Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Xantrex 3000 manuale d’uso - BKManuals

Xantrex 3000 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Xantrex 3000. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Xantrex 3000 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Xantrex 3000 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Xantrex 3000 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Xantrex 3000
- nome del fabbricante e anno di fabbricazione Xantrex 3000
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Xantrex 3000
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Xantrex 3000 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Xantrex 3000 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Xantrex in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Xantrex 3000, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Xantrex 3000, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Xantrex 3000. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    by XPower Inverter 3000 Plus Owner’s Guide XPower3000.book Page i Wednesday, Decemb er 10, 2003 6:52 AM[...]

  • Pagina 2

    About Xantrex Xantrex T echnology Inc. is a worl d-leadi ng supplier of advanced power electroni cs and controls with products from 50 watt mobile units to one MW utility-s cale systems fo r wind, solar , batteries, fuel cells, microturbines, and backup power app lications in bo th grid-connect ed and stand-alone systems. Xantrex products include i[...]

  • Pagina 3

    iii About This Guide Purpose The purpose of this Owner ’ s Guide is to provide explanations and procedures for installing, operating, maintaining, and troubleshooting the XPower Inverter 3000 Plus. Scope The Guide provides safety guidelin es, detai led planning and setup information, procedures for installing the inverter , as well as information[...]

  • Pagina 4

    About T his Guid e iv 975-0128-01-01 Conventions Used The following conventions are used in this gui de. Related Information Y ou can find more information about Xantrex T echnology Inc. as well as its products and services at www .xantrex.com WA R N I N G W arnings iden tify conditions that could result in personal inj ury or loss of life CA UTION[...]

  • Pagina 5

    v Important Safety Instructions 1. Before installing and using the XPower Inverter 3000 Plus, read all instructions an d cautionary mark ings on the XPower Inverter 30 00 Plus, the batteries, an d all appropriate sections of this guide. 2. Do not expose th e XPower Inverter 30 00 Plus to rain, snow , sp ray , or bilge water . T o reduce risk of fir[...]

  • Pagina 6

    Safety vi 975-0128-01-01 Explosive gas pr ecautions 1. W orking in the vicinity of lead-a cid batteries is dangerous. Batteries generate explosive gases during norma l operation. Therefore, you must read this guide and follow the instructions exactly before installing or using your XPower Inverter 3000 Plus. 2. This equipment conta ins components w[...]

  • Pagina 7

    Safety 975-0128-01-01 vii 5. Remove all metal items, like ring s, bracelets, and watches when working with lead-acid batteries. Lead-acid batteries produc e a short circuit current h igh enough to weld metal to skin, causing a severe burn. 6. Have someone wit hin range of you r voice or close enough to come to your aid when you work near a lead-aci[...]

  • Pagina 8

    viii XPower3000.book Page viii Wednesday, December 10, 2003 6:52 A M[...]

  • Pagina 9

    975-0128-01-01 ix Important Safety Instructions Explosive gas precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vi Precautions When Working With Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vi Precautions for Using Rechargeable Appliances - - - - - - - - - - - - - - - - - - - - - - [...]

  • Pagina 10

    Contents x 975-0128-01-01 Installing the Remote On/Off Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–9 Mounting the Inverter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–10 AC Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–11 Connecting [...]

  • Pagina 11

    Contents 975-0128-01-01 xi B Battery Types Battery Types - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–1 Automotive Starting Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–1 Deep-Cycle Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - [...]

  • Pagina 12

    xii XPower3000.book Page xii Wednesday, December 10, 2003 6:52 AM[...]

  • Pagina 13

    1–1 1 Intr oduction The XPower Inverter 3000 P lus has been designed to give you quality power , ease of use, and reliability . Please take a few moments to read th is chapter to familiarize yourself with the main performance features and protection features. Quality P ower The XPower Inverte r 3000 Plus is designed for use in recreational vehicl[...]

  • Pagina 14

    Introduction 1–2 975-0128-01-01 Ease of Use Superior features and rugged durability have been combined with ease of use: • The inverter is compact, lig htweight, and easy to install. • Loads can be po wered directly from the AC outlets. • Easy-to-read indicators on the fro nt panel let y ou monitor system performance at a glance. • Remote[...]

  • Pagina 15

    2–1 2 F eatures Chapter 2, “Features” describes the main features of the XPow er Inverter 3000 Plus. Familiarize yourself with them before insta lling and operating the inverter . Remote On/Off Switch The Remot e On/Off switch can b e plugged into the remote switch connector port on the fro nt of the inve rter . The remote switch lets you tur[...]

  • Pagina 16

    Fe a t u r e s 2–2 975-0128-01-01 AC P a n e l Figure 2-2 AC P a ne l Feature D escription 1 On/Off Switch turn s the invert er ’ s control circuit on and o ff. This switch is not a power disco nnect switch. Disconnect AC and DC power bef ore workin g on any ci rc uits connected to the inverter . 2 Fault lig ht (red): indicates the inverter has[...]

  • Pagina 17

    AC P an e l 975-0128-01-01 2–3 6 S tatus D isplay: Shows V oltage, Current or AC Power . VO L T A G E : Indicates battery power at the input terminal of the inverter in volts (V). CURRENT : Indicates current drawn from the battery by the inverter in amps (A). AC POWER: Indicate s the output pow er from the inverter as a percentage of total availa[...]

  • Pagina 18

    Fe a t u r e s 2–4 975-0128-01-01 DC P anel Figure 2-3 DC P anel Fea t u re D es c r ip t i on 1 Chassis Ground Lug connects to vehicle chassis, D C grounding bus or to engine’ s negati ve bus. 2 V entilation Opening must not be obstructed for the proper operation of the inverter . When the inverter is mounted, the ventilation opening on the DC[...]

  • Pagina 19

    3–1 3 Installation Chapter 3, “Installation,” provides info rmation on cables and fuses to help you plan for your installation and pr ovide procedures for i n stalling the inverter. Read the entire chapter before begi nning the installation procedures so that you can plan an installation th at is suited to your power needs. Designing Y our In[...]

  • Pagina 20

    Installation 3–2 975-0128-01-01 Figure 3-1 Configuration for Normal Loads Figure 3-2 Configuration for Heavy Loads XPower3000.book Page 2 Wed nesday, December 10, 2003 6:52 AM[...]

  • Pagina 21

    Designing Y our Installation 975-0128-01-01 3–3 Installation Codes Governing installatio n codes vary depending on the location and type of installation. Electrical installations must meet local and national wiring codes and should be performed by a qualified electric ian. In residential applications, electri cal codes do not allow permanent conn[...]

  • Pagina 22

    Installation 3–4 975-0128-01-01 Choosing an Appropriate Location The inverter must only be in stalled in a location that is: : WA R N I N G The inverter contains comp onents that tend to produce arcs or sparks. T o prevent fire or explosion, do not install the inverter in compartments containin g batteries or flammable materials, or in locations [...]

  • Pagina 23

    Designing Y our Installation 975-0128-01-01 3–5 Calculating Cable Sizes T o operate safely and effectively , the XPower Inverter 3000 Plus needs proper cables and fuses. Because the XPower Inverter 3000 Plus has low- voltage and high-current input, it is essential that you use low-resistance wiring between the battery and the inverter to del iver[...]

  • Pagina 24

    Installation 3–6 975-0128-01-01 Calculating Size of Chassis Ground Cable Refer to T able 3-2 to plan the size of the chassis ground cable that runs from the DC grounding point to the chass is gro und screw on the inverter ’ s DC panel. T able 3-1 Recommended DC Input Wire Sizes & Lengths RV (Recreational V ehicle) Cable length: Battery to I[...]

  • Pagina 25

    Designing Y our Installation 975-0128-01-01 3–7 Calculating Fuse/Circuit Br eaker Size Because your batteries can provide thousand s of amps of short-circuit current, you need fuses or circuit b rea kers that can safely withstand the short-circuit current that the batteries can produce. T o select the corr ect fuse type and size: 1. Determine the[...]

  • Pagina 26

    Installation 3–8 975-0128-01-01 Installing the inverter Do not proceed with the installation of your inverter until you have read the section, “Designing Y our Installation” on page 3–1. The more thorough your planning, the better your power needs will be met to achieve maximum performance from yo ur inverter. Safety Instructions Before you[...]

  • Pagina 27

    Installing the inverter 975-0128-01-01 3–9 • DC fuse(s) as calculated in “Calculating Fuse/Circuit Breaker Size” on page 3–7 an d fuse holder(s) • Copper chassis ground cable as calculated in T able 3-2, “Recommended Chassis Ground Cable sizes” on pa ge 3–6 • Battery isolator (if connectin g to a multiple-batter y system) • Ba[...]

  • Pagina 28

    Installation 3–10 975-0128-01-01 Mounting the Inverter Do not mount the inverter under the hood of your veh icle. See “Choosing an Appropriate Locatio n” on page 3–4. T o mount the inverter: 1. Make sure the On/Of f switch is in the Of f position. 2. Select an appropriate mounting loca tion and orientation. The inverter must be oriented in [...]

  • Pagina 29

    Installing the inverter 975-0128-01-01 3–11 A C Connections Y ou can plug your AC loads directly into the receptacles on the inverter front panel. Output power to each receptacle is limited by a circuit breaker to 1500 W atts (15 A). Y ou may also make a permanent AC connection via the AC knockout. This connection must be made in accordance with [...]

  • Pagina 30

    Installation 3–12 975-0128-01-01 Grounding Locations Y ou must connect the chassis groun d terminal to a grou nding point. Follow the installatio n guidelines below . These guidelines assume you a re using the code-compliant D C supply cable and fuse sizes indicate d in this manual. If you are using different sizes, refer to the applicable code f[...]

  • Pagina 31

    Connecting the DC Cables 975-0128-01-01 3–13 Connecting the DC Cables Consult Figure 3-1 , “Configuration for Normal Load s” on page 3–2, or Figure 3-2, “Configuratio n for Heavy Loads” on page 3–2 for additional details that are specific to your installation. T o make the DC connections: 1. Cut the cables to the co rrect length with [...]

  • Pagina 32

    Installation 3–14 975-0128-01-01 4. Install a fuse and disconnec t switch or breaker between th e inverter and the battery . Ensure that the disco nnect switc h or breaker is turned off before installing. They must be installed in the positive side of the DC circuit, as close as possible to the battery . This protects your battery and wiring in c[...]

  • Pagina 33

    Connecting the DC Cables 975-0128-01-01 3–15 6. Connect one connector on the negative cable to the negative terminal on the DC en d. Before pro ceeding, che ck that cab le polarity is correct, and then connect the other end of the cable to the NEGATIVE (–) terminal on the battery . This is the last cable connection you make. If the disconnect s[...]

  • Pagina 34

    3–16 XPower3000.book Page 16 Wednesday, December 10, 2003 6:52 AM[...]

  • Pagina 35

    4–1 4 Oper ation Chapter 4 explains how to ope rate the inverter efficiently and ef fectively . Specifically , this chapter: • Gives procedures for operatin g the inverter from the front panel • Discusses operating limits and inverter loads • Discusses battery charging frequency • Provides information ab out routine maintenance T urning t[...]

  • Pagina 36

    Operation 4–2 975-0128-01-01 T urning the Inverter Off Between Char ges The inverter draws less than 600 mA from the battery with the On/Off switch turned on and no load connected, but left in this state the inverter will eventually discharge the battery . T o prevent unnecessary ba ttery dischar ge, turn the inverter off when you are not using i[...]

  • Pagina 37

    Operating Limits 975-0128-01-01 4–3 Operating Limits P ower Output The XPower Inv erter 3000 Plus can d eliver up to 2500 W continuous and up to 3000 W for five minutes. The wattage rating applies to resistiv e loads such as incandescent lights. Input V oltage The allowable inverter input (battery ) voltage ranges are shown in the following table[...]

  • Pagina 38

    Operation 4–4 975-0128-01-01 Inverter Loads The inverter will operate most AC loads wi thin its power rating of 2500 W . However , some appliance s and equipment may b e difficult to operate, and other appliances may a c tually be damaged if you try to operate them with the inverter. Please read “High Surge Loads” and “T rouble Loads” car[...]

  • Pagina 39

    Routine Maintenance 975-0128-01-01 4–5 Routine Maintenance Minimal maintenance is required to k eep your inverter operating prope rly . Periodically you should: • Clean the exterior of the inverter with a damp cloth to prevent the accumulation of dust and dirt. • Ensure that the DC cables are se cure and fasteners are tight. • Make sure ven[...]

  • Pagina 40

    4–6 XPower3000.book Page 6 Wed nesday, December 10, 2003 6:52 AM[...]

  • Pagina 41

    5–1 5 T r oubleshooting Chapter 5 will help you identify the source of most problems that can occur with the inverter. If you have a problem with the inverter , please review this chapter before contacting place of purchase. If you are unable to solve a proble m and need to contact place of purchase, record the information in the form “Informat[...]

  • Pagina 42

    T roubleshooting 5–2 975-0128-01-01 T r oubleshooting Refer ence W ARNING: Electrical shock and burn hazard Do not disassemble the inverter. It does not contain any user -serviceable parts. Attempting to service the i nve rter yourself could result in an electrical shock or burn. T able 5-1 T roubleshooting Reference # Error/W arn ing Code on Dis[...]

  • Pagina 43

    T roubleshooting Reference 975-0128-01-01 5–3 Consumer Hotline: 1-800-67 0-0707 5 E03 : Flashing Fault LED : Flashin g Alarm: Beeping Inverter is in overload shutdown. Load applied is above the continuou s operation limit. Reduce the load if co ntinuous operation is required . 6 E04 : Flashing Fault LED : Flashin g Alarm: Beeping Inverter is in t[...]

  • Pagina 44

    5–4 XPower3000.book Page 4 Wed nesday, December 10, 2003 6:52 AM[...]

  • Pagina 45

    A–1 A Specifications Appendix A contains electrical perform ance and physical specific ations for the inverter. Electrical P erformance Physical Specifications Specifications are subject to change w ithout notice. Output power at 25ºC (77ºF) ambien t temperature and 12 V dc input: • Maximum continuou s output power • 5 minu te ratin g 2500 [...]

  • Pagina 46

    A–2 XPower3000.book Page 2 Wed nesday, December 10, 2003 6:52 AM[...]

  • Pagina 47

    B–1 B Battery T ypes The information in Appendix B will help you to sel ect, connect, and maintain batteries that are most appropriate for your application. The batteries that you use strongly af fect the performance of the XPower 3000. It is important to co nnect the inverter to the correct size and type of battery . Battery T ypes Automotive St[...]

  • Pagina 48

    Battery T ypes B–2 975-0128-01-01 A battery isolator is a solid-state el ectronic circuit that allows equipment to be operated from an auxiliary battery without danger of di scharging the vehicle’ s starting ba ttery . During vehi cle operation, the ba ttery isolator automatically directs the charge fro m the alternator to the battery requiring[...]

  • Pagina 49

    Estimating Battery Requirements 975-0128-01-01 B–3 This same battery can deliver a higher or lower current for less or more time, limited approximately by the 10 0 Ah figure (for example, 50 A for 2 hours, or 200 A for 1/2 hour), but usual ly the capacity fig ure given is only accurate at the specified rate (20 hours). T o calculate the battery c[...]

  • Pagina 50

    Battery T ypes B–4 975-0128-01-01 Battery Sizing Example This battery sizing example illustrates a typical calculation, assuming an opportunity to char ge the batteries every th ree days. This example illustrates how quickly your battery needs can escalate. T o reduce the required battery size, you can cons erve energy by eliminating or reducing [...]

  • Pagina 51

    Estimating Battery Requirements 975-0128-01-01 B–5 Battery Sizing Worksheet Use the following worksheet to calcul ate your battery needs. T o ens ure suf ficient battery capacity , be gene rous when estima ting the operating time per day for each of the loads you will run. Appliance (A) P ower Consumption (W atts) (B) Operating Time per Day (Hour[...]

  • Pagina 52

    Battery T ypes B–6 975-0128-01-01 Using Multiple Batteries As your power requirements incre ase, you may need to us e more than one battery to obtain suf fic ie nt capacity . Read “T wo Batteries Connected In Parallel” and “T wo Separate Battery Banks” to determine whether two batteries or two battery ban ks are more appro priate for your[...]

  • Pagina 53

    Battery T ips 975-0128-01-01 B–7 Battery Tips Explosive/ Corrosive Gases Lead-acid batteries may emit hydrogen gases, oxygen, and sulfuric ac id fumes when recharging. T o re duce the r isk of explosion: • V ent the battery compartment to prevent the accumulation of gases. • Do not install electronic or electrical equipment in the battery com[...]

  • Pagina 54

    Battery T ypes B–8 975-0128-01-01 Battery Connections Connections to battery posts must be made with permanent connectors that provide a reliable, low-resistance connection. Do not use alligator clips. Clean the connections regularly and preven t corrosion by using a protective spray coating or V a seline. Battery S tate of Char ge Y ou can measu[...]

  • Pagina 55

    C–1 C Alternator s and Char ging Systems A good char ging system is important fo r the health of your batteries. Poor recharging methods can quickly damage batteries. Appendix C prov ides guidelines for rechar ging batteries from an alternator , from AC power , and from alternate ener gy sources. Charging System Requir ements Y our charging syste[...]

  • Pagina 56

    Alternators and Charging Systems C–2 975-0128-01-01 Charging W ith an Engine Alternator Read the following inform ation to determi ne whether your vehicle’ s standard alternator will be adequate by itself, whether you should install an alternator con troller , or whether you need a high-output alternator . Using a Standard V ehicle Alternator A[...]

  • Pagina 57

    Charging F rom A C P ower 975-0128-01-01 C–3 Charging Fr om AC P ower When rechargi ng from AC power , u se a good quality char ger or R V converter that meets the requiremen ts outlined in “Char ging System Requirements” on page C–1. Do not use char gers intended for oc casional recharging of automotive starting batteries. These chargers a[...]

  • Pagina 58

    C–4 XPower3000.book Page 4 Wed nesday, December 10, 2003 6:52 AM[...]

  • Pagina 59

    975-0128-01-01 WA–1 W arranty and Pr oduct Information Wa r r a n t y What does this warranty cover? This Limited W arranty is provided by Xantrex T echnology , Inc. ("Xantrex") and covers defect s in workmanshi p and ma te rials in your XPower Inverter 3000 Plus. This warranty period lasts fo r 12 months fr om the date of purchase at t[...]

  • Pagina 60

    W arranty and Product Information WA–2 975-0128-01-01 What proof of pur chase is requir ed? In any warranty claim, da ted proof of purchase must accompany the product and th e product must not have been disas s embled or modifi ed without prior written authorization by Xantrex. Proof of purchase may be in any one of the following fo rms: • The [...]

  • Pagina 61

    975-0128-01-01 WA–3 Disclaimer Product THIS LIMITED W ARRAN TY IS THE SOLE A ND EXCLUSIVE W ARRANTY PROV IDED BY XANTREX IN CONNECTION WITH Y OUR XANTREX PRODUCT A ND IS, WHERE PERMITT ED BY LA W , IN LIEU OF ALL OTHER W ARRANTIES, CONDIT IONS, GUARANTEES, RE PRESENT A TIONS, OBLIGA TIONS AND LIA BILITIES, EXPRESS OR IMPLIED, ST A T UTOR Y OR OTH[...]

  • Pagina 62

    W arranty and Product Information WA–4 975-0128-01-01 Return Material Authorization P olicy Before returning a product directly to Xantrex you must obtain a Return Material Authorizati on (RMA) number and the correct factory "Shi p T o" address. Products must also be shipped prepaid. Product shipments will be refused and ret urned at yo[...]

  • Pagina 63

    975-0128-01-01 WA–5 Out of W arranty Service If the warranty period for your XPo wer Inverter 3000 Plus has expired , if the unit was damaged by misuse or incorrect installation, if other co nditions of the warrant y have not been met, or if no dated proof of purchase is available, your inverter may be serviced or replaced for a flat fee. T o ret[...]

  • Pagina 64

    W arranty and Product Information WA–6 975-0128-01-01 Information About Y our System As soon as you open your X Power Inverter 3000 Plus package, record the followin g information and be sure to keep y our proof of purch ase. If you need to contact Customer Service, please record the fo llow ing details before calling. This information will help [...]