Vai alla pagina of
Manuali d’uso simili
-
Marine Battery
Xantrex Technology 450
40 pagine 1.83 mb -
Marine Battery
Xantrex Technology 806-1840-02
54 pagine 3.69 mb -
Marine Battery
Xantrex Technology 175
37 pagine 0.23 mb -
Marine Battery
Xantrex Technology 1000
88 pagine 2.69 mb -
Marine Battery
Xantrex Technology 806-1055-02 806-1840
54 pagine 3.69 mb -
Marine Battery
Xantrex Technology SW 1000
38 pagine 1.09 mb -
Marine Battery
Xantrex Technology 975-0558-01-01 i
38 pagine 1.17 mb -
Marine Battery
Xantrex Technology Freedom SW 2000
60 pagine 3.54 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Xantrex Technology XM 1800. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Xantrex Technology XM 1800 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Xantrex Technology XM 1800 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Xantrex Technology XM 1800 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Xantrex Technology XM 1800
- nome del fabbricante e anno di fabbricazione Xantrex Technology XM 1800
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Xantrex Technology XM 1800
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Xantrex Technology XM 1800 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Xantrex Technology XM 1800 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Xantrex Technology in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Xantrex Technology XM 1800, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Xantrex Technology XM 1800, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Xantrex Technology XM 1800. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
by Xantrex PRO Inverter XM 1000 and XM 1800 Owner's Guide 975-0263-01-01 REV . C Printed in China t 1-800-670-0707 (toll-free in North America) 1-360-925-5097 (direct) f 1-360-925-5143 (direct) e CustomerService@xantrex.com www .xantrex.com[...]
-
Pagina 2
Xantrex PRO Inverter Owner’s Guide Xantrex_PRO1800.book Page i Tu esday, April 24, 2007 11: 33 AM[...]
-
Pagina 3
About Xantrex Xantrex T echnology Inc. is a worl d-le ading supplier of advanced power electroni cs and controls with products from 50 watt mobile units to 1 MW utility -scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applicati ons in bo th grid-connected and st and-alone systems. Xantrex products include inver[...]
-
Pagina 4
iii About This Guide Purpose The purpose of this Owner ’ s Guide is to provide explanations and procedures for installing, operating, and maintaining the Xantrex PRO Inverter (XM 1800 and XM 1000). Scope The Guide provides safety guidelin es, detai led planning and setup information, procedures for installing the inverter , as well as information[...]
-
Pagina 5
About T his Guide iv 975-0263-01-01 Conventions Used The following co nventions are used in this guide. Related Information Y ou can find more information about Xantrex T echnology Inc. and its products and servi ces at www .xantrex.com . WA R N I N G W arnings iden tify conditions that could result in personal inj ury or loss of life CA UTION Caut[...]
-
Pagina 6
v Important Safety Instructions 1. Before installing and using the Xantrex PRO Inverter (XM 1800 or XM 1000), read all instructions and cautionary markings on the inverter , the batteries , and all appropriate sections of this guide. 2. Do not expo se the Xantrex PRO Inverter to rain, snow , or spray . T o reduce risk of fire hazard, do no t cover [...]
-
Pagina 7
Safety vi 975-0263-01-01 Explosive Gas Precautions 1. W orking in the vicinity of lead-a cid batteries is dange rous. Batteries generate explosive gases during normal operation . Therefore, you must read this guide and follow the instructions exactly before installing or u sing your Xantrex PRO Invert er. 2. This equipment conta ins components that[...]
-
Pagina 8
Safety 975-0263-01-01 vii Precautions W hen W orking W ith Batteries 1. Follow all instructions publi shed by the battery manufacturer and the manufacturer of the equipment in which the battery is installed. 2. Make sure the area around the battery is well ventilated. 3. Never smoke or allow a spark or flame near the engine or batteries. 4. Use cau[...]
-
Pagina 9
Safety viii 975-0263-01-01 Precautions for Using Rechar geable Appliances Most rechargeable battery-operated equipment uses a separate char ger or transformer that is plugged into an AC receptacle and produces a low voltage charging output. Some chargers for small rechar geable batteries can be damaged if connected to the Xantrex PRO Inverter . Do [...]
-
Pagina 10
975-0263-01-01 ix Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v 1 Introduction Quality Power - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–1 Comprehensive Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - [...]
-
Pagina 11
Contents x 975-0263-01-01 Connecting the DC Cables - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–22 Testing Your Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–24 Testing in Invert Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3?[...]
-
Pagina 12
Contents 975-0263-01-01 xi A Specifications Electrical Performance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–1 Physical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–2 Mounting Dimensions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -[...]
-
Pagina 13
xii Xantrex_PRO1800.book Page xii Tuesday, April 24, 2007 11:3 3 AM[...]
-
Pagina 14
1–1 1 Introduction Congratulations on your purchase of the Xantrex PRO Inverter (XM 1800 or XM 1000). The XM 1800 has been designed to give you quality power , ease of use, and reliability . Please take a few moments to read th is chapter to familiarize yourself with the main performance features and protection features of the XM 1800. Quality P [...]
-
Pagina 15
Introduction 1–2 975-0263-01-01 Comprehensive Pr otection The XM 1800 is equi pped with numero us protection features to guarantee safe and trouble-free operation: Low battery alarm Alerts you if the battery has become discharged to 1 1.0 V or lower . Low battery voltage shutdown Shuts the XM 1800 down automatically if the battery voltage drops b[...]
-
Pagina 16
2–1 2 F eatures Chapter 2 describes the main features of the XM 1800. Xantrex recommends that you familiari ze yourself with these features before installing and op erating the inverter . Materials List Y our XM 1800 package includes: • One XM 1800 inverter • T wo M8 lock washers (on the DC input cable terminals) • T wo M8 nuts (on the DC i[...]
-
Pagina 17
Fe a t u r e s 2–2 975-0263-01-01 Front P anel Side V iew Feature Description 1 Detachable remote panel to display inv erter status and battery status info rmation. Fo r more information about the remote panel, see “Front Panel Operation” on page 4–2. 2 GFCI receptacles provide 1000 W (XM 1000) or 1800 W (XM 1800) of power to o perate AC de[...]
-
Pagina 18
Rear P anel 975-0263-01-01 2–3 Rear P anel Feature Description 1 Negative DC cabling terminal connects to the cable connected to the negative terminal of the battery . 2 V entilation opening must not be obstructed for the proper operation o f the cooling fan and inverter . When the inv erter is mounted, the ventilation open ing must not point up [...]
-
Pagina 19
2–4 Xantrex_PRO1800.book Page 4 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 20
3–1 3 Installation Chapter 3 provides information on ca bles and fuses to help you plan for your installation, and provides procedures for installing the XM 18 00. Xantrex strongly recommends that you read the entire chapter before starting to install the XM 1800, so that you can plan an installation that is suited to your power needs. Designing [...]
-
Pagina 21
Installation 3–2 975-0263-01-01 Figure 3-1 DC Input Configuration for Normal Loads GROUND TO VEHICLE CHASSIS DISCONNECT SWITCH FUSE OR CIRCUIT BREAKER DEEP-CYCLE AUXILIARY BATTERY DEEP-CYCLE AUXILIARY BATTERY GROUND TO VEHICLE CHASSIS VEHICLE STARTING BATTERY GROUND TO VEHICLE CHASSIS TO VEHICLE TO DC LOADS ISOLATOR FROM ALTERNATOR CHARGER FUSE O[...]
-
Pagina 22
Designing Y our Installation 975-0263-01-01 3–3 Figure 3-2 DC Input Configuration for Heavy Loads GROUND TO VEHICLE CHASSIS GROUND TO VEHICLE CHASSIS TO VEHICLE BATTERY ISOLATOR FROM ALTERNATOR CHARGER GROUND TO VEHICLE CHASSIS VEHICLE STARTING BATTERY DISCONNECT/ BATTERY SELECTOR SWITCH DEEP-CYCLE BATTERY DEEP-CYCLE BATTERY DEEP-CYCLE BATTERY DE[...]
-
Pagina 23
Installation 3–4 975-0263-01-01 Installation Codes Governing installatio n codes vary depending on th e location and type of installation. Electrical installations must meet local and national wiring codes and should be performed by a qualified electricia n. In residential applications, electri cal codes do not allow permanent connection of AC di[...]
-
Pagina 24
Designing Y our Installation 975-0263-01-01 3–5 Choosing an Appropriate Location The XM 1800 must only be in stalled in a location that is: : W ARNING: Explosion or fire hazar d The XM 1800 contain s components that may produce arcs or sparks. T o prevent fire or explosion, do not install the inverter in compartment s containing batteries or flam[...]
-
Pagina 25
Installation 3–6 975-0263-01-01 Calculating Cable Sizes T o operate safe ly and effectively , th e XM 18 00 needs proper cable s and fuses. Because the XM 1800 has low-vo ltage and high-current input, it is essential that you use low-resistance wiring between the ba ttery and the inverter to deliver the maximum amoun t of usable ener gy to your l[...]
-
Pagina 26
Designing Y our Installation 975-0263-01-01 3–7 Sizing the Chassis Ground Cable See T able 3-2 for the size of the chass is ground cable that runs from the grounding poi nt to the chassis groun d stud on the inverter . T able 3-1 Recommended DC Input Wire Sizes & Lengths RV a (Recr eational V ehicle) a. Based on US National Electric al Code N[...]
-
Pagina 27
Installation 3–8 975-0263-01-01 Calculating Fuse/Circuit Br eaker Size Because your batteries can provide thousands of am ps of short-circuit current, you need fu ses or circuit brea kers that can safely interrupt the short-circuit current that the batteries can produce. T o select the corr ect fuse type and size: 1. Determine the total short-cir[...]
-
Pagina 28
Installing the XM 1800 975-0263-01-01 3–9 Installing the XM 1800 Do not proceed with the installation of your XM 1800 until you have read the section “Designing Y our Installati on” on page 3–1. The more thorough your plann ing, the better your power needs will be met to achieve maximum performance from yo ur XM 1800. Safety Instructions Be[...]
-
Pagina 29
Installation 3–10 975-0263-01-01 Materials The following checklist is a general list of required materials. ❐ Four corrosion-resistant fasteners sized #10 (M4.5) for mounting the inverter ❐ Copper DC input cable as calculated in T able 3-1 on page 3–7 ❐ T wo 3/8 inch (M8) ring terminals sized for the cable diameter to connect the DC cable[...]
-
Pagina 30
Installing the XM 1800 975-0263-01-01 3–11 Overview of Installation Steps Installing the XM 1800 in cludes the following steps. 1. Ensure that AC and DC power is off. 2. Mount the i nverter 3. Connect the chassis ground 4. Connect AC input (if connec ti ng to an existing AC circuit) 5. Connect AC output (if connec ting to an existing AC circuit) [...]
-
Pagina 31
Installation 3–12 975-0263-01-01 Connecting the Chassis Ground The XM 1800 has a ground stud on the side of the unit a s shown in Figure 3-3. Follow the guidelines in “Gro unding Locations” to connect the inverter ’ s chassis to the ground. Grounding Locations Y ou must connect the chassis ground stu d to a grounding point—usually the veh[...]
-
Pagina 32
Installing the XM 1800 975-0263-01-01 3–13 Chassis Ground Stud Xantrex recommends that you attach the grounding cable to the chassis ground stud with a ring terminal. This procedure will ensure that the wire does not slip off the chassis ground stud. T o connect the cable to the chassis gr ound stud: 1. Remove the ground stud nut and star washer [...]
-
Pagina 33
Installation 3–14 975-0263-01-01 AC W i r i n g Y ou can plug loads (12 A continuous, 15 A maximum) directly in to the GFCI receptacle on the front panel of the XM 1800. Y ou can also connect the inverter to an existing AC circ uit and then plug loads into GFCI receptacles connecte d to that circuit. If you plan to use the XM 1800 with the GFCI a[...]
-
Pagina 34
AC W i ri ng 975-0263-01-01 3–15 When making the AC input and AC output connections, observe the correct color code for the appropriate AC wire, as described in T able 3-4. Connecting A C Input 1. Install the required circuit breake r in the AC output panel supplying the unit (See Figure 3-6 on page 3–20). 2. Ensure AC power is disconne cted fr[...]
-
Pagina 35
Installation 3–16 975-0263-01-01 A separat e screw is pro vided to c onnect the AC input ground (see Figure 3-5 on page 3–16 ). 8. Strip about 2 inches (50 mm) from th e jacket of the AC input cable. The AC input cable may be either solid or stranded, but must have three conductors and be sized as in T able 3-3 on page 3–14. (The AC terminal [...]
-
Pagina 36
AC W i ri ng 975-0263-01-01 3–17 15. Secure the strain-relief clamp. 16. See “Connecting AC Output to an Existing AC Circu it” on page 3–17. 17. Reinstall the GFCI to the unit. Alternatively , if you do not reinsta ll the GFCI, make sure that you cap the exposed wires and install a blanking plate to cover the space vacated by the GFCI. Conn[...]
-
Pagina 37
Installation 3–18 975-0263-01-01 T o make a permanent connecti on to existing AC wiring: 1. Install the required circuit breaker in the AC load panel (see Figure 3-6 on page 3–20 an d Figure 3-7 on page 3–21). 2. Ensure AC power is turned off. 3. Remove the left-h and side AC wiring knocko ut from the front of the unit. 4. Install a supplied [...]
-
Pagina 38
AC W i ri ng 975-0263-01-01 3–19 1 1. Insert the Line and Neutral wires into the corresponding terminals. 12. T ighten the wire attachment screws to a torque of 1.3–1.8 lbf-ft (1.76– 2.44 Nm). Leav e some wirin g slack ins ide the wiri ng compartme nt. Ensure you have maintai ned correct po larity and that there are no loose strands of wire. [...]
-
Pagina 39
Installation 3–20 975-0263-01-01 In this wiring diagram, the AC inpu t comes from the main AC panel which acts as the circuit breaker from an AC source. The output is routed to a separate circuit breaker acting as the inverter AC subpanel. Figure 3-6 AC W iring Diagram with an Inverter Subpanel GENERATOR SHORE POWER TO DC LOADS A C I N A C O U T [...]
-
Pagina 40
AC W i ri ng 975-0263-01-01 3–21 In this wiring diagram, the AC input comes directly from an AC source. The AC input must be limited with (inp ut) breaker protection of 15 am ps for the XM1000 and 20 amps for the XM1800. The output is ro uted to the main AC panel or circuit breaker . Figure 3-7 AC Wiring Diagram without an Inverter Subpanel GENER[...]
-
Pagina 41
Installation 3–22 975-0263-01-01 Connecting the DC Cables Consult Figure 3-1, “DC I nput Configuration for No rmal Loads” on page 3– 2, or , Fig ure 3-2, “DC Input Configuration for Heav y Loads” on page 3–3, for additional details that are specific to your installation. T o connect the DC cable s: 1. Make sure the inverter is off a n[...]
-
Pagina 42
Connecting the DC Cables 975-0263-01-01 3–23 10. Attach the connector on the positive cable to th e positive DC terminal on the inverter . 1 1. Install the lock washer and nut that are supplied with the inverter . T ighten the nut to a torque of 108–120 in-lb f (12.2–13.6 N-m). Make the connectio n snug enough so the ring terminal does not mo[...]
-
Pagina 43
Installation 3–24 975-0263-01-01 14. Install the lock washer and nut that are supplied. T ighten the nut to a torque of 108–120 in-lbf (12.2 –13.6 N-m). Make the connection snug enough so the ring term inal does not move around on the DC terminal, but do not overtighten. 15. Slip the DC terminal covers over the XM 1800 DC terminals. 16. Use t[...]
-
Pagina 44
T est ing Y our Installation 975-0263-01-01 3–25 4. T u rn the appliance on to verify that it operates. If the appliance operates, your installa tion is successful. If your installation has AC input and output hard wired to the XM 1800, proceed to “T esting in Shore Power Mode”. If the status LED on the displa y panel glows red, see the Troub[...]
-
Pagina 45
Installation 3–26 975-0263-01-01 Installing the Remote P anel Y ou can detach a nd reinstall the remo te panel to monitor and operate the XM 1800 up to 25 feet (7.62 m) away from the unit. T o install the remote panel in another location, you will need the following tools and materials: • screwdriver • jigsaw • drill (optional) • RJ1 1 ex[...]
-
Pagina 46
Installing the Remote P anel 975-0263-01-01 3–27 5. Using a jigsaw or other suitable tool, make a hole in the wall or bulkhead into which to insert the remote panel. The hole sh ould measu re 3 1/4 in ch es (83 mm) across by 1 1/3 inches (33 mm) high, with at least 1 1/2 in ches (40 mm) of depth to allow space for the remote panel cord to bend. 6[...]
-
Pagina 47
3–28 Xantrex_PRO1800.book Page 28 Tu esday, April 24, 2007 11 :33 AM[...]
-
Pagina 48
4–1 4 Oper ation Chapter 4 explains how to operate the XM 1800 efficiently and effectively . Specifically , this chapter: • Gives procedures for operating the inverter from the remote panel • Discusses operating limits and inverter loads • Discusses battery charging frequency • Provides information ab out routine maintenance. Xantrex_PRO1[...]
-
Pagina 49
Operation 4–2 975-0263-01-01 Front P anel Operation The XM 1800 features a re mote co ntrol panel with three-digit LED display to show inverte r , AC source, and battery status informatio n. Figure 4-1 XM 1800 Remote P anel T able 4-1 Remote P anel F eatures Featur e Description 1 On/Off butt on . Press once to turn the XM 1800 on or off. 2 Three[...]
-
Pagina 50
Operating in Shore P ower Mode 975-0263-01-01 4–3 Operating in Shor e P ower Mode The XM 1800 is in shore power mode when an AC source (a generator or utility power) is present to power th e appliances connec ted to the XM 1800. The status LED glows green t o indicate that the XM 1800 is using utility (or generator) power . The inverter draws min[...]
-
Pagina 51
Operation 4–4 975-0263-01-01 Checking Battery Status Y ou can check the battery status by pressing the Select button until the Input V oltage LED illuminates. The batt ery voltage appears in the three- digit LED display . The normal op erating battery v oltage range is between 1 1 and 15 volts. Checking Output P ower Y ou can check how much power[...]
-
Pagina 52
Operating Limits 975-0263-01-01 4–5 Operating Limits P ower Output The XM 1800 can deliver up to 1000 watts (XM 1000) or 1800 watts (XM 1800) continuous power . The wa ttage rating applies to resistive loads such as incandescent lights. Input V oltage The allowable XM 1 800 input voltage ranges are shown in the following table: Operating Conditio[...]
-
Pagina 53
Operation 4–6 975-0263-01-01 Inverter Loads The XM 1800 will operate most AC lo ads within its power rating of 1000 watts (XM 1000) or 1800 watts (XM 1800). However , some appliances and equipment may be difficult to operate, and other applia nces may actually be damaged if you try to op erate the m with the XM 1800. Please read “High Surge Loa[...]
-
Pagina 54
Over -t emperature Conditions 975-0263-01-01 4–7 Over -temperatur e Conditions When the XM 1800 senses its internal temperature approaching its limit, the alarm beeps every two seconds an d the display shows fault code E07 alternating with “OtA”. If the over -temperature condition persists, the XM 1800 shuts down to protect itself. The alarm [...]
-
Pagina 55
4–8 Xantrex_PRO1800.book Page 8 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 56
5–1 5 T roubleshooting Chapter 5 will help you identify the source of most problems that can occur with the XM 1800. If you experience a problem with the inve rter that is not described in this chapter , plea se visit www .xantrex.com/support.asp and ch eck the F AQs (Frequently Asked Questions) for your p roduct. Please review this chapter befor[...]
-
Pagina 57
T roublesho oting 5–2 975-0263-01-01 Common Problems Buzz in Audio Equipment Some inexpensive stereo systems may emit a buzzing noise from their loudspeakers when op erated from the XM 1800. This occurs becaus e the power supply in the audio system does not adequately filter the modified sine wave produced by the inverter . The only solution is t[...]
-
Pagina 58
Understanding F ault Codes 975-0263-01-01 5–3 T able 5-1 Fa u l t C o d e s Fa u l t Code Status LED Description Solution E01 Y ellow Under-voltage warning Check the connections and cable to see if the battery is fully charged. Rechar ge the battery if it is low . Reduce the load. E02 Red Under-voltage shutdown Disconnect the load and recharge th[...]
-
Pagina 59
T roublesho oting 5–4 975-0263-01-01 T roubleshooting Refer ence W ARNING: Electrical shock and burn hazar d Do not disassemble the XM 1800. It does not contai n any user-serviceable parts. Attempting to service th e unit yourself could result in an electri cal shock or burn. T able 5-2 T roubleshooting Reference Problem P ossible Cause Solution [...]
-
Pagina 60
T roubleshooting Reference 975-0263-01-01 5–5 No output voltage. The stat us LED is red. Low input voltage (fault code E02) High input voltage (fault code E03) Thermal shutdown (fault code E08) Unit overload (fault code E05) Unit has a short-circuited output (fault code E05). Recharge the battery; check the connections and cable. Make sure the XM[...]
-
Pagina 61
5–6 Xantrex_PRO1800.book Page 6 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 62
A–1 A Specifications Appendix A contains electrical perform ance and physical specifications for the XM 1000 an d XM 1800. Specifications are subject to change w ithout notice. Electrical P erformance XM 1000 XM 1800 Output power at 77 º F (25 ºC) ambient temperature and 12 VDC input: • Maxim um continuous outpu t power •5 m i n u t e s 100[...]
-
Pagina 63
Specifications A–2 975-0263-01-01 Physical Specifications XM 1000 XM 1800 Length 12 13/16 inches (326 m m) 14 9/16 inches (370 mm) W id th (including mounting flanges) 9 inches (230 mm) Height 4 inches (102 mm) W eight 7.5 lb (3.4 kg) 10.8 lb (4.9 kg) Xantrex_PRO1800.book Page 2 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 64
Mounting Dimensions 975-0263-01-01 A–3 Mounting Dimensions Figure A-1 XM 1800 Mounting Dimensions Xantrex_PRO1800.book Page 3 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 65
Specifications A–4 975-0263-01-01 Figure A-2 XM 1000 Mounting Dimensions Xantrex_PRO1800.book Page 4 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 66
B–1 B Battery T y pes The information in Chapter B will help you to select, conn ect, and maintain batteries that are most appropriate for your application. The batteries that you use strongly af fect the performance of the XM 1800. It is important to co nnect the inverter to the correct size and type of battery . Battery T ypes Automotive Starti[...]
-
Pagina 67
Battery T y pes B–2 975-0263-01-01 Deep-Cycle Batteries Deep-cycle batteries are de signed fo r deep discharge service where they will be repeatedly dischar ged and rechar ged. They are marketed for use in recreational vehicles, boats, and elect ric golf carts—so you may see them referred to as R V batteries, marine batteries, or golf cart batt[...]
-
Pagina 68
Battery Size 975-0263-01-01 B–3 Battery Reserve Capacity Battery reserve capacity is a measure of how long a battery ca n deliver a certain amount of current—usually 25 amps. For example, a battery with a reserve capacity of 180 minutes can deliver 25 amps for 180 minutes before it is comp letely discharged. Amp-hour (Ah) Capacity Amp-hour capa[...]
-
Pagina 69
Battery T y pes B–4 975-0263-01-01 Estimating Battery Requirements T o determine how much battery capacity you need: 1. Determine how many watts are cons umed by each ap pliance that you will operate from the XM 1800. Y ou ca n normally find the watt rating labelled on the product. If only the current draw i s given, multiply it by 1 15 to get th[...]
-
Pagina 70
Estimating Battery Requirements 975-0263-01-01 B–5 This example illustrates how quickly your battery needs can escalate. T o reduce the required battery size, you can cons erve energy by eliminating or reducing the use of some lo ads or by re-char g ing more frequently . When sizing your battery , resist the temp tation to skip the last step of t[...]
-
Pagina 71
Battery T y pes B–6 975-0263-01-01 Using Multiple Batteries As your power requirements incre ase, you may need to use more than one battery to obtain suf fic ient capacity . Read “T wo Batteries Connected In Parallel” and “T wo Separate Battery Banks” to determine whether two batteries or two battery banks are more appropriate for you r a[...]
-
Pagina 72
Battery T ips 975-0263-01-01 B–7 Battery Tips Explosive/ Corrosive Gases Lead-acid batteries may emit hydrogen gases, oxygen, and sulfuric acid fumes when recharging. T o re duce the risk of explosion : • V ent the battery compartment to prevent the accumulation of gases. • Do not install electronic or electrical equipment in the battery comp[...]
-
Pagina 73
Battery T y pes B–8 975-0263-01-01 Battery Connections Connections to battery posts must be made with permanent connectors that provide a reliable, low-resistance connection. Do not use alligator clips. Clean the connections regularly and prevent corro sion by using a protective spray coating or V aseline. Battery State of Char ge Y ou can measur[...]
-
Pagina 74
C–1 C Alternators and Char ging Systems Appendix C provides gu idelines for rechar ging batteries from an alternator , from AC power , and from alternate ener gy sources. A good charg ing system is important fo r the health of your batteries. Poor recharging methods can quickly damage batteries. Charging System Requir ements Y our charging system[...]
-
Pagina 75
Alternators and Charging Systems C–2 975-0263-01-01 Charging W ith an Engine Alternator Read the following inform ation to determine whether your vehi cle’ s standard alternator will be adequate by itself, whether you should install an alternator controller , or whether you need a high-output alternator . Using a Standard V ehicle Alternator A [...]
-
Pagina 76
Charging F rom AC P ower 975-0263-01-01 C–3 Charging Fr om AC P ower When recharging from AC power , use a good quality battery charger or R V converter that meets the requirem ents outlined in “Charging System Requirements” on page C–1. For information about Xant rex’ s battery chargers, visit our web site at www .xantrex.com . Do not us[...]
-
Pagina 77
C–4 Xantrex_PRO1800.book Page 4 Tuesd ay, April 24, 2007 11:33 AM[...]
-
Pagina 78
975-0263-01-01 WA–1 W arranty and Return Information Wa r r a n t y What does this warranty cover? This Limited W arranty is provided by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your Xantrex PRO Inverter (XM 1800 or XM 1000). This warranty period lasts for 1 year from the date of purchase at th[...]
-
Pagina 79
W arranty and Return WA–2 975-0263-01-01 What does this warranty not cover? This Limit ed W arranty does not cover norm al wear and tear of the product or costs related to the removal, install ation, or troubleshooting of the customer's electrical systems. This warranty does not appl y to and Xant rex will not be responsible for any defect i[...]
-
Pagina 80
W arranty and Return 975-0263-01-01 WA–3 W arning: Limitations On Use Please note that the Xantrex PRO Inverter is not inte nded for use as an uninterruptibl e power supply and Xantrex makes no w arranty or re presen tation in connection with any use of the product for such purposes. Return Material Authorization P olicy Before returning a produc[...]
-
Pagina 81
W arranty and Return WA–4 975-0263-01-01 Out of W arranty Service If the warranty period for your X antrex PRO Inverter has expired, if the unit was dam aged by misuse or incorrect installation, if other conditio ns of the warranty have not been met, or if no dated proof of purchase is available, your inverter may be serviced or replaced for a fl[...]