TOA Electronics VF5000-CMP-2 manuale d’uso
- Visualizza on-line o scarica il manuale
- 20 pagine
- 0.93 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
TOA Electronics TM-4500
20 pagine 0.27 mb -
Indoor Fireplace
TOA Electronics P0055-DRG
20 pagine 0.89 mb -
Indoor Fireplace
TOA Electronics CR-3835L
24 pagine 0.31 mb -
Indoor Fireplace
TOA Electronics SLDVT-35
24 pagine 1.35 mb -
Indoor Fireplace
TOA Electronics RD-36
20 pagine 0.75 mb -
Indoor Fireplace
TOA Electronics BCF-3885
8 pagine 0.11 mb -
Indoor Fireplace
TOA Electronics VFST-CMN-2
24 pagine 0.51 mb -
Indoor Fireplace
TOA Electronics VF5000-CMP-2
20 pagine 0.93 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso TOA Electronics VF5000-CMP-2. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica TOA Electronics VF5000-CMP-2 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso TOA Electronics VF5000-CMP-2 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso TOA Electronics VF5000-CMP-2 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo TOA Electronics VF5000-CMP-2
- nome del fabbricante e anno di fabbricazione TOA Electronics VF5000-CMP-2
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature TOA Electronics VF5000-CMP-2
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio TOA Electronics VF5000-CMP-2 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti TOA Electronics VF5000-CMP-2 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio TOA Electronics in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche TOA Electronics VF5000-CMP-2, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo TOA Electronics VF5000-CMP-2, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso TOA Electronics VF5000-CMP-2. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903302 REV. M 12/2007 VF5000-CMN-2 VF6000-CMN-2 VF5000-CMP-2 VF6000-CMP-2 MODELS ST ANDARD SERIES INST ALLA TION AND OPERA TING INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. DO NOT BUILD A WOOD FIRE. FOR YOUR SAFETY: Do not store or use [...]
-
Pagina 2
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 These heaters are manually controlled. A spark ignition system (piezo) allows the heater pilot gas to be lit without the use of matches or batteries and permits operation of the heater during a power outage. These heaters are fitted with a specially de- signed pilot (ODS) which responds to the amoun[...]
-
Pagina 3
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nau- sea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the heater and have the Unvented Gas Heater serviced as it may not be operating corr[...]
-
Pagina 4
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Figure 1 To ensure even heat distribution, it is best to position the heater centrally against the long- est wall of the room. Make sure there is ad- equate ventilation where the heater is installed. The gas appliance will shut off if the oxygen level falls below 18.0%. These appliances are uniquely[...]
-
Pagina 5
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 PREINSTALLATION Check that all listed parts have been received. Carefully inspect the heater case and contents for shipping damage and immediately inform the dealer from whom you purchased the gas fireplace if any damage is found. The appliance is shipped with all gas controls and components install[...]
-
Pagina 6
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂ " (13 mm). Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them. 37" ([...]
-
Pagina 7
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 11 Control Valve Lower Control Compartment Door Step 3. Ensure the hood is properly positioned in the open area above the appliance door. If required insert the tabs, on each end of the hood, into the bracket at each end. Bend the two tabs over to secure. Step 4. Position appliance into prepa[...]
-
Pagina 8
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Surround Installations Note: The VF5000/VF6000 series appliances must be installed giving full consideration to the clearance and height requirements identi- fied in this manual. Figure 15 White (Supply) Black (Supply) Bipolar T erminal Screw Blower (Lower) Outlet Black Wire Mating Connectors Red Wi[...]
-
Pagina 9
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Figure 17 After setting the logs into position as shown above, ensure they are properly and firmly situated. The heater will not function as in- tended if the logs are not correctly positioned. Periodically check the positioning of the logs. WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH [...]
-
Pagina 10
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (10 mm) at the pilot generator (thermopile) should be engulfed in the pilot flame (NG only). Replace logs if removed for pilot inspection. To light the[...]
-
Pagina 11
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 Figure 23 Remote Control Kit The Model RCL adds the convenience of re- mote control for your appliance. The kit in- cludes a wireless, hand held transmitter and a receiver that replaces the wall switch. This special receiver permits either manual or re- mote control modes. Both receiver and trans- [...]
-
Pagina 12
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 RCL Remote Control RCL-STAT Rocker Switch Kit FRS Wall Switch Kit FWSK OPERATION AND CARE OF YOUR APPLIANCE 1. Appliance operation may be controlled through the optional ON/OFF unit rocker switch, located in the lower control compartment, or throug[...]
-
Pagina 13
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 VF5GDK Glass Door Panel VF6GDK Gas Flex Line Kit FFGC VF5RLK Refractory Liner Kit VF6RLK Decorative Volcanic Stone FDVS VF5-PBH Brass Hood Kit VF6-PBH VF5-BRLK Brass Louver Kits VF6-BRLK DAT-5-1 2-Piece Decorative DAT-5-4 Arch Frame Kits DAT-6-1 BSK-5 BSK-6 Brass Square STK-6-4 Surround Kits STK-5-[...]
-
Pagina 14
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 VF6000 SPECIFICATIONS Figure 25 VF5000 SPECIFICATIONS Figure 24 37" (940 mm) 36" (914 mm) 30" (762 mm) 31-1/2" (800 mm) 15" (381 mm) Front View T op View 27" (686 mm) 36" (914 mm) 15-1/2" (394 mm) Left Side View (Right Side View - Opposite) Gas Line Opening J[...]
-
Pagina 15
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot[...]
-
Pagina 16
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • If your gas supplier cannot be reached, call the fire department. C. Use only your hand to push in or turn the ga[...]
-
Pagina 17
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 NOTES:[...]
-
Pagina 18
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS LIST VF5000-CMN VF6000-CMN VF5000-CMP VF6000-CMP No. Description Part No. Qty. Part No. Qty. 1. SIT Valve - Millivolt (Natural) 903489 1 903489 1 Honeywell Valve - Millivolt (Natural) 24M13 1 24M13 1 SIT Valve - Millivolt (Propane, LPG) 901917 1 901917 1 Honeywell Valve - Millivol[...]
-
Pagina 19
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 9 10 3 15 14 4 7 6 5 16 13 1 12 (SIT Valve Shown) 14 2 8 11[...]
-
Pagina 20
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1997 by Lennox Hearth Products P/N 903302 REV. M 12/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for firepla[...]