ). Refer to the path_to_inst (4[...]
-
Pagina 62
44 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Using the instance examples in Step 2, the following example shows the four /etc/hostname.qfe instance files r equired for a system called zardoz , which has a Sun Quad FastEthernet 6U CompactPCI adapter ( zardoz-11 , zardoz-12 , zardoz-13 , and zardoz-1[...]
-
Pagina 63
Chapter 4 Configur ing the Networ k Software 45 5. Activate the new qfe interfaces using the ifconfig command. For each adapter interface, type the following at the command line, replacing instance with the interface’s instance number and ip_address with the interface’s IP address: For example, if you wanted to activate all of the sample qfe in[...]
-
Pagina 64
46 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 If the adapter is connected to a link partner with which the autonegotiation protocol fails to operate successfully , you can conf igure the device not to use this protocol and force the driver to set up the link in the mode and speed of your choice. See[...]
-
Pagina 65
Chapter 4 Configur ing the Networ k Software 47 2. At a terminal prompt, type the following command to set the property to true: 3. Use the ifconfig command to stop all network activity travelling over the adapter ’ s Ethernet interfaces. For example, if you were using the adapter ’s four interfaces, and they were named qfe0 , qfe1 , qfe2 , and[...]
-
Pagina 66
48 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 6. Use the ifconfig command to activate the adapter ’ s Ethernet interfaces. For each adapter interface, type the following at the command line, replacing instance with the interface’s instance number and ip_address with the interface’s IP address:[...]
-
Pagina 67
Chapter 4 Configur ing the Networ k Software 49 3. At the ok prompt, type show-nets to list the network devices on your system. Y ou should see the full path name of the qfe devices, similar to the following example: 4. Select the qfe device that you want to use as a boot device. Using the show-nets command, select the letter of the device you wish[...]
-
Pagina 68
50 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000[...]
-
Pagina 69
51 APPENDIX A Specif ications This appendix defines the connector pin descriptions and lists the specif ications for the rear - and front-access versions of the Sun Quad FastEthernet 6U CompactPCI adapter. This appendix contains the following sections: ■ “Ethernet Port Locations and Descriptions” on page 52 ■ “Operation Specif ications”[...]
-
Pagina 70
52 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Ethernet Port Locations and Descriptions FIGURE A-1 shows the four Ethernet port connectors of both the rear-access and front-access versions of the Sun Quad FastEthernet 6U CompactPCI adapter. T ABLE A-1 lists the pin descriptions for the four RJ-45 Eth[...]
-
Pagina 71
Appendix A Specifications 53 Operation Specif ications T ABLE A-1 Pin Descriptions for the Four 8-Pin RJ-45 Connectors (Ports 0 to 3) Description P ort 0 P ort 1 P ort 2 P ort 3 Not Used 1 1 1 1 Not Used 2 2 2 2 TD+ 3 3 3 3 Not Used 4 4 4 4 TD– 5 5 5 5 RD+ 6 6 6 6 RD– 7 7 7 7 Not Used 8 8 8 8 T ABLE A-2 Operation Specifications Specification Pe[...]
-
Pagina 72
54 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Physical Dimensions Physical Dimensions of the Rear -Access Adapter T ABLE A-3 Physical Dimensions (Rear-Access) Dimension Measurement Front card: Length 233.35 mm (9.19 in.) W idth 160 mm (6.3 in.) Height Primary component side Meets the CompactPCI spec[...]
-
Pagina 73
Appendix A Specifications 55 Physical Dimensions of the Fr ont-Access Adapter Envir onmental Specif ications T ABLE A-4 Physical Dimensions (Front-Access) Dimension Measurement Length (with the card guide) 233.35 mm (9.19 in.) Length (without the card guide) 100.00 mm (3.94 in.) W idth 160 mm (6.3 in.) Height Primary component side Meets the Compac[...]
-
Pagina 74
56 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Power Requir ements T ABLE A-6 Power Requirements Specification Measurement Maximum power dissipation 14 watts Maximum power consumption 2.8 amps @ 5V V oltage tolerance 5V +/- 5% Ripple Maximum 100 mV Operational current 5V , 2.0 amps[...]
-
Pagina 75
57 APPENDIX B Conf iguring the Sun Quad FastEthernet Device Driver Parameters The qfe (1M) device driver controls the four Sun Quad FastEthernet 6U CompactPCI adapter SUNW,qfe Ethernet devices. Y ou can manually set the qfe device driver parameters to customize each SUNW,qfe device in your system. This appendix lists the available qfe device driver[...]
-
Pagina 76
58 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Sun Quad FastEthernet Device Driver Parameters This section describes the hardware overview of the local transceiver used in the adapter and defines the qfe device driver parameters. Har dware Overview The four SUNW,qfe channels each provide 10BASE-T or [...]
-
Pagina 77
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 59 Device Driver Parameter V alues and Def initions T ABLE B-1 lists the qfe device driver parameters. T ABLE B-1 qfe Driver Parameters, Status, and Descriptions Parameter Status Description transceiver_inuse Read only Defines the curr ent status link_status Read only Defi[...]
-
Pagina 78
60 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Parameters that Def ine the Curr ent Status The read-only parameters described in T ABLE B-2 explain the operational mode of the interface. The following parameters display the current status of an interface. Interpacket Gap Parameters The adapter ’s P[...]
-
Pagina 79
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 61 If your network has systems that use longer IPG (the sum of ipg1 and ipg2 ), and if those systems seem to be slow when accessing the network, increase the values of ipg1 and ipg2 to match the longer IPGs of the other systems. Def ining an Additional Delay Befor e T rans[...]
-
Pagina 80
62 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Operational Mode Parameters T ABLE B-5 describes the operational mode parameters and their default values. Note – The priority (in descending order) for these parameters is: adv_100fdx_cap , adv_100T4_cap , adv_100hdx_cap , adv_10fdx_cap , and adv_10hd[...]
-
Pagina 81
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 63 Def ining the Number of Back-to-Back Packets to T ransmit The pace_size parameter (see T ABLE B-6 ) defines the maximum number of back-to- back packets you can transmit at one time. If the value is zero, ther e will be no limit to the number of back-to-back packets that[...]
-
Pagina 82
64 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Parameters That Report the Link Partner Capabilities T ABLE B-8 describes the read-only link partner capabilities. If the link partner is not capable of autonegotiation (when lp_autoneg_cap is 0) the information described in T ABLE B-8 is not relevant an[...]
-
Pagina 83
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 65 Setting the qfe Device Driver Parameters This section describes how to set the qfe device driver parameters in three ways: ■ Using the ndd utility ■ Using the qfe.conf file T o set device driver parameters dynamically while the system is running, use the ndd utility[...]
-
Pagina 84
66 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 ▼ T o Specify the Device Instance for the ndd Utility 1. Check the /etc/path_to_inst f ile to identify the instance number associated with a particular SUNW,qfe device. For example: In the preceding example, the four SUNW,qfe@ x ,1 instances are fr om [...]
-
Pagina 85
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 67 Using the ndd Utility in Noninteractive Mode This section describes how to modify a parameter value and how to display a parameter value using the ndd utility in noninteractive mode. ● T o modify a parameter value, use the -set option. If you invoke the ndd utility wi[...]
-
Pagina 86
68 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 ● T o list all the parameters supported by the qfe driver , type ndd /dev/qfe ? at a terminal prompt. # ndd /dev/qfe ? ? (read only) transceiver_inuse (read only) link_status (read only) link_speed (read only) link_mode (read only) ipg1 (read and wri[...]
-
Pagina 87
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 69 Using the ndd Utility in Interactive Mode ● T o modify a parameter value in interactive mode, start the utility as shown below . The ndd utility prompts for the name of a parameter: After you type the parameter name, the ndd utility prompts for the parameter value. Fo[...]
-
Pagina 88
70 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Setting Forced Mode Using the ndd Utility This section describes how to force a network speed over an interface (forced mode) and to disable autonegotiation. ▼ T o Set Forced Mode and Disable Autonegotiation 1. Use the ndd utility to select the qfe ins[...]
-
Pagina 89
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 71 T o Enable Autonegotiation Using the ndd Utility This section describes how to set at least one of the four operational modes and enable autonegotiation. See “Autonegotiation Protocol” on page 45 for more information about the autonegotiation and operational modes. [...]
-
Pagina 90
72 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Setting Parameters Using the qfe.conf File T o set the qfe driver parameters for qfe devices so that the parameter variables stay in effect after r ebooting the system, create a qfe.conf file in your system’s /kernel/drv directory . Y ou can also creat[...]
-
Pagina 91
Appendix B Configur ing the Sun Quad FastEthernet De vice Driver P arameters 73 ▼ T o Set Driver Parameters By Cr eating a qfe.conf File 1. Log in to the system. Refer to the server ’s documentation for the procedure. 2. Obtain the hardware path names for the qfe devices in the device tree. The path names and the associated instance numbers are[...]
-
Pagina 92
74 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 In the third line of the pr evious example: ■ Name = SUNW,qfe ■ Parent = /pci@1f,0/pci@1/pci@1/pci@a ■ Unit-address = 2,1 In the fourth line of the previous example: ■ Name = SUNW,qfe ■ Parent = /pci@1f,0/pci@1/pci@1/pci@a ■ Unit-address = 3,[...]
-
Pagina 93
75 APPENDIX C Removing and Replacing the Adapter This appendix describes how to disable the adapter ’s qfe interfaces prior to removing the adapter fr om a system, and how to activate the interfaces after replacing the adapter . This appendix contains the following sections: ■ “Disabling the Network Interfaces and Removing the Adapter” on p[...]
-
Pagina 94
76 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Disabling the Network Interfaces and Removing the Adapter This procedur e describes how to disable the adapter ’s qfe interfaces before removing the adapter fr om a hot-swap server . This procedure also lists cautions that must be read befor e removing[...]
-
Pagina 95
Appendix C Removing and Replacing the Adapter 77 3. Remove the adapter from the system as documented in the system’ s service manual. Caution – Yo u must follow the instructions outlined in your system’s service manual for the removal of network interface I/O cards. If you do not follow the procedur es in the service manual, you may cause you[...]
-
Pagina 96
78 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Replacing the Adapter and Activating the Network Interfaces This procedur e describes how to activate the qfe interfaces after replacing the adapter into the system. ▼ T o Replace the Adapter and Activate the Network Interfaces 1. Replace the adapter a[...]
-
Pagina 97
79 APPENDIX D T esting the Adapter This appendix describes how to test the adapter using either the SunVTS diagnostic application or the onboard FCode self-test. This appendix contains the following sections: ■ “Using the SunVTS Diagnostic Software” on page 80 ■ “Using the OpenBoot PROM FCode Self-T est” on page 81[...]
-
Pagina 98
80 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 Using the SunVTS Diagnostic Softwar e The SunVTS software executes multiple diagnostic hardwar e tests from a single user interface. It is used to verify the configuration and functionality of most har dware controllers and devices. The SunVTS software o[...]
-
Pagina 99
Appendix D T esting the Adapter 81 Using the OpenBoot PROM FCode Self-T est The Sun Quad FastEthernet adapter ’s self-test verifies the correct operation of the adapter and identifies any har dware pr oblems with the adapter . The self-test is a suite of tests that reside in the adapter ’s FCode PROM. Y ou can only invoke the FCode self-test di[...]
-
Pagina 100
82 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 4. Set the diag-switch? parameter to true to see the diagnostic power-on self-test (POST) messages. 5. Reset the system to activate these parameter changes. 6. Use the show-nets command to display the list of network devices on the system. Among the list[...]
-
Pagina 101
Appendix D T esting the Adapter 83 The following tests are run when you execute the test command: ■ HME register ■ MAC internal loopback ■ 100 Mbps PHY loopback ■ 10 Mbps PHY loopback Note – T o test all of the interfaces of the adapter , you will need to execute the test command separately for each SUNW,qfe interface. If all of the tests[...]
-
Pagina 102
84 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 9. Reset and reboot the system. Refer to the system’s documentation for the correct procedur es for bringing up the system. ok reset-all[...]
-
Pagina 103
Inde x 85 Index A activating network interfaces, 78 autonegotiation, 45, 64, 71 B booting over a qfe network, 48 C cabling front-access adapter, 40 rear -access adapter, 2 6 cold swap defined, 4, 7 , 27 front-access adapter installation, 36 powering off the server, 21, 3 6 powering on the server, 25 , 3 8 rear -access adapter installation, 2 1 D d[...]
-
Pagina 104
86 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 overview of installation, 6 powering off the server, 38 preparing for installation, 8, 28 removing, 76 replacing, 78 tools needed, 8, 28 full-duplex operation mode, 45, 62 H half-duplex operation mode, 45, 62 hardwar e ASIC description, 58 cabling, 26 , [...]
-
Pagina 105
Inde x 87 ok prompt, 48, 8 1 test command, 82 viewing device path names, 43 , 49 operation mode full-duplex, 45 half-duplex, 45 operation specifications, 53 P path_to_inst file, 42, 66, 73 PCI FastEthernet and expansion ASIC, 58, 60, 61 physical dimensions, 54 plumbing interfaces, 48, 78 power requir ements, 56 powering off the server, 21, 36 power[...]
-
Pagina 106
88 Sun Quad F astEther net 6U CompactPCI Adapter Installation and User’ s Guide • June 2000 SUNW,qfe devices, 42, 49, 57, 65, 82 T test diagnostic command, 81 testing, 79 to 84 tools requir ed for installation, 8, 28 U unplumbing interfaces, 47, 76[...]