Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ). La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
- nome del fabbricante e anno di fabbricazione Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Thermo Products in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ). Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    MC COMBOMAX Electric boiler with integrated instantaneous water heater Models from 8 kW to 24 kW : 240 Volts ( single phase ) Use and Care Manual With installation instructions for the contractor Your COMBOMAX ® electric boiler has been carefully assembled and factory tested to provide years of trouble-free service. This manual contains instructio[...]

  • Pagina 2

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 2. Section 1 : Technical specifications Table 1: Boiler specifications 240 Vac (single phase) : Pow er Nominal load in amps Model Kw BTU/h Heating elements Including the circulator Number of elements Stages Thermostats pilots Wire Cu Fuse Amps COMBOMAX XX-8 8 2[...]

  • Pagina 3

    13 6 5 10 12 3 16 8 9 F 4 7 1 I G H C B D E A 2 11 14 15 THERMO 2000 inc. DESSI N D'ATELI ER / GENERAL DI MENSI ONS COMBOMAX XX-XX Legeng/Légende: 1) Boiler Wat er Sup ply Co nnectio n / A limen tation du ch auffage (1" n pt F) 2) Boil er Water Return/ Retou r du chauf fage ( 1" np t F) 3) Dome stic W ater inle t / Entrée eau domes[...]

  • Pagina 4

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 4. General Safety Precautions Be sure to read and understand the entire Us e & Care Manual before attempting to install or operate this water heater. Pay par ticular attention to the following General Safety Precautions. Failure to follow these warnings could c[...]

  • Pagina 5

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 5. Section 3 : INSTALLATION The manufacturer’s w arranty does not cover any damage or defect caused by installation or attachment or use of any special attachment other than those authorized by the manufacturer into, onto, or in conjunction w ith the water heater[...]

  • Pagina 6

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 6. Install shutoff (ball) valves for servicing convenience. Install thermometers on the inlet and outlet lines. Never plug the pressure relief valv e to avoid creating a hazardous situation. 3.5.2 Flow-check valve If the heating system uses a single circulator, a f[...]

  • Pagina 7

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 7. Pump flow rate = Boiler output ÷ BWTD ÷ 500 • Pump flow rate is expressed in U.S. gallons per minute or GPM. • The Boiler output ( in net BTU per hour) is the maximum amount of heat to be transferred through the heating circuit to meet the hot water demand[...]

  • Pagina 8

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 8. cold water supply line between the COMBOMAX MC unit and flow check valve. Contact your installing contractor, water supplier, local plumbing inspector or plumbing supply house for assistance. 3.6.3 Recirculation line (if applicable) If a recirculation line is in[...]

  • Pagina 9

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 9. 3.11 BI-ENERGY SETUP To take advantage of a special domestic electric utility rate, your COMBOMAX MC boiler can be combined with an existing oil or gas-fired furnace. Please contact y our utility to make sure your building is eligible and to find out about the n[...]

  • Pagina 10

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 10. Section 4 : Operation Before operating this w ater heater, be sure to read and follow these instructions, as well as the w arnings printed in this manual. Failure to do so can result in unsafe operation of the w ater heater resulting in property damage, bodily [...]

  • Pagina 11

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 11. Adjust the boiler aquastats as required. Please note that lowering the setting will not have an immediate effect as the heat stored in the boiler water must first be consumed. Check the boiler water temperature periodically. Further adjustments may be required [...]

  • Pagina 12

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 12. 4.6 ADJUSTING THE MIXING VALVE A thermostatically controlled mixing valve works automatically thanks to t he thermostatic element controlling the mix of very hot and cold water as required to provide safe domestic hot water under variable conditions. To adjust [...]

  • Pagina 13

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 Section 5 : Maintenance Regular boiler maintenance will ensure trouble- free service for many years. It is recommended that you set up and follow a maintenance program. All components fail eventually. The use of incorrect repl[...]

  • Pagina 14

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 14. General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this COMBOMAX MC unit. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings co u[...]

  • Pagina 15

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajouter / to ad d P[...]

  • Pagina 16

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Plinthes à ailet tes / Fi nnes-Tube baseboard Valve de sécurité ( T&P)/ Sa[...]

  • Pagina 17

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping E a u f r o i d e d o m e s t i q u e / D o m e s t i c c o l d w a t e r s up p l y Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T P l i n t he s à a i l e t t e s / F i n ne s - T ub e b a s e [...]

  • Pagina 18

    L1 G C1 TH 1 TH 2 HL C1 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 24 0 V Modèle/Model 6 - 10 K W Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit N Circulateu r/ Circulator F Fusibl e Fuse C1 L2 Voir/see note[...]

  • Pagina 19

    L1 G C1 TH 1 TH 2 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 240V : modèle/ model 15 - 24 K W N C1 L2 C1 TH 3 TH 4 C1 Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit Fusibl e Fuse EL1 EL2 EL3 EL4 Cabla ge en [...]

  • Pagina 20

    L1 Diagramme électrique/ Wiri n g dia gr am Contrôle Bi-énergy/ Dual control ener g y CB E -E M N 120 Vac 24 Vac H H V3 V2 E1 E2 T1 T2 Bi-energie/ Dual ene r gy Electrique/ Ele ctr ic Mazout/ Oil Relais/ Re la y COMBOMAX E2 V2 T T Relais chaud ièr e mazout/ Oil boiler Re l ay Noir/ Bl ac k V1 Brun/ Br own Bl e u/ B lue B AB A Electrique/ E l ec[...]

  • Pagina 21

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajoute r/ to add B A AB Installat ion Bi-é ner[...]

  • Pagina 22

    Diagramme électrique/ Wiri n g dia gr am Raccordement de zone valves/ Wiring for zoned va lve s system Diagramme électrique/ Wiri n g dia gr am Raccordement de multiples circulateurs/ Wiring for m u ltip le cir c ula to rs 1 22 3 4 1 22 3 4 1 22 3 4 TT Block ter min a l th e r most at /Thermostat t er mi n al b l oc k sur panneau él ec tri que C[...]

  • Pagina 23

    Aquastat Priorité DHW/ DHW pr iori ty ( Sugg: 160F) Aquastat Élémen t no. 4/ Elemen t no. 4 ( Sugg: 165F) Aquastat Élémen t no. 3/ Elemen t no. 3 ( Sugg: 170F) Aquastat Élémen t no. 2/ Elemen t no. 2 ( Sugg: 175F) Aquastat Élémen t no. 1/ Elemen t no. 1 ( Sugg: 180F) Contact eur pri nci pal / Mai n Contact or Bornier de racco rdement/ Main[...]

  • Pagina 24

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 COMBOMAX TM LIMITED WARRANTY Warranty Coverage for Residential Installatio n. Thermo 2000 Inc. hereby warrants to the or iginal resident ial purchaser t hat the COMBOMAX tank and exchanger (coil assemb ly) installed in a resid[...]