Supermicro SuperChassis 842TQ-865B manuale d’uso
- Visualizza on-line o scarica il manuale
- 63 pagine
- N/A
Vai alla pagina of
Manuali d’uso simili
-
Computer case
Supermicro SuperChassis 832S-R760
33 pagine -
Computer case
Supermicro SuperChassis 742i-450
13 pagine -
Computer case
Supermicro SuperChassis 510-200B
39 pagine -
Computer case
Supermicro SuperChassis 835TQ-R800B
61 pagine -
Computer case
Supermicro 835TQ-R920B
66 pagine -
Computer case
Supermicro SuperChassis 933E2-R760
84 pagine -
Computer case
Supermicro CSE-512-260B
68 pagine -
Computer case
Supermicro SuperChassis SC932T-R760
84 pagine
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Supermicro SuperChassis 842TQ-865B. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Supermicro SuperChassis 842TQ-865B o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Supermicro SuperChassis 842TQ-865B descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Supermicro SuperChassis 842TQ-865B dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Supermicro SuperChassis 842TQ-865B
- nome del fabbricante e anno di fabbricazione Supermicro SuperChassis 842TQ-865B
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Supermicro SuperChassis 842TQ-865B
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Supermicro SuperChassis 842TQ-865B non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Supermicro SuperChassis 842TQ-865B e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Supermicro in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Supermicro SuperChassis 842TQ-865B, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Supermicro SuperChassis 842TQ-865B, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Supermicro SuperChassis 842TQ-865B. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
SC842 Chassis Series SC842TQ-865B SC842TQ-665B SC842i-500B SC842XTQ-R606B USER’S MANUAL 1.0c S UPER ®[...]
-
Pagina 2
SC842 Chassis Manual ii Manual Revision 1.0c Release Date: July 1 1, 2012 The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manu[...]
-
Pagina 3
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SC842 chassis. Installation and maintenance should be performed by experienced technicians only . Optimized for enterprise level server systems, Supermicro's SC842 chas[...]
-
Pagina 4
SC842 Chassis Manual iv Manual Organization Chapter 1: Introduction The rst chapter provides a checklist of the main components included with this chassis and describes the primary features of the SC842 chassis. This chapter also includes contact information. Chapter 2: System Safety This chapter lists warnings, precautions, and system safety . [...]
-
Pagina 5
v Preface T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Shipping List .................................................................................................... 1-1 Part Numbers .......................................[...]
-
Pagina 6
SC842 Chassis Manual vi Removing Hard Drive Carriers (SC842TQ and SC842XTQ) .......................... 5-3 Installing a Drive to the Carrier (SC842TQ and SC842XTQ) ......................... 5-4 Installing Hard Drive Carriers (SC842TQ and SC842XTQ) ............................ 5-5 Removing the Hard Drive Cage (SC842i Series) ........................[...]
-
Pagina 7
vii Preface Appendix A SC842 Chassis Cables Appendix B SC842 Power Supply Specications Appendix C SAS-842TQ Backplane Specications[...]
-
Pagina 8
SC842 Chassis Manual viii Notes[...]
-
Pagina 9
1-1 Chapter 1 Introduction Legend: DP/UP: Dual processor/single processor FF: Full height, full length PCI slots. Chapter 1 Introduction 1-1 Overview Supermicro’s SC842 4U chassis features a unique and highly-optimized design. The chassis is equipped with a high-efciency power supply . High-performance fans provide ample optimized cooling. Up [...]
-
Pagina 10
SC842 Chassis Manual 1-2 1-3 Chassis Features The SC842 high-performance chassis includes the following features: CPU Support The SC842 chassis supports single and dual Intel/AMD processors. Please refer to the motherboard specications pages on our Web site for updates on supported processors, at www .supermicro.com. Hot-Swappable Hard Drives Th[...]
-
Pagina 11
1-3 Chapter 1 Introduction Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (T echnical Support) Web Site: www .supermicro.com Europe Address: Super Micro Computer[...]
-
Pagina 12
SC842 Chassis Manual 1-4 Notes[...]
-
Pagina 13
2-1 Chapter 2 System Safety Chapter 2 System Safety 2-1 Overview This chapter provides safety information about the SC842 chassis. These instruc - tions assume that you are an experienced technician, familiar with common con - cepts and terminology . 2-2 W arnings and Precautions Y ou should inspect the box the chassis was shipped in and note if it[...]
-
Pagina 14
2-2 SC842 Chassis Manual 2-4 Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SC842 from damage: • Be aware of the locations of the power on/off switch on the chassis as well as the room’s emergency power-of f switch, disconnection switch or electrical outlet. If an el[...]
-
Pagina 15
2-3 Chapter 2 System Safety • Please handle used batteries carefully . Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landll. Please comply with the regulations set up by your local hazardous waste management agency to dis[...]
-
Pagina 16
2-4 SC842 Chassis Manual • Use a grounded wrist strap designed to prevent electrostatic discharge. • Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use. • T ouch a grounded metal object before removing any board from its antistatic bag. • Do not let components or PCBs come into con[...]
-
Pagina 17
3-1 Chapter 3 Chassis Components Chapter 3 Chassis Components 3-1 Overview This chapter describes the most common components included with your chassis. Some components listed may not be included or compatible with your particular chassis model. For more information, see the installation instructions detailed later in this manual. 3-2 Components Ha[...]
-
Pagina 18
3-2 SC842 Chassis Manual rated at 600 W atts. (Model SC842XTQ) In the unlikely event of a power supply failure, replacement is easily accomplished without tools. 3-3 Where to get Replacement Components Although not frequently , you may need replacement parts for your system. T o ensure the highest level of professional service and technical support[...]
-
Pagina 19
4-1 Chapter 4 System Interface Chapter 4 System Interface 4-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specic components. SC842 models have two buttons on the chassis control panel: a reset[...]
-
Pagina 20
4-2 SC842 Chassis Manual 4-2 Control Panel Buttons The re ar e t wo pus h - but to ns lo c ated o n th e fro nt of t he ch as sis. T he se ar e (in or der fro m lef t to r ight), a res et but to n and a p owe r on /of f but to n. Reset: The reset button is used to reboot the system. Powe r : Th e mai n powe r swi tch i s use d to ac tiva te or re m[...]
-
Pagina 21
4-3 Chapter 4 System Interface Powe r : In dic ate s powe r is b ein g supp lie d to th e syste m's po wer sup ply u nit s. Th is LED sh oul d nor m ally b e ill umi nated w he n the sy stem i s ope rat ing . Overheat /Fan Fail : W h e n t h i s L E D a s h e s i t i n d i c a t e s a f a n f a i l u r e . W h e n c o n t i n u - ously o n[...]
-
Pagina 22
4-4 SC842 Chassis Manual 4-4 Drive Carrier LEDs Each hard drive carrier has two LEDs. Blue: Whe n ill umin ated, t his b lue L ED (on the f ront o f the d ri ve ca rr i er) indi c ates dr ive ac tiv it y. A conn ec ti on to t he bac k pla ne ena ble s th is LED t o blin k on an d of f whe n tha t par tic ul ar dr ive is b ein g ac c es sed. Red: Th[...]
-
Pagina 23
5-1 Chapter 5 Chassis Setup and Maintenance Chapter 5 Chassis Setup and Maintenance 5-1 Overview This chapter details the basic steps required to install components to the SC842 chassis. The only tool you will need is a Phillips head screwdriver . Print this chapter to use as a reference while setting up your chassis. Review the warnings and precau[...]
-
Pagina 24
5-2 SC842 Chassis Manual 5-2 Removing the Chassis Cover Removing the Chassis Cover 1. Remove the screw at the rear of the chassis and set it aside for later use. 2. Remove the two screws on the sides of the cover and set them aside. 3. Lift the cover up and off the chassis. Figure 5-1: Removing the Chassis Cover W arning: Except for short periods o[...]
-
Pagina 25
5-3 Chapter 5 Chassis Setup and Maintenance 5-3 Installing Hot-Swap Hard Drives The hot-swappable hard drives are mounted in drive carriers to simplify their instal - lation and removal from the chassis. The SC842 chassis supports up to ve 3.5" hard drives. Removing Hard Drive Carriers (SC842TQ and SC842XTQ) Removing the Hard Drive and Hard[...]
-
Pagina 26
5-4 SC842 Chassis Manual Installing a Drive to the Carrier (SC842TQ and SC842XTQ) Installing a Hard Drive 1. Remove the two screws securing the dummy drive to the drive carrier . 2. Lift the dummy drive out of the drive carrier . 3. Place the hard drive carrier on a at, stable surface such as a desk, table, or work bench. 4. Slide the hard drive[...]
-
Pagina 27
5-5 Chapter 5 Chassis Setup and Maintenance Hard Drive Carrier SAS/SA T A Hard Drive Figure 5-4: Installing a Drive into a Hard Drive Carrier Use a hard, stable surface when installing the hard drive 4 6 6 Installing Hard Drive Carriers (SC842TQ and SC842XTQ) Installing the Hard Drive Carriers 1. Reinsert the hard drive carrier into the hard drive [...]
-
Pagina 28
5-6 SC842 Chassis Manual Figure 5-5: Removing the Internal HDD Cage Removing the Hard Drive Cage (SC842i Series) Removing the Hard Drive Cage 1. Power down the system and disconnect the chassis from any source of power . 2. Remove the four screws securing the internal hard drive cage and bracket to the chassis as illustrated below and set them asid[...]
-
Pagina 29
5-7 Chapter 5 Chassis Setup and Maintenance Installing Hard Drives into the Cage (SC842i Series) Installing Drives into the Internal Hard Drive Cage 1. Insert a hard drive into the hard drive cage, aligning the holes in the drive with those in the cage. 2. Secure the drive to the top of the cage with two to three hard drive screws. 3. Secure the dr[...]
-
Pagina 30
5-8 SC842 Chassis Manual Figure 5-7: Installing the Internal HDD Cage Installing the Hard Drive Cage (SC842i Series) Installing the Hard Drive Cage 1. Shut down the system using the operating system, remove the power cord from the rear of the chassis and open the chassis cover . 2. Insert the hard drive cage through the front of the chassis. 3. Rei[...]
-
Pagina 31
5-9 Chapter 5 Chassis Setup and Maintenance 5-4 Installing an I/O Shield Installing an I/O Shield I/O shields help to hold the motherboard ports in place. Install the I/O shield that came with your motherboard before installing the motherboard. 1. Shut down the system using the operating system, remove the power cord from the rear of the chassis an[...]
-
Pagina 32
5-10 SC842 Chassis Manual 5-5 Installing the Motherboard Optional Standoffs Standoffs prevent short circuits by creating space between the motherboard and the chassis oor . The SC842 chassis includes optional removeable standoffs in locations used by motherboards. These standof fs accept the round Phillips head screws included in the SC842 acces[...]
-
Pagina 33
5-1 1 Chapter 5 Chassis Setup and Maintenance Figure 5-10: Installing the Motherboard Motherboard Installation Installing the Motherboard 1. Review the documentation that came with your motherboard. Become familiar with component placement, requirements, and precautions. 2. Shut down the system using the operating system, remove the power cord from[...]
-
Pagina 34
5-12 SC842 Chassis Manual Installing Expansion Cards 1. Shut down the system using the operating system, remove the power cord from the rear of the chassis and open the chassis cover . 2. Locate the motherboard port which is aligned with the card slot you want to install. 3. Each PCI slot cover is secured by one screw located on the top of the cove[...]
-
Pagina 35
5-13 Chapter 5 Chassis Setup and Maintenance Fan Release T ab Rear System Fans Figure 5-12: Installing the Rear Fan 1 2 1 4 Installing the Rear System Fans The SC842 chassis includes two rear exhaust fans. Installing the Rear System Fans 1. Shut down the system using the operating system, remove the power cord from the rear of the chassis and open [...]
-
Pagina 36
5-14 SC842 Chassis Manual Checking the Server's Airow Checking the Airow 1. Make sure there are no objects to obstruct the airow in and out of the server . If necessary , route and organize the cables appropriately . 2. Do not operate the chassis without drive carriers in the drive bays.[...]
-
Pagina 37
5-15 Chapter 5 Chassis Setup and Maintenance 5-6 Power Supply Most SC842 chassis models include a single xed 500, 665 or 865 Watt power supply . The SC842XTQ chassis model includes dual redundant 600 W att power supplies. In the unlikely event of a power supply failure, single power supply systems must be powered-down, the power completely disco[...]
-
Pagina 38
5-16 SC842 Chassis Manual Replacing a Redundant Power Supply (SC842XTQ) Redundant power supplies are hot-swappable and it is not necessary to power down the server before replacing the power supply . Replacing the Redundant Power Supply 1. Press the release button on the rear of the failed power supply module 2. Grasp the handle on the power supply[...]
-
Pagina 39
5-17 Chapter 5 Chassis Setup and Maintenance 1 4 Installing the DVD-ROM and Peripheral Drive SC842 chassis models supports a slim DVD-ROM and up to three 5-1/4" periph - eral drives. Figure 5-14: Installing a Peripheral Drive Installing a Peripheral Drive 1. Shut down the system using the operating system, remove the power cord from the rear o[...]
-
Pagina 40
5-18 SC842 Chassis Manual Notes[...]
-
Pagina 41
6-1 Chapter 6 Rack Installation Chapter 6 Rack Installation 6-1 Overview This chapter provides a quick setup to install the chassis into a rack. Following these steps in the order given should enable you to complete the rack installation within a minimal amount of time. 6-2 Unpacking the System Inspect the box the chassis was shipped in and note if[...]
-
Pagina 42
6-2 SC842 Chassis Manual Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the oor with the full weight of the rack resting on them. • In single rack installation, stabilizers should be attached to the rack. • In multiple rack installations, the racks should be coupled together . •[...]
-
Pagina 43
6-3 Chapter 6 Rack Installation • Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. Rack Mounting Considerations Ambient Operating T emperature If installed in a closed or multi-unit rack assembly , the ambient operating tem - perature of the rack environme[...]
-
Pagina 44
6-4 SC842 Chassis Manual 6-4 Rack Mounting Rack Mounting Overview This section provides information on installing the SC842 chassis into an open rack. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly . Y ou should also refer to the installation instructions that came with the rack unit you [...]
-
Pagina 45
6-5 Chapter 6 Rack Installation 6-5 Rack Mounting with the Optional Rail System Rail System Overview This section provides information on installing the SC842 chassis into a four-post rack unit with the optional quick-release rails. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly . Y ou sh[...]
-
Pagina 46
6-6 SC842 Chassis Manual Figure 6-3: Installing the Inner Rails Installing the Inner Rails Installing the Inner Rails 1. Place the inner rails on the side of the chassis aligning the hooks of the chas - sis with the rail holes. Make sure the rail faces "outward". 2. Slide the inner rail toward the front of the chassis. 3. Secure the chass[...]
-
Pagina 47
6-7 Chapter 6 Rack Installation Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. Installing the Outer Rails to the Rack 1. Secure the back end of the outer rail to the rack, using the screws provided. 2. Press the button where the two outer rails are joined to retract the smaller outer rail. 3. Hang the hooks of the ra[...]
-
Pagina 48
6-8 SC842 Chassis Manual screw the handles the outer rails for secure purpose if necessary F. ABLECOM DA TE:2008/08/14 REV:2 SCREW SCREW COMPLETE 1 2 Figure 6-5: Installing the Chassis into a Rack Installing the Chassis into a Rack 1. Extend the outer rails as illustrated above. 2. Align the inner rails of the chassis with the outer rails on the ra[...]
-
Pagina 49
A-1 Appendix A SC842TQ-865B, SC842TQ-665B Part # T ype Length Description CBL-0044L Cable 2' SA T A cable CBL-0087 Ribbon, Round 20" 16-pin to 16-pin ribbon cable for control panel CBL-0084L Cable 6" Front control cable, 16-pin split cable CBL-0286L Cable 30 cm 4-pin to 4-pin rear fan power exten- sion with square header . CBL-0336L [...]
-
Pagina 50
A-2 SC842 Chassis Manual SC842XTQ-R606B Part # T ype Length Description CBL-0044L Cable 2' SA T A cable CBL-0087 Ribbon, Round 20" 16-pin to 16-pin ribbon cable for control panel CBL-0084L Cable 6" Front control cable, 16-pin split cable CBL-0286L Cable 30 cm 4-pin to 4-pin rear fan power exten- sion with square header . CBL-0336L Ca[...]
-
Pagina 51
B-1 Appendix B Power Supply Appendix B SC842 Power Supply Specications This appendix lists power supply specications for your chassis system. SC842i-500B 500W MFR Part # PWS-502-PQ Rated AC V oltage 100 - 240V 50-60Hz 7-3.5 Amp +5V standby 3 Amp +12V1 17 Amp +12V2 17 Amp +12V3 17 Amp +12V4 18 Amp -12V 0.5 Amp +5V 20 Amp +3.3V 15 Amp[...]
-
Pagina 52
B-2 SC842 Chassis Manual SC842TQ-865B 865W MFR Part # PWS-865-PQ Rated AC V oltage 100 - 240V 50 - 60Hz 12 - 6 Amp +5V standby 6.5 Amp +12V 70 Amp +5V 30 Amp +3.3V 30 Amp -12V 1 Amp SC842TQ-665B 665W MFR Part # PWS-665-PQ Rated AC V oltage 100 - 240V 50 - 60Hz 10 -5 Amps +5V standby 6 Amp +12V 54 Amp +5V 30 Amp +3.3V 24 Amp -12V 0.5 Amp[...]
-
Pagina 53
B-3 Appendix B Power Supply SC842XTQ-R606B 600W MFR Part # PWS-606P-1R Rated AC V oltage 100-240 V 50-60 Hz 7.5-3.0 Amp DC Output Rating +12V 50 Amp +5V standby 3 Amp[...]
-
Pagina 54
C-1 Appendix C SAS-842TQ Backplane Specications Appendix C SAS-842TQ Backplane Specications T o avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. C-1 ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. T o prev[...]
-
Pagina 55
C-2 SC842 Chassis Manual C-3 An Important Note to Users All images and layouts shown in this user's guide are based upon the latest back - plane revision available at the time of publishing. The card you have received may or may not look exactly the same as the graphics shown in this manual. C-4 Introduction to the SAS-842TQ Backplane The SAS-[...]
-
Pagina 56
C-3 Appendix C SAS-842TQ Backplane Specications F1 F2 F3 JP52 1 2 7 8 JP51 1 2 7 8 J8 7 J7 7 J6 7 J5 7 J10 7 JP46 JP53 JP30 JP54 JP29 1 3 JP33 1 3 JP25 1 3 MH1 MH2 MH3 MH4 MH5 MH6 + C45 + C44 + C3 + C85 + C5 + C34 C35 U31 U26 U25 C A D3 4 1 JP10 4 1 JP13 1 16 32 33 48 49 64 U40 JP44 JP45 BAR CODE 1.01 REV: SAS842TQ MACH FINISH 30 ANGLE SPECIFIED[...]
-
Pagina 57
C-4 SC842 Chassis Manual #4 and #5. Sideband Connectors The sideband connectors are designated JP51 and JP52. For SES-2 to work properly , you must connect an 8-pin sideband cable. See the table to the right for pin denitions. Sideband Connectors Pin # Denition Pin # Denition 2 SDIN/ Backplane Addressing (SB5) 1 Controller ID (SB6) 4 SDOUT[...]
-
Pagina 58
C-5 Appendix C SAS-842TQ Backplane Specications #6 and #7. I 2 C Connectors The I 2 C connectors, designated JP44 and JP45, are used to monitor HDD activity and status. See the table on the right for pin denitions. I 2 C Connector Pin Denitions Pin# Denition 1 Data 2 Ground 3 Clock 4 No Connection #8 - #12. SAS/SA T A Connectors The SAS[...]
-
Pagina 59
C-6 SC842 Chassis Manual C-7 Front Jumper Locations and Pin Denitions Explanation of Jumpers T o modify the operation of the backplane, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector . Pin 1 is identied with a square solder pad on the printed circuit boar[...]
-
Pagina 60
C-7 Appendix C SAS-842TQ Backplane Specications F1 F2 F3 JP52 1 2 7 8 JP51 1 2 7 8 J8 7 J7 7 J6 7 J5 7 J10 7 JP46 JP53 JP30 JP54 JP29 1 3 JP33 1 3 JP25 1 3 MH1 MH2 MH3 MH4 MH5 MH6 + C45 + C44 + C3 + C85 + C5 + C34 C35 U31 U26 U25 C A D3 4 1 JP10 4 1 JP13 1 16 32 33 48 49 64 U40 JP44 JP45 BAR CODE 1.01 REV: SAS842TQ MACH FINISH 30 ANGLE SPECIFIED[...]
-
Pagina 61
C-8 SC842 Chassis Manual 1 C A D12 C A D13 C A D14 C A D15 C A D18 C A D19 C A D5 C A D6 C A D7 C A D8 J1 J2 J3 J4 J9 1.01 REV: SAS842TQ MACH FINISH 30 ANGLE SPECIFIED DIMENSIONS UNLESS OTHERWISE XXX XX X .010 .03 .1 TOLERANCES DECIMAL ARE IN INCHES Erni DESINGER: DA TE: 08/11/2010 PROJECT NAME: SAN JOSE,CA 95131 DESIGNED BY SUPERMICRO U.S.A. www.s[...]
-
Pagina 62
C-9 Appendix C SAS-842TQ Backplane Specications 1 C A D12 C A D13 C A D14 C A D15 C A D18 C A D19 C A D5 C A D6 C A D7 C A D8 J1 J2 J3 J4 J9 1.01 REV: SAS842TQ MACH FINISH 30 ANGLE SPECIFIED DIMENSIONS UNLESS OTHERWISE XXX XX X .010 .03 .1 TOLERANCES DECIMAL ARE IN INCHES Erni DESINGER: DA TE: 08/11/2010 PROJECT NAME: SAN JOSE,CA 95131 DESIGNED [...]
-
Pagina 63
C-10 SC842 Chassis Manual Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup - port systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to per - form be reasonably expected to resu[...]