Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Xantrex Technology XFR 2800. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Xantrex Technology XFR 2800 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Xantrex Technology XFR 2800 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Xantrex Technology XFR 2800 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Xantrex Technology XFR 2800
- nome del fabbricante e anno di fabbricazione Xantrex Technology XFR 2800
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Xantrex Technology XFR 2800
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Xantrex Technology XFR 2800 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Xantrex Technology XFR 2800 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Xantrex Technology in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Xantrex Technology XFR 2800, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Xantrex Technology XFR 2800, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Xantrex Technology XFR 2800. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Operating Manual XFR 2800 Watt Series Programmable DC Power Supply XFR 7.5-300 XFR 12-220 XFR 20-130 XFR 33-85 XFR 40-70 XFR 60-46 XFR 100-28 XFR 150-18 XFR 300-9 XFR 600-4[...]
-
Pagina 2
[...]
-
Pagina 3
Operating Manual for XFR 2800 Watt Series Programmable DC Power Supply[...]
-
Pagina 4
ii Operating Manual for XFR 2.8kW Series Power Supply Limited W arranty What does this warranty cover and how long does it last? This Limited W arranty is provid ed by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your XFR 2800 W att Series DC Power Supply . This warranty lasts for a W arranty Period [...]
-
Pagina 5
Release 2.1 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy described in your pr oduct manu al. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty[...]
-
Pagina 6
iv Operating Manual for XFR 2.8kW Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE PERMIT TED BY LAW , IN LIEU OF ALL OTHER W ARRANTIES, CONDITIONS , GUARANTEES, REPRESENT A TIO NS, OBLI GA TIONS AND LIABILITIES, EXPRESS OR IM[...]
-
Pagina 7
Release 2.1 v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR OT HER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b. A SS[...]
-
Pagina 8
vi Operating Manual for XFR 2.8kW Series Power Supply W arnings and Cautions W arnings and cautions are defined and fo rmatted in this manual as shown below . Power Supply Safety W ARNING Describes a potential hazard which could result in injury or death, or , a procedure which, if not performed correctly , could result in injury or death. ! CAUTIO[...]
-
Pagina 9
Release 2.1 vii About This Manual This Operating Manual contains user information for the XFR Series of variable DC output power supp lies, available in several voltage mode ls at 2800 W atts. It provides information ab out features and specifica tions, installation procedures, and basic functions testing, as well as operating pr ocedures for using[...]
-
Pagina 10
About This Manu al viii Operating Manual for XFR 2.8kW Series Power Supply Power Supply Safety Markings Alternating Current Off (Supply) Earth (Ground) T ermin al Caution (Hot Surface) Protective Conductor T erminal Caution (Check manual for additional info rmation.) On (Supply)[...]
-
Pagina 11
Release 2.1 ix Content s About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x i List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Pagina 12
x Operating Manual for XFR 2.8kW Series Power Supply Connecting Single Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Connecting Multiple Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Local and Remote Sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Pagina 13
Release 2.1 xi List of Figures Figure 1.1 Power Supply Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 1.2 Power Supply Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 1.3 Programming and Monitoring SW1 Switch . . . . . . . . . . . . . . . . . . . . . 20 Figure 1.4 P[...]
-
Pagina 14
List of Figures xii Operating Manual for XFR 2.8kW Series Power Supply[...]
-
Pagina 15
Release 2.1 xiii List of Tables Table 1.1 Available Voltage and Current Ranges . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 1.2 Rear Panel SW1 Switch Assignments . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 1.3 Rear Panel J2 Connector Terminals and Functions . . . . . . . . . . . . . . 23 Table 1.4 Specifications for 7.5 V[...]
-
Pagina 16
List of T ables xiv Operating Manual for XFR 2.8kW Series Power Supply[...]
-
Pagina 17
Release 2.1 15 Section 1. Features and S pecifications Description This series of power supplies provides low noise, precisely regulated, variable DC output at 2800 watts of output powe r . Over voltage protection (OVP) and thermal shutdown are standard. Front panel controls and indicators are extensive. Select from several remote control choices: [...]
-
Pagina 18
Features and Specifications Features and Options 16 Operating Manual for XFR 2.8kW Series Power Supply • Front panel push-button c ontrol of output standb y mode and preview of v oltage, current, or over voltage protection setpo ints. Front panel light emitting diode (LED) indicators for voltage and cu rrent mode operation, OVP , remote programmi[...]
-
Pagina 19
Features and Specifications Front Panel Controls Release 2.1 17 Front Panel Controls See Figure 1.1 to review the co ntrols, LEDs, and meters located on the power supply’ s front pane l. Check the following sections for additional descrip tions of front panel controls and functio ns. • “Mechanical Specifications” on page 33 • “Functiona[...]
-
Pagina 20
Features and Specifications Rear Panel Connectors and Switch 18 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel Connectors and Switch Use the rear panel SW1 Programming, Monit oring, and Shutdown Select switch and the rear panel J2 Programming and Monito ring connector to choose among several remote programming and monitoring o ptions[...]
-
Pagina 21
Features and Specifications Rear Panel Connectors and Switch Release 2.1 19 Figure 1.2 Power Supply Rear Panel (Low voltage (7.5 V to 100 V) model shown.) Blank Subplate (Replaced if digit al programming interface install ed.) SW1 Switch (See page 20 fo r more information.) 1 Resistive Programming of Outpu t V oltage 2 Resistive Programming of Outp[...]
-
Pagina 22
Features and Specifications Rear Panel Connectors and Switch 20 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel SW1 Switch The SW1 Programming, Monito ring, and Shutdown Select switch is an 8-position piano DIP switch located on the power supply’ s rear panel. See Figure . The SW1 switch enables you to choose: • Resistive programm[...]
-
Pagina 23
Features and Specifications Rear Panel Connectors and Switch Release 2.1 21 T able 1.2 Rear Panel SW1 Switch Assignments Resetting the Switches Before making any chang es to the switch settings, disable the power supply output by push ing the front panel ST ANDBY switch to its IN position. This temporar ily shuts down the power su pply . The front [...]
-
Pagina 24
Features and Specifications Rear Panel Connectors and Switch 22 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel J2 Connector The J2 Programming and Mo nitoring connector is a 15-terminal wire clamp connector located on the power supply’ s rear panel. See Figure 1.4. The J2 connector provides access to the following functions: • Re[...]
-
Pagina 25
Features and Specifications Rear Panel Connectors and Switch Release 2.1 23 T able 1.3 Rear Panel J2 Connector T erminals and Functions Connector Reference Name Function J2-1 VRMT Remote Output V oltage Programming Select Selects remote output volta ge programming when jumpered to pin 3. J2-2 IRMT Remote Output Current Limit Programming Select Sele[...]
-
Pagina 26
Features and Specifications Rear Panel Connectors and Switch 24 Operating Manual for XFR 2.8kW Series Power Supply Making J2 Connections Make connections to the J2 connector using its screw-type wire clamps. Before making any connections, turn the power su pply OFF and wait until the front panel displays have go ne out. Y ou can unplug the co nnect[...]
-
Pagina 27
Features and Specifications Specifications Release 2.1 25 Specifications Electrical Specifications These specifications are warranted over a temperature range of 0 °C to 50 °C. Nominal ambient temperature assumed is 25 °C. Nominal line voltage is 208 V ac, 60 Hz. See T able 1.4 and T able 1.5 for maximum values fo r model-dependent specification[...]
-
Pagina 28
Features and Specifications Specifications 26 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 1 . 4 S pecifications for 7.5 V to 40 V Models Models 7.5-300 12-220 20-130 33-85 40-70 Output Ratings: Output V oltage 1 Output Current 2 Output Power 0-7.5 V 0-300 A 2250 W 0-12 V 0-220 A 2640 W 0-20 V 0-130 A 2600 W 0-33 V 0-85 A 2805 W 0-40[...]
-
Pagina 29
Features and Specifications Specifications Release 2.1 27 1. Minimum output voltage is <0.15% of rated volt age at zero out put setting. 2. Minimum output current is <0.5% of rat ed current at zero outpu t setting when me asured at minimum 10 % of full power load. 3. For input volta ge variation over the AC input volt age range, with constant[...]
-
Pagina 30
Features and Specifications Specifications 28 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 1 . 5 S pecif ications for 60 V to 600 V Models Models 60-46 100-28 150-18 300-9 600-4 Output Ratings: Output V oltage 1 Output Current 2 Output Power 0-60 V 0-46 A 2760 W 0-100 V 0-28 A 2800 W 0-150 V 0-18 A 2700 W 0-300 V 0-9 A 2700 W 0-600 V[...]
-
Pagina 31
Features and Specifications Specifications Release 2.1 29 1. Minimum output voltage is <0.15% of rated volt age at zero out put setting. 2. Minimum output curre nt is <0.5% of rated current at zero outpu t setting when measured at minimum 10% of full power load. 3. For input volta ge variation over the AC input volt age range, with constant r[...]
-
Pagina 32
Features and Specifications Specifications 30 Operating Manual for XFR 2.8kW Series Power Supply Additional Specifications Input Conditions Figure 1.5 T ypical Input Current Character istics (Based on 100 V , 28 A model.) Rise T ime (No Load, Full Load) : 1 7.5 V to 60 V models: 100 ms ; 100 V to 600 V models: 170 ms Fall T ime (No Load): 1 4 s Fal[...]
-
Pagina 33
Features and Specifications Specifications Release 2.1 31 Additional Features Remote Programming and Monitoring Switching Frequency nominal 31 kHz (62 kHz output ripple). Output Hold-up Time Greater than 10 ms with interruption of AC line, for nominal AC input and full load. Maximum V oltage Differential from either output to safety ground ±600 Vd[...]
-
Pagina 34
Features and Specifications Specifications 32 Operating Manual for XFR 2.8kW Series Power Supply Environmental Sp ecification s Operating T emperature Range 0 °C to 50 °C. S torage T emperature Range -20 ° C to +70 °C Humidity Range up to 90% RH non-condensing Operating Altitude Up to 6,500 feet (2000 m) S torage Altitude Up to 50,000 feet (15 [...]
-
Pagina 35
Features and Specifications Specifications Release 2.1 33 Mechanical Specifications Front Panel V and I Control 10 -turn voltage and current potentiometers Front Panel V oltage Control Resolution 0.02% of maximum voltage Front Panel V oltage and Current Meters 3.5-digit green numeric LED displays. For accuracy specifications, see T able 1.4 and T a[...]
-
Pagina 36
Features and Specifications Specifications 34 Operating Manual for XFR 2.8kW Series Power Supply Figure 1.6 Dimensional Drawings (Dimensions given are n ominal.) 3.45" (87.63 mm) 20.975in. (533 mm) 17.475in. (444 mm) 16.9in. (429 mm) 19in. (483 mm)[...]
-
Pagina 37
Release 2.1 35 Section 2. Inst allation Introduction This section provides recomm endations and procedures for inspecting, installing, and testing the power supply . Basic Setup Procedure See T able 2.1 for a summary of the basic set up procedure and an overall view of the subsections in Section 2. Use the procedure as a quick reference if you are [...]
-
Pagina 38
Installa tion Inspection, Cleaning, an d Packaging 36 Operating Manual for XFR 2.8kW Series Power Supply Inspection, Cleaning, and Packaging Initial Inspection When you first re ceive your unit: 1. Inspect the unit for scratches and cracks, and for broken switches, connectors, and displays. 2. Ensure that the packing box contains the AC input cover[...]
-
Pagina 39
Inst allation Returning Power Supplies to the Manufactu rer Release 2.1 37 Returning Power Suppli es to the Manufacturer Return Material Authorization Policy Before returning a product di rectly to Xantrex you must obtain a Return Mat erial Authorization (RMA) number and the correct factory “Ship T o” address. Products must also be shipped prep[...]
-
Pagina 40
Installa tion Returning Power Supplies to the Manufacturer 38 Operating Manual for XFR 2.8kW Series Power Supply Packaging for Shipping or Storage Follow these instructions to prepare the unit for shipping or storage. 1. When returning the unit or sending it to the service center , attach a tag to the unit stating its model number (available fro m [...]
-
Pagina 41
Inst allation Location, Mounting, and V e ntilation Release 2.1 39 Location, Mounting, and V entilation Use the power supply in rack-mounted or benchtop applications. Rack Mounting The power supply is designed to fit in a standard 19 in. (483 mm) equipment rack. T o install: 1. Use the rack mount brackets at eithe r side of the front panel to insta[...]
-
Pagina 42
Installa tion AC Input Power 40 Operating Manual for XFR 2.8kW Series Power Supply AC Input Power AC Input Connector and V oltage Selection The AC input connector is a 3-terminal wi re clamp located on the power supply’ s rear panel. See Figure 2.2 AC Inp ut Cover and St rain Relief. See T a ble 2.2 for the input voltage ranges and frequ ency req[...]
-
Pagina 43
Inst allation AC Input Power Release 2.1 41 Cord The AC input c ord we recommen d is specified in T able 2.3, “AC W ire Specification”. Add a non-lock ing plug suitable for use in the country in which you are operating. If you require a special cord, call us. T able 2.3 AC Wire S pecification AC Input Wire Connection 1. Strip the outside insula[...]
-
Pagina 44
Installa tion AC Input Power 42 Operating Manual for XFR 2.8kW Series Power Supply Figure 2.2 AC Input Cover and S train Relief Screw-on Locknut S tripped Wire Installed in S train Relief Connector T erminal Locations Cover Assemble d S train Relief Flat W asher (2 places) Lock W asher (2 places) Screw (2 places) Chassis Ground Screw[...]
-
Pagina 45
Inst allation Functional T ests Release 2.1 43 Functional T ests These functional test pro cedures include power -on and front pan el function checks as well as voltage and current mode operation checks. Refer to front and rear panel diagrams in “Front Panel Controls” on page 17 and “Rear Panel Connecto rs and Switch” on page 18. Equipment [...]
-
Pagina 46
Installa tion Functional T ests 44 Operating Manual for XFR 2.8kW Series Power Supply Current Mode Operation Check 1. Ensure the front panel AC power switch is set to OFF . 2. T urn the voltage and current controls on the front panel fu lly counter-clockwise. 3. Connect the DC shunt across the ou tput terminals on the rear panel. 4. Connect the DVM[...]
-
Pagina 47
Inst allation Load Connection Release 2.1 45 Load Connection This section provides recomm endations for load wires an d how to connect them for both single and multiple load configurations. Load Wiring When connecting load wiring to the powe r supply , consider the following factors: • insulation rating of the wire • current carrying capacity o[...]
-
Pagina 48
Installa tion Load Connection 46 Operating Manual for XFR 2.8kW Series Power Supply Load Wiring Length for Oper ation with Sense Lines For applications using remote sensing, you must limit the voltage drop across each load wire. Figure 2.3 shows some m aximum allowa ble wire lengths for a given load current and wire size. W e recommend that you use[...]
-
Pagina 49
Inst allation Load Connection Release 2.1 47 Output Cover The power supply comes with a bus bar cover and strain relief. See Figure 2.4. This cover is also installed on models fitted with the high voltage output connector . T o detach the 2-part cover: 1. Undo 6-32 x 5/16 in. Phillips pan head screws, 6 x 0.28 8 in. lock washers, and 6 x 5/16 in. f[...]
-
Pagina 50
Installa tion Load Connection 48 Operating Manual for XFR 2.8kW Series Power Supply 7.5 V to 100 V Models The 7.5 V to 100 V models ar e equipped with output bus bars. T o make a typical load conn ection to a 7.5 V , 300 A power supply: 1. Strip the ends of the wires. 2. Remove the top part of the output cove r . Do not remove the chassis-mounte d [...]
-
Pagina 51
Inst allation Load Connection Release 2.1 49 150 V to 600 V Models The 150 V to 600 V models have a 4-terminal, wire clamp outp ut connector . See Figure 2.6 for a labelled drawing of the wire clamp connector . T o prepare and connect the load wiring: 1. Strip 0.4 in. (10 mm) at the ends of the wires. 2. Remove the top part o f the output co ver . [...]
-
Pagina 52
Installa tion Load Connection 50 Operating Manual for XFR 2.8kW Series Power Supply Inductive Loads T o prevent damage to the power supply from inductive kickback, connect a diode across the output. The diode must be rated at greater than or eq ual to the supply’ s output voltage and ha ve a current surge ratin g greate r than or eq ual to the su[...]
-
Pagina 53
Inst allation Load Connection Release 2.1 51 Connecting Multiple Loads Proper connection of distribu ted loads is an important as pect of power supply use. T wo common methods of connection are the parallel power distribution m ethod and the radial power distribution method. Parallel Power Distribution This distribution method involves connecting l[...]
-
Pagina 54
Installa tion Load Connection 52 Operating Manual for XFR 2.8kW Series Power Supply Figure 2.10 Multiple Loads wit h Remote Sensing[...]
-
Pagina 55
Inst allation Local and Remote Sensing Release 2.1 53 Local and Remote Sensing Use connections at the rear panel J1 0 sense connector to configure the power supply for local or remote sensing of output vo ltage. See Figure 2.1 1 for a drawing of the sense connector . Sense Wiring For lowest noise performance, use shielded pair wiring of 16 to 24 A [...]
-
Pagina 56
Installa tion Local and Remote Sensing 54 Operating Manual for XFR 2.8kW Series Power Supply . Figure 2.1 1 J10 Sense Conn ector (Shown with local sense jumpers co nnected.) T able 2.5 Rear Panel J10 Sense Connector T erminals and Functions T erminal Name Function J10-1 Return Sense (–SNS) Remote negative sense connection. Default connection to t[...]
-
Pagina 57
Inst allation Local and Remote Sensing Release 2.1 55 Using Remote Sensing Use remote sensing during voltage mode operation to shift the power supply’ s regulation point from its default position at th e rear panel output terminals to the load or distribution terminals by using a separa te pair of wires to allow the control circuitry to monitor t[...]
-
Pagina 58
Installa tion Local and Remote Sensing 56 Operating Manual for XFR 2.8kW Series Power Supply 4. T o prevent ground loops , ground the sens e line shield, at one point only , to the power supply’ s return output connection at the load, to the power supply’ s return output at its negative output terminal , or to the power supply’ s chassis. 5. [...]
-
Pagina 59
Release 2.1 57 Section 3. Local Operation Introduction Once you have installed the power supp ly and have connected bo th the AC input power and the load as covered in S ection 2. Installation, the po wer supply is ready to operate in local control mode (that is, operation at the unit’ s front panel). • See “Standard Operation” on page 57 f[...]
-
Pagina 60
Local Operation Standard Operation 58 Operating Manual for XFR 2.8kW Series Power Supply Figure 3.1 Operating Modes Const ant V oltage Mode Operation The power supply will operate in constant voltage mode whenever the load current I L is less than the current limit setting I SET , or: I L < I SET (Note: I L = V SET / R L ) In constant voltage mo[...]
-
Pagina 61
Local Operation Standard Operation Release 2.1 59 Shipped Configuration (Local Control Mode) The factory ships units already configured for local control (front panel) operation. See T able 3.1 for a summary of this configuration. See Figure 1.1 and Figure for front and rear panel diagrams. T able 3.1 Shipped Configuration (L ocal Control Mode) Loc[...]
-
Pagina 62
Local Operation Standard Operation 60 Operating Manual for XFR 2.8kW Series Power Supply Setting Output V oltage and Current Limit Install the power supply and connect the load as described in Section 2. Installation. Ensure that the power supply is set up fo r local control as described in “ Shipped Configuration (Local Control Mod e)” on page[...]
-
Pagina 63
Local Operation Using Over V oltage Protection (OVP) Release 2.1 61 Using Over V olt age Protection (OVP) The OVP circuit protects the load in the event of a remote programming error , an incorrect voltag e control adjustment, or a power supply failure. The protect ion circuit monitors the output voltage at the output of the power supply and will s[...]
-
Pagina 64
Local Operation Using Over V oltage Protection (OVP) 62 Operating Manual for XFR 2.8kW Series Power Supply Resetting the OVP Circuit T o reset the OV P circuit after it activates: 1. Reduce the power supply’ s output volta ge setting to below the OVP set point. 2. Press the ST ANDBY switch IN. The red S/D LED on the front pa nel turns on. The OVP[...]
-
Pagina 65
Local Operation Using the Shutdown Function Release 2.1 63 Using the Shut down Function Use the Shutdown function to disa ble or enab le the supply’ s output so that you can make adjustments to either the load or the power supply without shutt ing of f the power supply . Activate this function from th e front panel at any time by using the ST AND[...]
-
Pagina 66
Local Operation Using the Shutdown Function 64 Operating Manual for XFR 2.8kW Series Power Supply T able 3.2 Switch Settings for Shut down Circuit L ogic Notes: 1. If switch SW1-7 is ON but there is no si gnal applied, the S/D LED turns on and the power supply will not provide an ou tput until the HIGH signal level i s applied. 2. Any of the eight [...]
-
Pagina 67
Local Operation Using Multiple Supplies Release 2.1 65 Using Multiple Supplies Y ou can operate power supplies of the SAME MODEL with outputs in series or in parallel to obtain increased load voltage or increase d current. Split supply operation gives you two positive outputs or a positive and a negative output. Note:If your application requires th[...]
-
Pagina 68
Local Operation Using Multiple Supplies 66 Operating Manual for XFR 2.8kW Series Power Supply sum of the maximum voltages of each supply (add voltmeter readings, to a maximum of 600 V). The maximum allo wable current for a series string of power supplies is the output current o f a single supply in the string. Figure 3.2 Series Operation of Multipl[...]
-
Pagina 69
Local Operation Using Multiple Supplies Release 2.1 67 Sensing for Parallel Operation Use default local sensing to enhance power sharing between units, as the impedance of the load lines will tend to correct for current imbalance. If you u se remote sensing at the load for better voltage regulation, one supply always operates in current lim it mode[...]
-
Pagina 70
Local Operation Using Multiple Supplies 68 Operating Manual for XFR 2.8kW Series Power Supply T wo Positive V o lt ages T o obtain two positive volta ges, connect the negative output terminals of both supplies together in a common connection. The positive output terminals will provide the required voltages with respect to the common connection. See[...]
-
Pagina 71
Local Operation Using Multiple Supplies Release 2.1 69 Figure 3.5 S plit Supply Operation of Multiple Supplies (Positive-negative Supply) (Local sense lines shown are default J10 connections.)[...]
-
Pagina 72
Local Operation Over T emperature Protection (OTP) 70 Operating Manual for XFR 2.8kW Series Power Supply Over T emperature Protection (OTP) The OTP function allows you to select how the power supply reco vers from an over temperature shutdown using the rear p anel switch SW1-8. See T able 3.3 for switch settings and selections. See “Rear Panel Co[...]
-
Pagina 73
Local Operation User Diagnostics Release 2.1 71 User Diagnostics If your power supp ly is not performing as described in this operating manual, run through the procedures and checks in th is section before calling your service technician. These procedures are confined to operator-level functions onl y and do not require cover-off servicing. Emergen[...]
-
Pagina 74
Local Operation User Diagnostics 72 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 3 . 4 User Diagnostics Symptom Check Further Checks and Corrections No output and the display is blank. Is input voltage within specified range? Connect to appropriate voltage source. See page 40. Power switch ON? T urn on power . Internal circuit? See y[...]
-
Pagina 75
Release 2.1 73 Section 4. Remote Operation Introduction The rear panel switches and connector on th e power supply allow you to program the supply with an analog device or to o utput readback signals. This section covers the following topics: • See “Remote Analog Programming of Output V oltage and Current Limit” on page 74 for information ab [...]
-
Pagina 76
Remote Operation Remote Analog Programming of Output V oltage and Current Limit 74 Operating Manual for XFR 2.8kW Series Power Supply Remote Analog Programming of Ou tput V oltage and Current Limit Remote analog programming allows contro l of the power supply’ s output voltage and/or current limit to shift from local operat ion at the front panel[...]
-
Pagina 77
Remote Operation Remote Analog Programming of Output V oltage and Current Limit Release 2.1 75 4. Connect the program ming source(s) to the mating J2 connector as shown in Figure 4.1, observing the correct polarity for voltage sources. Ensure that the mating connecto r is plugged securely into the rear panel connector . 5. Set the programming sourc[...]
-
Pagina 78
Remote Operation Remote Analog Programming of Output V oltage and Current Limit 76 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 4 . 2 Power Supply Settings for Dif ferent Progra mming Sources Output V olt age Programming Source Output Current Limi t Programming Source 0-5 Vdc 0-10 Vdc 0-5 k Resistor 0-10 k Resistor None (Front Panel [...]
-
Pagina 79
Remote Operation Remote Analog Programming of Output V oltage and Current Limit Release 2.1 77 Figure 4.1 Connecting Programming Sources to J2 Connector[...]
-
Pagina 80
Remote Operation Remote Monitoring of Output V oltage and Current 78 Operating Manual for XFR 2.8kW Series Power Supply Remote Monitoring of Output V olt age and Current Readback Signals The J2 connector on the rear panel provid es access to calibrated readback signals for remote monitoring of the ou tput voltage and current. Rear panel switch es S[...]
-
Pagina 81
Release 2.1 79 Section 5. Calibration Introduction Adjustments to programming and readback accuracy for the power supply are made using cover-of f procedures which must be performed by a service technician. Calibration Setup Service Environment and Precautions • Follow established antistatic procedures. • W ork at a bench with adequate room and[...]
-
Pagina 82
Calibration Calibration Setup 80 Operating Manual for XFR 2.8kW Series Power Supply Accessing Calibration Potentiome ters Y ou will need to remove the power supply ’ s cover to access the programming and readback calibration potentiometers wh ich are located on the A2 PCB. See Figure 5.1 to locate the potentiometers. W ARNING Disconnect AC power [...]
-
Pagina 83
Calibration Calibration Setup Release 2.1 81 Removing Option Card If there is a GPIB or RS-232 option card (PCB) installed inside the power supply , you will have to remove it to access the calibration potentiometers. T ool Required: Phillips #2 screwdriver 1. T urn OFF the power supply . Disconn ect AC Power . Remove the cover . 2. Remove 4 screws[...]
-
Pagina 84
Calibration Calibrating for Programming Accurac y 82 Operating Manual for XFR 2.8kW Series Power Supply Calibrating for Programming Accuracy The factory calibrates the offset and rang e of the voltage and current programming circuits to within 1% for the default 0- 10 Vdc progra mming signals. Y ou may n eed to recalibrate when you use 0-5 Vdc pr o[...]
-
Pagina 85
Calibration Calibrating for Programming Accuracy Release 2.1 83 Current Limit Programming Circuit Calibration 1. Ensure that the power supply is turned OFF . Disc onnect any load. 2. Connect the program source between J2 connector terminals 8 (output current limit programming input) and 7 (c urrent program signal return). 3. Connect the shunt an d [...]
-
Pagina 86
Calibration Calibrating for Readback A ccuracy 84 Operating Manual for XFR 2.8kW Series Power Supply Calibrating for Readback Accuracy The factory calib rates the of fset and ra nge of the output voltage and current monitor circuits to within 1% for the default 0- 10 Vdc scales. Y ou may need to recalibrate when you select the 0-5 Vdc scale or when[...]
-
Pagina 87
Calibration Calibrating for Readback Accuracy Release 2.1 85 Output Current Monitor Circuit Calibration 1. Ensure that the power supply is turned OFF . Disc onnect any load. 2. Set SW1 switch 6 OPEN to select 0-5 V output current monitor range, CLOSED for 0-10 V . 3. Connect the shunt and DVM across the po wer supply output to read the output curre[...]
-
Pagina 88
Calibration Calibrating for Readback A ccuracy 86 Operating Manual for XFR 2.8kW Series Power Supply[...]
-
Pagina 89
[...]
-
Pagina 90