Go to page of
Similar user manuals
-
Gas Grill
2Wire XTS 3000
6 pages 0.06 mb -
Gas Grill
2Wire 5 TB LTU license J5369AA SNM
13 pages 0.13 mb -
Gas Grill
2Wire 5500
5 pages 0.06 mb -
Gas Grill
2Wire AVX-7300
28 pages 2.72 mb -
Gas Grill
2Wire g700
22 pages 0.31 mb -
Gas Grill
2Wire 10 TB LTU license J5378AA Storage Builder
13 pages 0.13 mb -
Gas Grill
2Wire 1 TB LTU license T2529AA Storage Accountant
13 pages 0.13 mb -
Gas Grill
2Wire 10 TB LTU license for SAM suite J5366AA SAM
13 pages 0.13 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of 2Wire g700, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 2Wire g700 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of 2Wire g700. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of 2Wire g700 should contain:
- informations concerning technical data of 2Wire g700
- name of the manufacturer and a year of construction of the 2Wire g700 item
- rules of operation, control and maintenance of the 2Wire g700 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 2Wire g700 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 2Wire g700, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 2Wire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 2Wire g700.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the 2Wire g700 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 1 IP Enabling Siemens Hicom 300 With Avaya Solutions Running MultiVantage™ Software Configuring a PRI Trunk Connection between an Avaya S8300 Media Server and an Avaya G700 Media Gateway running Avaya [...]
-
Page 2
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 2 1. Introduction: The configuration shown in figure 1 illustrates a PRI Trunk Connection between an Avaya S8300 Media Server and an Avaya G700 Media Gateway (S8300/G700) running Avaya MultiVantage Software placed as an adjunct to a Si[...]
-
Page 3
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 3 2. Equipment and Software Validated: The configuration used to test performance of this solution was established in an Avaya Lab setting within the guidelines and use parameters allowed in the user licenses acquired with the equipmen[...]
-
Page 4
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 4 Software : 1. Recommended Siemens Hicom 300. Release 9006.5 or newer. 2. Firmware for the boards and phones are included in the core software. Hardware: 1. TNBN64P and TNDN64 can be programmed to run PRI and NI2. 2. TMDN TMD24 can on[...]
-
Page 5
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 5 Figure 2a . MM710 DS1 Circuit Pack Administration Figure 2b . MM710 DS1 Circuit Pack Administration[...]
-
Page 6
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 6 Trunk Group: Create a Trunk Group and select “isdn” as the Group Type and a TAC number based on your switches dial-plan. Ensure “PRI/BRI” is the Carrier Medium, this is used for ISDN trunks. Set Dial Access to “Y” and Ser[...]
-
Page 7
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 7 Trunk Group Members: Assign trunk ports to the Trunk Group. Up to 255 ports can be assigned to each ISDN Trunk Group. The Sig Grp prompt will display the signaling group after the Trunk Group is created and assigned to the Signaling [...]
-
Page 8
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 8 Determine If System Has Capacities: <dis-dimen; (Displays System Dimensions) TYPE = cc; DIS-DIMEN:CC; H500: AMO DIMEN STARTED +------------------------------------+------------------------------------+ | NON-CONFIGURABLE PARAMETER[...]
-
Page 9
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 9 Adding a TNDN64 T-1 Board: <add-bcsu BOARD = ? BOARD : SPECIFY BOARD TYPE CHARACTERISTIC : REQUIRED CONDITIONAL POSSIBLE VALUES : STMA STMA SLMN SLMN USED FOR NX64 IPDN IPDN BOARD USED FOR ISDN APPLICATIONS RPER ROLM PERIPHERAL BO[...]
-
Page 10
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 10 ACKTIM = ? ACKTIM : ACKNOWLEDGEMENT TIMER CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 1000-5000 ACKTIM = 1000 DLVTIM = ? DLVTIM : DATA LINK VERIFICATION TIMER CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 5000-60000 DLVTIM = 30000 OCT[...]
-
Page 11
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 11 SET UP - OUT OF SERVICE (NPR) H6 : THE CIRCUIT WAS ADDED TO THE REFERENCE CLOCK TABLE. H19 : WHEN FCTID IS NOT ENTERED, OR FCTID=0 IS ENTERED FOR A TMDN, IT WILL CONFIGURE A TMDN WITH THE DEFAULT FCTID=1. AMO-BCSU -111 BOARD CONFIGU[...]
-
Page 12
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 12 Add Trunk Group Access Codes: <add-tgacc TGRP = 100 SATOPS = ? SATOPS : SATOPS TYPE USAGE FOR THE TRUNK-GROUP CHARACTERISTIC : REQUIRED POSSIBLE VALUES : SAT SAT PROTOCOL VLSAT VLSAT PROTOCOL NONE NON-SATOPS PROTOCOL SATOPS = non[...]
-
Page 13
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 13 CFBLOCK = ? CFBLOCK : CALL FORWARD BLOCKING CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : ENABLED CALL FORWARD BLOCKING ENABLED DISABLED CALL FORWARD BLOCKING DISABLED CFBLOCK = DISABLED ADD-TGACC:100,NONE,C-HAWK,23,BOTH,TERR,,,0,ROUN[...]
-
Page 14
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 14 Display COP (Class of Parameters): <dis-cop; DIS-COP:,,; H500: AMO COP STARTED | | | | | | | | S E A | | | | | | T E S N | | | | | | A S V S P I D |DD| S| | | | D Z L P D D T |TT| U| P | | | I A A S S A N N O |MM| P| D | |COP| A [...]
-
Page 15
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 15 Add COS (Class of Service): <add-cos COPYCOS = NEWCOS = 100 AVCE = ? AVCE : ADD VOICE AUTHORIZATION CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : AGENT ACD AGENT AUTOLOG ACD AUTOLOGON BROADCST SPEAKER CALL DIAL ONE WAY BROADCAST BS[...]
-
Page 16
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 16 MDR MESSAGE/CALL DETAIL RECORDING ORIGONLY ORIGINATE ONLY TERMLPBK DATA REMOTE TERMINAL LOOPBACK URTA UNRESTRICTED TRUNK ACCESS TO AND FROM CO ADTE = AFAX = DVCE = ? DVCE : DELETE VOICE AUTHORIZATION CHARACTERISTIC : OPTIONAL POSSIB[...]
-
Page 17
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 17 Display COS (Class of Service): <dis-cos:all; H500: AMO COS STARTED +------+------------+------------+------------+ | COS | VOICE | DTE | FAX | +------+------------+------------+------------+ | 100 | | | | | | MDR | | | | | TTT |[...]
-
Page 18
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 18 TCCID = ? TCCID : TELEPHONE COMPANY CIRCUIT IDENTIFICATION CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : MAX. OF 30 POSITIONS TCCID = 123456 DEV = ? DEV : DEVICE TYPE (DEVICE HANDLER)/MODULE TYPE CHARACTERISTIC : REQUIRED CONDITIONAL [...]
-
Page 19
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 19 COSNO = 1 DEDSVC = ? DEDSVC : DEDICATED SERVICE FOR PRIB TRUNKS CHARACTERISTIC : OPTIONAL CONDITIONAL POSSIBLE VALUES : NONE NOT A SPECIAL DEVICE TTA TIE TRUNK ACCESS FX FOREIGN EXCHANGE ACCESS SERVICE PRIV PRIVATE NETWORK SERVICE M[...]
-
Page 20
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 20 Modify D-Channel from Default: <cha-tcsu PEN = 1-1-73-24 COTNO = COPNO = DPLN = ITR = TGRP = ACDATA = CCT = DITIDX = TRKID = TCCID = DEV = ? DEV : DEVICE TYPE (DEVICE HANDLER)/MODULE TYPE CHARACTERISTIC : OPTIONAL CONDITIONAL POS[...]
-
Page 21
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 21 D10036 NTI DMS-100(RELEASE BCS-36) D10037 NTI DMS-100(RELEASE BCS-37/LEC-03- FUTURE) D10038 NTI DMS-100(RELEASE BCS-38/LEC-04- FUTURE) D10039 NTI DMS-100(RELEASE BCS-39/LEC-05- FUTURE) EWSD11 SIEMENS EWSD(RELEASE APS-11) EWSD12 SIEM[...]
-
Page 22
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 22 Display Trunk Members: <dis-tscu PEN1 = 1-1-73-24; H500: AMO TCSU STARTED +------------------------------------------------------------------------+ | PEN: 1- 1- 73- 1 INS: Y BOARD: TMDN64P DEV: PRIB TGRP: 100 | +----------------[...]