Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Sun Microsystems T3 manuale d’uso - BKManuals

Sun Microsystems T3 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Sun Microsystems T3. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Sun Microsystems T3 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Sun Microsystems T3 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Sun Microsystems T3 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Sun Microsystems T3
- nome del fabbricante e anno di fabbricazione Sun Microsystems T3
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Sun Microsystems T3
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Sun Microsystems T3 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Sun Microsystems T3 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Sun Microsystems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Sun Microsystems T3, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Sun Microsystems T3, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Sun Microsystems T3. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    Sun Microsystems, Inc. 901 San Antonio Road P alo Alto , CA 94303-4900 U .S.A. 650-960-1300 Send comments about this document to: docfeedback@sun.com Sun StorEdge ™ T3 and T3+ Arra y Configuration Guide P ar t No . 816-0777-10 August 2001 , Re vision A[...]

  • Pagina 2

    Please Recycle Copyright 2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 U.S.A. All rights r eserved. This product or document is distributed under licenses r estricting its use, copying, distribution, and decompilation. No part of this product or document may be repr oduced in any form by any means without prior written[...]

  • Pagina 3

    iii Contents Preface ix 1. Array Conf iguration Overview 1 Product Description 1 Controller Car d 2 Interconnect Car ds 4 Array Configurations 6 Configuration Guidelines and Restrictions 8 Configuration Recommendations 9 Supported Platforms 9 Supported Software 10 Sun Cluster Support 10 2. Conf iguring Global Parameters 13 Cache 13 Configuring Cach[...]

  • Pagina 4

    iv Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Logical Volumes 16 Guidelines for Configuring Logical V olumes 17 Determining How Many Logical V olumes Y ou Need 17 Determining Which RAID Level Y ou Need 18 Determining Whether Y ou Need a Hot Spare 18 Creating and Labeling a Logical V olume 19 Setting the LUN Reconstruction Rat[...]

  • Pagina 5

    Contents v Single Host W ith T wo Hubs and Eight Controller Units Configur ed as Four Partner Groups 36 Dual Hosts W ith T wo Hubs and Four Controller Units 38 Dual Hosts W ith T wo Hubs and Eight Controller Units 40 Dual Hosts W ith T wo Hubs and Four Controller Units Configur ed as T wo Partner Groups 42 Dual Hosts W ith T wo Hubs and Eight Contr[...]

  • Pagina 6

    vi Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Administration Path 60 Connecting Partner Groups 60 Workgroup Configurations 62 Enterprise Configurations 63 Glossary 65[...]

  • Pagina 7

    vii Figur es FIGURE 1-1 Sun StorEdge T3 Array Controller Card and Ports 3 FIGURE 1-2 Sun StorEdge T3+ Array Controller Card and Ports 4 FIGURE 1-3 Interconnect Card and Ports 5 FIGURE 1-4 Workgroup Configuration 6 FIGURE 1-5 Enterprise Configuration 7 FIGURE 3-1 Sun StorEdge T3 Array Partner Group 24 FIGURE 4-1 Single Host Connected to One Controll[...]

  • Pagina 8

    viii Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 FIGURE 5-1 Sun Enterprise 6 x 00/5 x 00/4 x 00/3 x 00 SBus+ I/O Board 52 FIGURE 5-2 Sun StorEdge PCI FC-100 Host Bus Adapter 53 FIGURE 5-3 Sun StorEdge SBus FC-100 Host Bus Adapter 54 FIGURE 5-4 Sun StorEdge PCI Single Fibre Channel Network Adapter 55 FIGURE 5-5 Sun StorEdge PCI[...]

  • Pagina 9

    ix Pr eface The Sun StorEdge T3 and T3+ Array Configuration Guide describes the r ecommended configurations for Sun StorEdge T3 and T3+ arrays for high availability , maximum performance, and maximum storage capability . This guide is intended for Sun™ field sales and technical support personnel. Befor e Y ou Read This Book Read the Sun StorEdge [...]

  • Pagina 10

    x Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Using UNIX Commands This document contains some information on basic UNIX ® commands and procedur es such as booting the devices. For further information, see one or more of the following: ■ AnswerBook2™ online documentation for the Solaris™ software environment ■ Other so[...]

  • Pagina 11

    Preface xi Shell Pr ompts Related Documentation Shell Prompt C shell machine_name % C shell superuser machine_name # Bourne shell and Korn shell $ Bourne shell and Korn shell superuser # Sun StorEdge T3 and T3+ array :/: Application Title Part Number Latest array updates Sun StorEdge T3 and T3+ Array Release Notes 816-1983 Installation overview Sun[...]

  • Pagina 12

    xii Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Accessing Sun Documentation Online Y ou can find the Sun StorEdge T3 and T3+ array documentation and other select product documentation for Network Storage Solutions at: http://www.sun.com/products-n-solutions/hardware/docs/ Network_Storage_Solutions Sun W elcomes Y our Comments [...]

  • Pagina 13

    1 CHAPTER 1 Array Conf iguration Overview This chapter describes the Sun StorEdge T3 and T3+ arrays, the connection ports, and Fibre Channel connections. It also describes basic rules and r ecommendations for configuring the array, and it lists supported hardwar e and software platforms. Note – For installation and cabling information, refer to t[...]

  • Pagina 14

    2 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 The array can be used either as a standalone storage unit or as a building block, interconnected with other arrays of the same type and conf igured in various ways to provide a storage solution optimized to the host application. The array can be placed on a table top or rackmounte[...]

  • Pagina 15

    Chapter 1 Array Configuration Ov er view 3 FIGURE 1-1 Sun StorEdge T3 Array Contr oller Card and Ports The Sun StorEdge T3+ array controller card contains: ■ One Fibre Channel-Arbitrated Loop (FC-AL) port using an LC small-form factor (SFF) connector . The fiber -optic cable that provides data channel connectivity to the array has an LC-SFF conne[...]

  • Pagina 16

    4 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 FIGURE 1-2 Sun StorEdge T3+ Array Contr oller Card and Ports Inter connect Cards The interconnect car ds are alike on both array models. There ar e two interconnect ports on each card: one input and one output for interconnecting multiple arrays. The interconnect car d provides sw[...]

  • Pagina 17

    Chapter 1 Array Configuration Ov er view 5 FIGURE 1-3 Inter connect Card and Ports Interconnect cards Input Output[...]

  • Pagina 18

    6 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Array Conf igurations Each array uses Fibre Channel-Arbitrated Loop (FC-AL) connections to connect to the application host. An FC-AL connection is a 100-Mbyte/second serial channel that enables multiple devices, such as disk drives and controllers, to be connected. T wo array conf[...]

  • Pagina 19

    Chapter 1 Array Configuration Ov er view 7 FIGURE 1-5 Enterprise Conf iguration Note – Sun StorEdge T3 array workgroup and enterprise configurations r equire a media-interface adapter (MIA) connected to the Fibre Channel port to connect the fiber -optic cable. Sun StorEdge T3+ array configurations support direct FC-AL connections. Refer to the Su[...]

  • Pagina 20

    8 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Conf iguration Guidelines and Restrictions W orkgroup Configurations: ■ The media access control (MAC) addr ess is required to assign an IP addr ess to the controller unit. The MAC addr ess uniquely identifies each node of a network. The MAC address is available on the pull-out [...]

  • Pagina 21

    Chapter 1 Array Configuration Ov er view 9 Conf iguration Recommendations ■ Use enterprise configurations for controller r edundancy . ■ Use host-based software such as VERIT AS V olume Manager (VxVM), Sun Enterprise™ Server Alternate Pathing (AP) software, or Sun StorEdge T raffic Manager for multipathing support. ■ Connect redundant paths[...]

  • Pagina 22

    10 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Supported Softwar e The following software is supported on Sun StorEdge T3 and T3+ arrays: ■ Solaris 2.6, Solaris 7, and Solaris 8 operating environments ■ VERIT AS V olume Manager 3.04 and later with DMP ■ Sun Enterprise Server Alternate Pathing (AP) 2.3.1 ■ Sun StorEdge[...]

  • Pagina 23

    Chapter 1 Array Configuration Ov er view 11 ■ Switches are not supported. ■ Hubs must be used. ■ The Sun StorEdge SBus FC-100 (SOC+) HBA and the onboard SOC+ interface in Sun Fire™ systems ar e supported. ■ On Sun Enterprise 6 x 00/5 x 00/4 x 00/3 x 00 systems, a maximum of 64 arrays are supported per cluster . ■ On Sun Enterprise 10000[...]

  • Pagina 24

    12 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001[...]

  • Pagina 25

    13 CHAPTER 2 Conf iguring Global Parameters When an array is shipped, the global parameters are set to default values. This chapter describes how to reconfigur e your array by changing these default values. Caution – If you are planning an enterprise configuration using new factory units, be sure to install and set up the units as a partner group[...]

  • Pagina 26

    14 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Conf iguring Cache for Performance and Redundancy Cache mode can be set to the following values: ■ Auto . The cache mode is determined as either write-behind or write-through, based on the I/O prof ile. If the array has full redundancy available, then caching operates in write-[...]

  • Pagina 27

    Chapter 2 Configur ing Global P arameters 15 Conf iguring Data Block Size The data block size is the amount of data written to each drive when striping data across drives. (The block size is also known as the stripe unit size.) The block size can be changed only when there are no volumes def ined. The block size can be configur ed as 16 Kbytes, 32 [...]

  • Pagina 28

    16 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Note – The data block size must be configured befor e any logical volumes are created on the units. Remember , this block size is used for every logical volume created on the unit. Ther efore it is important to have similar application data configur ed per unit. Data block size[...]

  • Pagina 29

    Chapter 2 Configur ing Global P arameters 17 Note – Individual physical disk drives are not visible from the application host. Refer to the Sun StorEdge T3 and T3+ Array Administrator ’ s Guide for more information on creating logical volumes. Guidelines for Conf iguring Logical V olumes Use the following guidelines when configuring logical vol[...]

  • Pagina 30

    18 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 ■ Data-intensive NFS, version 3 ■ DSS ■ DW ■ HPC Note – If you are cr eating new volumes or changing the volume configuration, you must first manually r ewrite the label of the previous volume using the autoconfigur e option of the format (1M) UNIX host command. For mor[...]

  • Pagina 31

    Chapter 2 Configur ing Global P arameters 19 Note – Only one hot spare is allowed per array and it is only usable for the array in which it is configur ed. The hot spare must be conf igured as drive 9. Drive 9 will be the hot spare in the unit. So, for example, should a drive failure occur on drive 7, drive 9 is synchronized automatically with th[...]

  • Pagina 32

    20 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 If the volume has a hot spare conf igured and that drive is available, the data on the disabled drive is reconstructed on the hot-spar e drive. When this operation is complete, the volume is operating with full redundancy protection, so another drive in the volume may fail withou[...]

  • Pagina 33

    Chapter 2 Configur ing Global P arameters 21 ■ Second, you can use third-party softwar e on the host system to create as many partitions as desired fr om a given volume. In the Solaris environment, you can use VERIT AS V olume Manager or Solaris Logical V olume Management (SL VM) formerly known as Solstice DiskSuite (SDS) for this purpose. Note ?[...]

  • Pagina 34

    22 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Conf iguring RAID Levels The Sun StorEdge T3 and T3+ arrays are preconf igured at the factory with a single LUN, RAID level 5 redundancy and no hot spare. Once a volume has been configur ed, you cannot reconfigur e it to change its size, RAID level, or hot spare configuration. Y [...]

  • Pagina 35

    23 CHAPTER 3 Conf iguring Partner Gr oups Sun StorEdge T3 and T3+ arrays can be interconnected in partner groups to form a redundant and lar ger storage system. Note – The terms partner group and enterprise conf iguration refer to the same type of configuration and ar e used interchangeably in this document. Note – Partner groups ar e not suppo[...]

  • Pagina 36

    24 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 FIGURE 3-1 Sun StorEdge T3 Array Partner Gr oup Note – Sun StorEdge T3 arrays require a media-interface adapter (MIA) connected to the Fibre Channel port on the controller car d to connect the fiber -optic cable. Sun StorEdge T3+ array configurations support dir ect FC-AL conne[...]

  • Pagina 37

    Chapter 3 Configur ing P ar tner Groups 25 Any controller unit will boot fr om the master controller unit’s drives. All configuration data, including syslog information, is located on the master controller unit’s drives. How Partner Gr oups W ork If the master controller unit fails and the “heartbeat” between it and the alternate master sto[...]

  • Pagina 38

    26 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Cr eating Partner Gr oups Partner groups can be cr eated in two ways: ■ From new units ■ From existing standalone units Instructions for installing new array units and connecting them to create partner groups can be found in the Sun StorEdge T3 and T3+ Array Installation, Ope[...]

  • Pagina 39

    27 CHAPTER 4 Conf iguration Examples This chapter includes sample reference conf igurations for Sun StorEdge T3 and T3+ arrays. Although there ar e many supported configurations, these refer ence configurations pr ovide the best solution for many installations.: ■ “Direct Host Connection” on page 27 ■ “Hub Host Connection” on page 34 ?[...]

  • Pagina 40

    28 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Single Host W ith One Controller Unit FIGURE 4-1 shows one application host connected through an FC-AL cable to one array controller unit. The Ethernet cable connects the controller to a management host via a LAN on a public or separate network, and requires an IP addr ess. Note [...]

  • Pagina 41

    Chapter 4 Configuration Examples 29 Single Host W ith T wo Contr oller Units Conf igured as a Partner Gr oup FIGURE 4-2 shows one application host connected through FC-AL cables to one array partner group, which consists of two Sun StorEdge T3+ arrays. The Ethernet connection from the master controller unit is on a public or separate network and re[...]

  • Pagina 42

    30 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Host Multipathing Management Softwar e While Sun StorEdge T3 and T3+ arrays are redundant devices that automatically reconf igure whenever a failure occurs on any internal component, a host-based solution is needed for a redundant data path. Supported multipathing solutions inclu[...]

  • Pagina 43

    Chapter 4 Configuration Examples 31 Single Host W ith Four Controller Units Conf igured as T wo Partner Groups FIGURE 4-4 shows one application host connected through FC-AL cables to four arrays configur ed as two separate partner groups. This configuration can be used for capacity and I/O throughput r equirements. Host-based Alternate Pathing soft[...]

  • Pagina 44

    32 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Single Host W ith Eight Controller Units Conf igured as Four Partner Gr oups FIGURE 4-5 shows one application host connected through FC-AL cables to eight Sun StorEdge T3+ arrays, forming four partner groups. This configuration is the maximum allowed in a 72-inch cabinet. This co[...]

  • Pagina 45

    Chapter 4 Configuration Examples 33 FIGURE 4-5 Single Host W ith Eight Controller Units Conf igured as Four Partner Gr oups Application host Management host Ethernet por t LAN Ethernet FC-AL FC-AL HBA HBA HBA HBA HBA HBA HBA HBA Interconnect cables Master Alternate master controller unit controller unit[...]

  • Pagina 46

    34 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Hub Host Connection The following sample configurations are included in this section: ■ “Single Host W ith T wo Hubs and Four Controller Units Conf igured as T wo Partner Groups” on page 34 ■ “Single Host W ith T wo Hubs and Eight Controller Units Conf igured as Four Pa[...]

  • Pagina 47

    Chapter 4 Configuration Examples 35 The following three parameters must be set on the master controller unit, as follows: ■ mp_support = rw or mpxio ■ cache mode = auto ■ cache mirroring = auto Note – For information on setting these parameters, refer to the Sun StorEdge T3 and T3+ Array Administrator ’ s Guide Host-based multipathing sof[...]

  • Pagina 48

    36 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Single Host W ith T wo Hubs and Eight Contr oller Units Conf igured as Four Partner Gr oups FIGURE 4-7 shows one application host connected through FC-AL cables to two hubs and to eight Sun StorEdge T3+ arrays, forming four partner groups. This configuration is the maximum allowe[...]

  • Pagina 49

    Chapter 4 Configuration Examples 37 FIGURE 4-7 Single Host W ith T wo Hubs Configured and Eight Contr oller Units as Four Partner Groups Hub Hub Interconnect cables Application host Ethernet por t Management host FC-AL LAN HBA HBA Ethernet Master Alternate master controller unit controller unit FC-AL[...]

  • Pagina 50

    38 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Dual Hosts W ith T wo Hubs and Four Contr oller Units FIGURE 4-8 shows two application hosts connected through FC-AL cables to two hubs and four Sun StorEdge T3+ arrays. This configuration, also known as a multi-initiator configuration , can be used for footprint and I/O thr ough[...]

  • Pagina 51

    Chapter 4 Configuration Examples 39 FIGURE 4-8 Dual Hosts W ith T wo Hubs and Four Controller Units Hub Hub Application host 1 Ethernet por t LAN FC-AL HBA HBA HBA HBA Application host 2 Management host Ethernet Controller unit[...]

  • Pagina 52

    40 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Dual Hosts W ith T wo Hubs and Eight Contr oller Units FIGURE 4-9 shows two application hosts connected through FC-AL cables to two hubs and eight Sun StorEdge T3+ arrays. This configuration, also known as a multi- initiator configuration , can be used for footprint and I/O thr o[...]

  • Pagina 53

    Chapter 4 Configuration Examples 41 FIGURE 4-9 Dual Hosts W ith T wo Hubs and Eight Controller Units Application host 1 Management Host Ethernet por t LAN FC-AL Hub Hub HBA HBA HBA HBA Application host 2 Ethernet Controller unit[...]

  • Pagina 54

    42 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Dual Hosts W ith T wo Hubs and Four Contr oller Units Conf igured as T wo Partner Groups FIGURE 4-8 shows two application hosts connected through FC-AL cables to two hubs and four Sun StorEdge T3+ arrays forming two partner groups. This multi-initiator configuration can be used f[...]

  • Pagina 55

    Chapter 4 Configuration Examples 43 FIGURE 4-10 Dual Hosts W ith T wo Hubs and Four Controller Units Conf igured as T wo Partner Groups Hub Hub Application host 1 Ethernet por t LAN FC-AL FC-AL HBA HBA HBA HBA Application host 2 Management host Ethernet Master Alternate master controller unit controller unit Interconnect cables[...]

  • Pagina 56

    44 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Dual Hosts W ith T wo Hubs and Eight Contr oller Units Conf igured as Four Partner Gr oups FIGURE 4-9 shows two application hosts connected through FC-AL cables to two hubs and eight Sun StorEdge T3+ arrays forming four partner groups. This multi-initiator configuration can be us[...]

  • Pagina 57

    Chapter 4 Configuration Examples 45 FIGURE 4-11 Dual Hosts W ith T wo Hubs and Eight Controller Units Configur ed as Four Partner Groups Application host 1 Management host Ethernet por t LAN FC-AL FC-AL Hub Hub HBA HBA HBA HBA Application host 2 Ethernet Master Alternate master controller unit controller unit Interconnect cables[...]

  • Pagina 58

    46 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Switch Host Connection This section contains the following example configurations: ■ “Dual Hosts W ith T wo Switches and T wo Controller Units” on page 46 ■ “Dual Hosts W ith T wo Switches and Eight Controller Units” on page 48 Dual Hosts W ith T wo Switches and T wo [...]

  • Pagina 59

    Chapter 4 Configuration Examples 47 FIGURE 4-12 Dual Hosts W ith T wo Switches and T wo Controller Units Application host A Application host B Ethernet por t Management Host LAN Switch Switch FC-AL HBA HBA HBA HBA Ethernet Controller unit[...]

  • Pagina 60

    48 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Dual Hosts W ith T wo Switches and Eight Contr oller Units FIGURE 4-13 shows two application hosts connected through FC-AL cables to two switches and eight Sun StorEdge T3+ arrays. This multi-initiator configuration, can be used for footprint and I/O throughput. Note – This con[...]

  • Pagina 61

    Chapter 4 Configuration Examples 49 FIGURE 4-13 Dual Hosts W ith T wo Switches and Eight Controller Units Application host 1 Application host 2 Ethernet por t Management host LAN Switch Switch FC-AL HBA HBA HBA HBA Ethernet Controller unit[...]

  • Pagina 62

    50 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001[...]

  • Pagina 63

    51 CHAPTER 5 Host Connections This chapter describes the host bus adapters (HBAs) that are supported by Sun StorEdge T3 and T3+ arrays: ■ “Sun Enterprise SBus+ and Graphics+ I/O Boards” on page 52 ■ “Sun StorEdge PCI FC-100 Host Bus Adapter” on page 53 ■ “Sun StorEdge SBus FC-100 Host Bus Adapter” on page 54 ■ “Sun StorEdge PC[...]

  • Pagina 64

    52 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Sun Enterprise SBus+ and Graphics+ I/O Boar ds The SBus+ and Graphics+ I/O boards each pr ovide mounting for two Gigabit Interface Converters (GBICs). For more detailed information about these I/O boar ds, refer to the Sun Enterprise 6x00/5x00/4x00/3x00 Systems SBus+ and Graphics[...]

  • Pagina 65

    Chapter 5 Host Connections 53 Sun StorEdge PCI FC-100 Host Bus Adapter The Sun StorEdge PCI FC-100 host bus adapter is a 33-MHz, 100 Mbytes/second, single-loop Fibre Channel PCI host bus adapter with an onboard GBIC. This host bus adapter is PCI V ersion 2.1-compliant. For more detailed information about this product, r efer to the Sun StorEdge PCI[...]

  • Pagina 66

    54 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Sun StorEdge SBus FC-100 Host Bus Adapter The Sun StorEdge SBus FC-100 host bus adapter is a single-width Fibre Channel SBus card with a Sun Serial Optical Channel (SOC+) ASIC (application-specific integrated circuit). Y ou can connect up to two loops to each card, using hot- plu[...]

  • Pagina 67

    Chapter 5 Host Connections 55 Sun StorEdge PCI Single Fibr e Channel Network Adapter The Sun StorEdge PCI Single Fibre Channel network adapter is a Fibre Channel PCI card with one onboar d optical receiver . This network adapter is PCI V ersion 2.1-compliant. For more detailed information about this product, refer to the Sun StorEdge PCI Single Fib[...]

  • Pagina 68

    56 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 Sun StorEdge PCI Dual Fibr e Channel Network Adapter The Sun StorEdge PCI Dual Fibre Channel network adapter is a Fibre Channel PCI card with two onboar d optical transceivers. This network adapter is PCI V ersion 2.1-compliant. For more detailed information about this pr oduct, [...]

  • Pagina 69

    Chapter 5 Host Connections 57 Sun StorEdge CompactPCI Dual Fibr e Channel Network Adapter The Sun StorEdge CompactPCI Dual Fibre Channel network adapter has two 1-Gbit Fibre Channel ports on a cPCI card. For mor e detailed information about this product, r efer to the Sun StorEdge CompactPCI Dual Fibre Channel Network Adapter Installation Guide , p[...]

  • Pagina 70

    58 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001[...]

  • Pagina 71

    59 CHAPTER 6 Array Cabling This chapter describes the array configurations supported by the Sun StorEdge T3 and T3+ arrays, and it includes the following sections: ■ “Overview of Array Cabling” on page 59 ■ “W orkgroup Configurations” on page 62 ■ “Enterprise Configurations” on page 63 Overview of Array Cabling Sun StorEdge T3 and[...]

  • Pagina 72

    60 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 ■ Switch connection where the FC-AL from the array is connected to a switch on the same network as the data host. Administration Path For the administration path, each controller unit has an Ethernet connector . For each installed controller , an Ethernet connection and IP addr[...]

  • Pagina 73

    Chapter 6 Array Cab ling 61 FIGURE 6-1 Sun StorEdge T3 Array Contr oller Card and Inter connect Cards FIGURE 6-2 Sun StorEdge T3+ Array Contr oller Card and Inter connect Cards Serial por t (RJ-11) 10BASE-T Ethernet por t (RJ-45) FC-AL data connection por t Note: FC-AL por t requires an MIA f or cable connection. Controller card Interconnect cards [...]

  • Pagina 74

    62 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 W orkgr oup Conf igurations The following configuration r ules apply to array workgroup conf igurations ( FIGURE 6-3 ): ■ The interconnect ports, which ar e used only in partner group configurations, cannot be used for host connections. ■ The FC-AL connection provides a data [...]

  • Pagina 75

    Chapter 6 Array Cab ling 63 Enterprise Conf igurations The following rules conf iguration rules apply to enterprise (partner gr oup) configurations ( FIGURE 6-4 ): ■ The interconnect ports, which ar e used only in enterprise configurations, cannot be used for host connections. ■ The FC-AL connection provides a data path to the application host.[...]

  • Pagina 76

    64 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001[...]

  • Pagina 77

    65 Glossary A administrative domain Partner groups (inter connected controller units) that shar e common administration through a master contr oller . alternate master controller unit Also called “alternate master unit,” the secondary array unit in a partner group that provides failover capability fr om the master controller unit. Alternate Pat[...]

  • Pagina 78

    66 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 C command-line interface (CLI) The interface between the Sun StorEdge T3 and T3+ array’s pSOS operating system and the user in which the user types commands to administer the array. controller unit A Sun StorEdge T3 and T3+ array that includes a controller car d. It can be use [...]

  • Pagina 79

    67 F Fibre Channel Arbitrated Loop (FC-AL) A 100 Mbyte/s serial channel that enables connection of multiple devices (disk drives and controllers). f ield-replaceable unit (FRU) A component that is easily removed and r eplaced by a field service engineer or a system administrator . FLASH memory device (FMD) A device on the controller car d that stor[...]

  • Pagina 80

    68 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 I input/output operations per second (IOPS) A performance measurement of the transaction rate. interconnect cable An FC-AL cable with a unique switched-loop architectur e that is used to interconnect multiple Sun StorEdge T3 and T3+ arrays. interconnect card An array component th[...]

  • Pagina 81

    69 multi-initiator conf iguration A supported array configuration that connects two hosts to one or mor e array administrative domains through hub or switch connections. P parity Additional information stored with data on a disk that enables the contr oller to rebuild data after a drive failur e. partner group A pair of interconnected contr oller u[...]

  • Pagina 82

    70 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001 reverse address resolution protocol (RARP) A utility in the Solaris operating environment that enables automatic assignment of the array IP address fr om the host. S SC An industry standard name used to describe a connector standar d. Simple Network Management Protocol (SNMP) A n[...]

  • Pagina 83

    71 W workgroup conf iguration A standalone array connected to a host system. world wide name (WWN) A number used to identify array volumes in both the array system and Solaris environment. write caching Data used to build up stripes of data, eliminating the read-modify-write overhead. W rite caching improves performance for applications that are wr[...]

  • Pagina 84

    72 Sun StorEdge T3 and T3+ Arra y Configuration Guide • August 2001[...]

  • Pagina 85

    73 Index A administration path, 60 alternate master controller unit in a partner group, 7 Alternate Pathing (AP) in configuration recommendations, 9 in partner group configuration, 30 auto cache mode, 14 C cabling overview, 59 cache allocation, configuring, 16 for improving performance, 13 mirror ed, enabling, 16 setting cache modes, 14 cache se[...]

  • Pagina 86

    74 Sun StorEdge T3 and T3+ Arra y Configuration Guide • A ugust 2001 E enterprise configuration configuration rules, 63 description, 6 See partner group Ethernet administration path, 60 connection, 2, 3 expansion units, 2 F FC-AL connections, 6 data path, 59 Fibre Channel-Arbitrated Loop (FC-AL) See FC-AL H HBA SOC+, 54 Sun StorEdge CompactPCI [...]

  • Pagina 87

    Index 75 sharing parameter settings, 9 using AP, 30 using DMP, 30 using multipathing software, 30 platforms supported, 9 R RAID and applications, 18 configuring for redundancy, 20 default level, 22 determining level requir ed, 18 levels, defined, 21 S single controller conf iguration, 6 SOC+ HBA, 54 software supported, 10 stripe unit size See dat[...]

  • Pagina 88

    76 Sun StorEdge T3 and T3+ Arra y Configuration Guide • A ugust 2001[...]