Xantrex Technology RS232-HPD manuale d’uso
- Visualizza on-line o scarica il manuale
- 62 pagine
- 0.54 mb
Vai alla pagina of
Manuali d’uso simili
-
Power Supply
Xantrex Technology GPIB-M-HPD
134 pagine 1.27 mb -
Power Supply
Xantrex Technology XPR 100-60
80 pagine 2.08 mb -
Power Supply
Xantrex Technology XDC 600-10
284 pagine 6.29 mb -
Power Supply
Xantrex Technology XPL 30-2
36 pagine 0.61 mb -
Power Supply
Xantrex Technology GT3.0
110 pagine 1.66 mb -
Power Supply
Xantrex Technology 60 A (XADC-60)
20 pagine 0.5 mb -
Power Supply
Xantrex Technology XPR 20-300
80 pagine 2.08 mb -
Power Supply
Xantrex Technology SW Plus 2548
344 pagine 3.85 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Xantrex Technology RS232-HPD. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Xantrex Technology RS232-HPD o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Xantrex Technology RS232-HPD descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Xantrex Technology RS232-HPD dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Xantrex Technology RS232-HPD
- nome del fabbricante e anno di fabbricazione Xantrex Technology RS232-HPD
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Xantrex Technology RS232-HPD
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Xantrex Technology RS232-HPD non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Xantrex Technology RS232-HPD e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Xantrex Technology in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Xantrex Technology RS232-HPD, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Xantrex Technology RS232-HPD, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Xantrex Technology RS232-HPD. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Operating Manual Internal RS-232 Interface for XT/HPD Series Programmable DC Power Supplies RS232-XT RS232-HPD[...]
-
Pagina 2
[...]
-
Pagina 3
Operating Manual for Internal RS-232 Interface for XT 60 Watt and HPD 300 Watt Series Programmable DC Power Supplies[...]
-
Pagina 4
ii Operating Manual for RS-232 for XT/HPD Series Power Supply Limited W arranty What does this warranty cover and how long does it last? This Limited W arranty is provid ed by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your RS-232 Interface Card . This warranty lasts for a W arranty Period of 5 yea[...]
-
Pagina 5
Release 1.1 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy described in your pr oduct manu al. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty[...]
-
Pagina 6
iv Operating Manual for RS-232 for XT/HPD Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE PERMIT TED BY LAW , IN LIEU OF ALL OTHER W ARRANTIES, CONDITIONS , GUARANTEES, REPRESENT A TIO NS, OBLI GA TIONS AND LIABILITIES, EXPRE[...]
-
Pagina 7
Release 1.1 v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNL ESS SPECIFICALL Y AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR OT HER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b. A S[...]
-
Pagina 8
vi Operating Manual for RS-232 for XT/HPD Ser ies Power Supply Power Supply Safety W arnings, Cautions, and Notes W arnings, cautions, and notes are defined and formatted in this manual as shown below . W ARNING—High Energy and High V o lt age Exercise caution when using and calibrating a power supply . High energy levels can be stored at the out[...]
-
Pagina 9
Release 1.1 vii About This Manual This technical manual is for the RS-2 32 Interface, a microprocessor-controlled option card for all models of XT and HPD Series DC output power supplies. This manual provides you with specificatio ns, user options, and configuration instructions for the interface, along with a command set which allows you to contro[...]
-
Pagina 10
About This Manu al viii Operating Manual for RS-232 for XT/HPD Series Power Supply[...]
-
Pagina 11
Release 1.1 ix Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specifications Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features and Functions . . . . . .[...]
-
Pagina 12
Content s x Operating Manual for RS-232 for XT/HPD Series Power Supply Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Accumulated Status, Status, and Fault Regis[...]
-
Pagina 13
Release 1.1 11 Section 1. Features and S pecifications Description The RS-232 Interface is a microprocessor-co ntrolled option card for all models of the XT and HPD Series of DC output power supply . Installed in ternally , the RS-232 interface card gives you remote digital control of simple test systems. It features fast, 16-bit resolution for pro[...]
-
Pagina 14
Features and Specifications Features and Functions 12 Operating Manual for RS-232 for XT/HPD Series Power Supply Features and Functions Features • 16-bit programming and read back of voltage and curren t • Programmable over volta ge protection with reset • Easy-to-use, self-docum enting command set • User -programmable isolated fa ult, pola[...]
-
Pagina 15
Features and Specifications Specifications Release 1.1 13 Specifications The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice. T able 1.1 S pecifications for XT 60 W Series S upply with RS-232 Interface Installe d Models 7-6 15-4 20-3 30-2 60-1 120-0.5 2[...]
-
Pagina 16
Features and Specifications Specifications 14 Operating Manual for RS-232 for XT/HPD Series Power Supply Ta b l e 1 . 2 S pecifications for HPD 300 W Series Supply with RS-232 Inte rface Installed Models 15-20 30-10 60-5 Program Resolution V oltage Current OVP 2.4mV 2.8mA 2.4mV 4.7mV 1.4mA 4.7mV 9.3mV 0.7mA 9.3mV Program Accuracy 1 V oltage Current[...]
-
Pagina 17
Release 1.1 15 Section 2. Inst allation and Configuration Introduction T o use this product, you must have the following equipment: • a compatible model of DC output power suppl y • serial extender cable (straight through) • computer with an RS-232 interface (serial port) • computer-based communications software package The RS-232 interface[...]
-
Pagina 18
Installa tion and Configuration Initial Inspection 16 Operating Manual for RS-232 for XT/HPD Series Power Supply Figure 2.1 Power Supply Front Panel with RS-232 Interface Installed Figure 2.2 Power Supply Rear Panel with RS-232 Interface I nstalled Remote Mode (REM) LED Service Request (SRQ) LED GPIB Only Over V oltage Protection (OVP) L ED OVP Pot[...]
-
Pagina 19
Inst allation and Configuration Initial Inspection Release 1.1 17 Figure 2.3 RS-232 Interface PCB See next page for designation descriptions.[...]
-
Pagina 20
Installa tion and Configuration Initial Inspection 18 Operating Manual for RS-232 for XT/HPD Series Power Supply Figure 2.3, RS-232 Inte rface PCB continued. JUMPER SELECTION J95 Local OVP control selection [closed] [default]. See page 29 . [open] See T able 2.13, on page 29 . J1 17 User TTL shutdown (S/D) selection [1-2] User TTL S/D line active l[...]
-
Pagina 21
Inst allation and Configuration Basic Setup Procedure Release 1.1 19 Basic Setup Procedure This procedure can be used as a quick reference for those familiar with the configuration requirements for the RS-232 interface as installed in the DC power supply . For those who want mo re information, each step refers to more detailed procedures located in[...]
-
Pagina 22
Installa tion and Configuration Basic Setup Procedure 20 Operating Manual for RS-232 for XT/HPD Series Power Supply Ta b l e 2 . 1 Setup Procedure Step # D escription Action Reference 1 Baud Rate Selection Select transmission speed See “Baud Rate Selection” on page 21 . 2 Flow C ontrol Selection Set flow control ON or OFF . If flow control is s[...]
-
Pagina 23
Inst allation and Configuration Communications Release 1.1 21 Communications Baud Rate Selection Serial tran smission se nds and rece ives data in bit streams at fixed bit rates. Both the computer and the interface must have the same bit rate setting for proper communication. Use switches B1, B2, and B3 on the rear panel SW1 switch to select the po[...]
-
Pagina 24
Installa tion and Configuration Communications 22 Operating Manual for RS-232 for XT/HPD Series Power Supply Flow Control Selection Flow control signals regulate data flow for proper communication. Use the FLOW switch on the rear panel S1 switch to select flow control or to disable flow control. W ith flow control enabled, you can use either softwa[...]
-
Pagina 25
Inst allation and Configuration Communications Release 1.1 23 Hardware Flow Control Hardware flow control protocol r equires a dedicated control line on the RS-232 cable. The dedicated control line is need ed so that the device can signal the controller when it is ready to receive da ta. Y ou can designate either R TS/CTS or DTR/DSR protocol for th[...]
-
Pagina 26
Installa tion and Configuration Communications 24 Operating Manual for RS-232 for XT/HPD Series Power Supply Connections Use a 9-pin (DB9) to 9-pin parallel cable to connect the interface card to the serial port on the host computer . If you need to use a 25-pin connector (DB25) on the host interface, ensure the correct connections are made by refe[...]
-
Pagina 27
Inst allation and Configuration Remote/Local Operation Release 1.1 25 Remote/Local Operation Remote / Local Switch Use the rear panel Remote/Local switch, SW1-1, to toggle between remote and local operation without losing the progra mmed values. See T able 2.9 for the switch settings. T able 2.9 Remote/Local S tart-up Settings. LOC Command Ensure t[...]
-
Pagina 28
Installa tion and Configuration Remote/Local Operation 26 Operating Manual for RS-232 for XT/HPD Series Power Supply T able 2.1 1 Remote Mode Powe r On Conditions Remote Mode Operation While in remote mode, use the interface commands to control the output of the power supply from a computer . See Section 3 for a complete list of device-depend ent c[...]
-
Pagina 29
Inst allation and Configuration RS-232 Connection Release 1.1 27 RS-232 Connection Use an app roved RS-232 co nnector an d cable when connecting the RS-232 Interface to your computer . The RS-232 connector uses the 9 pin mating connector J4 on the rear panel. Figure 2.4 shows the connector pinouts for the RS-232 connector . Refer to Figure 2.2, on [...]
-
Pagina 30
Installa tion and Configuration Power Supply Settings 28 Operating Manual for RS-232 for XT/HPD Series Power Supply Power Supply Settings For serial communica tion, the computer and the RS -232 interface must share the same communication set tings. Make sure that the settin gs of the computer and of the power supply agree with those shown in T able[...]
-
Pagina 31
Inst allation and Configuration User Options and Settings Release 1.1 29 User Options and Settings Y ou can customize remote operation settin gs for OVP (over voltage protection) control and TTL shu tdown by changing ju mper positions on the RS-23 2 PCB. Refer to the operatin g manual for information on how to use over voltag e protection and TTL s[...]
-
Pagina 32
Installa tion and Configuration User Options and Settings 30 Operating Manual for RS-232 for XT/HPD Series Power Supply TTL Shut down Y ou can use the Shutdown function t o di sable or enable the supply's output. Disabling the supply using TTL shutdown allows you to make adjustments to the load or to the power supp ly without shutting down th [...]
-
Pagina 33
Inst allation and Configuration User Signals Release 1.1 31 User Signals Connector J7 User Signals Auxiliary connector J7, loca ted on the RS-232 interface rear panel, provides several signals to increase your operating control of the supply . These signals are dependent on the operator's design and uses. The operation of the J7 signal require[...]
-
Pagina 34
Installa tion and Configuration User Signals 32 Operating Manual for RS-232 for XT/HPD Series Power Supply Figure 2.6 J7 User Signal Connector Circuit Block Diag ram J7 Cable Connection Use a standard 8-position RJ 45 connector and da ta cable to connect to J7. Add a ferrite block to reduce radiated emission . The one inch square ferrite block with[...]
-
Pagina 35
Inst allation and Configuration User Signals Release 1.1 33 Figure 2.7 J7 User Cable w ith Ferrite Block J7 User Cable Ferrite Block T o User Custom Interface T o J7 Connector[...]
-
Pagina 36
Installa tion and Configuration User Signals 34 Operating Manual for RS-232 for XT/HPD Series Power Supply[...]
-
Pagina 37
Release 1.1 35 Section 3. Operation Introduction This section covers RS-232 interface prog ramming, including an extensive set of commands, and providing error codes, and status and fault register information. RS-232 Operation The RS-232 interface card allows you to se nd and rec eive data be tween your power supply and computer . Y ou can use the [...]
-
Pagina 38
Operation Command Syntax 36 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Format and Parameters The device-dependent language for the RS -232 Interface consis ts of commands and parameters. A command is a one word code which either gives instructions to the interface or asks for inform ation from the interface. A co mmand may b[...]
-
Pagina 39
Operation Command Syntax Release 1.1 37 T able 3.1 Command Parameter s Floating Point Number <float> V ariables sent with command parameters are floating point numbers. T able 3.2 defines the structure of floating point numbers for use with the software commands. T able 3.2 Floating Point Numbers Parameter Description Form <current> The[...]
-
Pagina 40
Operation Command Syntax 38 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Strings If you send more than one command line, separate the commands with a semicolon. The semicolon may be preceded or followed by spaces. Example: Command T erminators T erminators indicate the end of a command string and tell the power supply to execu[...]
-
Pagina 41
Operation Command Summary Release 1.1 39 Command Summary Use these commands to control the operation of the supply . They are listed here in order of function such as PROGRAMMING , QUER Y , CALIBRA TION, and ST A TUS co mmands. See “Comma nd Refere nce” on page 42 fo r more detailed information about each command and its use. T able 3.3 Program[...]
-
Pagina 42
Operation Command Summary 40 Operating Manual for RS-232 for XT/HPD Series Power Supply T able 3.4 Query Commands Command Description AUXA? Asks for the state of the set value for the AUXA command AUXB? Asks for the state of the set value for the AUXB command CMODE? Asks for the power supply’ s calibration mode status. DL Y? Asks for the programm[...]
-
Pagina 43
Operation Command Summary Release 1.1 41 T able 3.5 Calibration Commands T able 3.6 S tatus Commands Command Description CMODE Places the supply into calibration mode. IDA T A Calculates the slope and intercept for current programming. IHI Sets the current output to the high calibration point. ILO Sets the current output to the low calibration po i[...]
-
Pagina 44
Operation Command Reference 42 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Reference T able 3.7 Command Refere nce Command Description ASTS? Returns the supply’s accumulated st atus register . The accumulated status register stores any bit that was entered in the status register since the accumulated status query command (A[...]
-
Pagina 45
Operation Command Reference Release 1.1 43 Command Description DL Y <seconds> Sets a programmable time delay employed by the supply before rep orting fault conditions. The power supply uses the time delay after receiving a new output voltage or current setting via VS ET or ISET , or after receiving RST , TRG , or OUT ON commands. During the t[...]
-
Pagina 46
Operation Command Reference 44 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Description FOLD? Returns the supply’s present foldback setting. Response: FOLD <mode> where mode is: 0 (OFF) or 1 (CV or Constant V oltage mode) or 2 (CC or Constant Current mode) HOLD <1/ON>,<0/OFF> Enables or disables voltage/cur[...]
-
Pagina 47
Operation Command Reference Release 1.1 45 Command Description IOUT? Measures and returns the supply’s actual current output using the built-in current readback circuitry . Response: IOUT <current> IRDA T <Ilo>,<Ihi> Calculates and records the slope and offset for readback voltage using IRLO and IRHI data. Se t CMODE ON before u[...]
-
Pagina 48
Operation Command Reference 46 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Description OUT <1/ON>,<0/OFF> Enables or disables the supply’s voltage/current output. The supply will continue to accept new commands while the output is disabled but these will not be implemented until OUT ON or OUT 1 is received. OUT [...]
-
Pagina 49
Operation Command Reference Release 1.1 47 Command Description TRG Causes programmed voltage and current settings which had been in hold mode to be applied. The supply operates with previous values until the TRG (trigger) command is sent. UNMASK <mnemonics> Selects the supply operating c onditions that you are most interested in monitoring fo[...]
-
Pagina 50
Operation Command Reference 48 Operating Manual for RS-232 for XT/HPD Series Power Supply Command Description VMAX <voltage> Sets an upper sof t limit on the supply’s programmed output volt age. If the soft limit is exceeded, or if the sof t limit value is lower than the present output voltage setting, the supply will ignore the command, tu[...]
-
Pagina 51
Operation Accumulated Status, S tatus, and Fault Registers Release 1.1 49 Accumulated S t atus, S t atus, and Fault Registers The RS-232 option card uses thre e separate registers which are always active. They are the accumulated status, status, and fa ult registers. Y ou can use the status commands shown in T able 3.6, “Status Co mmands” to ac[...]
-
Pagina 52
Operation Accumulated Status, S tatus, and Fault Registers 50 Operating Manual for RS-232 for XT/HPD Series Power Supply T able 3.8 Accumulated S tatus, S tatus, and Fault Reg isters Notes: 1. Only CC, CV , OV , SD, ERR and FO LD can be masked or unmasked. 2. The error (ERR) bit is reset in t he accumulate d status, status, and serial poll regist e[...]
-
Pagina 53
Operation Error Codes Release 1.1 51 Error Codes If the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an error number which corresponds to an event described in the following table. The ERR? query will also clear the ERR bit in the register . T able 3.9 Error Codes ERROR # ERROR IDENTIFICA TION [...]
-
Pagina 54
Operation T roubleshooting 52 Operating Manual for RS-232 for XT/HPD Series Power Supply T roubleshooting Diagnostic LEDs This section describes the diagnostic LEDs found on the RS-232 interface. Computer Operating Properly (COP) LEDs The RS-232 interface provides three diagnostic LEDs, located at CR13, CR14, and CR141 on its PCB. Refer to Figure ,[...]
-
Pagina 55
Release 1.1 53 Section 4. Calibration Introduction Y ou can calibrate the RS-232 interface by ad justing the signal levels on the interface card so that they correspond to the expec ted signal levels on the power supply's main assembly . Y ou may need to recalibrate the in terface if you replace parts either on the interface board or on the ma[...]
-
Pagina 56
Calibration V oltage Mode Calibration 54 Operating Manual for RS-232 for XT/HPD Series Power Supply V olt age Mode Calibration V oltage Calibration Setup 1. Disconnect the load from the power su pply which is to be calibrated. 2. Connect a voltmeter across the po wer supply’ s output terminals. Figure 4.1 V oltage Calibration Setup V oltage Progr[...]
-
Pagina 57
Calibration V o ltage Mode Calibration Release 1.1 55 V oltage Readback Calibration Procedure 1. Set the power supply for calibration as in Figure 4.1. 2. Activate calibration mode by sendi ng command CMODE ON or CMODE 1 to the power supply . 3. Send command VRLO; I RLO to the power supply . W ait for the supply to settle. Measure and record the ou[...]
-
Pagina 58
Calibration Current Mode Calibration 56 Operating Manual for RS-232 for XT/HPD Series Power Supply Current Mode Calibration Current Calibration Setup 1. Disconnect the load from the po wer supply to be calibrated. 2. Connect a shunt across the supply's output terminals. Ensure the shunt is rated to handle the maximu m voltage and current outpu[...]
-
Pagina 59
Calibration Current Mode Calibration Release 1.1 57 Current Readback Calibration Procedure 1. Connect the current sh unt and voltmeter to the power supply as shown in Figure 4.2. 2. Activate calibration mode by sendi ng command CMODE ON or CMODE 1 to the power supply . 3. Send command IRLO; VRLO to the power supply . W ait for the supply to settle.[...]
-
Pagina 60
Calibration Over V olta ge Protection (OVP) Calibration 58 Operating Manual for RS-232 for XT/HPD Series Power Supply Over V oltage Protection (OVP) Calibration W e recommend that you perform OVP ca libration every six mon ths. Connecting a digital voltmeter as in “V oltage Calibration Setu p” is optional. 1. Disconnect all loads from the power[...]
-
Pagina 61
[...]
-
Pagina 62
Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B5 604 422 8595 T el 604 421 3056 F ax 800 667 8422 T oll Free North America prg.info@xantrex.com www .xant rex.com TM-RS6H-01XN PRINTED IN CANADA[...]