Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Vermont Casting SHR52
24 pagine 1.68 mb -
Indoor Fireplace
Vermont Casting WinterWarm Fireplace Insert or System
44 pagine 1.45 mb -
Indoor Fireplace
Vermont Casting SA30SKHRP
20 pagine 1 mb -
Indoor Fireplace
Vermont Casting EF22
16 pagine 2.36 mb -
Indoor Fireplace
Vermont Casting SC42
24 pagine 0.32 mb -
Indoor Fireplace
Vermont Casting RHEDV32
38 pagine 0.68 mb -
Indoor Fireplace
Vermont Casting 7PDVS
24 pagine 3.31 mb -
Indoor Fireplace
Vermont Casting 33LDVT
3 pagine 0.46 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Vermont Casting SA18SHKRP. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Vermont Casting SA18SHKRP o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Vermont Casting SA18SHKRP descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Vermont Casting SA18SHKRP dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Vermont Casting SA18SHKRP
- nome del fabbricante e anno di fabbricazione Vermont Casting SA18SHKRP
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Vermont Casting SA18SHKRP
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Vermont Casting SA18SHKRP non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Vermont Casting SA18SHKRP e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Vermont Casting in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Vermont Casting SA18SHKRP, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Vermont Casting SA18SHKRP, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Vermont Casting SA18SHKRP. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Corporation Decorative G as A ppliance F or I nstallation I n S olid F uel B urning F ireplaces 331 1857 12/05 Rev . 5 Carbon Monoxide Poisoning May Lead T o Death When used without fresh air , gas logs may give off[...]
-
Pagina 2
2 331 1857 W ARNING Do not use this appliance or any part that has been under water . Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . W ARNING Y oung children are not allowed to operate this unit and must be supervised when they [...]
-
Pagina 3
3 331 1857 Before Y ou Begin -- Attention! A. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appli- ance [...]
-
Pagina 4
4 331 1857 CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Is the gas supply inlet pressure correct? NG: Min. 5.5” w .c./Max. 14.0” w .c. LP: Min. 1 1” w .c./Max. 14.0” w .c. Does the firebox meet the minimum size dimensions below? Is y[...]
-
Pagina 5
5 331 1857 This Damper Stop is designed to work on all CFM Corporation BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close com- pletely . T o install the Damper Stop: The[...]
-
Pagina 6
6 331 1857 The Damper Clamp provided keeps your damper from accidentally closing during operation of your set. This Damper Clamp must be installed onto your Damper at all times. NOTE: The damper clamp is designed to hold the damper plate open 3 inches. However , the damper must be fully open when the log set is in op- eration. Install the Damper Cl[...]
-
Pagina 7
7 331 1857 Adding Pan Material 1. Open the bag of V ermiculite and spread it evenly across the Burner Pan, to the top, as shown in Figure 5. Y ou may overflow the front and sides of the pan to cover the entire pan and connecting hardware. 2. Next, open the bag of Glowing Embers and place them on top of the V ermiculite, evenly across the Burner Pa[...]
-
Pagina 8
8 331 1857 Leak T est Procedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas sup- ply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak. T urn off the gas supply valve and tig[...]
-
Pagina 9
9 331 1857 Optional Fettel Cast Front Grate Attach the fettel to the front of the grate as shown in Figure 9. Log Placement 1. Place the larger bottom logs onto the grate, leaving as much space between them as pos- sible. When burning, the flames should come up directly between the logs. 2. Place the smaller top logs diagonally onto the bottom log[...]
-
Pagina 10
10 331 1857 LG333 18" Standard split log set 4/04 djt 18” Standard Split Log Set LG333 LG334 24" Standard split log set 4/04 djt 24” Standard Split Log Set LG334 LG335 30" Standard split log set 4/04 djt 30” Standard Split Log Set LG335 LG336 18" Standard combo log set 4/04 djt 18” Standard Combination Log Set L[...]
-
Pagina 11
1 1 331 1857 The pilot will resist lighting on new installa- tions due to air in the gas supply line. It may take several minutes to bleed air completely out of the gas plumbing system through the pilot line. This appliance has a pilot which is lit by a spark ignition device (piezo). If the piezo fails, then light the pilot using matches following [...]
-
Pagina 12
12 331 1857 T roubleshooting Log Set Is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets (especially propane) to produce moderate levels of carbon (soot) where flame contacts the logs. The logs can be cleaned using a soft-bristle brush. How- ever , if soot is produced where there is no flame impingement, one of th[...]
-
Pagina 13
13 331 1857 T roubleshooting Pilot Will Not Light Upon initial installation, the pilot may be difficult to light, due to air in the gas line, valve, and pilot tubing. If the pilot does not light for several minutes, try using a match to ignite it for the first few times. Initialing lighting the pilot may take up to five minutes of bleeding the l[...]
-
Pagina 14
14 331 1857 857 ASHKRN/P parts 4/04 djt 1 2 3 4 5 4 6 7a,b 8 10 9 1 1 13 14 12 18a,b 20 21 19 15 17 16a,b 22 24 23 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SA18/24/30SHK Series V ented Gas Logs - Remote Hearth Kit Ref. Descrip[...]
-
Pagina 15
15 331 1857 SA18/24/30SHK Series V ented Gas Logs - Remote Hearth Kit (Continued) Ref. Description 18” 24” 30” 13. Gas Supply Fitting 3304145 3304145 3304145 14. Flexible Gas Connector 3304176 3304176 3304176 15. Pilot Bracket 4303232 4303232 4303232 16a. Natural Gas Pilot Assembly 20000540 20000540 20000540 16b. Propane Gas Pilot Assembly 20[...]
-
Pagina 16
16 331 1857 5a 5b 5c 5d 5e 5f 956 Log parts 4/04 1a 1b 1c 1d 1e 1f 1 2a 2b 2c 2d 2e 2f 2g (2) 2 3a 3b 3c 3e 3f 3g 3d 3h 3 4a 4b 4c 4d 4e 4f 4 5 6a 6b 6c 6d 6e (2) 6f (2) 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e (2) 9f 9g 9h 9j 9 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and disc[...]
-
Pagina 17
17 331 1857 5c. 24” Split right Front 20007828 5d. 24” Split Left Front 20007830 5e. T op Log #3 (2 per set) 20008337 5f. T op Log (2 per set) 20008336 6. 30” Standard Split Log Set 20007859 6a. 18”/24”/30” Back Log 20007820 6b. 18”/24”/30” Cross Log 20007699 6c. 30” Split Right Front 20007831 6d. 30” Split Left Front 20007832[...]
-
Pagina 18
[...]
-
Pagina 19
THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FOR TH IN P ARAGRAPHS A AND B. A. Gas Appliances, electrical and manual compo - nents, glass panels, all sealants or adhesives and op- tional accessories (exclusive of CFM Corporation supplied decorative logs which are covered by a separate warranty under pa[...]
-
Pagina 20
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Corporation[...]